This document includes instructions for installing
AXIS P8221 Network I/O Audio Module on your network.
Previous experience of networking will be beneficial
when installing the product.
Legal Considerations
Video and audio surveillance can be prohibited by laws
that vary from country to country. Check the laws in
your local region before using this product for
surveillance purposes.
This product includes one (1) AAC decoder license. To
purchase further licenses, contact your reseller.
Electromagnetic Compatibility (EMC)
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there is
no guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to
radio or television reception, which can be determined
by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or
more of the following measures: Re-orient or relocate
the receiving antenna. Increase the separation between
the equipment and receiver. Connect the equipment to
an outlet on a different circuit to the receiver. Consult
your dealer or an experienced radio/TV technician for
help. Shielded (STP) network cables must be used with
this unit to ensure compliance with EMC standards.
USA - This equipment has been tested and found to
comply with the limits for a Class B computing device
pursuant to Subpart B of Part 15 of FCC rules, which are
designed to provide reasonable protection against such
interference when operated in a commercial
environment. Operation of this equipment in a
residential area is likely to cause interference, in which
case the user at his/her own expense will be required to
take whatever measures may be required to correct the
interference.
Canada - This Class B digital apparatus complies with
Canadian ICES-003.
Europe - This digital equipment fulfills the
requirements for radiated emission according to limit B
of EN55022, and the requirements for immunity
according to EN55024 residential and commercial
industry.
Japan - This is a class B product based on the standard
of the Voluntary Control Council for Interference from
Information Technology Equipment (VCCI). If this is used
near a radio or television receiver in a domestic
environment, it may cause radio interference. Install and
use the equipment according to the instruction manual.
Australia - This electronic device meets the
requirements of the Radio communications
(Electromagnetic Compatibility) Standard AS/NZS
CISPR22:2002.
Korea - Class B: As this equipment has obtained EMC
registration for household use, it can be used in any area
including residential areas.
Equipment Modifications
This equipment must be installed and used in strict
accordance with the instructions given in the user
documentation. This equipment contains no
user-serviceable components. Unauthorized equipment
changes or modifications will invalidate all applicable
regulatory certifications and approvals.
Liability
Every care has been taken in the preparation of this
document. Please inform your local Axis office of any
inaccuracies or omissions. Axis Communications AB
cannot be held responsible for any technical or
typographical errors and reserves the right to make
changes to the product and documentation without
prior notice. Axis Communications AB makes no
warranty of any kind with regard to the material
contained within this document, including, but not
limited to, the implied warranties of merchantability
and fitness for a particular purpose. Axis
Communications AB shall not be liable nor responsible
for incidental or consequential damages in connection
with the furnishing, performance or use of this material.
RoHS
This product complies with both the European
RoHS directive, 2002/95/EC, and the Chinese
RoHS regulations, ACPEIP.
WEEE Directive
The European Union has enacted a Directive
2002/96/EC on Waste Electrical and Electronic
Equipment (WEEE Directive). This directive is
applicable in the European Union member
states.
The WEEE marking on this product (see right) or its
documentation indicates that the product must not be
disposed of together with household waste. To prevent
possible harm to human health and/or the environment,
the product must be disposed of in an approved and
environmentally safe recycling process. For further
information on how to dispose of this product correctly,
contact the product supplier, or the local authority
responsible for waste disposal in your area.
Business users should contact the product supplier for
information on how to dispose of this product correctly.
This product should not be mixed with other commercial
waste.
Support
Should you require any technical assistance, please
contact your Axis reseller. If your questions cannot be
answered immediately, your reseller will forward your
queries through the appropriate channels to ensure a
rapid response. If you are connected to the Internet, you
can:
• download user documentation and firmware updates
• find answers to resolved problems in the FAQ database.
Search by product, category, or phrases
• report problems to Axis support by logging in to your
private support area.
AXIS P8221 uses a 3.0V CR2032 Lithium battery, see
91 for more information.
page
AXIS P8221 Installation GuidePage 3
Important!
This product must be used in
compliance with local laws and
regulations.
AXIS P8221
Installation Guide
This installation guide provides instructions for installing an AXIS P8221 Network I/O Audio Module
on your network. For all other aspects of using the product, please see the User’s Manual, available
on the CD included in this package, or from www.axis.com
Installation steps
Follow these steps to install AXIS P8221 on your local network (LAN):
1. Check the package contents against the list below.
2. Hardware overview. See page 4.
3. Install the hardware. See page 5.
4. Assign an IP address. See page 6.
5. Set the password. See page 9.
Package contents
ItemModels/variants/notes
Network I/O Audio Module AXIS P8221
Indoor power supply
LED indicators for
microphone power,
power,
status,
network,
microphone level
Audio 2: terminal connector
Control button
I/O terminal connectors A & B
Power connector
Audio 1: Audio in/out
Mounting hole
Gain control
RS-232/485/422 terminal connector
Mounting hole
Hardware overview
AXIS P8221 Installation GuidePage 5
Install the hardware
IMPORTANT! - The casing of AXIS P8221 is not approved for outdoor use. The device
may only be installed in indoor environments.
!
Mount AXIS P8221
AXIS P8221 is supplied with a mounting kit containing screws and plugs for mounting the device to
a concrete wall:
1. Place AXIS P8221 against the wall and mark the location of the two mounting holes (see
page 4) through which the device will be attached.
2. Remove AXIS P8221 and drill the two mounting holes.
3. Insert the wall plugs into the wall, position AXIS P8221 and attached to the wall using the
screws provided.
The supplied protective pads can be used to avoid scratching the surface on which AXIS P8221 is
placed. Punch out the pads and apply them to the underside of the device.
Connect the cables
Please refer to Unit connectors, on page 13, for wiring information.
1. Optionally connect external input/output devices, e.g. alarm devices.
2. Optionally connect external audio equipment.
3. Optionally connect external equipment to the RS-232/485/422 connector.
4. Connect AXIS P8221 to the network using a shielded network cable.
5. Connect power, using one of the methods listed below:
• PoE (Power over Ethernet). If available, this is automatically detected when the network
cable is connected.
• Connect an external power adapter to the power connector block.
6. Check that the indicator LEDs indicate the correct conditions. See the table on page 17 for
further details.
ENGLISH
Page 6 AXIS P8221 Installation Guide
Assign an IP address
Most networks today have a DHCP server that automatically assigns IP addresses to connected
devices. If your network does not have a DHCP server AXIS P8221 will use 192.168.0.90 as the
default IP address.
AXIS IP Utility and AXIS Camera Management are recommended methods for setting an IP
address in Windows. These free applications are available on the AXIS Network Video Product CD
supplied with this product, or they can be downloaded from www.axis.com/techsup. Depending on
the number of devices you wish to install, use the method that suits you best.
MethodRecommended forOperating system
AXIS IP Utility
See page 7
AXIS Camera Management
See page 8
Notes:
• If assigning the IP address fails, check that there is no firewall blocking the operation.
• For other methods of assigning or discovering the IP address, e.g. in other operating systems, see
page 11.
Single device
Small installations
Multiple devices
Large installations
Installation on a different subnet
Windows
Windows 2000
Windows XP Pro
Windows Server 2003
Windows Vista
AXIS P8221 Installation GuidePage 7
AXIS IP Utility - single device/small installation
AXIS IP Utility automatically discovers and displays Axis devices on your network. The application
can also be used to manually assign a static IP address.
Note that the computer running AXIS IP Utility must be on the same network segment (physical
subnet) as AXIS P8221.
Automatic discovery
1. Check that AXIS P8221 is connected to the network and that power has been applied.
2. Start AXIS IP Utility.
3. When AXIS P8221 appears in the window, double-click to open its home page.
4. See page 9 for instructions on how to assign the password.
ENGLISH
Set the IP address manually (optional)
1. Acquire an unused IP address on the same network segment as your computer.
2. Select AXIS P8221 in the list.
3. Click the button Assign new IP address to selected device and enter the IP address.
4. Click the Assign button and proceed according to instructions.
5. Click the Home Page button to access the device’s web pages.
6. See page 9 for instructions on how to set the password.
Page 8 AXIS P8221 Installation Guide
AXIS Camera Management - multiple devices/large installations
AXIS Camera Management can automatically discover multiple Axis devices, show connection
status, manage firmware upgrades and set IP addresses.
Automatic discovery
1. Check that AXIS P8221 is connected to the network and that power has been applied.
2. Start AXIS Camera Management. When AXIS P8221 appears in the window, right-click the link
and select Live View Home Page.
3. See page 9 for instructions on how to set the password.
Assign an IP address in a single device
1. Select AXIS P8221 in AXIS Camera Management and click the Assign
IP button.
2. Select Assign the following IP address and enter the IP address, the
subnet mask and default router for the device.
3. Click OK.
Assign IP addresses in multiple devices
AXIS Camera Management speeds up the process of
assigning IP addresses to multiple devices, by suggesting
IP addresses from a specified range.
1. Select the devices you wish to configure (different
models can be selected) and click the Assign IP
button.
2. Select Assign the following IP address range and
enter the range of IP addresses, the subnet mask and
default router the devices will use.
3. Click Update. Suggested IP addresses are listed under
New IP Addresses and can be edited by selecting a
device and clicking the Edit button.
4. Click OK.
AXIS P8221 Installation GuidePage 9
To configure the password directly
via an unencrypted connection, enter
the password here.
To create an HTTPS connection, start
by clicking this button.
Set the password
To gain access to the device, the password for the default administrator user root must be set. This
is done in the ‘Configure Root Password’ dialog, which is displayed when AXIS P8221 is accessed
for the first time.
To prevent network eavesdropping when setting the root password, this can be done via an
encrypted HTTPS connection, which requires an HTTPS certificate.
HTTPS (Hypertext Transfer Protocol over SSL) is a protocol used to encrypt the traffic between web
Note:
browsers and servers. The HTTPS certificate controls the encrypted exchange of information.
To set the password via a standard HTTP connection, enter it directly in the first dialog shown
below.
To set the password via an encrypted HTTPS connection, follow these steps:
1. Click the Create self-signed certificate button.
2. Provide the requested information and click OK. The certificate is created and the password can
now be set securely. All traffic to and from the device is encrypted from this point on.
3. Enter a password and then re-enter it to confirm the spelling. Click OK. The password has now
been configured.
ENGLISH
4. To log in, enter the user name “root” in the dialog as requested.
Note:
The default administrator user name root cannot be deleted.
5. Enter the password as set above, and click OK. If the password is lost, the device must be reset
to the factory default settings. See page 18.
Page 10 AXIS P8221 Installation Guide
Setup – Provides all the
tools for configuring the
device to requirements.
Help – Displays online
help on all aspects of
using the device.
6. If required, click Yes to install AXIS Media Control (AMC), which gives access to the audio
stream in Internet Explorer. You will need administrator rights on the computer to do this.
Note:
To install AMC in Windows Vista, you must run Internet Explorer as administrator. Right-click
the Internet Explorer icon and select Run as administrator.
7. If required, click the link to install missing decoders.
8. The Live View page of AXIS P8221 is displayed, with links to the Setup tools, which allow you to
customize the device.
AXIS P8221 Installation GuidePage 11
Other methods of setting the IP address
The table below shows the other methods available for setting or discovering the IP address. All
methods are enabled by default, and all can be disabled.
UPnP™
Bonjour
AXIS Dynamic DNS
Service
ARP/Ping
View DHCP server
admin pages
Use in operating
system
Windows When enabled on your computer, the device is automatically
MAC OSX
(10.4 or later)
AllA free service from Axis that allows you to quickly and simply
AllSee below. The command must be issued within 2 minutes of
AllTo view the admin pages for the network DHCP server, see the
Notes
detected and added to My Network Places/Network.
Applicable to browsers with support for Bonjour. Navigate to the
Bonjour bookmark in your browser (e.g. Safari) and click on the
link to access the product’s web pages.
install your device. Requires an Internet connection with no HTTP
proxy. See www.axiscam.net for more information.
connecting power to the device.
server’s own documentation.
ENGLISH
Page 12 AXIS P8221 Installation Guide
Set the IP address with ARP/Ping
1. Acquire a free static IP address on the same network segment your computer is connected to.
2. Locate the serial number (S/N) on the device’s label.
3. Open a command prompt on your computer and enter the following commands:
4. Check that the network cable is connected and then start/restart AXIS P8221, by disconnecting
and reconnecting power. If PoE is used, start/restart the device by disconnecting and then
reconnecting the network cable.
5. Close the command prompt when you see ‘Reply from 192.168.0.125:...’ or similar.
6. In your browser, type in http://<IP address> in the Location/Address field and press Enter on
your keyboard.
Notes:
• To open a command prompt in Windows: from the Start menu, select Run... and type cmd. Click OK.
• To use the ARP command in Windows Vista, right-click the command prompt icon and select Run as
administrator.
• To use the ARP command on a Mac OS X, use the Terminal utility in Application > Utilities.
AXIS P8221 Installation GuidePage 13
Unit connectors
RS-232/485/422 connector - 5-pin terminal block for the RS-232/485/422 serial interface used
to control auxiliary equipment. The port can be used in the following modes:
• 2TX/2RX RS-232 interface (RD, TD, RTS, CTS)
• Bidirectional RS-485 half-duplex port for data transmission using
two wires, one combined RX/TX pair
• Bidirectional RS-485 full-duplex port for data transmission using
four wires, one RX pair and one TX pair
• Unidirectional RS-422 port for transmitting and receiving data
using two wires, RX- or TX pair
• Bidirectional RS-422 full-duplex port for data transmission
(point-to-point) using four wires, one RX pair and one TX pair
When using a long cable and high communication speeds it is recommended to insert a 120 ohm
Note:
termination resistor between the RS-485 wires at both ends of the cable.
Function Pin Notes
RS-232 TD alt
RS-485/422TX(B)
RS-232 RTS alt
RS-485/422TX(A)
GND3Ground
RS-232 CTS alt
RS-485/422RX(B)
RS-232 RD alt
RS-485/422RX(A)
1RS-232 Driver Output
TX pair for RS-422 and 4-wire RS-485 (combined RX/TX pair
for 2-wire RS-485)
2
4RS-232 Receiver Input
RX pair for all RS-485/422 modes
5
ENGLISH
Audio 1:
Audio in (pink) – 3.5 mm input for a mono microphone, or a line-in mono signal (left channel is
used from a stereo signal).
Audio out (green) – 3.5 mm output for audio (line level) that can be connected to a public address
(PA) system or an active speaker with a built-in amplifier. A pair of headphones can also be
attached. A stereo connector must be used for the audio out.
MIC+1Microphone in
MIC-2
GND3Ground
SPKR+4Speaker out with built-in amplifier
SPKR-5
Gain - Controls the microphone in level (Audio 2). Use a screwdriver (2.5 mm flathead) to adjust
the level.
Network connector - RJ-45 Ethernet connector. Supports Power over Ethernet (PoE class 3). Using
shielded cables is recommended.
Power connector - 3-pin terminal block used for power input.
Provides 48 V DC phantom voltage
1 W RMS at 10% THD, min. 4 ohm
AXIS P8221 Installation GuidePage 15
I/O terminal connectors A and B - Used in applications for e.g. event triggering and alarm
notifications. In addition to an auxiliary power and a GND pin, each I/O terminal connector has 4
pins that can be configured as either input or output. These pins provide the interface to:
• Digital output – For connecting external devices such as
relays and LEDs. Connected devices can be activated by
VAPIX® Application Programming Interface (API), by output
buttons on the Live View page or by an Event Type. The
output will show as active (shown under Ports & Devices > I/O Ports) if the alarm device is activated.
• Digital input – An alarm input for connecting devices that
can toggle between an open and closed circuit, for example: PIRs, door/window contacts,
glass break detectors, etc. When a signal is received the state changes and the input
becomes active (shown under Ports & Devices > I/O Ports, and, if enabled, on the Live View
page).
Function Pin NotesSpecifications
GND1Ground
3.3 V DC
Power
Configurable
(Input or
Output)
2Can be used to power auxiliary equipment.
Note: This pin can only
3-6Digital input – Connect to GND to activate, or
leave floating (unconnected) to deactivate.
Digital output – Uses an open-drain NFET transis-
tor with the source connected to GND. If used with
an external relay, a diode must be connected in
parallel with the load, for protection against voltage transients.
be used as power out.
Max load = 250 mA
Min. input = -40 V DC
Max. input= +40 V DC
Max. load =100 mA
Max. voltage = + 40 V DC
ENGLISH
Page 16 AXIS P8221 Installation Guide
AXIS P8221
E.g. push button
3.3 V
G
S
D
1
2
I/O 4 configured as output
I/O 3 configured as input
3.3 V max 250 mA
Connection diagram
The following connection diagram gives an example of how to connect an auxiliary device to the
I/O terminal connectors.
AXIS P8221 Installation GuidePage 17
LED indicators
LEDColorIndication
Mic level GreenMicrophone level signal between -20 dB and -3 dB
AmberMicrophone level signal between -3 dB and -1 dB
RedMicrophone level signal above -1 dB
NetworkGreenSteady for connection to a 100 Mbit/s network. Flashes for network activity.
AmberSteady for connection to 10 Mbit/s network. Flashes for network activity.
UnlitNo network connection.
StatusGreenSteady green for normal operation.
AmberSteady during startup, during reset to factory default or when restoring settings.
Flashes while waiting to record.
RedFlashes while recording audio clips.
Slow flash for failed upgrade.
PowerGreenNormal operation
AmberFlashes green/amber during firmware upgrade.
Mic
power
Note: The microphone level LED can be enabled and disabled from the Setup > Audio > Audio Settings
Amber48 V DC phantom power on
Unlit48 V DC phantom power off
page.
ENGLISH
Page 18 AXIS P8221 Installation Guide
Tip!
Visit www.axis.com/techsup to check if there is updated firmware available for your AXIS
P8221. To see the currently installed firmware version, see the About web page in the
device’s Setup tools.
Resetting to the factory default settings
This will reset all parameters, including the IP address, to the factory default settings:
1. Disconnect the power from AXIS P8221, or if PoE is used disconnect the network cable.
2. Press and hold the Control button (see page 4) and reconnect power or the network cable if PoE
is used.
3. Keep the Control button pressed until the Status indicator displays amber (this may take up to
15 seconds).
4. Release the Control button. When the Status indicator displays green (which can take up to 1
minute) the process is complete and the device has been reset.
5. Re-assign the IP address, using one of the methods described in this document.
It is also possible to reset parameters to the original factory default settings via the web interface.
For more information, please see the online help or the User’s Manual.
Access from the Internet
Once installed, your AXIS P8221 is accessible on your local network (LAN). To access AXIS P8221
from the Internet, network routers must be configured to allow incoming traffic, which is usually
done on a specific port
• HTTP port (default port 80) for viewing and configuration
• RTSP port (default port 554) for playing audio streams
Please refer to the documentation for your router for further instructions. For more information on
this and other topics, visit Axis Support web at www.axis.com/techsup
Further information
The User’s Manual is available from Axis web site at www.axis.com or from the AXIS Network Video
Product CD supplied with this product.
AXIS P8221 Guide d'installation Page 19
Important !
Ce produit doit être utilisé
conformément aux lois et
dispositions locales en vigueur.
AXIS P8221
Guide d'installation
Ce guide d'installation explique comment installer le Module audio E/S réseau AXIS P8221 sur votre
réseau. Pour toute autre question concernant l’utilisation du produit, reportez-vous au manuel de
l’utilisateur du produit, que vous trouverez sur le CD joint ou sur le site www.axis.com
Procédure d’installation
Procédez comme suit pour installer le AXIS P8221 sur votre réseau local :
1. Vérification du contenu de l’emballage par rapport à la
liste ci-dessous.
2. Vue d’ensemble du matériel. Reportez-vous à la page 20.
3. Installation du matériel. Reportez-vous à la page 21.
4. Attribution d’une adresse IP. Reportez-vous à la page 22.
5. Configuration du mot de passe. Reportez-vous à la page 26.
document)
Document de garantie d’Axis
Étiquette de numéro de série supplémentaire
FRAN
Ç
AIS
Page 20 AXIS P8221 Guide d'installation
Connecteur réseau (PoE)
Témoins DEL
alimentation du microphone,
alimentation,
état,
réseau,
niveau du microphone
Audio 2 : Connecteur pour terminaux
Bouton de commande
Connecteurs pour terminaux d’E/S A & B
Connecteur d’alimentation
Audio 1 : Entrée/sortie audio
Trou de fixation
Commande de gain
Connecteur pour terminaux RS-232/485/422
Trou de fixation
Vue d'ensemble du matériel
AXIS P8221 Guide d'installation Page 21
Installation du matériel
IMPORTANT ! - Le boîtier du AXIS P8221 n'est pas approuvé pour une utilisation en
extérieur. Le périphérique doit être uniquement installé en intérieur.
!
Montage du AXIS P8221
Le AXIS P8221 est fourni avec un kit de montage contenant des vis et des chevilles pour monter le
périphérique sur un mur en béton :
1. Placez le AXIS P8221 contre le mur et marquez l’emplacement des deux trous de fixation (cf.
page 20) qui seront utilisés pour la fixation.
2. Retirez le AXIS P8221 et percez les deux trous de montage.
3. Insérez les chevilles dans le mur, positionnez le AXIS P8221 et fixez-le au mur à l’aide des vis
fournies.
Les patins de protection fournis peuvent être utilisés pour éviter de rayer la surface sur laquelle le
AXIS P8221 est placé. Détachez les patins de leur support et appliquez-les sur le dessous du
périphérique.
Branchement des câbles
Reportez-vous à la Connecteurs de l’appareil, page 30 pour plus d'informations sur le câblage.
1. Si vous le souhaitez, connectez des dispositifs d’entrée/sortie externes, tels que des systèmes
d’alarme.
2. Vous pouvez également connecter des équipements audio externes.
3. Connectez les équipements externes optionnels au connecteur RS-232/485/422.
4. Connectez le AXIS P8221 au réseau à l’aide d’un câble réseau blindé.
5. Branchez l’alimentation selon l’une des méthodes décrites ci-dessous.
• Alimentation par Ethernet (PoE) Si elle est disponible, elle est automatiquement détectée
quand le câble réseau est connecté.
• Connectez un adaptateur d’alimentation externe au bloc de connexion d'alimentation.
6. Vérifiez que les voyants indiquent les conditions correctes. Pour plus d'informations, reportezvous au tableau de la page 34.
FRAN
Ç
AIS
Page 22 AXIS P8221 Guide d'installation
Attribution d'une adresse IP
Aujourd'hui, la plupart des réseaux sont équipés d’un serveur DHCP qui attribue automatiquement
des adresses IP aux périphériques connectés. Si ce n'est pas le cas de votre réseau, le AXIS P8221
utilisera l'adresse IP par défaut 192.168.0.90.
Il est conseillé d'utiliser AXIS IP Utility et AXIS Camera Management pour configurer une adresse
IP sous Windows. Ces deux applications gratuites sont disponibles sur le CD joint à votre produit de
vidéo sur IP AXIS. Vous pouvez également les télécharger à partir du site www.axis.com/techsup.
Choisissez la méthode qui vous convient le mieux, selon le nombre de périphériques à installer.
MéthodeRecommandée pourSystème
d'exploitation
AXIS IP Utility
Reportez-vous à la page 23
AXIS Camera Management
Reportez-vous à la page 24
Remarques :
• En cas d’échec de l’attribution d’adresse IP, vérifiez qu’aucun pare-feu ne bloque l’opération.
• Pour connaître les autres méthodes d’attribution ou de détection de l’adresse IP, par exemple sous
d’autres systèmes d’exploitation, reportez-vous à la page 28.
Périphérique simple
Petites installations
Plusieurs périphériques
Grandes installations
Installation sur un autre sousréseau
Windows
Windows 2000
Windows XP Pro
Windows Server 2003
Windows Vista
AXIS P8221 Guide d'installation Page 23
AXIS IP Utility - un seul périphérique/petite installation
AXIS IP Utility détecte automatiquement les périphériques Axis de votre réseau et les affiche. Cette
application sert également à attribuer manuellement une adresse IP statique.
Notez que l'ordinateur exécutant l'application AXIS IP Utility doit se trouver sur le même segment
de réseau (sous-réseau physique) que le AXIS P8221.
Recherche automatique
1. Vérifiez que le AXIS P8221 est connecté au réseau et que le périphérique est sous tension.
2. Lancez AXIS IP Utility.
3. Lorsque l'icône du AXIS P8221 apparaît dans la fenêtre, double-cliquez dessus pour ouvrir la
page d'accueil correspondante.
4. Reportez-vous à la page 26 pour savoir comment assigner le mot de passe.
Configuration manuelle de l’adresse IP (facultatif)
1. Trouvez une adresse IP inutilisée sur le même segment de réseau que celui de votre ordinateur.
2. Sélectionnez AXIS P8221 dans la liste.
3. Cliquez sur le bouton Assign new IP address to selected device (Attribuer une nouvelle
adresse IP au périphérique sélectionné) et saisissez l’adresse IP.
4. Cliquez sur le bouton Assign (Attribuer) et suivez les instructions.
5. Cliquez sur le bouton Home Page (Page d'accueil) pour accéder aux pages Web du périphérique.
6. Reportez-vous à la page 26 pour savoir comment configurer le mot de passe.
FRAN
Ç
AIS
Page 24 AXIS P8221 Guide d'installation
AXIS Camera Management - plusieurs périphériques/grandes
installations
AXIS Camera Management peut détecter automatiquement plusieurs périphériques Axis, afficher
l’état de connexion, gérer les mises à niveau du micrologiciel et configurer les adresses IP.
Recherche automatique
1. Vérifiez que le AXIS P8221 est connecté au réseau et que le périphérique est sous tension.
2. Lancez AXIS Camera Management. Lorsque le AXIS P8221 apparaît dans la fenêtre, cliquez sur
le lien avec le bouton droit de la souris et sélectionnez Live View Home Page (Page d’accueil –
Vidéo en direct).
3. Reportez-vous à la page 26 pour savoir comment configurer le mot de passe.
Attribution d'une adresse IP à un seul périphérique
1. Sélectionnez AXIS P8221 dans l’application AXIS Camera
Management, puis cliquez sur le bouton Assign IP(Attribuer une
adresse IP).
2. Sélectionnez Assign the following IP address (Attribuer l’adresse IP
suivante) et saisissez l’adresse IP, le masque de sous-réseau et le
routeur par défaut que le périphérique utilisera.
3. Cliquez sur OK.
AXIS P8221 Guide d'installation Page 25
Attribution d'adresses IP à plusieurs périphériques
AXIS Camera Management accélère le processus
d’attribution d’adresses IP à plusieurs périphériques en
suggérant des adresses IP parmi une plage spécifiée.
1. Sélectionnez les périphériques à configurer (il peut
s’agir de plusieurs modèles), puis cliquez sur le
bouton Assign IP (Attribuer une adresse IP) .
2. Sélectionnez Assign the following IP address range
(Attribuer la plage d'adresses IP suivante) et saisissez
la plage d'adresses IP, le masque de sous-réseau et le
routeur par défaut que les périphériques utiliseront.
3. Cliquez sur Update (Mettre à jour). Les adresses IP
suggérées sont énumérées sous le champ New IP Addresses (Nouvelles adresses IP) et peuvent être
modifiées en sélectionnant un périphérique et en cliquant sur le bouton Edit (Modifier).
4. Cliquez sur OK.
FRAN
Ç
AIS
Page 26 AXIS P8221 Guide d'installation
Pour configurer directement le mot
de passe via une connexion cryptée,
saisissez le mot de passe à cet
endroit.
Pour créer une connexion HTTPS,
cliquez sur ce bouton.
Configuration du mot de passe
Pour accéder au périphérique, le mot de passe par défaut de l’administrateur, root, doit être
configuré. Pour ce faire, utilisez la boîte de dialogue Configure Root Password (Configurer le mot
de passe root) qui s'affiche lors du premier accès au AXIS P8221.
Pour éviter les écoutes électroniques lors de la configuration du mot de passe root, utilisez une
connexion HTTPS cryptée nécessitant un certificat HTTPS.
Remarque:
Pour configurer le mot passe avec une connexion HTTP standard, saisissez directement le mot de
passe dans la première boîte de dialogue représentée ci-dessous.
Pour configurer le mot passe avec une connexion HTTPS cryptée, procédez comme suit :
1. Cliquez sur le bouton Create self-signed certificate (Créer un certificat autosigné).
2. Saisissez les informations demandées, puis cliquez sur OK. Le certificat est créé et le mot de
passe peut maintenant être configuré en toute sécurité. Tout le trafic vers et depuis le est
désormais crypté.
3. Saisissez un mot de passe, puis saisissez-le de nouveau pour confirmation. Cliquez sur OK. Le
mot de passe est maintenant configuré.
Le protocole HTTPS (Hypertext Transfer Protocol over Secure Socket Layer) est utilisé pour
crypter le trafic entre les navigateurs web et les serveurs. Le certificat HTTPS contrôle
l’échange crypté d’informations.
4. Pour vous connecter, saisissez le nom d’utilisateur « root » dans la boîte de dialogue à l’invite.
Remarque:
Le nom d’utilisateur par défaut de l’administrateur est root et il ne peut pas être
supprimé.
AXIS P8221 Guide d'installation Page 27
Setup (Configuration) :
contient tous les outils
nécessaires pour configurer
le périphérique en fonction
de vos besoins.
Help (Aide) : affiche
une aide en ligne sur
l’utilisation du
périphérique.
5. Saisissez le mot de passe de la manière indiquée ci-dessus et cliquez sur OK. Si vous avez oublié
votre mot de passe, vous devrez rétablir les paramètres d’usine par défaut de votre périphérique.
Reportez-vous à la page 35.
6. Si nécessaire, cliquez sur Yes (Oui) pour installer AXIS Media Control (AMC) afin de pouvoir
visualiser le flux audio dans Internet Explorer. Vous devez pour cela avoir des droits
d'administrateur sur cet ordinateur.
Remarque: Pour installer AMC sous Windows Vista, vous devez exécuter Internet Explorer en tant
qu’administrateur. Cliquez avec le bouton droit de la souris sur l’icône Internet Explorer
et sélectionnez Run as administrator (Exécuter en tant qu’administrateur).
7. Si nécessaire, cliquez sur le lien pour installer les décodeurs manquants.
8. La page Live View (Vidéo en direct) d’AXIS P8221 s’affiche, avec des liens vers les outils de
configuration, lesquels vous permettent d’adapter le périphérique à vos besoins.
FRAN
Ç
AIS
Page 28 AXIS P8221 Guide d'installation
Autres méthodes de configuration de l’adresse IP
Le tableau ci-dessous indique les autres méthodes permettant de configurer ou de déterminer
l’adresse IP. Toutes les méthodes sont activées par défaut et peuvent être désactivées.
UPnP™
Bonjour
AXIS Dynamic DNS
Service
ARP/Ping
Affichage des pages
administratives du
serveur DHCP
Utilisation sous le
système
d’exploitation
Windows Lorsque le périphérique est activé sur votre ordinateur, il est
MAC OS X
(10.4 ou version
ultérieure)
TousService Axis gratuit vous permettant d’installer rapidement et
TousReportez-vous aux instructions ci-dessous. La commande doit
TousPour consulter les pages administratives du serveur DHCP réseau,
Remarques
détecté automatiquement et vient s’ajouter au dossier Favoris
réseau/Réseau.
Pour les navigateurs compatibles avec Bonjour : accédez au
signet de Bonjour dans votre navigateur (par exemple, Safari),
puis cliquez sur le lien pour accéder aux pages Web du
périphérique.
facilement votre périphérique. Nécessite une connexion Internet
sans proxy HTTP. Pour plus d’informations, consultez le site
www.axiscam.net.
être saisie dans les 2 minutes suivant la mise sous tension du
périphérique.
reportez-vous à la documentation du serveur.
Loading...
+ 64 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.