AXIOMTEK ICS-480V User Manual

i
ICS-480V
4U Industrial Workstation with 8.4” LCD
and 14 slots backplane
User’s Manual
ii
The information in this manual has been carefully checked and is believed to be accurate. AXIOMTEK Co., Ltd. assumes no responsibility for any infringements of patents or other rights of third parties which may result from its use.
AXIOMTEK assumes no responsibility for any inaccuracies that may be contained in this document. AXIOMTEK makes no commitment to update or to keep current the information contained in this manual.
AXIOMTEK reserves the right to make improvements to this document and/ or product at any time and without notice.
No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopy­ing, recording, or otherwise, without the prior written permission of AXIOMTEK Co., Ltd.
Copyright 2004 by AXIOMTEK Co., Ltd.
All rights reserved.
July 2004, Version V1.0
Printed in Taiwan
iii
Trademarks Acknowledgments
AXIOMTEK is a trademark of AXIOMTEK Co., Ltd. IBM is a registered trademark of International Business Machines
Corporation. MS-DOS, Microsoft C and QuickBasic are trademarks of Microsoft
Corporation. TURBO C is a trademark of Borland Inc. BASIC is a trademark of Dartmouth College. Intel is a trademark of Intel Corporation. Other brand names and trademarks are the properties and registered
brands of their respective owners.
iv
ESD Precautions
Integrated circuits on computer boards are sensitive to static electricity. To avoid damaging chips from electrostatic discharge, observe the following precautions:
Do not remove boards or integrated circuits from their anti-static packaging
until you are ready to install them.
Before handling a board or integrated circuit, touch an unpainted portion of
the system unit chassis for a few seconds. This helps to discharge any static electricity on your body.
Wear a wrist-grounding strap, available from most electronic component
stores, when handling boards and components.
What To Do If There Is A Problem
If there are damaged or missing parts, contact your supplier and/or dealer immediately. Do not attempt to apply power to the board if there is damage to any of its components.
v
Table of Contents
Chapter 1 Introduction............................................1
1.1 Introduction..................................................................... 1
1.2 General Specification ..................................................... 2
1.3 Passive Backplane Options........................................... 3
1.4 Power Supply Options ................................................... 3
1.5 Dimensions ..................................................................... 4
Chapter 2 System Setup .........................................5
2.1 System Installation ......................................................... 5
2.1.1 Removing the top cover .................................................... 5
2.1.2 Chassis Front and Rear Sections .................................... 6
2.1.3 Front Control ........................................................................
2.1.4 Drive Bay Installation .........................................................8
2.1.5 CPU card Installation.......................................................... 9
2.1.6 Cable connection for CPU card ...................................... 10
2.2 Cable Connection for A/D Board & Fan Power, Power
Switch, and Keyboard Control .................................... 10
2.3 Power Supply ................................................................. 12
2.4 Air Filter Replacement ................................................... 13
2.5 VGA Cable Installation................................................... 14
Appendix A Safety Instructions............................. 17
B.1 Safety Instructions ....................................................... 17
vi
Introduction 1
ICS-480V 4U Industrial W orkstation with 8.4” LCD and 14 slots
backplane User’ s Manual
Chapter 1
Introduction
1.1 Introduction
4U Industrial workstation with 8.4" LCD & 14 slots backplane. The ICS-480V is a 4U 14-slots Rackmount Workstation with 8.4" LCD display and Front panel function & data-entry keypad. This workstation is a full-function and cost-effective designed Industrial Automation Controller. The ICS-480V is available with several combinations of the backplane and power supply, which can apply to versatile applications.
The build-in VGA A/D board ensures the system compatible with variety of Single Board Computers from most of vendors. The front panel OSD controller allows user to tune the LCD into the best position for any environment. To enhance the system for easy maintenance and upgrade, the two front USB ports, 12 function keypad & 65 data-entry keypad have been build-in to the front panel. The air filter is located on the external top-cover which minimizes the system down time for air filter replacement. This ideal industrial-grade workstation can be applied to the various of industrial projects, such as transportation, factory automation, environmental surveillance, and more.
2 Introduction
ICS-480V 4U Industrial Workstation with 8.4” LCD and 14 slots backplane User’ s Manual
1.2 General Specification
Construction: Heavy duty steel chassis
Drive bay: Shock-proof and front accessible 5.25" by three drive bays.
Cooling system: Single 86 CFM cooling fan with top-accessible air filters
Controls: Power switch (on-off or momentary), reset switch, and keyboard lock behind lockable door
LED Indicator: Power and HDD LED for system Power and Hard disk status LED for system power status
Connectors: Front accessible USB and PS/2 key­board, rear panel 9-pin connector (9-pin connec­tor are not include in the M/B version)
Paint Color: Black
Operating Temperature: 0° ~ +50°C (32°F ~ 122°F)
Storage Temperature: -50° ~ +60°C (-40°F ~ 140°F)
Relative Humidity: 10~95%@40°C, non-condens­ing
Vibration: 2G (Non-operation)/ 1G (Operation)
Slide rails: General Device C-300 series supports
Dimensions: 482.6(W) x 452(D) x 177(H)mm (19"x17.8"x7")
Weight: 17-21kg
Safety: CE compliant for integrated system