I. Overview
The CAN (Controller Area Network) is a serial bus system and is usually used in structuring intelligent industrial device networks and building smart automatic control systems. The iCON-101CU is a cost-efficient industrial converter for p airs to PC using the standard USB interface. It supports CAN monitor tool that displays the CAN received message in decimal or hexadecimal mode. This converter shows the time stamp of each received message. The GUI management program and programming guide both are ready for use. The CAN host, monitor or HMI can access and control CAN device through iCON-101CU.
There is a User’s Manual CD-ROM for the iCON-101CU
you have any difficulties in installing.
system. Please consult your local vendor for assistance if
©Copyright 2011 AXIOMTEK Co., Ltd.
Version A1 Oct 2011 Printed in Taiwan 9413C101000E
1
Page 2
iCON-101CU Quick Installation Guide
All Components are fragile and sensitive. If you need to replace or return any components for repair, you must
II. Features
Full compliance with USB 1.1/2.0 (fully speed) Full compliance with CAN 2.0A and CAN 2.0B D-sub DB9 CAN port support 3KV isolation Easily setup to CAN terminator by software configuring CAN transmission speed up to 1Mbps Powered by the USB bus USB type B connector Complies with Class 1, DIV II minimum
contact authorized technicians for a professional handling.
withdrawal requirement of 15N
Provides DIN-Rail mounting, Status LED indicators Driver supports Windows® Server 2008; 2003/Vista/2000/XP/7
and Linux OS
-40~70 wide temperature operating Suitable for industrial
automation and power automation field applications
III. USB connector
Pin Signal Pin Signal
1 5V 2 D­3 D+ 4 GND
IV. CAN interface connector
Pin Signal Function
1 NC No connect 2 CAN_L CAN data line (Low) 3 ISOGND Ground 4 NC No connect 5 NC No connect 6 ISOGND Ground 7 CAN_H CAN data line (High) 8 NC No connect 9 5V (option) 5V (Option)
©Copyright 2011 AXIOMTEK Co., Ltd.
2
Version A1 Oct 2011
Printed in Taiwan
9413C101000E
Page 3
iCON-101CU Quick Installation Guide
There is a User’s Manual CD-ROM for the iCON-101CU
V. LED indicator
LED Color Function
D1
D2
D3
D4
D5
Green (POWER)
Green (CAN Act.)
Orange (CAN Error)
Green (USB Act.)
Orange (CAN Termination)
Light on
Light on
Flashing Light off CAN transmission is idle. Light on
Light off
Flashing
Light on
Light off
Power status indicator. The LED light is on when iCON-101CU is powered on.
PC is sending data to CAN network.
PC is reading data from CAN network.
CAN transmission error occurred.
CAN transmission is working properly.
The LED light flashes during USB data transmission.
CAN termination resistor is enabled.
CAN termination resistor is disabled.
VI. Driver
It is necessary to install driver so the iCON-101CU can work properly under operating system. About how to install the device driver under Windows XP. You can follow the user manual instructions to install the driver.
VII. Commands
you have any difficulties in installing. the system.
system. Please consult your local vendor for assistance if
To meet user’s application purpose, commands are provided for CAN module management, transmitting and receiving messages through iCON-101CU. Each command consists of 3 parts: StartByte, ContentOfCommand and StopByte.
StartByte ContentofCommand StopByte
@ CMD 0x0d (carriage return)
©Copyright 2011 AXIOMTEK Co., Ltd.
Version A1 Oct 2011 Printed in Taiwan 9413C101000E
3
Page 4
contact authorized technicians for a professional handling.
iCON-101CU Quick Installation Guide
All Components are fragile and sensitive. If you need to replace or return any components for repair, you must
Operation can be set to command and data mode. In command mode, CAN module accepts commands and this is the default mode. Data mode is the mode that only and automatically report CAN messages to UART port or USB port based on settings until user inputs command string ‘+++’.
VIII. Utility
You can use hyperterminal program to send and retrieve command messages from iCON-101CU. Or Use AXCAN utility to configure CAN communication parameters. It is also used to transmit or receive CAN messages for simple function testing. About how to install AXCAN software utility please follow the user manual instructions.
4
Version A1 Oct 2011
Printed in Taiwan
9413C101000E
©Copyright 2011 AXIOMTEK Co., Ltd.
Loading...