Axiom Luna SD9, Luna SD9-01, Luna SD9-02, Luna SD9-03 Installation Manual

Page 1
Page 2
Luna Installation Manual
Page 3
(a) Except as provided in the Terms, all express and implied warranties, guarantees and conditions under statute or general law as to:
(i) merchantability, description, quality, suitability or fitness of the Goods or Services for any purpose; or
(ii) design, assembly, installation, materials, workmanship or otherwise,
are expressly excluded.
(b) Axiom is not liable for physical or financial injury, loss or damage or consequential loss or damage of any kind arising out of:
(i) the supply, layout, assembly, installation or operation of the Goods or Services; or
(ii) Axiom’s negligence or other act or omission.
(i) it is the Customer’s responsibility to comply with all Australian laws, all Standards (including but not limited to AS1288 and AS1170.1), the Building Code and the requirements of all relevant authorities;
(ii) the Customer must ensure that any existing structures or substrates to which the Goods are being affixed to are verified by a project engineer as structurally suitable to safely support the Goods or any other items being affixed to the structures or substrates; and
(iii) the Customer must fully insert and tighten all fasteners (including but not limited to baseplate screws) before installation of the Goods.
Luna Installation Manual
Page 4
Axiom BRSCS SCREWS. install 4 sc rews into the top of each post to secure the DRH under cap in position
AFGHR handrail to be snap fitted over Innerrail
AFGIR Innerrail
RETAINED GASKET to the outer face of glass, either SRB for 6mm and 8mm glass, or SRE for 10mm and 12mm glass. Must be slid into post prior to assembly.
TOUGHENED GLASS, of appropriate thickness, depending on the post spacing. Refer to engineering documents for all sizing and applications. Exposed horizontal edges to be flat polished
WEDGE GASKET to the inner face of glass, either SWE70 for 6mm glass, SWE50 for 8mm glass, SWE55 for 10mm glass, or SWE35 for 12mm
glass.
AFG POST. On 90° co rners use AFGEC & AFGIC
ABBAFG SETTING BLOCKS to back of glazing cavity.
AKS GLASS SEAT, to support glass. Attach to AIA insert (press fit)
Luna Installation Manual
AIA INSERT into screw flutes on posts so it sits on top of baseplate. AIA for supporting glass.
CHEMSET Fixings - refer to engineering documents for all sizing and applications
BPFG Baseplate (12mm Thick)
Page 5
AFG post
BPFG Baseplate (12mm Thick)
FV10-45 FASTENERS Self tapping stainless steel countersunk screws supplied by AXIOM GROUP. Use of other screws is strictly not permitted and invalidates all Producer Statements and Warranty. Insert screws until they are fully inserted. All screws must be fully inserted/tightened
FV10-19 FASTENERS Self tapping stainless steel countersunk screws supplied by AXIOM GROUP. Use of other screws is strictly not permitted and invalidates all Producer Statements and Warranty. Insert screws until they are fully inserted. All screws must be fully inserted/tightened
Luna Installation Manual
Page 6
Refer elsewhere for corners, slopes and other situations not illustrated here.
BRSCS SCREWS. install 4 screws into t he top of each post to secure the DRH under cap in position
AFGHR handrail to be snap fitted over Innerrail
AFGIR Innerrail
RETAINED GASKET to the outer face of glass, either SRB for 6mm and 8mm glass, or SRE for 10mm and 12mm glass. Must be slid into post prior to assembly.
TOUGHENED GLASS, of appropriate thickness, depending on the post spacing. Refer to engineering documents for all sizing and applications. Exposed horizontal edges to be flat polished
WEDGE GASKET to the inner face of glass, either SWE70 for 6mm glass, SWE50 for 8mm glass, SWE55 for 10mm glass, or SWE35 for 12mm
glass.
AFG POST with notch out the bottom On 90° co rners use AFGEC & AFGIC
Luna Installation Manual
ABBAFG SETTING BLOCKS to back of glazing cavity.
CHEMSET Fixings - refer to engineering documents for all sizing and applications
FGC Bottom cap Screw fixed to the bottom of the post.
BRSCS SCREWS. 4 fixings into FGC cap
BPFGOH Baseplate (16mm Thick)
Page 7
AFG post with overhang cutout
FGC-35 Bottom cap
BRSCS Screws supplied by AXIOM GROUP. Use of other screws is strictly not permitted and invalidates all Producer Statements and Warranty. Insert screws until they are fully inserted. All screws must be fully inserted/tightened
BPFGOH Baseplate (16mm Thick) Post to be welded to baseplate. Refer to engineering detials for all welding notes.
FV10-45 FASTENERS Self tapping stainless steel countersunk screws supplied by AXIOM GROUP. Use of other screws is strictly not permitted and invalidates all Producer Statements and Warranty. Insert screws until they are fully inserted. All screws must be fully inserted/tightened
Luna Installation Manual
Page 8
Refer elsewhere for corners, slopes and other situations not illustrated here.
BRSCS SCREWS. install 4 screws into t he top of each post to secure the DRH under cap in position
AFGHR handrail to be snap fitted over Innerrail
AFGIR Innerrail
RETAINED GASKET to the outer face of glass, either SRB for 6mm and 8mm glass, or SRE for 10mm and 12mm glass. Must be slid into post prior to assembly.
TOUGHENED GLASS, of appropriate thickness, depending on the post spacing. Refer to engineering documents for all sizing and applications. Exposed horizontal edges to be flat polished
WEDGE GASKET to the inner face of glass, either SWE70 for 6mm glass, SWE50 for 8mm glass, SWE55 for 10mm glass, or SWE35 for 12mm
glass.
AFG RECESSED POST. On 90° co rners use AFGEC & AFGIC
Luna Installation Manual
AFGI I NF I L L. To snap into rear of post
ABBAFG SETTING BLOCKS to back of glazing cavity.
AKS GLASS SEAT, to support glass. Attach to AIA insert (press fit)
AIA INSERT for supporting glass by transferring weight down to base plate or substrate.
CHEMSET Fixing - refer to engineering documents for all sizing and applications
BPFGCF Baseplate (12mm Thick)
Page 9
AFG2 post
AFGI INFILL
BPFGC Baseplate (12mm Thick)
FV10-45 FASTENERS Self tapping stainless steel countersunk screws supplied by AXIOM GROUP. Use of other screws is strictly not permitted and invalidates all Producer Statements and Warranty. Insert screws until they are fully inserted. All screws must be fully inserted/tightened
Luna Installation Manual
FV10-19 FASTENERS Self tapping stainless steel countersunk screws supplied by AXIOM GROUP. Use of other screws is strictly not permitted and invalidates all Producer Statements and Warranty. Insert screws until they are fully inserted. All screws must be fully inserted/tightened
Page 10
Axiom BRSCS screws
AFGIR Innerrail
AFG post
Axiom BRSCS screws
AFGIR Innerrail
AFG post
FIG 1. CONNECTION TO IN-LINE POSTS
BRSCS screws required, 4 per post. 5.5mm Ø fixing holes to be drilled on the outer groove lines of the Inner Rail. See Fig 1 which illustrates use with both continuous and non continuous Inner Rails.
FIG 2. CONNECTION CORNER POSTS
The Inner Rail is mitred over the post, to the desired angle. BRSCS screws required, 2 per rail end.
5.5mm Ø fixing holes to be drilled on the Inner Rail centreline. Fig 2 shows a typical arrangement.
FIG. 1
FIG. 3
Axiom BRSCS screws
AFGIR Innerrail
AFG post
FIG. 1
FIG. 2(A)
Axiom BRSCS screws
AFGIR Innerrail
AFGEC post
FIG 3. CONNECTION OF SLOPING RAILS TO POST
BRSCS screws required, 4 per posts on the outer groove lines of the Inner Rail. Drill 5.5mm Ø fixing holes at the correct angle to the rail. Fig 3 shows a typical arrangement.
Insert screws until they are fully inserted. All screws must be fully inserted/tightened
Luna Installation Manual
Page 11
GLAZING
This section covers the measuring and Installation of the glass panes. Ensure the correct thickness of toughened glass is used.
INSTALL GLASS Glass is to be installed by shuffle glazing. Fit Setting block within the post to ensure glass is blocked in accordance with AS1288 and can not dislodge
RETAINED GLAZING GASKET Install the correct retained glazing gasket. Refer table below.
Glazing Gasket Guide
Glass Thickness External Rubber Internal Rubber
AKS
Bracket
Baseplate
TYPICAL ELEVATION
Opening Width
Glass Width
Lower Edge o f
Glass
Setting Blocks
Refer below to select correct
block for the post
10mm10mm
AKS
Bracket
Baseplate
TYPICAL ELEVATION
6mm
10mm
12mm
ABB20
(Glazing block orientation 2)
AFGEC
SRB
SRE
SRE
SWE70
SWE55
SWE35
ABB20
(Glazing block orientation 2)
AFGEC
Luna Installation Manual
ABB6
ABB6
AFGEC
ABBAFG
AFG
ABB6
AFG35
Loading...