Axiom EP350 v3 Owner's Manual

Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including ampliers) that
produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. e wide blade or the third prong are provided for your safety. If the provided plug does not t into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specied by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specied by the manufacturer, or sold with the apparatus. When a cart
is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualied service personnel. Servicing is required when the apparatus has been damaged in any way,
such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
15. Do not expose this apparatus to dripping or splashing and ensure that no objects lled with liquids, such as vases, are placed on the apparatus.
16. To completely disconnect this apparatus from the AC Mains, disconnect the power supply cord plug from the AC receptacle.
17. e main plug of the power supply cord shall remain readily operable.
18. Do not expose batteries to excessive heat such as sunshine, re or the like.
Step-by-step instructions on conguring your subwoofer.
EP350 v3 Subwoofer
Owners Manual
SAFETY PROCEDURES
• Ensure that you connect your Subwoofer only to the type of power supply indicated on the amplier faceplate, and ensure that the power cord cannot be walked on or otherwise damaged.
• To prevent electric shock, match wide blade of plug to wide slot, fully insert.
• Ensure that objects or liquids are not allowed to penetrate the enclosure.
• Your AXIOM Subwoofers are nished in a durable vinyl and from time to time should be wiped clean gently with a slightly damp cloth to remove any dust or stains.
For any additional information or service, contact:
AXIOM, 2885 HWY 60 Phone: 1-866-244-8796
DWIGHT ON CANADA P01 1H0
e lightning ash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage“ within the product’s enclosure that may be of sucient magnitude to constitute a risk of electric shock to persons.
e exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
WARNING : To reduce the risk of re or electric shock , do not expose this apparatus to rain or moisture.
e Axiom Warranty
All our speaker models; towers, bookshelves, surrounds, centers, subwoofers and
all our ampliers; subwoofer and multichannel ampliers are warrantied against
manufacturer’s defects for 5 years.
AXIOM CANADA INC. warrants this audio loudspeaker system (the “Product”)
to be free from original manufacturing defects in materials and workmanship for ve years from date of purchase from an authorized Axiom dealer. This warranty extends only to the original consumer purchaser. AXIOM CANADA INC. does not warrant goods used in commercial or industrial applications. This warranty does not cover any expenses incurred in any removal or re-installation of the
product.
If the product should prove so defective within the warranty period, return the
product by prepaid delivery to AXIOM CANADA INC., along with the original sales invoice or other proof of purchase, which establishes eligibility for warranty
service. AXIOM CANADA INC. will, at its option, replace or repair the product
free of charge and return the product by prepaid delivery. This warranty does not apply to any product, which has been damaged, misused, altered or repaired by anyone other than an AXIOM CANADA INC. authorized service facility.
Any implied warranties including tness for use and merchantability are limited in duration to the period of the express warranties set forth above, and no person is authorized to assume for Axiom Canada Inc. any other liability in connection with the sale of the product. Axiom Canada Inc. expressly disclaims liability for any incidental and consequential damages caused by the product. The remedies provided under this warranty are exclusive and in lieu of all others.
This warranty gives specic legal rights. In addition, there may be other legal rights arising from the sale of the product, which vary from province to province or state to state. Some provinces / states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may
not apply in some areas.
EP350 v3 Amplier
Step 6:
ACTIVE / DEACTIVE SWITCH: is switch at the top of the
Amplier panel controls the operation of the AUTO ON/OFF circuit that puts the subwoofer into the Standby mode when no signals are detected from your AV receiver or DVD player.
Leave the switch in the ACTIVE position if the AUTO ON/OFF functions normally and turns the subwoofer on (Green LED) when you are using your system and puts it in the Standby mode (Red LED) when you turn o your home theater system. If your subwoofer seems reluctant to turn on even aer you increase the subwoofer signal level in your AV receiver, or you nd the subwoofer turning o during very quiet music or low-volume playback, move the switch to the DEACTIVE position. is will bypass the Auto On/O circuit so that your subwoofer will remain active even during quiet or low volume playback.
Step 7:
0 & 180 PHASE: is synchronizes the in/out movement of the
subwoofer cone driver with the other speakers in your system. Once you have chosen the best location for your subwoofer, try ipping the phase switch between 0 and 180 to see if one or the other setting produces deeper and smoother bass output in your room. Leave the switch at the setting that results in the smoothest and deepest bass at several listening locations in the room. If you hear no dierence, leave the switch at the 0 position. Quite oen the phase switch makes no dierence, but it’s dependent on your room and subwoofer location.
Step 8:
ON/OFF AC POWER/VOLTAGE SETTING: Your subwoofer
is supplied with a “Voltage Selector” set for use with 115 volts from the A/C line. e Voltage Selector can be easily switched over to set your EP350 v3 to 230 volts from the “Voltage Selector”.
Once you have made appropriate connections from the A/V receiver or preamp/processor to the EP350 v3 and set the voltage switch to the proper voltage, nd a nearby AC wall outlet and connect the main power cord to the three-wire socket at the bottom of the control panel. Move the power switch to the ON setting and the LED POWER indicator should glow Green. Leave the switch at the ON setting unless you go away for an extended period. Moving it to OFF will shut down all power to the subwoofer.
Step 9:
TRIGGER IN (3.5mm MINI-Jack): is is for any 8-Volt
to 18-Volt power-on trigger. It is also intended for trigger­controlled operation with future Axiom products.
NOTE: THE POWER SWITCH MUST BE OFF FOR THE TRIGGER TO OPERATE.
Step 1:
LINE IN: e RCA line-level female input, second row, accepts
a standard RCA male plug. Connect a shielded coaxial cable, with male RCA plugs on each end, from the A/V receiver or A/ V preamp processor’s Subwoofer Output jack to the RCA LINE IN female jack on the EP350 v3.
HIGH LEVEL INPUT: Use these “speaker-level” or high-level 5-way binding post connectors only if your receiver or preamp lacks a dedicated line-level subwoofer output jack. C onnect speaker cables from your amplier’s le-channel and right­channel speaker output binding posts to the high-level inputs using banana plugs (single or dual), spade connectors, pins, or bare cable if you wish (unscrew the top of each binding post and insert the cable into the hole in the post; tighten the knurled knob against the cable). Run a second pair of speaker cables from these jacks to your main le and right front speakers. Do not use these connectors if you are already using an RCA or XLR line-level connection from the receiver or preamp to the subwoofer.
NOTE: BE SURE TO CONNECT BLACK TO
BLACK AND RED TO RED.
Step 2:
LINE OUT (RCA): An RCA line-level (female) output is
provided for connection to a second subwoofer. Use a standard shielded coaxial cable for connection of the RCA Line Out to the second subwoofer.
Step 3:
VOLUME: Set this midway to the 9 o’clock position for initial
setup. You can use this to manually regulate the subwoofer volume at any time and during your initial setup adjustments with the other speakers in your stereo or home theater system.
Step 4:
X-OVER FREQUENCY: If you are using the Bass Management
crossover menu settings in your A/V receiver or processor, turn this control to 120 Hz to eliminate the EP350 v3 internal crossover from the circuit.
If you are using the HIGH LEVEL (Speaker Level) binding­post inputs, set the crossover switch to 80 Hz for initial setup. If you have oor-standing speakers (M50 v2, M60 v2, or M80 v2), try a 60 Hz crossover frequency. If your main speakers are bookshelf models M3 v2 or M22 v2, try the 80 Hz setting, for the M2 v2 tr y 100 Hz. Ultimately you want to use a crossover frequency that produces the smoothest blend of sound between the subwoofer and your main speakers.
Step 5:
POWER INDICATOR: e LED Power indicator glows Green
when it’s on and Red indicating Standby Mode.
Loading...