AXING SKP 2-10 User Manual

Page 1
SKP 2-10
OPERATION INSTRUCTIONS
QPSK | PAL Stereo Twin Module
Page 2
Operation Instructions
Safety regulations
Assembly, installation and service must be carried out by authorized and skilled electricians.
Switch off facility operating voltage or pull out mains plug before starting assembly or service
work.
Facility assembly:
In dust-free, dry environment, protected against humidity, vapors, splash water and moisture.
In a location protected against solar radiation. Not within close distance of heat sources. In ambient temperature of <50°C.
Ensure sufficient ventilation of the device. Do not cover the ventilation slots! - Avoid short
circuits!
Damages arising from incorrect connection and/or improper operation are excluded from any
liability.
Please observe all relevant standards, regulations and guidelines regarding installation and
operation of antenna facilities.
Ground SAT earth stations using equipotential bonding rails according to DIN EN 50083 and
VDE 0855.
Do not carry out any installation and service work during thunderstorms.
§ 5 Protection against flight radio frequencies
Conductor-bound transmission of analogue signals (broadcast signals) must be set within the frequency ranges
1) between 112 megahertz and 125 megahertz until March 31, 2009 at the latest and
2) between 125 megahertz and 137 megahertz until December 31, 2010 at the latest.
Scope
This operating manual is valid for the QPSK-PAL module SKP 2-10.
2
© AXING AG • Swizzerland • Reserving change in design and type 16.02.12
Page 3
Operation Instructions
Contents
1 Common .............................................................................................................................................4
1.1 Scope of delivery ..................................................................................................................4
1.2 Description............................................................................................................................4
1.2.1 Display elements and connections ...................................................................5
2 Installation and connection ..............................................................................................................6
2.1 Installation and connection in a headend base unit..............................................................6
2.2 Single operation mode of SKP 2-10 .....................................................................................7
3 Programming .....................................................................................................................................8
3.1 First start-up..........................................................................................................................9
3.1.1 Selecting duct left .............................................................................................9
3.1.2 Setting output channel ......................................................................................9
3.1.3 Setting TV standard ..........................................................................................9
3.2 Programming input channels via OSD................................................................................10
3.3 On-Screen Programming....................................................................................................10
3.3.1 Channel list .....................................................................................................11
3.3.2 Info..................................................................................................................11
3.3.3 Configuration...................................................................................................11
3.4 Programming of the right sub channel................................................................................15
3.5 Exit the configuration ..........................................................................................................15
3.5.1 Modulator........................................................................................................15
3.5.2 Menu language ...............................................................................................16
3.5.3 Exit the configuration ......................................................................................17
3.6 Other functions ...................................................................................................................17
3.6.1 Setting the audio level ....................................................................................17
3.6.2 Change program.............................................................................................17
3.6.3 Display input signal quality..............................................................................17
4 Technical specifications .................................................................................................................18
4.1 Software Update.................................................................................................................18
16.02.12 © AXING AG • Swizzerland • Reserving change in design and type
3
Page 4
Operation Instructions SKP 2-10 Chapter 1: Common
1
Fig. 1: Front view
Common
Note
1.1 Scope of delivery
1 × Twin QPSK-PAL module SKP 2-10
1 × DC connection cable SKZ 4-00
1 × operating manual
The remote control and power supply unit are not included in scope of delivery of SKP 2-10. They are available optionally or integrated in the basic unit of SKS x-xx.
1.2 Description
The SKP 2-10 can either be operated in a headend basic unit SKS x-xx or in stand alone mode.The Twin cassette modules are QPSK converters, that convert all programs modulated according to the DVB-S standard and QPSK in two PAL modulated cable signals.
Each module has one digital SAT IF input and two RF outputs. The module include two ducts working dependently from each other. The left main channel is used to select the band, the level and the transponder. The sub channel uses the same preselected transponder as the main channel.
main channel
An SKP 2-10 module consists of a digital tuner, the digital signal processing and an two output modulators.
The programming of the modules is done separately for each duct. Each duct can be levelled via OSD menu (on screen display). Processed input signals are led to the active output combiner of the headend through RF output connectors..
sub channel
4
© AXING AG • Swizzerland • Reserving change in design and type 16.02.12
Page 5
Operation Instructions SKP 2-10 Chapter 1: Common
1.2.1 Display elements and connections
Fig. 2: Display elements and connections
1. Programming selection switch (main channel– position left, sub channel – position right). After completed programming, the switch must be in center position!
2. Display channel number
3. Display point special channels
4. LED display MPEG data stream Orange = MPEG data stream present, Off = MPEG data stream not present
5. SAT IF input
6. USB input for software update
7. RF output and DC input (for installation in basic unit)
8. DC input/output (only for single operation)
9. DC input/output (for the power supply of three more SKP 2-10 twin modules in single operation and not in SKS x-xx)
10. Audio/Video outputs (cinch/RCA) for monitor connection
11. Infrared receiver
12. Grounding screw
13. Fan
16.02.12 © AXING AG • Swizzerland • Reserving change in design and type
5
Page 6
Operation Instructions SKP 2-10 Chapter 2: Installation and connection
2
Fig. 3: Installation and connection in a headend base unit
Installation and connection
Important
The SKP 2-10 can either be operated in a headend basic unit SKS x-xx or in stand alone mode. SAT ZF signals of the LNB(s) are either transmitted through a multiswitch or directly to SAT ZF inputs.
The maximum admissible current per SAT-ZT input is 250 mA.
2.1 Installation and connection in a headend base unit
If the SKP 2-10 should operate in a headend basic unit SKS x-xx, the twin module is plugged in the output collection field c and fastened with screws. Each free slot may be used. The power supply of the module is provided by the output collection field.
Notes
6
© AXING AG • Swizzerland • Reserving change in design and type 31.05.12
For detailed information on the headend base unit, refer to whose operating instructions.
Before inserting or changing a module, pull the mains plug of the headends basic unit from the socket!
Ground the base plate in order to avoid dangerous overvoltages according to EN 50083-1, EN 60728­11:2010 (attention: risk of fire/death).
Page 7
Operation Instructions SKP 2-10 Chapter 2: Installation and connection
2.2 Single operation mode of SKP 2-10
Before installing modules, the power supply must be switched off. Ground the module acc. to EN 50083-1, EN 60728-11:2010 in order to avoid dangerous overvoltages (attention: risk of fire/death). Use the grounding screw attached to the device (see 12 in Fig. 2).
When using the SKP 2-10 in single operation mode, the power is supplied via the DC socket (see 9 in fig. 2 on page 5). A separate power supply unit SKZ 5-01 means of the DC loop-through. One DC connection cable SKZ 4-00 is included in the delivery of the SKP 2-10. Max. 4 pieces SKP 2-10 may be connected together in single operation mode.
Fig. 4: Assembly and connection of a single twin module
1
is required for it. More units are connected by
Fig. 5: Assembly and connection of up to four twin modules
In single operation mode of the SKP 2-10 the outputs of the twin cassettes must be combined together with splitters. The splitters (SKV 2..8-00) may be used in connection with F-double sockets (CFA 3-00).
1
SKZ 5-01 to supply up to 4 modules/SKZ 5-03 to supply up to 2 modules
31.05.12 © AXING AG • Swizzerland • Reserving change in design and type
7
Page 8
Operation Instructions SKP 2-10 Chapter 3: Programming
3
Fig. 6: Remote control
Programming
The programming of the modules is done by means of the remote control SKZ 10-00 included in the scope of delivery of SKS x-xx.
Select main menu
Close the menu
Numeric bottuns
Channel information
Confirm selection
Decrease audio level
Increase audio level
Add or remove programs to output
Display BER (Bit error rate)
Select channel list
Scroll through channel list upwards side by side
Scroll through channel list downwards side by side
Channel change upwards
Channel change downwards
Setting output channel
8
© AXING AG • Swizzerland • Reserving change in design and type 16.02.12
Page 9
Operation Instructions SKP 2-10 Chapter 3: Programming
3.1 First start-up
During initial operation of the SKP 2-10 one must set first all output channels and the relevant TV standard must be set!
3.1.1 Selecting duct left
To be able to program the left duct of the Twin module, the programming selection switch must be moved to the left.
After pressing the UHF key on the remote control, a point lights up at the bottom right corner of the display of the left duct.
This shows that the modulator is in programming mode.
A test image and test sound are switched on.
3.1.2 Setting output channel
By pressing the CH /CH key, the desired output channel may be set.
Special channels are labeled by a 2nd dot between the digits on the display.
3.1.3 Setting TV standard
To set the TV standard, the SYS key (on the remote control) must be pressed until the desired TV standard is set.
TV standard Display
BG b6
I i
DK d
L l
NM mn
These settings must be saved with the OK key..
To discard settings, press the EXIT key. Programming mode is ended. Test image and test sound are turned off.
After finishing the programming, the programming selection switch must be moved to the centre position.
Programming of the right duct is done identically as for the left duct.
16.02.12 © AXING AG • Swizzerland • Reserving change in design and type
9
Page 10
Operation Instructions SKP 2-10 Chapter 3: Programming
3.2 Programming input channels via OSD
After programming the output channels of the SKP 2-10, the starting window will be displayed. A measuring device or a TV receiver must be connected to the output of the SKP 2-10 or the active output combiner and must be aligned with the respective output channel..
Fig. 7: Start window
Serial number and software version of the respective twin module is displayed.
The set output channel is shown on the Display.
Fig. 8: Preprogramming
Fig. 9: Main menu
As some channels are pre-programmed in the modules, a pre-set channel is opened. Information about SAT position, frequency, symbol rate, FEC and VPID is shown. The image of the channel is only visible, if the head end is configured for this satellite.
If no pre-programming exists, the starting window (see Fig. 7) is displayed permanently..
3.3 On-Screen Programming
The module to be programmed can be selected by means of the programming selection switch.
The measuring device must be aligned to the respective output channel. If a monitor is used, it must be connected to the respective duct via the AV-Cinch outputs of the module. (Cinch/RCA cables or cinch/RCA to scart cables)
After pressing the menu key, the main menu opens.
The desired menu item is selected by means of the CH / CH ▼key.
10
© AXING AG • Swizzerland • Reserving change in design and type 16.02.12
Page 11
Operation Instructions SKP 2-10 Chapter 3: Programming
3.3.1 Channel list
Select the menu item “Channel list” and confirm with OK. If a pre-programmed channel list is included within the module, the following selection appears.
Fig. 10: Channel list
Fig. 11: Info
On this list all pre-programmed channels appear with the current position of the satellite (A, B, C or D), transponder frequency, band information, name of the channel as well as program status (FTA/CA).
To be able to display encoded (CA = Conditional Access) programs, please use our twin module
!
SKP 2-00 with CI slot.
The desired receiving channel can be selected using the CH /CH keys or by scrolling
using
After pressing the OK key, the channel is applied, the menu closed and the image displayed.
By pressing the EXIT key, the menu is closed without accepting the receiving channel.
/ .
3.3.2 Info
Select menu item “Info” and confirm with OK.
The current software as well as the serial number of the module are displayed.
3.3.3 Configuration
Select menu item “Configuration” and confirm with OK.
Fig. 12: Configuration
16.02.12 © AXING AG • Swizzerland • Reserving change in design and type
11
Page 12
Operation Instructions SKP 2-10 Chapter 3: Programming
The picture below shows all possible options of the configuration menu.
Fig. 13: Possible settings
Selection submenu Audio Language
Fig. 14: Audio menu
With VOL selected language).
/ VOL  preset languages are selected (The broadcasting service must support the
Selection of regional windows in the sub menu Subtitles Language
By means of VOL regional window.
/ VOL  you can switch to this regional window if these channels offer a so-called
OFF: As soon as the selected channel offers a regional window, the channel switches over to it during transmission; after having closed the regional window, the main program runs again.
eng or another language code: The regional window is ignored; the main program of the corresponding channel is always transmitted.
Selection submenu Control Mode for Scan
With VOL The following selection is possible:

/ VOL

, the desired LNB setting is selected. This setting is used during satellite scanning.
Low vertical, low horizontal
High vertical and high horizontal.
Universal LNB
Toneburst
DiSEqC 1.0
DiSEcQ 1.0 - A • DiSEcQ 1.0 - B
DiSEcQ 1.0 - C • DiSEcQ 1.0 - D
In case of a Single-LNB, the selection must be set to "Universal LNB".
.
12
© AXING AG • Swizzerland • Reserving change in design and type 16.02.12
Page 13
Operation Instructions SKP 2-10 Chapter 3: Programming
Selection submenu Scan Satellite
Scanning satellites is very time consuming. If only certain programs are to be scanned, the option "Scan Transponder" should be selected.
The menu item is activated by pressing the OK key.
Programs are searched in the selected satellite based on the settings of "Control Mode for Scan". When selecting a certain LNB level, like Low horizontal etc. only this level will be scanned. Other settings, such as Universal LNB, result in the entire satellite being searched.
Fig. 15: Scanning a satellite
The progress is shown in the lower part of the display. After completion, the message "Satellite searched" appears. The new programs are saved at the end of the program list and can now be loaded.
Fig. 16: LNB Control Mode
Fig. 17: Submenu scan transpondern
Selection submenu LNB Control Mode

/ VOL

With VOL selected. In case of "Power off", all LNB settings are ignored. No control signals are generated.
, the desired LNB supply is selected. Either "Normal" or "Power off" can be
If a Quattro LNB is connected, the LNB supply of all connected ducts must be set to "Normal".
Selection submenu Scan Transponder
The menu item is activated by pressing the OK key.
Transponder data are entered by means of the CH /CH keys on the remote control.

/ VOL

A selection of parameters is pre-programmed. With VOL
, the desired parameter is selected.
16.02.12 © AXING AG • Swizzerland • Reserving change in design and type
13
Page 14
Operation Instructions SKP 2-10 Chapter 3: Programming
Special values can be entered directly via the numerical field on the remote control. With activated DiSEqC control, the respective satellite 1 to 4 is selected with Sat ID. After entering the transponder data, the search is started by pressing on scan.
Fig. 18: Display scan transponder
The status is shown in the lower part of the on screen display. After a positive search, the programs found will be added to the end of the program list and can be loaded.
Selection submenu Clear Program List
The menu item is activated by pressing the OK key.
Fig. 19: Submenu delete program list
Fig. 20: Submenu Add Default Channels
Selection submenu Add Default Channels
The menu item is activated by pressing the OK key. The program list stored in the factory is reset.
14
© AXING AG • Swizzerland • Reserving change in design and type 16.02.12
Page 15
Operation Instructions SKP 2-10 Chapter 3: Programming
3.4 Programming of the right sub channel
Programming selection switch must be set to CH2.
By pressing the menu button, the main menu is opened. Then select Configuration to enter the configuration menu.
Fig. 21: configuration menu sub channel
In the menu item "Scan Transponder", a program list of the preset transponder in the left main channel is created and stored in the menu item Channel list.
In the menu item "Channel list", a program for the sub channel can be selected.
After having selected the program by pressing the OK button, the configuration menu is
!
automatically closed.
During a successful transponder search, the existing channel list is automatically deleted and overwritten by a new channel list.
Fig. 22: Modulator
Fig. 23: Modulator-Menü
3.5 Exit the configuration
The configuration is closed by pressing “EXIT”
3.5.1 Modulator
Select the menu item “Modulator” and confirm with OK.
The desired output channel can be selected by means of the VOL in the display of SKP 2-10.
16.02.12 © AXING AG • Swizzerland • Reserving change in design and type

/ VOL

keys. This is also shown
15
Page 16
Operation Instructions SKP 2-10 Chapter 3: Programming
Selection submenu TV standard
The submenu is loaded by means of the CH
The TV standard line is then displayed with colored background.
The desired TV standard can be selected by means of the VOL standard, additional audio settings can be made. The audio signal is mono in all other standards.
/CH  keys.

/ VOL

keys. In BG and DK
Selection submenu audio mode
After selecting the submenu audio mode by means of the CH mono and stereo in the BG or DK standard.
/CH keys, you can choose between
All setting possibilities described above are shown in the following image.
Fig. 24: Selection in the modulator menu
Selection submenu Output Level
After selecting the “Output Level” submenu by means of the CH

be changed in 1dB steps by means of the VOL
20 equals an output level of 105 dBµV. The maximum level decrease is –20dB (equals = 0)..
/ VOL

keys.
/CH  keys, the the modulator can
Fig. 25: Menu language
Selection submenu Fine Tune adjustment
If the output channel does not correspond to the CCIR pattern, the output frequency can be changed and adjusted in steps of 250 kHz. The adjustment range is +/- 4 MHz.

/ VOL

The setting is done by means of the VOL
Exit modulator menu
After pressing the EXIT key, the menu is closed and all settings are saved.
keys.
3.5.2 Menu language
Select the menu item “Menu language” and confirm with OK.

/ VOL

After selecting this menu item, the menu language can be changed with theVOL
keys.
16
© AXING AG • Swizzerland • Reserving change in design and type 16.02.12
Page 17
Operation Instructions SKP 2-10 Chapter 3: Programming
3.5.3 Exit the configuration
Fig. 26: Exit the configuration
Select the menu item “Exit” and confirm with OK.
After selecting the menu item “Exit”, the programming is ended. All settings are saved.
After exit the programming, the programming selection switch must be set to centre position
3.6 Other functions
Additional settings can be made without starting the main menu..
3.6.1 Setting the audio level
Fig. 27: Setting the audio level
Fig. 28: Kanalliste
The audio level at the RF output can be adjusted using the VOL

/ VOL

keys.
3.6.2 Change program
The received program can be changed according to the program list using the CH  / CH keys.
The desired program can be selected from the list by means of the CH  /CH  keys.
After pressing the “OK” key, the program is applied. Additional program information can be loaded by means of the “INFO” key.
3.6.3 Display input signal quality
After pressing the “F1” key, the quality of the input signal is displayed.
Fig. 29: Quality of the input signal
The display is closed by pressing “EXIT”
16.02.12 © AXING AG • Swizzerland • Reserving change in design and type
17
Page 18
Operation Instructions SKP 2-10 Chapter 4: Technical specifications
4
Technical specifications
Article SKP 2-10
Part No. SKP00210
Ducts 2
Receivers 1
Input
Input frequency range 950…2150 MHz
Input level -70 … -25 dBm / 39...84 dBµV
LNB voltage 13/17 V; 22 kHz on/off; DiSEqC 1.0
Modulation process QPSK (SCPC, MCPC)
Symbol rate 2…45 MS/s
Error correction automatisch
Transport stream MPEG-2 ISO/IEC 13818
Teletext Through VBI
Subtitling DVB oder Teletext
Connector F-Buchse
Output
Output frequency range 112,25…855,25 MHz
Output channels S2…K69, nachbarkanaltauglich (VSB)
Modulation AM, VSB, A2 stereo
Transmission standard B/G, D/K, I, L, M/N
Output level 85…105 dBµV
Spurious products < 60 dBc
S/N weighted 55 dB
Common
Data interface USB 1
Power consumption 16V=/1,2A
Dimensions appr. 72 mm × 218mm × 129mm
4.1 Software Update
Each SKP 2-00 Twin cassette has a USB 1 connector for updating software. The programming specifications and the current software can be found on the AXING homepage under www.axing.com.
18
© AXING AG • Swizzerland • Reserving change in design and type 16.02.12
Page 19
Operation Instructions SKP 2-10 Chapter 4: Technical specifications
16.02.12 © AXING AG • Swizzerland • Reserving change in design and type
19
Page 20
Operation Instructions SKP 2-10 Chapter 4: Technical specifications
20
© AXING AG • Swizzerland • Reserving change in design and type 16.02.12
Loading...