axing HKI 41-34, HKI 41-35, HKI 81-34 Operation Instructions Manual

HKI 41-34 | HKI 41-35 HKI 81-34 | HKI 81-35
IPTV Encoders
Operation instructions
Operation instructions | HKI 41-34 | HKI 41-35 | HKI 81-34 | HKI 81-35
2 2017-07-25 | Technical changes, design modifications, errors and misprints are subject to change without prior notice.
Table of contents
1.1. General.................................................................................................................................................. 4
1.2. Scope of delivery ................................................................................................................................... 4
1.3. Connectors on the rear side .................................................................................................................. 4
1.4. Typical Application................................................................................................................................. 5
2. Mounting and Installation ............................................................................................................................. 6
3. IP integration ................................................................................................................................................. 7
3.1. Default IP addresses and logins:............................................................................................................ 7
3.2. Change the IP addresses into the required IP address space ................................................................. 7
4. Configuration............................................................................................................................................... 10
4.1. Maintenance ....................................................................................................................................... 10
4.1.1. Network ...................................................................................................................................... 10
4.1.2. Change password ....................................................................................................................... 10
4.1.3. Upgrade ...................................................................................................................................... 11
4.1.4. Reset ........................................................................................................................................... 11
4.2. Status of the Encoders ......................................................................................................................... 11
4.2.1. Stream URL of the encoders ........................................................................................................ 12
4.2.2. Substream URLs of the encoders ................................................................................................. 12
4.3. Encoder Se ttings.................................................................................................................................. 13
4.3.1. Main stream ................................................................................................................................ 13
4.3.2. Substream1…3 ........................................................................................................................... 14
4.3.3. Audio settings ............................................................................................................................. 14
4.3.4. Advanced .................................................................................................................................... 15
4.4. OSD Setting ......................................................................................................................................... 15
4.4.1. Streaming OSD Setting ................................................................................................................ 15
4.4.2. Substream1…3 ........................................................................................................................... 16
4.4.3. LOGO uploading ......................................................................................................................... 16
5. Application examples .................................................................................................................................. 17
5.1. Preview with the stream with Windows Media Player ........................................................................ 17
5.2. Multi Local User Application Multicast Way ........................................................................................ 18
5.3. Local Surveillance System Application NVR Connection ...................................................................... 19
5.4. Remote Multi User Application RTMP Connection............................................................................... 20
6. Technical spe cifications ............................................................................................................................... 22
2017-07-25 | Technical changes, design modifications, errors and misprints are subject to change without prior notice. 3
Safety instructions:
The installation of the device and repair work on the device must be carried out only by a professional
in accordance with the applicable VDE directives. In case of incorrect installation, no liability is assumed.
Never open the device. There are no parts to be maintained by the user inside the device, however,
lethal voltages are present. This also applies to cleaning the device or working on the connections.
Use only the mains cable connected to the device or the enclosed power supply unit. Never replace any
parts or make any modifications to the mains cable and the power supply unit. Otherwise, there is a risk of death.
If a replaceable fuse is available, pull out the mains plug before replacing the fuse. Replace defective
fuses only by standardized fuses with the same nominal value.
If you intend not to use the device for a longer period of time, we recommend you to completely
disconnect the device from the mains for safety reasons and for saving energy by pulling out the mains plug.
Let the device adjust to the room temperature before commissioning, in particular if condensation is
present on the device, or if it was exposed to large temperature fluctuations.
The device must be operated only in moderate climate. The device must be operated only in dry rooms. In damp rooms or outdoors, there is a risk of short-
circuits (attention: risk of fire) or electrical shocks (attention: risk of death).
Plan the mounting or installation location such that you can easily reach the mains plug and interrupt
the electric circuit in dangerous situations. Select the mounting or installation location such that children cannot play near the device and its connections without supervision. The mounting or installation location must allow a safe installation of all connected cables. Power supply cables and supply cables must not be damaged or squeezed by any objects.
Select a mounting or installation location which meets the requirements of the IP 54 protection class.
Operate the device only on a flat, firm surface and protect it against unintentional movements.
Never expose the device to direct solar irradiation and avoid direct vicinity of heat sources (e.g.
heaters, other electrical appliances, fireplace, etc.). It must be always ensured that devices with cooling elements or ventilation slots are not covered or obstructed. In addition, ensure generous air circulation around the device. This will prevent possible damage to device and risk of fire due to overheating. It must be always ensured that cables are not located near heat sources (e.g. heaters, other electrical appliances, fireplace, etc.).
The device is intended for transmission of audio and video signals via LAN cable. Misuse of the device
is expressly prohibited.
In particular, the warranty and liability shall be excluded for the consequences of incorrect use, in case
of incorrect modifications or repair work carried out by the customer. Use the device only as described in the operating instructions and in particular according to the state-of-the-art.
The antenna system must be installed and grounded according to the current DIN EN 60728-11
standard.
The product complies with the directives and standards for CE labeling.
Operation instructions | HKI 41-34 | HKI 41-35 | HKI 81-34 | HKI 81-35
4 2017-07-25 | Technical changes, design modifications, errors and misprints are subject to change without prior notice.
1. Product description
1.1. General
HKI 41-34 IPTV Encoder with H.264 coding
4 × HDMI
HKI 41-35 IPTV Encoder with H.265 (HEVC) coding
4 × HDMI
HKI 81-34 IPTV Encoder with H.264 coding
8 × HDMI
HKI 81-35 IPTV Encoder with H.265 (HEVC) coding
8 × HDMI
Common Features:
Web-based configuration | Remote maintenance Two redundant power supplies (hot pluggable)
1.2. Field of application:
The devices are only suitable for in-house distribution of HDMI signals over IPTV. If a device is used for other purposes, no warranty is given!
1.3. Scope of delivery
1 × IPTV Encoder
2 × AC connection cable, power cord
1 × Quick start guide
1.4. Connectors on the rear side
1. AC connectors of the power supplies
2. RJ-45 Ethernet port of the controler
3. RJ-45 Ethernet ports of Encoder 1…4
4. RJ-45 Ethernet ports of Encoder 5…8 (HKI 81-xx)
5. HDMI inputs 1…4
6. HDMI inputs 5…8 (HKI 81-xx)
2017-07-25 | Technical changes, design modifications, errors and misprints are subject to change without prior notice. 5
1.5. Typical Application
Operation instructions | HKI 41-34 | HKI 41-35 | HKI 81-34 | HKI 81-35
6 2017-07-25 | Technical changes, design modifications, errors and misprints are subject to change without prior notice.
2. Mounting and Installation
Installation may be performed by authorized and skilled electricians only.
Mounting and installation in a 19“rack
The IPTV encoders are mounted in a 19" rack Mount the unit with four fitting screws (1).
Equipotential bonding
The HKI must be connected to the equipotential bonding according to EN 60728-11.
Power supply
The HKI have two built-in power supply. Connect both power supplies to an electrical outlet (100 ... 240 VAC / 50 ... 60 Hz).
2017-07-25 | Technical changes, design modifications, errors and misprints are subject to change without prior notice. 7
3. IP integration
The HKI 41-3x includes 1 controler and 4 encoders
The HKI 81-3x includes 1 controler and 8 encoders
All this sub devices have to be in the same IP adress space, to communicate with each other.
3.1. Default IP addresses and logins:
The device is configured via the graphical user interface. To access the user interface, you need a standard PC/laptop with a network interface, a commercially available network cable and the actual version of the installed web browser.
IP adress User/password
Control port interface 192.168.0.157 admin/Ramsen8262
Encoder 1 192.168.0.161 admin/admin
Encoder 2 192.168.0.162 admin/admin
Encoder 3 192.168.0.163 admin/admin
Encoder 4 192.168.0.164 admin/admin
Encoder 5 192.168.0.165 admin/admin
Encoder 6 192.168.0.166 admin/admin
Encoder 7 192.168.0.167 admin/admin
Encoder 8 192.168.0.168 admin/admin
3.2. Change the IP addresses into the required IP address space
If the address space of your network does not match that of the HKI (192.168.0.xyz), change the encoder IP addresses step by step into the required IP address space.
1st Step – change encoders IP addresses in required IP address space.
Configure your computer in to the same IP address space as the default IP addresses of the encoders.
For example: 192.168.0.50
Enter via browser the encoder web interfaces one by one and configure them in to the required address
space.
For example:
Encoder 1: 192.168.178.110
Encoder 3: 192.168.178.112
Encoder 5: 192.168.178.114
Encoder 7: 192.168.178.116
Encoder 2: 192.168.178.111
Encoder 4: 192.168.178.113
Encoder 6: 192.168.178.115
Encoder 8: 192.168.178.117
Operation instructions | HKI 41-34 | HKI 41-35 | HKI 81-34 | HKI 81-35
8 2017-07-25 | Technical changes, design modifications, errors and misprints are subject to change without prior notice.
2nd Step – change the control port IP address in the required IP address space.
Enter via browser the control port web interface (192.168.0.157) and configure it also in to required address
space.
For example: 192.168.178.100 it must be in the same IP-adress space.
Note: After this the connection to the controller is interrupted.
3rd Step – assign the encoder IP addresses in the control port web interface
Configure your computer to the same IP address space as the encoders and the controller.
For example: 192.168.178.50
Enter via browser the web interface of the controller (192.168.178.100).Choose MAINTENANCE>Network>Encoder IP addressesType in the changed encoder IP addresses.
For example: – Encoder 1: 192.168.178.110
– Encoder 2: 192.168.178.111 – Encoder 3: 192.168.178.112 – Encoder 4: 192.168.178.113 – Encoder 5: 192.168.178.114 – Encoder 6: 192.168.178.115 – Encoder 7: 192.168.178.116 – Encoder 8: 192.168.178.117