3. PROGRAMMING OF TELEPHONE NUMBERS* AND CODES
* Only if direct buttons (ADI-623-08) or PL1:6 are to be used
DI-623-21L has the possibility to store 99 codes and/or telephone numbers. These are
stored at fixed addresses, 101 to 199, and could be 1 to 14 digits. You should make a
log of what is stored at which address. Each code could be combined with one of two
functions:
< 1 > - Controls Relay 1 monostable.
< 2 > - Stores as telephone number.
You can also program the code/ direct buttons so they are possible to disable by an
external timer. The disable functions are:
< 0 > - No time control
< 1 > - Code disabled if PL2:15 PL2:16 is open.
< 2 > - Code disabled if PL2:15 PL2:16 is closed.
Programming is done in the following way:
- Enter your password. You will hear a beep every second.
- Press # and the address for the fist code/number which is 101, and you hear a
double beep.
- Enter a code/number with optional number of digits (max. 14).
- Press #, and you hear a double beep.
- Enter a function (1-2), and you hear a double beep.
- Enter a disable function (0-2), and you hear two short and one long. The code
is now stored in the memory and the unit returns to programming mode.
- Press *. The unit returns to working mode.
Example 1: Program a 3-digit telephone number (209), which should not be timecontrolled (0).
- Enter your password.
- Press # 101 209# 2 0
- Press *. The unit returns to working mode.