SAFETY WARNINGS/ISTRUZIONI PER LA SICUREZZA |FOREWORD
TIGER E5 · User Manual · ENG
SUMMARY
1. SAFETY WARNINGS/ISTRUZIONI PER LA SICUREZZA 4
FOREWORD 5
2. SAFETY WARNINGS 6
3. CONSIGNES DE SÉCURITÉ IMPORTANTES 8
4. ISTRUZIONI IMPORTANTI PER LA SICUREZZA 10
5. WICHTIGE SICHERHEITSHINWEISE 12
6. INSTRUCCIONES IMPORTANTES DE SEGURIDAD 14
7. UNPACKING AND INSPECTION 16
8. FIRST INSTALLATION RECOMMENDATIONS 17
POWER SUPPLY CABLE 17
PROTECTION AGAINST LIGHTNING 18
VENTILATION 19
9. DEVICE INSTALLATION 19
BEST SETUP LOCATION 19
POWER SUPPLY 19
10. DEVICE GENERAL DESCRIPTION 21
FRONT PANEL 21
REAR PANEL 21
11. FIRST DEVICE START 25
STARTING YOUR TIGER E5 - QUICK SETUP 25
11.1.1 HOME PAGE 26
LOGIN 28
LOGGED IN USER – HOME PAGE 29
SUMMARY MASK 30
SETUP 37
11.5.1 GENERAL SETUP 37
11.5.2 NETWORK 41
11.5.3 NTP 47
11.5.4 SNMP 49
11.5.5 SMTP 56
11.5.6 GPIO 60
11.5.7 GPS 64
11.5.8 SYSTEM TOOLS 65
ADMINISTRATION 68
11.6.1 USER CLASS – USER RIGHTS TO LOGIN THE SYSTEM 70
11.6.2 ADDING A NEW USER 74
11.6.3 REMOVING AN EXISTING USER 75
LOGS 75
11.7.1 DEBUG LOGS 76
11.7.2 USERS LOGS 76
11.7.3 EVENTS LOGS 76
11.7.4 NOTIFICATIONS LOGS 76
CONFIGURATION 76
RDS/RBDS 77
11.9.1 QUICK RDS SETUP 77
11.9.2 UECP PORTS 77
11.9.3 BASIC SETTINGS 83
11.9.4 STANDARD MODE 89
11.9.5 EXTENDED MODE 102
11.9.6 RDS BLOCKS ANALYSIS 109
AUDIO INPUT 110
11.10.1 SOURCES 110

SAFETY WARNINGS/ISTRUZIONI PER LA SICUREZZA |FOREWORD
TIGER E5 · User Manual · ENG
11.10.2 CHANGEOVER 121
11.10.3 AUDIO ANALYSIS 123
TIGER E5 WAYS OF USE 126
11.11.1 SINGLE AUDIO SOURCE WITH RDS GENERATION127
11.11.2 DOUBLE AUDIO SOURCES WITH AUDIO CHANGEOVER
128
11.11.3 MPX REBROADCAST WITH RDS REGENERATION +
UECP FILTER ON INCOMING RDS 129
11.11.4 DOUBLE AUDIO SOURCES WITH AUDIO CHANGEOVER.
MPX CHANGEOVER WITH MPX BACKUP SOURCE 130
11.11.5 DOUBLE AUDIO SOURCES WITH AUDIO CHANGEOVER.
MPX CHANGEOVER WITH MPX MAIN SOURCE 131
11.11.6 RDS GENERATOR CONFIGURATION 132
MPX 132
11.12.1 INTERNAL MPX ENCODER 132
11.12.2 CHANGEOVER 133
11.12.3 OUTPUTS 147
11.12.4 MPX ANALYSIS 148
MULTIMEDIA 150
11.13.1 STREAMER 150
12. WEEE DIRECTIVE – INFORMATIVA RAEE 160
13. WARRANTY 161
14. DECLARATION OF ROHS CONFORMITY 162
15. FINAL CONSIDERATIONS AND AXEL TECHNOLOGY
CONTACTS 163

SAFETY WARNINGS/ISTRUZIONI PER LA SICUREZZA |FOREWORD
TIGER E5 · User Manual · ENG
1. SAFETY WARNINGS/ISTRUZIONI PER LA SICUREZZA
_____________________________________________________________________________________________________________________
SAFETY WARNINGS
CONSIGNES DE SÉCURITÉ IMPORTANTES
ISTRUZIONI IMPORTANTI PER LA SICUREZZA
WICHTIGE SICHERHEITSHINWEISE
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
(Rel. 1.6)
_____________________________________________________________________________________________________________________

SAFETY WARNINGS/ISTRUZIONI PER LA SICUREZZA |FOREWORD
TIGER E5 · User Manual · ENG
FOREWORD
_____________________________________________________________________________________________________________________
For your own safety and to avoid invalidation of the warranty all text marked with these Warning Symbols should be read carefully.
_____________________________________________________________________________________________________________________
Information in this manual is subject to change without notice and does not represent a commitment on the part of the vendor.
The manufacturer shall not be liable for any loss or damage whatsoever arising from the use of information or any error contained in this manual, or through any mis-operation or
fault in hardware contained in the product.
It is recommended that all maintenance and service on the product should be carried out by the manufacturer or its authorised agents. The manufacturer cannot accept any
liability whatsoever for any loss or damage caused by service, maintenance or repair by unauthorised personnel

SAFETY WARNINGS |FOREWORD
TIGER E5 · User Manual · ENG
2. SAFETY WARNINGS
The installation and servicing instructions in this manual are for use by qualified personnel only.
Read All Instructions. All safety and operating instructions must be read before operating the product. They also must be retained for future reference, as it contains
a number of useful hints for determining the best combination of equipment settings for Yr particular application.
Heed All Warnings. All warnings on the product and those listed in the operating instructions must be adhered to.
Heat. This product must be situated away from any heat sources such as radiators or other products (including power amplifiers or transmitters) that produce
heat.
Power Sources. This product must be operated from the type of power source indicated on the marking label and in the installation instructions. If you are not sure of
the type of power supplied to your facility, consult your local power company. Make sure the AC main voltage corresponds to that indicated in the technical specifications.
If a different voltage (ex. 110/115 VAC) is available, open the equipment closure and set the voltage switch on the main supply circuit, located behind the AC socket
Power Cord Protection. Power supply cords must be routed so that they are not likely to be walked on nor pinched by items placed upon or against them. Pay
particular attention to the cords at AC wall plugs and convenience receptacles, and at the point where the cord plugs into the product
Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the
cart/apparatus combination to avoid injury from tip-over.
Lightning. For added protection for this product during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it from the AC wall
outlet and the audio connections. This will prevent damage to the product due to lightning and power line surges
Installation. Configuration and installation should only be carried out by a competent installation engineer
Cabling. Using high quality wires, well protected. Make sure the cable integrity.

SAFETY WARNINGS |FOREWORD
TIGER E5 · User Manual · ENG
This symbol alerts you to the presence of dangerous voltage inside the closure – voltage which may be sufficient to
constitute a risk of shock. Do not perform any servicing other than that contained in the operating instructions. Refer
all servicing to qualified personnel
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Do not change the voltage setting or replace the mains fuse without first turning the unit off and unplugging the
mains cord
Make sure the AC main voltage corresponds to that indicated in the technical specifications. THIS APPARATUS MUST BE
EARTHED !
To avoid risk of fire use the correct value fuse, as indicated on the label stuck on the right side of the unit.
This apparatus uses a single pole mains switch and does therefore not separate the unit completely from the
mains power. To completely separate from mains power (f.i. in the event of danger) unplug mains power cord. As the
MAINS plug is the disconnect device, the disconnect device shall remain readily operable.

CONSIGNES DE SÉCURITÉ IMPORTANTES |FOREWORD
TIGER E5 · User Manual · ENG
3. CONSIGNES DE SÉCURITÉ IMPORTANTES
Observer tous les avertissements
Suivre toutes les consignes
Ne pas utiliser cet appareil à proximité de l’eau
Ne pas obstruer les ouvertures de ventilation. Installer en respectant les consignes du fabricant
Ne pas installer à proximité d'une source de chaleur telle qu'un radiateur, une bouche de chaleur, un poêle ou d'autres appareils (dont les amplificateurs)
produisant de la chaleur.
Ne pas annuler la sécurité de la fiche de terre, la troisième branche est destinée à la sécurité. Si la fiche fournie ne s'adapte pas à la prise électrique,
demander à un électricien de remplacer la prise hors normes.
Protéger le cordon d'alimentation afin que personne ne marche dessus et que rien ne le pince, en particulier aux fiches, aux prises de courant et au point de
sortie de l’appareil
Utiliser uniquement les accessoires spécifiés par le fabricant
Utiliser uniquement avec un chariot, un support ou une table spécifié par le fabricant ou vendu avec l’appareil. Si un chariot est utilisé, déplacer l’ensemble
chariot–appareil avec précaution afin de ne pas le renverser, ce qui pourrait entraîner des blessures
Débrancher l’appareil pendant les orages ou quand il ne sera pas utilisé pendant longtemps.
Confier toute réparation à du personnel qualifié. Des réparations sont nécessaires si l’appareil est endommagé d’une façon quelconque, par exemple: cordon
ou prise d’alimentation endommagé, liquide renversé ou objet tombé à l’intérieur de l’appareil, exposition de l’appareil à la pluie ou à l’humidité, appareil qui ne marche
pas normalement ou que l’on a fait tomber.
NE PAS exposer cet appareil aux égouttures et aux éclaboussements. Ne pas poser des objets contenant de l'eau, comme des vases, sur l'appareil

CONSIGNES DE SÉCURITÉ IMPORTANTES |FOREWORD
TIGER E5 · User Manual · ENG
Ce symbole indique la présence d'une tension dangereuse dans l'appareil constituant un risque de choc électrique.
Ce symbole indique que la documentation fournie avec l'appareil contient des instructions d'utilisation et d'entretien
importantes.
Avant de modifier le commutateur de changement de tension ou replacer le fusible il faut débrancher l’appareil de la
prise électrique. Pendant son usage, l’appareil doit etre branchee à la prise de terre
Utiliser le fusible principal AC avec le valeur qui est indiquée sur l'étiquette collée sur le coffret
Assurez-vous que la tension principale AC correspond à celle indiquée dans les spécifications techniques.
L’interrupteur d’alimentation interrompt un pôle du réseau d’alimentation excepté le conducteur de terre de
protection. En cas de danger, debrancher le cordon d'alimentation. Parce que la prise du réseau de alimentation est
utilisée comme dispositif de déconnexion, ce dispositif doit demeuré aisément accessible

ISTRUZIONI IMPORTANTI PER LA SICUREZZA |FOREWORD
TIGER E5 · User Manual · ENG
4. ISTRUZIONI IMPORTANTI PER LA SICUREZZA
Leggere le presenti istruzioni
Conservare queste istruzioni
Osservare tutte le avvertenze
Seguire scrupolosamente tutte le istruzioni
Non usare questo apparecchio in prossimità di acqua
Non ostruire alcuna apertura per il raffreddamento. Installare l’apparecchio seguendo le istruzioni
Non installare l'apparecchio accanto a fonti di calore quali radiatori, aperture per l'afflusso di aria calda, forni o altri apparecchi (amplificatori inclusi) che generino
calore
Non rimuovere il terminale di connessione a terra sul cordone di alimentazione: esso ha lo scopo di tutelare l’incolumità dell’utilizzatore. Se la spina in dotazione
non si adatta alla presa di corrente, rivolgersi ad un elettricista per far eseguire le modifiche necessarie.
Evitare di calpestare il cavo di alimentazione o di comprimerlo, specialmente in corrispondenza della spina e del punto di inserzione sull’apparato.
Utilizzare solo dispositivi di collegamento e gli accessori specificati dal produttore.
Utilizzare l’apparecchio solo con un carrello, un sostegno, una staffa o un tavolo di tipo specificato dal produttore o venduto insieme all’apparecchio. Se si utilizza un
carrello, fare attenzione negli spostamenti per evitare infortuni causati da ribaltamenti del carrello stesso.
Scollegare l’apparecchio dalla presa di corrente durante i temporali o quando inutilizzato a lungo
Per qualsiasi intervento, rivolgersi a personale di assistenza qualificato. È’ necessario intervenire sull’apparecchio ogniqualvolta si verificano danneggiamenti di qualsiasi
natura. Ad esempio, la spina o il cavo di alimentazione sono danneggiati, è entrato liquido nell’apparecchio o sono caduti oggetti su di esso, l’apparecchio è stato
esposto alla pioggia o all’umidità, non funziona normalmente o è caduto.
Non esporre a sgocciolamenti o spruzzi. Non appoggiare sull'apparecchio oggetti pieni di liquidi, ad esempio vasi da fiori.

ISTRUZIONI IMPORTANTI PER LA SICUREZZA |FOREWORD
TIGER E5 · User Manual · ENG
Questo simbolo indica la presenza di alta tensione all'interno dell'apparecchio, che comporta rischi di scossa elettrica.
Questo simbolo indica la presenza di istruzioni importanti per l'uso e la manutenzione nella documentazione in
dotazione all'apparecchio.
Non sostituire il fusibile o cambiare la tensione di alimentazione senza aver prima scollegato il cordone di
alimentazione. L’APPARATO DEVE ESSERE CONNESSO A TERRA.
Sostituire il fusibile generale con uno di identico valore, come indicato sulla etichetta applicata sul mobile
dell’apparato
Assicurarsi che la tensione di rete corrisponda a quella per la quale è configurato l’apparecchio
Questo apparato utilizza un interruttore di alimentazione di tipo unipolare e l’isolamento dalla rete elettrica non è pertanto completo. Per ottenere
un isolamento totale (ad esempio in caso di pericolo), scollegare il cordone di alimentazione. Inoltre, poichè la spina di alimentazione è
utilizzata come dispositivo di sezionamento, essa deve restare facilmente raggiungibile

WICHTIGE SICHERHEITSHINWEISE |FOREWORD
TIGER E5 · User Manual · ENG
5. WICHTIGE SICHERHEITSHINWEISE
Alle Warnhinweise BEACHTEN
Alle Anweisungen BEFOLGEN
Dieses Gerät NICHT in der Nähe von Wasser verwenden
KEINE Lüftungsöffnungen verdecken. Gemäß den Anweisungen des Herstellers einbauen
Nicht in der Nähe von Wärmequellen, wie Heizkörpern, Raumheizungen, Herden oder anderen Geräten (einschließlich Verstärkern) installieren, die Wärme
erzeugen
Die Schutzfunktion des Schukosteckers NICHT umgehen. Bei Steckern für die USA gibt es polarisierte Stecker, bei denen ein Leiter breiter als der andere ist; USStecker mit Erdung verfügen über einen dritten Schutzleiter. Bei diesen Steckerausführungen dient der breitere Leiter bzw. der Schutzleiter Ihrer Sicherheit. Wenn der
mitgelieferte Stecker nicht in die Steckdose passt, einen Elektriker mit dem Austauschen der veralteten Steckdose beauftragen
VERHINDERN, dass das Netzkabel gequetscht oder darauf getreten wird, insbesondere im Bereich der Stecker, Netzsteckdosen und an der Austrittsstelle vom
Gerät
NUR das vom Hersteller angegebene Zubehör und entsprechende Zusatzgeräte verwenden.
NUR in Verbindung mit einem vom Hersteller angegebenen oder mit dem Gerät verkauften Transportwagen, Stand, Stativ, Träger oder Tisch verwenden. Wenn ein
Transportwagen verwendet wird, beim Verschieben der Transportwagen-Geräte- Einheit vorsichtig vorgehen, um Verletzungen durch Umkippen
Das Netzkabel dieses Geräts während Gewittern oder bei längeren Stillstandszeiten aus der Steckdose ABZIEHEN.
Alle Reparatur- und Wartungsarbeiten von qualifiziertem Kundendienstpersonal DURCHFÜHREN LASSEN. Kundendienst ist erforderlich, wenn das Gerät auf
irgendwelche Weise beschädigt wurde, z.B. wenn das Netzkabel oder der Netzstecker beschädigt wurden, wenn Flüssigkeiten in das Gerät verschüttet wurden oder
Fremdkörper hineinfielen, wenn das Gerät Regen oder Feuchtigkeit ausgesetzt war, nicht normal funktioniert oder fallen gelassen wurde.
Dieses Gerät vor Tropf- und Spritzwasser SCHÜTZEN. KEINE mit Wasser gefüllten Gegenstände wie zum Beispiel Vasen auf das Gerät STELLEN.

WICHTIGE SICHERHEITSHINWEISE |FOREWORD
TIGER E5 · User Manual · ENG
Dieses Symbol zeigt an, dass gefährliche Spannungswerte, die ein Stromschlagrisiko darstellen, innerhalb dieses Geräts
auftreten
Dieses Symbol zeigt an, dass das diesem Gerät beiliegende Handbuch wichtige Betriebs- und Wartungsanweisungen
enthält.
Vor Änderung der Netzspannung oder Sicherungswechsel Netzkabel trennen. Das Gerät muss für den Betrieb geerdet
werden.
Hauptsicherung nur mit einer gleichwertigen austauschen (s. entsprechende Etikette).
Vor Einschalten Netzspannungseinstellung am Gerät überprüfen bzw. anpassen.
Inpoliger Netzschalter. In Notfälle oder für Wartungsarbeiten Netzkabel trennen. Der Netzstecker fungiert auch als Trennelement muss deshalb
zugänglich bleiben

INSTRUCCIONES IMPORTANTES DE SEGURIDAD |FOREWORD
TIGER E5 · User Manual · ENG
6. INSTRUCCIONES IMPORTANTES DE SEGURIDAD
CONSERVE estas instrucciones
PRESTE ATENCION a todas las advertencias.
SIGA todas las instrucciones
NO utilice este aparato cerca del agua
NO obstruya ninguna de las aberturas de ventilación. Instálese según lo indicado en las instrucciones del fabricante
No instale el aparato cerca de fuentes de calor tales como radiadores, registros de calefacción, estufas u otros aparatos (incluyendo amplificadores) que
produzcan calor
NO anule la función de seguridad del enchufe polarizado o con clavija de puesta a tierra. Un enchufe polarizado tiene dos patas, una más ancha que la otra. Un
enchufe con puesta a tierra tiene dos patas y una tercera clavija con puesta a tierra. La pata más ancha o la tercera clavija se proporciona para su seguridad. Si el toma
corriente no es del tipo apropiado para el enchufe, consulte a un electricista para que sustituya el toma corriente de estilo anticuado
PROTEJA el cable eléctrico para evitar que personas lo pisen o estrujen, particularmente en sus enchufes, en los toma corrientes y en el punto en el cual sale del
aparato
UTILICE únicamente los accesorios especificados por el fabricante
UTILICESE únicamente con un carro, pedestal, escuadra o mesa del tipo especificado por el fabricante o vendido con el aparato. Si se usa un carro, el mismo debe
moverse con sumo cuidado para evitar que se vuelque con el aparato
DESENCHUFE el aparato durante las tormentas eléctricas, o si no va a ser utilizado por un lapso prolongado.
TODA reparación debe ser llevada a cabo por técnicos calificados. El aparato requiere reparación si ha sufrido cualquier tipo de daño, incluyendo los daños al
cordón o enchufe eléctrico, si se derrama líquido sobre el aparato o si caen objetos en su interior, si ha sido expuesto a la lluvia o la humedad, si no funciona de modo
normal, o si se ha caído.
NO exponga este aparato a chorros o salpicaduras de líquidos. NO coloque objetos llenos con líquido, tales como floreros, sobre el aparato .

INSTRUCCIONES IMPORTANTES DE SEGURIDAD |FOREWORD
TIGER E5 · User Manual · ENG
Este símbolo indica que la unidad contiene niveles de voltaje peligrosos que representan un riesgo de choques
eléctricos.
Este símbolo indica que la literatura que acompaña a esta unidad contiene instrucciones importantes de
funcionamiento y mantenimiento.
Antes de cambiar la alimentacion de voltaje o de cambiar el fusible, desconecte el cable de alimentacion. Para
reducir el riesgo de descargas electricas, esta unidad debe ser conectada a tierra.
Remplaze el fusible con lo mismo, que corresponde a lo indicado en el panel del equipo.
Antes de encender, controlar que la linea de alimentacion de voltaje corresponda a la indicada
El interruptor de alimentación es unipolar. En el caso de peligro, desconecte el cable de alimentación. Porque la clavija de conexion a red sirve
por la desconection de la unidad, la clavija debe ser ubicada en proximidad de la unidad

UNPACKING AND INSPECTION |FOREWORD
TIGER E5 · User Manual · ENG
7. UNPACKING AND INSPECTION
Your equipment was packed carefully at the factory in a container designed to protect the unit during shipment. Nevertheless, we recommend making a careful inspection of the
shipping carton and the contents for any signs of physical damage.
Damage & Claims
If damage is evident, do not discard the container or packing material. Contact your carrier immediately to file a claim for damages. Customarily, the carrier requires you, the consignee,
to make all damage claims. It will be helpful to retain the shipping documents and the waybill number.
Save all packing materials! If You should ever have to ship the unti (e.g. for servicing), it is best to ship it in the original carton with its packing materials because both the carton and
packing material have been carefully designed to protect the unit.
Under normal conditions no user maintenance or calibration are required. Internal links and preset controls may be set to configure the unit during installation. Any service work
required should be carried out by qualified service personnel only.
We are able to offer further product support through our worldwide network of approved dealers and service agents.
To help us provide the most efficient service please would you keep a record of the unit serial number, and date and place of purchase to be quoted in any communication
regarding this product.
The actual equipment Serial Number is indicated on the silver label stuck on the rear panel of the equipment closure.
Tools And Equipment Needed
Only standard technician’s tools are required to install this equipment

FIRST INSTALLATION RECOMMENDATIONS |POWER SUPPLY CABLE
TIGER E5 · User Manual · ENG
8. FIRST INSTALLATION RECOMMENDATIONS
POWER SUPPLY CABLE
A power supply cable of approx. 2 mt length is supplied with the device, which has a moulded IEC plug attached – this is a legal requirement.
The type of plug for the power supply depends on the country in which it is delivered.
If for any reason, you need to use this appliance with a different plug, you should use the following wiring guidelines in replacing the exsisting plug with the new one:
Green, or green and yellow
Supply cables should be laid in such a manner that one does not step or walk on them. They should not be squashed by any objects.
THIS EQUIPMENT MUST BE EARTHED.
The chassis is always connected to mains earth to ensure your safety: check your mains wiring and earthing before switching on.

FIRST INSTALLATION RECOMMENDATIONS |PROTECTION AGAINST LIGHTNING
TIGER E5 · User Manual · ENG
PROTECTION AGAINST LIGHTNING
Should the device be put out of action due to being struck by lightning or excess voltage, disconnect it from the power supply
without delay. Do not reconnect until the device has been checked. If in doubt contact the technical support service.
Make sure there is suitable lightning protection to protect the device.
Alternatively you should disconnect all connectors from the device during a storm or when the device is going to be
unsupervised or not used for a longer period of time.
These measures will protect against damage by lightning or excess voltage.

DEVICE INSTALLATION |VENTILATION
TIGER E5 · User Manual · ENG
VENTILATION
The equipment will operate as a free-standing unit without requiring any special cooling arrangement.
However, slots and openings in the product are provided for ventilation. They ensure reliable operation of the product, keeping it from overheating. These openings must not be
blocked nor covered during operation.
YOU MUST LEAVE AT A MINIMUM ONE RACK UNIT OF EMPTY SPACE ABOVE THE EQUIPMENT TO ENHANCE VENTILATION AND TO GET A LONGER EQUIPMENT LIFE.
9. DEVICE INSTALLATION
BEST SETUP LOCATION
The device should be installed in a 19” rack. Avoid direct sunlight, close proximity to radiators and air conditioning, dust, water, and chemicals. Choose a rack location that permits
a clear view to the indicators on the device and ensure a sufficient heat dissipation of the device.
POWER SUPPLY
The device is designed for operation with 100 to 240 V AC, 50 Hz to 60 Hz. Check the corresponding device labelling for compatibility to the domestic line voltage and frequency
before connecting the IEC power connector to the mains supply!
WARNING
Disconnect mains power plug before you open the housing. Repair of the
equipment must only be carried out by authorized and qualified personnel.

DEVICE INSTALLATION |POWER SUPPLY
TIGER E5 · User Manual · ENG
Please make sure that the device and the contained fuse(s) (please see
p. 20) are compatible to the domestic line voltage and frequency. If the
device is compatible, connect the power supply cord fully to the IEC
power connector at the rear side of the device and a mains power
outlet. The “LCD Screed” will then turn on.
For delivery, the device is configured with default settings for the first
connection via the IP interface.
Connect a network patch cable to the “10/100-Base-T” connector on the
rear side of the device and your existing IP network.
The device can be fully operated with an internet browser via the
integrated web interface. Use a computer that is connected to the same
IP network that the Tiger E5 device is connected to. Start an internet
browser, Firefox/Mozilla >V2.0 Google Chrome both with Java Script
activated and enter the configured IP address in the address bar of the
browser. If the IP address has not been changed in step 2, please enter
the default address in the address bar of the browser:
192.168.XXX.XXX.
These first steps are only intended for a quick first start and do not
cover all device functions. Pease read carefully the entire manual to be
able to use all functions of the device.
Important note on the
Username and password
The equipment comes out from Axel Technology with a standard
username: admin and password: admin
Each time a NEW user, with administration rights is created, the user
admin disappear and it is replaced by the new one just created. If all
users are deleted, the standard admin – admin comes out again

DEVICE GENERAL DESCRIPTION |FRONT PANEL
TIGER E5 · User Manual · ENG
10. DEVICE GENERAL DESCRIPTION
FRONT PANEL
TIGER E5
•
Mechanical Steel, 1U - 19 " rack standard.
•
40 Led Alarms
•
USB Port - Type A.
REAR PANEL
TIGER E5
•
Universal Power Supply 90Vac - 240Vac 50/60Hz

DEVICE GENERAL DESCRIPTION |REAR PANEL
TIGER E5 · User Manual · ENG
•
2 BNC input connectors: AUX-1 and AUX-2.
•
2 BNC output connectors: OUT-1 and OUT-2
•
2 Analog mono input

DEVICE GENERAL DESCRIPTION |REAR PANEL
TIGER E5 · User Manual · ENG
•
1 Digital stereo input
•
USB port - Type A
•
SD Card Slot

DEVICE GENERAL DESCRIPTION |REAR PANEL
TIGER E5 · User Manual · ENG
•
LAN/WAN Ethernet port
•
GPIO Port with 6 optocouplers and 4 relay on DB 25.
•
2 serial ports RS232 on DB9 + DB25

FIRST DEVICE START |STARTING YOUR TIGER E5 - QUICK SETUP
TIGER E5 · User Manual · ENG
11. FIRST DEVICE START
After important setting changes we suggest you always to reboot the device (In example: after a device upgrade, or changes on IP address).
STARTING YOUR TIGER E5 - QUICK SETUP
Turn ON the TIGER E5 device with the power switch, on the rear panel:
Connect the device to your LAN with an ETHERNET CABLE. Your device could be controlled by one of the following methods (1 or 2).
1. The device could be controlled by a web page on your browser. In the address field of your browser, type the default IP address:
192.168.0.10. You will see the Home Page:
2. We provided you a little WIFI USB KEY. Connect it inside one of the USB ports of the device. If you have more than a WIFI USB KEY
connect once a time:
a. Search for the following WIFI connection with your mobile phone, tablet or WIFI pc: Config_AP
b. Connect to Config_Ap
c. The password is 12345678
d. The device could be controlled by a web page on one of your browsers. Open a browser inside your mobile phone, tablet or wifi
pc and in the address field type whatever URL you want.
N.B., do not type any https URLs.

FIRST DEVICE START |STARTING YOUR TIGER E5 - QUICK SETUP
TIGER E5 · User Manual · ENG
11.1.1 HOME PAGE
In the previous screen you can read for some parameters of your device. To see all parameters and to change them you have to login with an apposite Username and password.
Click LOGIN at top-right.
The equipment comes out from Axel Technology with a standard username – the default admin:
Username: admin (case sensitive)
password: admin (case sensitive)

FIRST DEVICE START |STARTING YOUR TIGER E5 - QUICK SETUP
TIGER E5 · User Manual · ENG
NB: Each time a NEW user, with administration rights is created, the user admin disappears and it is replaced by the new one just created. If all users are deleted, the default admin
comes out again, in order to create and enter the device settings
In the following mask click on Go to Quick Setup Menu:
At the first start the following mask will open automatically, click on Go to Quick Setup Menu:
To confirm click on Confirm

FIRST DEVICE START |LOGIN
TIGER E5 · User Manual · ENG
Go down in the page, read the instructions until the end of the page and fill all the parameters. You can set all the most important RDS Parameters You can set all the most important
RDS Parameters. In this way you can be immediately ONAIR with your RDS. We suggest you to change device Network Ip Address and to create the Users you need.
LOGIN
You will see the Login mask as shown in this picture:
In the first field type for your Username, and in the second one type for the Password. Than click on Login.
If you see the following message you typed a wrong Username or a wrong Password.
Type them again and retry

FIRST DEVICE START |LOGGED IN USER – HOME PAGE
TIGER E5 · User Manual · ENG
LOGGED IN USER – HOME PAGE
Once you are logged, you will see the home page as shown in the following picture. The left-tree menu could be different for different user classes:

FIRST DEVICE START |SUMMARY MASK
TIGER E5 · User Manual · ENG
SUMMARY MASK
At the top of the page you can see a fast summary mask with all the current parameters and warnings as shown in the following picture:
SYSTEM
Scheduler LED. The scheduler is ON
Extended RDS status LED. To
enable/disable this Led go to
RDS/RBDS>Basic Settings > Rds Settings>Rds
Global Extended Mode
The system is ok. The
change should be done in
Setup>SMTP>SMTP On
Here you can view Date
and Time
Enable/Disable a GPS device. To enable/disable
it go to Setup>GPS>General Settings>GPS On

FIRST DEVICE START |SUMMARY MASK
TIGER E5 · User Manual · ENG
Enable Disable a NTP Server. To enable/disable
it go to Setup>NTP>Ntp On
Enable/Disable the UTC(Coordinated
Universal Time). To enable/disable it enable
the NTP or enable the GPS and go to
SETUP>GPS>Get UTC from GPS.
RSS FEED Led Status. In this picture
example it is disabled.
SAMBA server Led Status
REST Api Led Status, to change it go
to SETUP>General Setup>REST
Settings>Active. In this picture example it is
disabled.
TCPIP: you can connect the device to a maximum of 4 TCP/IP devices.
The related led lights up when UECP packets are received.
SERIALS: you can connect the device to a maximum of 2 Serial devices.
The related led lights up when UECP packets are received.
UDP: you can connect the device to a maximum of 4 UDP devices. The
related led lights up when UECP packets are received.
SNMP: The led lights up when SNMP UECP packets are received.

FIRST DEVICE START |SUMMARY MASK
TIGER E5 · User Manual · ENG
GPO: You can connect the device to a maximum of 4 GPO devices(GPO1,
GPO2, GPO3, GPO4). These LEDs indicate status of the related GPO
device.
To set GPO settings go in Setup>GPIO>GPO(1/2/3/4) and in
Setup>GPO>GPO Event Notification. GPO1, GPO2, GPO3, GPO4.
GPI: you can connect a maximum of 6 GPI devices. These LEDs light up
when the related GPI device is turned on.
Here you can view the statistics connected with the system. CPU usage, Memory usage, and system
temperature.
RDS output signal intensity in mV(millivolt peak to peak). RDS/RDBS>Rds
Settings>Rds Levels
Phase
Synchronism between Rds signal and pilot frequency. Int: internal pilot managed by
the Tiger E5, RDS/RDBS>Rds Synchronism
Here you can view RDS group sequence.

FIRST DEVICE START |SUMMARY MASK
TIGER E5 · User Manual · ENG
PS (Program
Station) NAME
Here you can read the aired DATASET
number to change it go to RDS/RBDS>Active
Dataset Selection>On Air Active Dataset. PS,
PI, PTY-PTYN, DI depend on the selected
Dataset. To change them go to
RDS/RBDS>(UECP Main/UECP Eon)PS
DI (Decoder Information).
PTYN-PTY
PTY (Program Type) – PTYN (Program Type Name)
RADIOTEXT & RDS SERVICES
Here you can view the set RadioText and all the active services
RDS/GROUPS STATISTIC
Here you can view a rotation with the
statistics of the active groups.

FIRST DEVICE START |SUMMARY MASK
TIGER E5 · User Manual · ENG
To assign a label here go to MPX > Changeover > Source A > MPX
Mixer > Reference Label
To assign a label here go to MPX > Changeover > Source B > MPX
Mixer > Reference Label
Go to MPX > Changeover > Source A > MPX Source A Validation to turn
on the Validation Controls. Yellow is valid, red is invalid.
Go to MPX > Changeover > Source B > MPX Source B Validation to turn
on the Validation Controls. Yellow is valid, red is invalid.
From this Led Meters you can see the Source A levels and the Source B
levels
Go to MPX > Changeover > Delay / Mode to change the Changeover
section
Go to MPX > Outputs > MPX Output 1 > Source
Go to MPX > Outputs > MPX Output 2 > Source
Go to MPX > Internal MPX Encoder > Preemphasis
From this Led Meters you can see the MPX Output levels

FIRST DEVICE START |SUMMARY MASK
TIGER E5 · User Manual · ENG
Here you can see which parts of the MPX Signal you are sending. To
change this go in MPX > Outpits > MPX Output 1 > Source
Here you can set the Headphones level and the Source. To change
the Headphone Source click on the SRC button
Here you can have an overview on the 4 audio sources and levels of
the audio changeover. To change 1SRC an 2SRC go to Audio Input >
Changeover > Sources > Source 1 and to Audio Input > Changeover >
Sources > Source 2
Here you can have an overview on the 4 audio sources and levels of
the audio changeover. To change 3SRC an 4SRC go to Audio Input >
Changeover > Sources > Source 3 and to Audio Input > Changeover >
Sources > Source 4
Go to Audio Input > Changeover > Audio Changeover > Configuration
> Mode to select the Audio Changeover Mode. Go to Audio Input >
Changeover > Audio Changeover > Sources to select the Sources for
the Source1, Source2, Source3, Source4
Go to Audio Input > Changeover > Audio Changeover > Configuration
> Mode to select the Audio Changeover Mode. Go to Audio Input >

FIRST DEVICE START |SUMMARY MASK
TIGER E5 · User Manual · ENG
Changeover > Audio Changeover > Sources to select the Sources for
the Source1, Source2, Source3, Source4
Go to Audio Input > Sources > Output Monityor > Output Sources
Monitor > Configuration > Audio Monitor Sources
If you resize your browser press the button to open the following navigation menu:

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
SETUP
By clicking on setup you can see all the available setup subpages as shown in the following picture:
11.5.1 GENERAL SETUP
In Setup > General Setup you have different general parameters to start device setup:
Target References
Host Name Prefix: default field with the Product Name. This parameter is unchangable
Host Name Custom: customizable parameter. Type here the desired device name. This parameter helps you to recognize the device in
your computer network.
Host Name: Host Name Prefix(fixed value) + Host Name Custom
Target Name Ref.: Type here a desired name for the device
Target Location Ref.: Type here the device location
Target Operator Ref.: Type here the Operator name

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
Other Settings
Language: Select here the desired device language
Http Bandwidth: Select here between Gprs, Low, Normal or High bandwidth
Local Time Zone: Select from the dropdown menu the desired Time Zone
REST Settings
Active: Check/Uncheck this box if you want to activate/deactivate the REST API for the device
Port: Type the REST API port

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
SMB/SAMBA Share Settings
This folder helps you to air TITLE and SONGS datas via RDS directly from your playout software
Active: Check/Uncheck this parameter to activate/deactivate the control on the playout folder
Hostname IP / URL: Type here the IP/URL of the Playout PC
Smb/Samba Share: Type here the playout xml path
User Name: Type here the PC / Folder Username
Password: Type here the PC / Folder Password
Masked/Unmasked: decide here if you want to mask/unmask the Alarms related with the connectivity with the PC / Folder. If you see
SMB/SAMBA Alarms something is wrong wit the IP/URL, or USERNAME and PASSWORD

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
Target Localization
Manual Target Coordinates: Check/Uncheck this parameter to activate/deactivate the Manual Target Coordinates
insertion.
Latitude: Latitude insertion is activated when Manual Target Coordinates is checked. Type here the manual latitude
Longitude: Longitude insertion is activated when Manual Target Coordinates is checked. Type here the manual
longitude
Marker Baloon Field: Insert here what you want to read on the map Marker Baloon at the selected coordinates.
Manual Target Clock Synchronization
Synchronize Target with Client Clock: synchronizes the clock with the client pc clock

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
11.5.2 NETWORK
In Setup > Network>ethx you have different parameters to set configurations for the device network connection and addressing:
Mac Address
MacAddress: Here the Super Technician can type the device Mac Address.
In General Configuration you can read for all the current network settings.
IPv4 Addressing
IPv4 Addressing Method: choose here the Addressing Method. You can choose between Manual or DHCP(auto).
Manual: if you choose Manual you have to insert all IPv4 and DNS IPv4 datas.
DHCP(auto): a DHCP (Dynamic Host Configuration Protocol) server dynamically distributes network configuration
parameters.
IPv4 enable: check this parameter to enable/disable the IPv4 network addressing.
IPv6 Addressing

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
IPv6 Addressing Method: choose here the Addressing Method. You can choose between Manual or DHCP(auto).
Manual: if you choose Manual you have to insert all IPv6 and DNS IPv6 datas.
DHCP(auto): a DHCP (Dynamic Host Configuration Protocol) server dynamically distributes network
configuration parameters.
IPv6 enable: check this parameter to enable/disable the IPv4 network addressing.
In the following setting sections you can fill all the desired IP datas if you have set Manual Addressing Method:
Primary IPv4
Additional #1 IPv4
Additional #2 IPv4

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
Primary IPv6
Additional #1 IPv6
Additional #2 IPv6

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
DNS IPv4
Enable(Primary DNS IPv4): If it is needed, click on the checkbox to enable a Primary DNS IPv4
Primary DNS(IPv4): type here the IP of the desired DNS server
Enable(Additional #1 DNS IPv4): Check it to enable the first additional DNS IPv4 Server
Additional #1 DNS(IPv4): type the IP of the DNS server
Enable(Additional #2 DNS IPv4): Check it to enable the second additional DNS IPv4 Server
Additional #2 DNS(IPv4): type the IP of the DNS server.
DNS IPv6
Enable(Primary DNS IPv6): If it is needed, click on the checkbox to enable a Primary DNS IPv6
Primary DNS(IPv6): type here the IP of the desired DNS server
Enable(Additional #1 DNS IPv6): Check it to enable the first additional DNS IPv6 Server
Additional #1 DNS(IPv6): type the IP of the DNS server
Enable(Additional #2 DNS IPv6): Check it to enable the second additional DNS IPv6 Server
Additional #2 DNS(IPv6): type the IP of the DNS server.

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
CONFIGURATION
Send Network Configuration: By clicking on this button you send the new network configuration. To confirm the process you have to connect
to the new set IP and you have to press the following button.
Confirm Network Configuration: If you do not confirm the new configuration within 5 minutes, the last changes are not implemented. After
the pression of this button you will see the following message:
11.5.2.1 DEVICE TEMPORARY IP ASSIGNMENT
Inside the USB key create a new txt file - The file name has to be
exactly: NetworkTEMPConfig.txt

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
Edit NetworkTEMPConfig.txt and write
inside the temporary IP you want set for
your TIGER E5. The syntax has to be: IP/24
Insert the USB key in the USB Port of the
device front panel
Open your browser and insert the IP in the
url address. If you plug out the IP you loose
the temporary IP.
(in this example we have set the
192.168.0.14 IP, but you can decide freely)

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
11.5.3 NTP
In Setup > NTP you have all the settings related with the Network Time Protocol. Here you can synchronize the device with different desired
NTP Servers clock time to start with them the data packet exchange.
GENERAL SETTINGS
NTP ON: click on the checkbox to enable/disable the Sync with a desired NTP server
TYME SYNCH: decide the sync interval
SYNC RETRIES: decide the sync retries in case of failure
LOCAL TIME ZONE: select the Local Time Zone related with the geographical device position.
PRIMARY NTP SERVER
IP ADDRESS / URL: type the IP/URL of the desired primary NTP server to synchronize the device clock with the server clock.
NTP VERSION(AUTO, V1, V2, V3, V4): select the desired NTP version

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
ADDITIONAL #1 NTP SERVER
IP ADDRESS / URL: type the IP/URL of the first desired additional NTP server.
NTP VERSION(AUTO, V1, V2, V3, V4): select the desired NTP version
ADDITIONAL #2 NTP SERVER
IP ADDRESS / URL: type the IP/URL of the second desired additional NTP server.
NTP VERSION(AUTO, V1, V2, V3, V4): select the desired NTP version
The event section is useful to mask/unmask problems detection with the connection between the device and the NTP Servers.
NTP Events
Masked/Unmasked NTP Warning: the warning control records in logs section a connection problem with one or more DNS Servers. Select
Mask to enable the record or Unmask to disable it
Masked/Unmasked NTP Alarm: the Alarm control records in logs section a connection problem with all DNS Servers. Select Mask to enable the
record or Unmask to disable for it.

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
11.5.4 SNMP
In Setup > SNMP you can setup all parameters related with the Simple Network Management Protocol. Here you can define parameters for
different NMS (Network Management Server) for the network and trap management.
SNMP Settings
Snmp Agent Enabled: click on this checkbox to enable or disable the SNMP agent for the warning or alarm traps.
Read Community
Read Community: it is set on “public” by default. It is the Community String related to the SNMP requests from NMS to the device. If you want
to protect your datas change it here and in the NMS.
Write Community
Public/Private: it is set on “private” by default. It is the Community String related to the SNMP device settings from NMS to the device. To have
a better protection in the Write Community change the Community String here and in the NMS.
HEART SIGNAL TRAP
Heart Signal Trap: select between ON/OFF if you want to enable/disable the device Heartbeat signal trap.
Restart SNMP Interface
Restart SNMP Interface: This command restarts the SNMP interface

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
SNMP MIB
Download MIB File: Downloads the MIB file
NMS-1 SETTINGS
NMS-1 IP Address / Url: type the NMS-1 IP Address / Url for SNMP traps
NMS-1 Trap Port: type the NMS Trap port
NMS-1 Trap Community: choose between public/private
NMS-1 Trap Global Enable: choose between Enable/Disable
NMS-1 Trap Type: choose between trap SNMP V1/trap SNMP V2c/info SNMP V2
NMS-1 Trap Timeout: type here the seconds for the trap timeout
NMS-1 Trap Retry: type here the desired number of trap retries

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
NMS-2 SETTINGS
NMS-2 IP Address / Url: type the NMS-2 IP Address / Url for SNMP traps
NMS-2 Trap Port: type the NMS Trap port
NMS-2 Trap Community: choose between public/private
NMS-2 Trap Global Enable: choose between Enable/Disable
NMS-2 Trap Type: choose between trap SNMP V1/trap SNMP V2c/info SNMP V2
NMS-2 Trap Timeout: type here the seconds for the trap timeout
NMS-2 Trap Retry: type here the desired number of trap retries

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
NMS-3 SETTINGS
NMS-3 IP Address / Url: type the NMS-3 IP Address / Url for SNMP traps
NMS-3 Trap Port: type the NMS Trap port
NMS-3 Trap Community: choose between public/private
NMS-3 Trap Global Enable: choose between Enable/Disable
NMS-3 Trap Type: choose between trap SNMP V1/trap SNMP V2c/info SNMP V2
NMS-3 Trap Timeout: type here the seconds for the trap timeout
NMS-3 Trap Retry: type here the desired number of trap retries

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
NMS-4 SETTINGS
NMS-4 IP Address / Url: type the NMS-4 IP Address / Url for SNMP traps
NMS-4 Trap Port: type the NMS Trap port
NMS-4 Trap Community: choose between public/private
NMS-4 Trap Global Enable: choose between Enable/Disable
NMS-4 Trap Type: choose between trap SNMP V1/trap SNMP V2c/info SNMP V2
NMS-4 Trap Timeout: type here the seconds for the trap timeout
NMS-4 Trap Retry: type here the desired number of trap retries

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
SNMP Alarms
Masked/Unmasked SNMP Warning: decide here if you want to mask/unmask the warnings related with the connectivity between the
device and the NMS servers.
Masked/Unmasked SNMP Alarm: decide here if you want to mask/unmask the alarms related with the connectivity between the
device and the NMS servers.
Traps/Notifications
Masked/Unmasked SMTP Warning: Mask /Unmask the Warning trap or notifications related to the connection between the device and one or
more SMTP Servers
Masked/Unmasked SMTP Alarm: Mask /Unmask the Alarm trap or notifications related to the connection between the device and all set
SMTP Servers

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
Masked/Unmasked NTP Warning: Mask /Unmask the Warning trap or notifications related to the connection between the device and one or
more NTP Servers
Masked/Unmasked NTP Alarm: Mask /Unmask the Alarm trap or notifications related to the connection between the device and all set NTP
Servers
Masked/Unmasked GPI1 Event: Mask /Unmask the Event trap or notifications related to the detection of electrical GPI1 events
Masked/Unmasked GPI2 Event: Mask /Unmask the Event trap or notifications related to the detection of electrical GPI2 events
Masked/Unmasked GPI3 Event: Mask /Unmask the Event trap or notifications related to the detection of electrical GPI3 events
Masked/Unmasked GPI4 Event: Mask /Unmask the Event trap or notifications related to the detection of electrical GPI4 events
Masked/Unmasked GPI5 Event: Mask /Unmask the Event trap or notifications related to the detection of electrical GPI5 events
Masked/Unmasked GPI6 Event: Mask /Unmask the Event trap or notifications related to the detection of electrical GPI6 events
Masked/Unmasked GPS Alarm: Mask /Unmask the GPS Alarm trap or notifications related to the connection between the device and the
connected GPS device
Masked/Unmasked Pilot Sync Alarm: Mask /Unmask the Alarm trap or notifications related to the connection between the device and the
connected stereo encoder/digital pilot generator

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
11.5.5 SMTP
In Setup > SMTP you can setup all parameters related to the Simple Mail Transfer Protocol. Here you can define parameters for different SMTP
servers for the e-mail notification on the device functioning.
SMTP Settings
SMTP On: Click on the checkbox to activate/deactivate the SMTP service
Delivery Interval: Select the desired Delay Interval for the Email Notifications. If SMTP On is checked you will have Email
Notifications every Delivery
Interval.
Sender E-Mail Name: Type here a standard Sender E-mail Name
Sender Display Address: Type here the default Sender Display Address. Receivers will read this sender address
Sender E-Mail Subject: Email Receivers will read this E-Mail Subject.
SMTP Receivers
Receiver #1: type the 1
st
target email address (optional)
Receiver #2: type the 2
nd
target email address
Receiver #3: type the 3
rd
target email address
Receiver #4: type the 4
th
target email address

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
MAIN SMTP Server Settings
Description: type here a short description for the desired main SMTP Server
Server IP Address / Url: the IP Address / Url of your SMTP server domain
Port: TCP port for the communication
Security protocol: Network Security protocol
Authorization Method: choose the desired method from the list
Username: email username
Password: email password

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
Additional SMTP Server #1 Settings
Enable Server: check this box if you want to enable the first additional SMTP Server
Description: type here a short description for the desired SMTP Server
Server IP Address / Url: the IP Address / Url of your SMTP server domain
Port: TCP port for the communication
Security protocol: Network Security protocol
Authorization Method: choose the desired method from the list
Username: email username
Password: email password

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
Additional SMTP Server #2 Settings
Enable Server: check this box if you want to enable the second additional SMTP Server
Description: type here a short description for the desired SMTP Server
Server IP Addres / Url: the IP Address / url of your SMTP server domain
Port: TCP port for the communication
Security protocol: Network Security protocol
Authorization Method: choose the desired method from the list
Username: email username
Password: email password
SMTP Events
Masked/Unmasked SMTP Warning: the warning control logs a connection problem with one or more SMTP Servers. Select Masked to enable
the log or Unmasked to disable it
Masked/Unmasked NTP Alarm: the Alarm control logs a connection problem with all SMTP Servers. Select Masked to enable the log or
Unmasked to disable it.

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
11.5.6 GPIO
In Setup > GPIO you can setup all parameters related with the General Purpose Input/Output. Here you can define the behaviour of different
GPI or GPO devices.
GPI Logic
For every following 6 GPI devices you can choose between:
Positive Logic: the event is logged when the GPI circuit is closed.
Negative Logic: the event is logged when the GPI circuit is opened

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
GPI Events
Masked/Unmasked GPI1 Event: Select Masked to enable or Unmasked to disable the log of GPI1 events
Masked/Unmasked GPI2 Event: Select Masked to enable or Unmasked to disable the log of GPI2 events
Masked/Unmasked GPI3 Event: Select Masked to enable or Unmasked to disable the log of GPI3 events
Masked/Unmasked GPI4 Event: Select Masked to enable or Unmasked to disable the log of GPI4 events
Masked/Unmasked GPI5 Event: Select Masked to enable or Unmasked to disable the log of GPI5 events
Masked/Unmasked GPI6 Event: Select Masked to enable or Unmasked to disable the log of GPI6 events

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
GPO LOGIC
For every following 4 GPO devices you can choose between:
Positive Logic: the generated event is the closing of the GPO circuit
Negative Logic: negative logic: the generated event is the opening of the GPO circuit

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
In GPO Event Notifications you can decide to root to the GPO device: no Event Source(OFF), to root all Event Sources(ON), to root a selected
Event Source (in example: NTP Alarm).
in every GPO menu select the event source that you want to listen, as shown in the following picture:
Pilot Sync Alarm: alarm starting when the frequency of the encoded RDS/RBDS signal is out of sync with an available external pilot(analogue
MPX frequency / digital frequency by the SYNC/MPX inputs).

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
11.5.7 GPS
In Setup > GPS you can setup all parameters related to the Global Positioning System. Here you can define parameters for a desired GPS device
for the satellite geolocation.
General Settings
Gps On: Enable/Disable the GPS device
Gps Device: Name of the GPS device connected
GPS Lock Status: Lock/Unlock the GPS status
GPS Satellites in view: Satellites Number in view
GPS Latitude: Type here the Latitude coordinate. If GPS is turned on this value is automatically
inserted
GPS Longitude: Type here the Longitude coordinate. If GPS is turned on this value is
automatically inserted
GPS Date & Time Last Value: Type here the Date and Time. If Get UTC from GPS is enabled this
value is automatically inserted
GPS Events
Masked/Unmasked GPS Alarm: the alarm control logs a connection problem with the GPS device. Select Masked to enable the log or
Unmasked to disable it

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
11.5.8 SYSTEM TOOLS
11.5.8.1 UPDATES
FIRMWARE UPDATES
By pushing the button below you will search if there are FW update files available. If so, you can update the Firmware clicking on 'Upgrade' in
the window.
During this process you should not shutdown or reboot this device.
SYSTEM UPGRADES
By pushing the button below you will search if there are System upgrade files available.
Warning: If you upgrade System clicking on 'Upgrade' in the window this device will be rebooted.

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
11.5.8.2 DEVICE MANAGEMENT
REBOOT DEVICE
This button will cause a device reboot.
11.5.8.3 SD CARD UTILITIES
SD STATUS
SD Found
If an external SD is found, this status will be OK, otherwise to use the tools below you need to insert (or change) a SD card in the external back
slot.
SD Structure
The external SD card must be formatted and prepared with a particular folder tree. If this status is not OK, you need to format & prepare it
using the format button below.
FORMAT AND PREPARE
This procedure will format the external SD card and prepares it to receive data.

FIRST DEVICE START |SETUP
TIGER E5 · User Manual · ENG
CLONING TOOLS
This procedure will create a clone data structure on the external SD card.
This procedure will create a clone data structure from the external SD card.
Important: System will be offline for a few minutes.

FIRST DEVICE START |ADMINISTRATION
TIGER E5 · User Manual · ENG
ADMINISTRATION
In Administration section you can read, manage all the users and you can set their access permissions to the device. These section can be
managed only by the Admin users.
Users List
Selected user
Not selected user
Remove button
Confirm the selected user removal
Add a new User
User Details (user name)

FIRST DEVICE START |ADMINISTRATION
TIGER E5 · User Manual · ENG
Full Name: User Name
E-Mail: user email
User Class: user class, here you can decide user permissions.
Discard Changes from the selected user
Change the password for the selected user
Save Changes for the selected user

FIRST DEVICE START |ADMINISTRATION
TIGER E5 · User Manual · ENG
11.6.1 USER CLASS – USER RIGHTS TO LOGIN THE SYSTEM
Super Technician
Hided user, it could not be delated or edited. The Super Technician has access to all pages, including calibration. Useful when debugging and to
calibrate the machine.
Full Administrator
The Full Administrator manages all user profiles, accesses all pages (except the calibration).
Default Administrator (Default User): The default administrator is the default user of the device, it is under the Full Administrator
cathegory, but it has fixed access credentials (user: admin – pwd: admin). This user is visible only when the system has no other Full
Administrators.
User Administrator
User Administrator. It manages the profiles of all users.
Device Administrator
Non-administrator user that accesses all pages (it does not accesses to administration, calibration and some of the product nameplate data).
Technician
Technician is the one who controls all the hardware parameters of the machine and the control of information pages.
Broadcaster
It has full control only on information management pages and on the audio signal.
Guest/Reader
Guest accesses anywhere without being able to edit any parameter.

FIRST DEVICE START |ADMINISTRATION
TIGER E5 · User Manual · ENG
Below, a summary table with the list of product pages and access rights for each type of use:
Legend
RW: full access (read/write)
R: read only user
H: hided page
RW R RW R R R Administration
RW R RW R R R Serial Ports
RW R RW R RW R Uecp Main PS
RW R RW R RW R Uecp Main AF

FIRST DEVICE START |ADMINISTRATION
TIGER E5 · User Manual · ENG
RW R RW R RW R Uecp Eon AF
Audio Input
Sources: Analogic
Audio Input
Sources: Digital
Audio Input
Sources:
Multimedia
Audio Input
Sources: MPX
Decoder
Audio Input
Sources: Audio
Generator
Audio Input:Audio
Analysis

FIRST DEVICE START |ADMINISTRATION
TIGER E5 · User Manual · ENG
Multimedia
Stramer: Encoder
Multimedia
Stramer: Decoder
Calibration (and
MAC Address)

FIRST DEVICE START |ADMINISTRATION
TIGER E5 · User Manual · ENG
11.6.2 ADDING A NEW USER
To add a New User read the following steps:
1. Click on Add a New User button
2. Type in the following fields the new user details:
User Name: New User name
Full Name: New User full name
E-Mail: New User email address
User Class: Select here the new user class
Password: New User Password
Password(Confirm): Password confirmation
3. click on to discard last changes or click on to save for them.

TIGER E5 · User Manual · ENG
11.6.3 REMOVING AN EXISTING USER
To remove an Existing User read the following steps:
1. Move the mouse on the desired user
2. Click on button
3. In the following mask
Click on to exit from the user deletion or click on to confirm his deletion
LOGS
In Logs section you can read for all the device Log list.
You can see four Logs Section. For every section you can ,
you can Logs from the device beginning, or you can . All user classes can click some of these three
buttons.
Logs - User Permissions:
Administrator, super user, technician, broadcaster, default administrator - Logs Read&Write, Logs Debug Hided)
Super Technician(Logs Hided , Logs Debug Read&Write)
Guest (Logs Read&Write, Logs Debug Hided)

FIRST DEVICE START |CONFIGURATION
TIGER E5 · User Manual · ENG
11.7.1 DEBUG LOGS
In this section you can read for the connection errors logs with the previously set parameters in Setup section.
11.7.2 USERS LOGS
In this section you can read for the user logs changes or user logins or logouts.
11.7.3 EVENTS LOGS
In this section you can read for the logs of all detected events if they are unmasked in the related section.
11.7.4 NOTIFICATIONS LOGS
In this section you can read for the logs of sent notifications or alarms.
CONFIGURATION
Configuration
Import an existing .cnf file (json format) with all RDSE3 configs
Export a .cnf file (json format) with all RDSE3 configs in the desired folders

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
RDS/RBDS
In RDS/RBDS section you can set all the parameters from RadioText, to AF, from EON to PTY/PTYN. You can also set all Extended RDS/RBDS
parameters.
In this section you can setup all the shown parameters.
11.9.1 QUICK RDS SETUP
In this section it is possible to fill all the most important RDS/RBDS Parameters (In example PS, Radiotext..) All the parameters are explained in
light-blue info boxes.
ATTENTION: By pressing Start RDS Configuration you will reset the device to basic configurations. Do not press it if you do not want to loose some
settings
11.9.2 UECP PORTS
From this section you can set communication parameters with available remote devices. These devices must be able to send UECP packets
from their serial ports.

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
11.9.2.1 SERIAL PORTS
Serial 1 Port Configuration
Speed(UECP_7_05_100224 standard – Chapter: 3.1.59): No action, 75/…/115200 bps
Communication Mode (UECP_7_05_100224 standard – Chapters: 1.3.1 / 1.3.2 / 1.3.3): Unidirectional, Bidirectional Spontaneous, Bidirectional Requested
Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action, 1/2/3/../10 min, Inactive
Serial 2 Port Configuration
Speed(UECP_7_05_100224 standard – Chapter: 3.1.59): No action, 75/…/115200 bps
Communication Mode (UECP_7_05_100224 standard – Chapters: 1.3.1 / 1.3.2 / 1.3.3): Unidirectional, Bidirectional Spontaneous, Bidirectional Requested
Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action, 1/2/3/../10 min, Inactive

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
11.9.2.2 TCP/IP PORTS
From this section you can set communication parameters with available remote devices. These devices must be able to send UECP packets
through the TCP/IP protocol.
Tcp/Ip 1 Port Configuration
Mode: No Action, Low Priority, Normal Priority, High Priority
Communication Mode(UECP_7_05_100224 standard – Chapters: 1.3.1 / 1.3.2 / 1.3.3): Unidirectional, Bidirectional Spontaneous, Bidirectional Requested
Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action,1/2/.../254 min, Inactive
Tcp/Ip 2 Port Configuration
Mode: No Action, Low Priority, Normal Priority, High Priority
Communication Mode(UECP_7_05_100224 standard – Chapters: 1.3.1 / 1.3.2 / 1.3.3): Unidirectional, Bidirectional Spontaneous, Bidirectional Requested
Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action,1/2/.../254 min, Inactive

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
Tcp/Ip 3 Port Configuration
Mode: No Action, Low Priority, Normal Priority, High Priority
Communication Mode(UECP_7_05_100224 standard – Chapters: 1.3.1 / 1.3.2 / 1.3.3): Unidirectional, Bidirectional Spontaneous, Bidirectional Requested
Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action,1/2/.../254 min, Inactive
Tcp/Ip 4 Port Configuration
Mode: No Action, Low Priority, Normal Priority, High Priority
Communication Mode(UECP_7_05_100224 standard – Chapters: 1.3.1 / 1.3.2 / 1.3.3): Unidirectional, Bidirectional Spontaneous, Bidirectional Requested
Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action,1/2/.../254 min, Inactive

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
11.9.2.3 UDP & SNMP PORTS
From this section you can set communication parameters with available UDP remote devices. These devices must be able to send UECP packets
through UDP protocol.
UDP 1 Port Configuration
Mode: No Action, Low Priority, Normal Priority, High Priority
Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action,1/2/.../254 min, Inactive
UDP 2 Port Configuration
Mode: No Action, Low Priority, Normal Priority, High Priority
Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action,1/2/.../254 min, Inactive

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
UDP 3 Port Configuration
Mode: No Action, Low Priority, Normal Priority, High Priority
Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action,1/2/.../254 min, Inactive
UDP 4 Port Configuration
Mode: No Action, Low Priority, Normal Priority, High Priority
Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action,1/2/.../254 min, Inactive
The next setting section rules the communication with available devices. These devices must be able to send UECP packets in SNMP protocol.

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
SNMP Port Configuration
Mode: No Action, Low Priority, Normal Priority, High Priority
Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action,1/2/.../254 min, Inactive
11.9.3 BASIC SETTINGS

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
11.9.3.1 UECP ADDRESSING
The recipient encoder, getting UECP data frames from remote devices, must be identifiable by a unique address: Site (Zone) + Encoder ID. The
remote devices will send UECP data frames to recipients through this addressing data couple. In example a UECP data frame could be sent to all
RDS devices of a desired Site or to the same Encoder ID of all Sites.
This section is used to set the individual device UECP address. In Individual Address set RDS site number and encoder number.
Individual Address
Site(Zone): assign to your device a desired site number
Encoder: assign to your device a desired encoder ID number
Uecp Address
Here you can have all the Uecp Addresses list.
Site Addresses: the range of possible values is 1 to 1023
Encoder Addresses: the range of possible values is 1 to 63

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
11.9.3.2 RDS SETTINGS
Rds General Settings
Rds On: In the device Enable/Disable the RDS encoding
Rds Global Extended Mode: Enable/Disable the Extended Mode
Rds Synchronism (Pilot Synch): Internal, Auto Sync In (External & Digital), Auto Mpx In(External & Analogue)
PS Char Table Select: we suggest you to leave this parameter in No Control Chars
Active Dataset Selection
On Air Active Dataset: select the Dta Set number that you want to air.

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
Rds Levels
Current Level and Phase Reference Table Index: in the next field, enter the index number of the table row The related signal Level and
signal Phase couple will be aired
Level and Phase Reference Table: available, choosable and editable Levels(mVpp: millivolt peak-to-peak) and related Phases(Deg:
Degrees).
The following two parameter groups manage the special transitions of 15B group and 14B group in the standard RDS group sequence at the
TA/EON TA - ON/OFF.
TA Control (15B)
This control force the transition of the 15B group in the standard RDS group sequence in relation with the activation/deactivation of the TA.
Minimum Group Spacing: number of groups of the standard RDS sequence, between two recurrences of the 15B groups will be
inserted and transmitted.
ON Transition 15B(fast signal switching) Groups: only when TA is turned-ON, this parameter decides the number of 15B groups
transmitted in a single recurrence.
OFF Transition 15B Groups: only when TA is turned-OFF, this parameter decides the number of 15B groups transmitted in a single
recurrence

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
EON TA Control (14B)
This control force the transition of the 14B group in the standard RDS group sequence in relation with the activation/deactivation of the EON
TA.
Minimum Group Spacing: number of groups of the standard RDS sequence, between two recurrences of the 14B groups will be inserted
and transmitted.
ON Transition 14B(fast signal switching) Groups: only when EON TA is turned-ON, this parameter decides the number of 14B groups
transmitted in a single recurrence.
OFF Transition 14B Groups: only when EON TA is turned-OFF, this parameter decides the number of 14B groups transmitted in a single
Recurrence
File Name: in this field type the file name. The RDS will search in the previously set SMB/SAMBA IP/FOLDER for song and author informations.
Format: Choose between DjPro V.1.0, DjPro V.2.0, Dalet Simple, MB Studio.
Status: in this field you can see if the file is found or not

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
RDS Events
Masked/Unmasked Pilot Sync Alarm: Mask/Unmask the alarm of the synchronization between a Pilot frequency and the encoder.
Masked/Unmasked Smb/Samba Share Rds Alarm: Mask/Unmask the alarm of the connection with the communication folder with your
playout.
11.9.3.3 REAL TIME CLOCK
RTC Settings
CT On/Off: enable/disable the transmission of RDS Time clock.
Local Time Offset: Select here the desired Local Time Offset.
Real Time Clock Correction (ms): to avoid delays related to the signal transmission-reception, insert here a
clock correction time(ms).

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
11.9.4 STANDARD MODE
11.9.4.1 UECP SERVICES
Dataset General Settings
Editing Dataset Index: Select here the desired Index to start the related Dataset editing.
PSN List
Reference: in reference you can read all the available reference names
PS-Number: PS-Number of the related reference
ENABLED: (-E- : PSN enabled) (--- : PSN disabled)

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
PSN List Enable
is an example of Enabled EON. If the EON is enabled you can see in the bottom section. To disable it click on
the related
is an example of Disabled EON. To enable it click on it.
Group List
In the following mask you can decide the Group List and the group sequence order.
to add the group at the end of the group sequence
In the bottom section you see the list of group sequence
represents a present group inside the group sequence
By clicking on you move it in the previous sequence position
By clicking on you move it in the following order position
By clicking on you erase it from the sent RDS/RBDS groups.

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
By clicking on you can open the following top descripting table:
Group 1A Variant Sequence (SLC – Slow Labelling Codes)
In the following mask you can decide the Group 1A Variant Sequence and his Slow Labelling Codes sequence order.
to add the SLC at the end of the sequence
In the bottom section you see the list of SLC sequence
represents a present SLC inside the sequence
By clicking on you move it in the previous sequence position
By clicking on you move it in the following order position
By clicking on you erase it from the transmitted SLCs.

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
By clicking on you can open the following top descripting table:
Group 14A Variant Sequence (EON – Enhanced Other Networks information)
In the following mask you can decide the Group 14A Variant Sequence and his Codes sequence order.
to add the Code at the end of the sequence
In the bottom section you see the list of Codes sequence
represents a present code inside the sequence
By clicking on you move it in the previous sequence position
By clicking on you move it in the following order position
By clicking on you erase it from the transmitted codes list.

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
By clicking on you can open the following top descripting table:
11.9.4.2 UECP MAIN PS
This section is useful to define all UECP Main PS parameters
Main Network Program Service
Editing Dataset Index: decide which Main PS you want to edit, select the related DSN (Dataset
Number)
Editing Program Service: You will see this parameter also in UECP Eon PS. Here the parameters is
not selectable because this is the MAIN Program.

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
Basic Settings
PI(Program Identification): type the PI Code
PS(Program Station): type the Program Station Name
TP(Traffic Program): On/Off
TA(Traffic Announcement): On/Off
PTY: selectable value between: Pop Music, Rock Music, Culture, Science…
PTYN: type a desired description for the program
PIN Day: if you want to schedule a special PTY insert here the month day. From 00 to 31.
PIN Hour: If you want to schedule a special PTY insert here the desired hour (HH). From 00 to
23.
PIN Minute: If you want to schedule a special PTY insert here the desired minute (MM). From
00 to 59.
Music/Speech: select here if you have Music program or a Speech program
Decoder Information: select the audio decoder information

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
Linkage
Linkage information provides the means by which several programme services, each characterised by its own PI code, may be treated by a
receiver as a single service during times a common programme is carried. During such times each programme service retains its unique
identity, i.e. the programme service must keep its designated PI code and its AF (Alternative Frequency) list(s), but may change programme
related features such as PS, PTY, RT, TP and TA to reflect the common programme;
Linkage information is conveyed in the following four data elements:
LA(linkage actuator)
EG(extended generic index)
ILS (international linkage standard)
LSN (linkage set number)
Slow Labelling Codes
The RDS specification contains some additional slow labelling codes that are used to support various features. These are specified to be carried
in the type 1A group. In this section you can set SLC values.
SLC 0 (ECC)
SLC 1 (TMC)
SLC 2 (Paging)
SLC 3 (Language)
SLC 4 (not assigned)
SLC 5 (not assigned)
SLC 6 (Broadcaster use)
SLC 7 (EWS)

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
RBDS PI CALCULATOR (only if you are working on US soil)
CALL Letters: write the desired CALL Letters in this field, then click Convert. You will read the converted hexadecimal value in PI Code (Ex)
PI Code (Hex): write the desired hexadecimal PI Code in this field. Then click Convert. You will read the converted value in CALL Letters.
11.9.4.3 UECP MAIN AF
Main Network Editing Controls
Editing Dataset Index: decide which Main AF List (alternative frequencies) you want to edit, select the related DSN (Dataset Number)
Editing Program Service: You will see this parameter also in UECP Eon AF. Here the parameter is not selectable because this is AF of the
MAIN Program Service.

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
Alternative Frequencies
In the following list you can read AF (alternative frequencies) list of desired Tuned frequencies.
You see the list of Tuned frequencies with their own AF list. Black AF are universal. Blue AF are regional. click on to add a new row with AF
list or click on an existing row to edit it. The following mask will be enabled:
Method: decide between A/B. The B method allows you to specify also the regionality of the AF
Tuned Freq: here the Main Tuned Freq.
AF List: in this list you see different alternative frequencies separated by a comma (,) and a space. If you want to
specify that 90.2
frequency is regional. Type 90.2r.
Add: click on add to confirm parameters and to add them in rows.
Remove: click on a row that you want to delete and click on remove
Update: select a row that you want to edit, change parameters and click Update to save changes.

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
11.9.4.4 UECP RADIOTEXT
Main Network Editing Controls
Editing Dataset Index: decide which RadioText you want to edit, select the related DSN (Dataset Number)
Editing Program Service: Here the Program Service is not selectable because this is AF of the MAIN Program.
Radiotext
Reps: number of radiotext message repetitions
A/B Flag: The A/B flag is an important part of proper radiotext transmission. This flag is used to signal the receiver when a new text message is
transmitted. When the receiver detects a change in the A/B flag state, the radiotext receiver buffer will be cleared, preventing the possibility of
a mixture of old and new text messages being displayed on the receiver. In conclusion, the A/B flag should be enabled when multiple RT
messages are scheduled, while it can be disabled in the event of a fixed RT broadcasting.
RadioText: RadioText message
Add: after the new message creation click on send to start the RadioText transmission.
Remove: deletes the selected RadioText message
Update: , by selecting an existing RadioText row you can change it. To save new settings click on this button.

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
11.9.4.5 UECP EON PS
EON Program Service
Editing Dataset Index: decide which Eon PS(Program Service) you want to edit, select the related DSN (Dataset Number)
Editing Program Service: You will see this parameters also in UECP Eon AF. you can select between 10 different EON
Program Services.
EON Basic Settings
PI(Program Identification): type the PI Code
PS(Program Station): type the Program Station Name
TP(Traffic Program): On/Off
TA(Traffic Announcement): On/Off
PTY: selectable value between: Pop Music, Rock Music, Culture, Science…
PTYN: type a desired description for the program
PIN Day: if you want to schedule a special PTY insert here the month day. From 01 to 31.
PIN Hour: If you want to schedule a special PTY insert here the desired hour (HH). Possible. From 00 to
23.
PIN Minute: If you want to schedule a special PTY insert here the desired minute (MM). From 00 to 59.
Music/Speech: select here if you have Music program or a Speech program
Decoder Information: select the audio decoder information

FIRST DEVICE START |RDS/RBDS
TIGER E5 · User Manual · ENG
Eon Linkage
Linkage information provides the means by which several programme services, each characterised by its own PI code, may be treated by a
receiver as a single service during times a common programme is carried. During such times each programme service retains its unique
identity, i.e. the programme service must keep its designated PI code and its AF (Alternative Frequency) list(s), but may change programme
related features such as PS, PTY, RT, TP and TA to reflect the common programme;
Linkage information is conveyed in the following four data elements:
LA(linkage actuator)
EG(extended generic index)
ILS (international linkage standard)
LSN (linkage set number)
11.9.4.6 UECP EON AF
Eon Editing Controls
Editing Dataset Index: decide which EON AF (alternative frequencies) you want to edit, select the related DSN (Dataset
Number)
Editing Program Service: You will see this parameter also in UECP Main AF, you can select between 10 different EON
Program Services.