The AXEL AX3000 Terminal is based on a modular concept.
The AX3000 is designed and manufactured by Axel. The terminal's
electronics is contained within a slim base unit which provides connections
for a VGA or SVGA monitor, keyboard, system printer and Ethernet
network.
Notices
1 - NOTICES
1.1 - SAFETY NOTICES
Do not attempt to fix an AX3000 component failure by opening the terminal
case. In case of hardware failure, contact your service representative.
Check AC voltage from the wall outlet is compatible with the AX3000 external
power.
The power socket must be within easy reach and as near as possible to the
AX3000 Terminal.
Make sure all devices are powered off before connecting or disconnecting.
In order to ensure compliance with European EMC regulations (EN 55022),
shielded cables must be used when interfacing with other devices.
Refer to the respective supplier’s installation manual for instructions on
connecting the keyboard and monitor.
1.2 - EMC NOTICES
In order to ensure compliance with European EMC regulations (EN 55022)
and FCC Part 15 rules, it is required that shielded cables be used when
interfacing with other devices (peripherals or computers).
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
Installation Guide - Models 70
1
Notices
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help
1.3 - PHYSICAL SPECIFICATIONS
Operating temperature: 5 to 35 °C
Humidity: 80° non condensing
External power supply: 5V, 2A
Dimensions: 105x140x31 mm
Weight: 330 g
.
2 Installation Guide - Models 70
Installation
2 - INSTALLATION
This chapter provides information and instructions to install the Axel Terminal.
The terminal had been designed to be mounted on the flat screen: this requires
the monitor to have available the 4 VESA mounting screw holes.
a) Attaching the VESA Support
With the 4 screws provided
the monitor
attach the bracket to the VESA mounting points on
4
Installation Guide - Models 70
Installation
b) Hooking the Terminal
Hook the terminal to the bracket, matching the hooks with the corresponding
holes:
Installation Guide - Models 70
5
Installation
c) Using the Terminal
The terminal is now ready to be used. The cables can be connected on the read
panel (at the bottom). And the power switch is on the front panel (on the top).
Power switch
Cables
2.2.2 - Connecting Cables
For safety reasons and to prevent component damage do not apply power to
the AX3000 before connecting or disconnecting any cables. Do not plug in the
AX3000 power cord until all other connectors have been plugged in.
Make sure the AX3000 and monitor power switches are in the OFF (0) position
before connecting cables to the back panel.
6
Installation Guide - Models 70
Installation
a) The Monitor
Plug in the VGA monitor cable to the 'SVGA' connector on the terminal rear
panel.
Note: when the terminal is installed in a cabinet or rack, it is essential to
maintain air circulation around both the terminal and the VGA/SVGA monitor.
b) The Keyboard
Two keyboard types can be connected:
USB keyboard: connect it to on of the two USB ports on the terminal front
panel.
- PC/AT keyboard: connect it to the 'KEYB' connector on the terminal rear
panel. If your keyboard is fitted with a DIN connector, connect it using a
DIN-to-Mini-DIN adaptor.
c) The Mouse
Two mouse types can be connected:
USB mouse: connect it to on of the two USB ports on the terminal front
panel.
- PS/2 mouse: connect it to the connector with the mouse logo on the
terminal rear panel.
d) The Network
Plug the network cable into the socket labeled 'NET' on the terminal rear panel.
Note: the terminal network operating mode is indicated by two LEDs located on
each side of the terminal network socket:
The green LED on the left: It lights to indicate a satisfactory connection to
the Ethernet circuit (server or hub). If the LED does not light, check that
the Ethernet connector and cable both comply with the specifications
listed in chapter 4.1.
- The orange LED on the right indicates the actual network speed: 10Mb
when the light is off and 100 Mb when the light is on.
Installation Guide - Models 70
7
Installation
e) Other USB Devices
AX3000 Model 70 has two USB ports as a standard feature. These ports are
located on the front panel of the terminal case.
The USB cables must be shielded and cable length must not exceed 5 meters.
For more information (specifications, electric consumption...), see Chapter 4.
f) External Power Supply
The power is provided by the external power supply given with the Axel
terminal.
IMPORTANT: Only
use the Axel external power supply provided with your
AX3000 Model 70. Use of any other external power supply may cause
permanent damage to the AX3000.
Plug the cord connector of the external power supply to the AX3000 power
connector. Then plug the external power supply into the AC wall outlet.
2.2.5 - Power On
The power switch is located on the terminal front panel.
The green LED on the front of the terminal should light, and a single audible
beep should be heard, to indicate that the AX3000 terminal is powered up and
operating correctly.
To indicate correct keyboard initialization after power-up, the keyboard indicator
lights 'Num lock', 'Caps lock' and 'Scroll lock' should flash twice.
The green LED on the right side of the RJ45 connector on the back panel
remains lit, to indicate a satisfactory Ethernet connection.
If the terminal does not function as described above (for example if it emits a
continuous tone sound, or two beeps, or if an error message is displayed on the
screen) refer to chapter 5. If the terminal still does not operate properly, call
your service representative.
8 Installation Guide - Models 70
Initial Power-On
3 - INITIAL POWER-ON
This chapter describes the initial power-on procedure for the M70 terminal.
When the terminal is switched on up for the very first time two configuration
methods are available:
- Quick Set-Up: a wizard allows the terminal to be set-up in few seconds
for typical use.
- Auto-Configuration: used in conjunction with AxRM, this function allows
the terminal to automatically receive new firmware and/or a configuration
At any time pressing <Ctrl><Alt><Esc> will enter Terminal Set-Up.
For more information about set-up, please read the AX3000 User's Manual.
2.1 - QUICK SET-UP
The quick set-up is designed for a typical simple environment of:
- One server
- An optional router
- All sessions set identically
- An optional printer.
☺: This typical configuration may be modified at the end of the Quick Set-Up
procedure.
The ‘quick set-up’ guides the user through a setup menu in an intuitive manner.
Installation Guide - Models 70
9
Initial Power-On
(
The dialog box structure (referred to as a Wizard) is shown below:
First Screen
Serial Connection
RS232 session)
Graphical
display &
printer
(TSE, VNC
or Citrix with
local server
(published
application
or server )
Network Connection
(TCP/IP session)
Reboot
Citrix
Summarize
Citrix Desktop
Printer
(text 5250 or
3270
sessions)
Note: Depending on the Model 70 type, some screens are not available.
After exiting the set-up the terminal is automatically restarted and
ready to be
used.
2.2 - AUTO-CONFIGURATION
The Auto-Configuration feature allows a brand new ‘out of the box’ terminal to
be sent a specific firmware and/or configuration file without any human
10
Installation Guide - Models 70
Initial Power-On
intervention. There are also options to specify various terminal specific
parameters, for example an IP address and terminal name etc.
Note: the auto-configuration mechanism requires minimum version 2.0.2 of
AxRM (available free from www.axel.com
).
For more information on AxRM’s action in the auto-configuration process, see
the manual "Axel Remote Management - Version 3".
The auto-configuration process is automatically initiated when power is applied
to a brand new terminal or if the terminal is reset to factory defaults. This
process may be aborted by pressing any key.
Note: the auto-configuration may also be started at each terminal boot time.
The stages are:
- Checking the network (link),
- DHCP request sent to obtain an IP address and other parameters
(optional),
- Terminal contacts the AxRM server,
- Firmware file sent (if required), followed by a reboot,
- Configuration file sent, followed by a reboot.
Installation Guide - Models 70 11
Connector Pin Assignments
4 - CONNECTOR PIN ASSIGNMENTS
This chapter describes the connector pin assignments for the different ports of
the AX3000 Models 70.
4.1 - ETHERNET PORT RJ45 (NET)
Recommended wiring is a non-shielded twisted-pair cable (UTP), category 3
or 5
1 2 3 4 5 6 7 8
RJ45 connector
(Models 70 rear panel)
Note: the maximum length of a 10/100BaseT cable is 100 meters (330 feet).
The AX3000 keyboard interface is a Mini-DIN connector. To connect a
keyboard which has a DIN connector, use a DIN-to-Mini-DIN adaptor:
Pin Signal name
1 Data
2 --3 Ground
4 + 5 V DC
5 Clock
6 ---
56
34
12
Keyboard connector
(Models 70 rear panel)
4.3 - MOUSE INTERFACE
The AX3000 mouse interface is a Mini-DIN connector:
Pin Signal name
1 Data
2 --3 Ground
4 + 5 V DC
5 Clock
6 ---
56
34
12
Mouse connector
(Models 70 rear panel)
Installation Guide - Models 70
13
Connector Pin Assignments
4.4 - VIDEO INTERFACE
The AX3000 video interface is VGA and SVGA compatible:
54321
109876
1514131211
VGA/SVGA connector
(Models 70 rear panel)
Pin Signal name
1 Red
2 Green
3 Blue
4 Not Connected
5 Ground
6 Ground
7 Ground
8 Ground
9 Not Connected
10 Ground
11 Not Connected
12 CRT SDA
13 Horizontal sync.
14 Vertical sync.
15 CRT SCL
14
Installation Guide - Models 70
Connector Pin Assignments
4.5 - USB PORTS
AX3000 Models 70 are equipped with two USB ports located on the terminal
front panel.
Technical specifications:
- Supported speeds:
- Low-speed (1,5 Mbits): keyboard and mouse
- Full-speed (12 Mbits): printers
- Maximal consumption: 500 mA (for the both USB ports)
Note: Due to potentially excessive power consumption "non-IT" devices (such
as fans, lamps, etc) are strictly prohibited
Installation Guide - Models 70 15
Problem Solving
5 - PROBLEM SOLVING
This chapter describes some of the problems that may occur during installation
of the AX3000 Models 70, and offers possible solutions.
Safety Warning! Under no circumstances should you attempt
to fix a Platine problem by opening the terminal case. High
voltages may be present even when the terminal is switched
off. Only qualified technicians should open the AX3000 case.
- GREEN FRONT INDICATOR DOESN'T LIGHT, OR NO BEEP WHEN
YOU PRESS POWER SWITCH
Check there is power at the wall outlet and power cord connections.
- CONTINUOUS TONE SOUNDS AFTER THE TERMINAL HAS BEEN
SWITCHED ON
This alarm indicates a hardware failure. Report the problem to your service
representative.
- AFTER THE TERMINAL HAS BEEN SWITCHED ON, THE MESSAGES
'NO ETHERNET BOARD PRESENT' AND 'CANNOT ATTACH
ETHERNET BOARD' APPEAR
This message indicates a hardware failure. Report the problem to your service
representative.
- A DOUBLE-BEEP SOUNDS
After switching on the terminal, a double beep may sound, a few seconds after
the normal first beep.
16
Installation Guide - Models 70
Problem Solving
This signal indicates that keyboard initialization has failed. Check the keyboard
connection to the terminal back panel.
It is possible for the keyboard to function correctly, despite this double-beep
signal. As a quick test of keyboard operation, enter set-up mode by pressing the
<Ctrl><Alt><Esc> keys simultaneously. If set-up mode is working, you can
ignore the double beep signal and use the terminal normally.
- ETHERNET CONNECTION GREEN INDICATOR DOES NOT LIGHT
This indicator is the green LED located on the left side of the network connector
on the terminal back panel.
Failure to light when the terminal is switched on may be due to any of the
following:
- The Ethernet cable is disconnected at the far end,
- The device (host or hub), to which the network cable is connected, is not
switched on,
- There is a fault on the Ethernet cable or the cable is wired with incorrect
pin assignments.
- THE CONNECTED PRINTER DOES NOT WORK
First check that the cable pin assignment is correct.
Test the printer in local mode by selecting the [ASCII TEST] button within the
auxiliary port dialog box. (If ASCII format is not supported by the printer, the
banner won't be displayed.)