103 Freedom Drive • P.O. Box 525 • Lawrence, PA 15055-0525 USA
Phone: 1-724-873-8100 • Fax: 1-724-873-8105
www.axcera.com• info@axcera.com
RESTRICTIONS ON USE, DUPLICATION OR DISCLOSURE
This document contains information proprietary to Axcera, to its affiliates or to a third party to which Axcera
may have a legal obligation to protect such information from unauthorized disclosure, use or duplication. Any
disclosure, use or duplication of this document or any of the information herein for other than the specific
purpose for which it was disclosed by Axcera is expressly prohibited, except as Axcera may otherwise agree in
writing. Recipient by accepting this document agrees to the above stated conditional use of this document and
this information disclosed herein.
APPENDIX A .........................................................................................................1
Innovator CU3400BT/CU3T Analog Transmitter
Drawing List .........................................................................................................1
Instruction Manual, Rev. 0 ii 3/28/11
Innovator CU10BT-CU5000BT Analog Transmitter Introduction
Introduction
Manual Overview
This manual contains the description of the Innovator CU10BT-CU5000BT ATSC
Transmitter and the circuit descriptions of the boards, which make up the system. The
manual also describes the installation, setup and alignment procedures for the system.
Appendix A of this manual contains the system level drawings for the Innovator
CU10BT-CU5000BT NTSC Transmitter. Information and any drawings on OEM supplied
equipment are contained in the manufacturers supplied Instruction Manual.
Assembly Designation Numbers
Axcera has assigned assembly numbers, Ax designations, where x=1, 2, 3 etc., example
A1, to all assemblies, modules, and boards in the system. These designations are
referenced in the text of this manual and shown on the block diagrams and interconnect
drawings provided in the appendices. The Block Diagrams, Interconnects, Schematics,
Assembly Drawings and Parts Lists are arranged in increasing numerical order in the
appendices. Section titles in the text for assembly or module descriptions or alignment
procedures contain the associated part number(s) and the relevant appendix that contains
the drawings for that item.
The cables that connect between the boards within a drawer or assembly and that
connect between the drawers, racks and cabinets are labeled using markers. Figure 1-1
is an example of a marked cable. There may be as few as two or as many as four
Markers on any one cable. These markers are read starting farthest from the connector.
If there are four Markers, the marker farthest from the connector is the system number
such as system 1 or translator 2. The next or the farthest Marker is the rack or cabinet
“A” number on an interconnect cable or the board “A” number when the cable is within a
drawer. The next number on an interconnect cable is the Drawer location or Board “A”
number. The marker closest to the connector is the jack or connector “J” number on an
interconnect cable or the jack or connector “J” number on the board when the cable is
within a drawer.
Safety
The Innovator CU10BT-CU5000BT NTSC Transmitter systems manufactured by Axcera
are designed to be easy to use and repair while providing protection from electrical and
mechanical hazards. Please review the following warnings and familiarize yourself with
the operation and servicing procedures before working on the system.
Hazardous Accessibility – Axcera has made attempts to provide appropriate
connectors, wiring and shields to minimize hazardous accessibility.
Circuit Breakers and Wiring – All circuit breakers and wire are CE rated and are rated
for maximum operating conditions.
Technical Manual, Rev. 0 1
4
321
Figure 1-1: Marker Identification
Innovator CU10BT-CU5000BT Analog Transmitter Introduction
Single Point Breaker or Disconnect - The customer should provide a single point
breaker or disconnect at the breaker box for the main AC input connection to the
transmitter.
Transmitter Ratings - The transmitter ratings are provided in the text of this manual
along with voltage and current values for the equipment.
Protective Earthing Terminal – A main protective earthing terminal is provided for
equipment required to have protective earthing.
Read All safety Instructions – All of the safety instructions should be read and
understood before operating this equipment.
Retain Manuals – The manuals for the system should be retained at the system site for
future reference. Axcera provides two manuals for this purpose; one manual can be left
at the office while the other can be kept at the site.
Heed all Notes, Warnings, and Cautions – All of the notes, warnings, and cautions
listed in this safety section and throughout the manual must be followed.
Follow Operating Instructions – All of the operating and use instructions for the
system should be followed.
Cleaning – Unplug or otherwise disconnect all power from the equipment before cleaning.
Do not use liquid or aerosol cleaners. Use only a damp cloth for cleaning.
Ventilation – Openings in the cabinet and module front panels are provided for
ventilation. To ensure the reliable operation of the system, and to protect the unit from
overheating, these openings must not be blocked.
Servicing – Do not attempt to service this product yourself until becoming familiar with
the equipment. If in doubt, refer all servicing questions to qualified Axcera service
personnel.
Replacement Parts – When replacement parts are used, be sure that the parts have the
same functional and performance characteristics as the original part. Unauthorized
substitutions may result in fire, electric shock, or other hazards. Please contact the
Axcera Technical Service Department if you have any questions regarding service or
replacement parts.
Contact Information
The Axcera Field Service Department can be contacted by PHONE at 1-724-873-8100 or
by FAX at 1-724-873-8105.
Before calling Axcera, please be prepared to supply the Axcera technician with answers to
the following questions. This will save time and help ensure the most direct resolution to
the problem.
1. What are your Name and the Call Letters for the station?
2. What are the model number and type of system?
3. Is the system digital or analog?
4. How long has the system been on the air? (Approximately when was the system
installed?)
Technical Manual, Rev. 0 2
Innovator CU10BT-CU5000BT Analog Transmitter Introduction
5. What are the symptoms being exhibited by the system? Include the current front
panel LCD readings and what the status LED is indicating on the front panel of
the Drawer. If possible, include the LCD readings before the problem occurred.
Return Material Procedure
To insure the efficient handling of equipment or components that have been returned for
repair, Axcera requests that each returned item be accompanied by a Return Material
Authorization Number (RMA#). The RMA# can be obtained from any Axcera Field
Service Engineer by contacting the Axcera Field Service Department at 1-724-873-8100
or by Fax at 1-724-873-8105. This procedure applies to all items sent to the Field
Service Department regardless of whether the item was originally manufactured by
Axcera.
When equipment is sent to the field on loan, the RMA# is included with the unit. The RMA#
is intended to be used when the unit is returned to Axcera. In addition, all shipping
material should be retained for the return of the unit to Axcera.
Replacement assemblies are also sent with the RMA# to allow for the proper routing of the
exchanged hardware. Failure to close out this type of RMA# will normally result in the
customer being invoiced for the value of the loaner item or the exchanged assembly.
When shipping an item to Axcera, please include the RMA# on the packing list and on the
shipping container. The packing slip should also include contact information and a brief
description of why the unit is being returned.
Please forward all RMA items to:
AXCERA, LLC
103 Freedom Drive
P.O. Box 525
Lawrence, PA 15055-0525 USA
For more information concerning this procedure, call the Axcera Field Service Department
at 1-724-873-8100.
Axcera can also be contacted through e-mail at info@axcera.com and on the Web at
www.axcera.com.
Limited One Year Warranty for Axcera Products
Axcera warrants each new product that it has manufactured and sold against defects in
material and workmanship under normal use and service for a period of one (1) year
from the date of shipment from Axcera's plant, when operated in accordance with
Axcera's operating instructions. This warranty shall not apply to tubes, fuses, batteries,
bulbs or LEDs.
Warranties are valid only when and if (a) Axcera receives prompt written notice of
breach within the period of warranty, (b) the defective product is properly packed and
returned by the buyer (transportation and insurance prepaid), and (c) Axcera
determines, in its sole judgment, that the product is defective and not subject to any
misuse, neglect, improper installation, negligence, accident, or (unless authorized in
writing by Axcera) repair or alteration. Axcera's exclusive liability for any personal
and/or property damage (including direct, consequential, or incidental) caused by the
breach of any or all warranties, shall be limited to the following: (a) repairing or
Technical Manual, Rev. 0 3
Innovator CU10BT-CU5000BT Analog Transmitter Introduction
replacing (in Axcera's sole discretion) any defective parts free of charge (F.O.B. Axcera’s
plant) and/or (b) crediting (in Axcera's sole discretion) all or a portion of the purchase
price to the buyer.
Equipment furnished by Axcera, but not bearing its trade name, shall bear no warranties
other than the special hours-of-use or other warranties extended by or enforceable
against the manufacturer at the time of delivery to the buyer.
NO WARRANTIES, WHETHER STATUTORY, EXPRESSED, OR IMPLIED, AND NO
WARRANTIES OF MERCHANTABILITY, FITNESS FOR ANY PARTICULAR
PURPOSE, OR FREEDOM FROM INFRINGEMENT, OR THE LIKE, OTHER THAN AS
SPECIFIED IN PATENT LIABILITY ARTICLES, AND IN THIS ARTICLE, SHALL
APPLY TO THE EQUIPMENT FURNISHED HEREUNDER.
Technical Manual, Rev. 0 4
Innovator CU10BT-CU5000BT Analog Transmitter Introduction
HIGH VOLTAGE
DO NOT ATTEMPT TO REPAIR OR TROUBLESHOOT THIS EQUIPMENT UNLESS
YOU ARE FAMILIAR WITH ITS OPERATION AND EXPERIENCED IN
SERVICING HIGH VOLTAGE EQUIPMENT. LETHAL VOLTAGES ARE PRESENT
WHEN POWER IS APPLIED TO THIS SYSTEM. IF POSSIBLE, TURN OFF
POWER BEFORE MAKING ADJUSTMENTS TO THE SYSTEM.
RADIO FREQUENCY RADIATION HAZARD
MICROWAVE, RF AMPLIFIERS AND TUBES GENERATE HAZARDOUS RF
RADIATION THAT CAN CAUSE SEVERE INJURY INCLUDING CATARACTS,
WHICH CAN RESULT IN BLINDNESS. SOME CARDIAC PACEMAKERS MAY BE
AFFECTED BY THE RF ENERGY EMITTED BY RF AND MICROWAVE
AMPLIFIERS. NEVER OPERATE THE TRANSMITTER SYSTEM WITHOUT A
PROPERLY MATCHED RF ENERGY ABSORBING LOAD OR THE ANTENNA
ATTACHED. KEEP PERSONNEL AWAY FROM OPEN WAVEGUIDES AND
ANTENNAS. NEVER LOOK INTO AN OPEN WAVEGUIDE OR ANTENNA.
MONITOR ALL PARTS OF THE RF SYSTEM FOR RADIATION LEAKAGE AT
REGULAR INTERVALS.
WARNING!!!
Technical Manual, Rev. 0 5
Innovator CU10BT-CU5000BT Analog Transmitter Introduction
EMERGENCY FIRST AID INSTRUCTIONS
Personnel engaged in the installation, operation, or maintenance of this equipment are
urged to become familiar with the following rules both in theory and practice. It is the
duty of all operating personnel to be prepared to give adequate Emergency First Aid and
thereby prevent avoidable loss of life.
RESCUE BREATHING
1. Find out if the person is
breathing.
You must find out if the
person has stopped breathing.
If you think he is not
breathing, place him flat on
his back. Put your ear close to
his mouth and look at his
chest. If he is breathing you
can feel the air on your
cheek. You can see his chest
move up and down. If you do
not feel the air or see the
chest move, he is not
breathing.
2. If he is not breathing,
open the airway by tilting his
head backwards.
Lift up his neck with one
hand and push down on his
forehead with the other. This
opens the airway. Sometimes
doing this will let the person
breathe again by himself.
3. If he is still not breathing,
begin rescue breathing.
-Keep his head tilted
backward. Pinch nose shut.
-Put your mouth tightly over
his mouth.
-Blow into his mouth once
every five seconds
-DO NOT STOP rescue
breathing until help arrives.
LOOSEN CLOTHING - KEEP
WARM
Do this when the victim is
breathing by himself or help
is available. Keep him as
quiet as possible and from
becoming chilled. Otherwise
treat him for shock.
BURNS
SKIN REDDENED: Apply ice cold water to
burned area to prevent burn from going
deeper into skin tissue. Cover area with a
clean sheet or cloth to keep away air. Consult
a physician.
SKIN BLISTERED OR FLESH CHARRED:
Apply ice cold water to burned area to
prevent burn from going deeper into skin
tissue.
Cover area with clean sheet or cloth to keep
away air. Treat victim for shock and take to
hospital.
EXTENSIVE BURN - SKIN BROKEN: Cover
area with clean sheet or cloth to keep away
air. Treat victim for shock and take to
hospital.
Technical Manual, Rev. 0 6
Innovator CU10BT-CU5000BT Analog Transmitter Introduction
Innovator CU10BT-CU5000BT Analog Transmitter Introduction
USEFUL CONVERSION FACTORS
TO CONVERT FROM TO MULTIPLY BY
mile (US statute) kilometer (km) 1.609347
inch (in) millimeter (mm) 25.4
inch (in) centimeter (cm) 2.54
inch (in) meter (m) 0.0254
foot (ft) meter (m) 0.3048
yard (yd) meter (m) 0.9144
mile per hour (mph) kilometer per hour(km/hr) 1.60934
mile per hour (mph) meter per second (m/s) 0.44704
pound (lb) kilogram (kg) 0.4535924
gallon (gal) liter 3.7854118
U.S. liquid
(One U.S. gallon equals 0.8327 Canadian gallon)
fluid ounce (fl oz) milliliters (ml) 29.57353
British Thermal Unit watt (W) 0.2930711
per hour (Btu/hr)
horsepower (hp) watt (W) 746
NOMENCLATURE OF FREQUENCY BANDS
FREQUENCY RANGE DESIGNATION
3 to 30 kHz VLF - Very Low Frequency
30 to 300 kHz LF - Low Frequency
300 to 3000 kHz MF - Medium Frequency
3 to 30 MHz HF - High Frequency
30 to 300 MHz VHF - Very High Frequency
300 to 3000 MHz UHF - Ultrahigh Frequency
3 to 30 GHz SHF - Superhigh Frequency
30 to 300 GHz EHF - Extremely High Frequency
LETTER DESIGNATIONS FOR UPPER FREQUENCY BANDS
LETTER FREQ. BAND
L 1000 - 2000 MHz
S 2000 - 4000 MHz
C 4000 - 8000 MHz
X 8000 - 12000 MHz
Ku 12 - 18 GHz
K 18 - 27 GHz
Ka 27 - 40 GHz
V 40 - 75 GHz
W 75 - 110 GHz
Technical Manual, Rev. 0 8
Innovator CU10BT-CU5000BT Analog Transmitter Introduction
0
-10
-20
-30
-40
-50
-60
-70
S
dB
RETURN LOSS VS. VSWR
R
E
T
U
R
N
L
O
S
1.001 1.01 1.1 2.0
Technical Manual, Rev. 0 9
VSWR
Innovator CU10BT-CU5000BT Analog Transmitter Introduction
ABBREVIATIONS/ACRONYMS
AC Alternating Current
AFC Automatic Frequency Control
ALC Automatic Level Control
AM Amplitude Modulation
AGC Automatic Gain Control
AR A-line, Regenerative Translator
AT A-line, Transmitter
ATSC Advanced Television
Systems Committee (Digital)
AWG American Wire Gauge
BER Bit Error Rate
BR B-line, Regenerative Translator
BT B-line, Transmitter
BW Bandwidth
COFDM Coded Orthogonal Frequency
Division Multiplexing
modulation scheme
CU1000BT C Series, UHF, 1000
Watt, B Version
Transmitter
DC Direct Current
D/A Digital to Analog
DSP Digital Signal Processing
DTV Digital Television
dB Decibel
dBmV Decibel referenced to
1 millivolt
dBw Decibel referenced to 1 watt
FEC Forward Error Correction
FM Frequency Modulation
FPGA Field Programmable Gate
Array
Hz Hertz
ICPM Incidental Carrier Phase Modulation
I/P Input
IF Intermediate Frequency
LED Light emitting diode
LSB Lower Sideband
LDMOS Lateral Diffused Metal Oxide
Semiconductor Field Effect
Transistor
MPEG Motion Pictures Expert
Group
NTSC National Television
Systems Committee (Analog)
O/P Output
PLL Phase Locked Loop
PCB Printed Circuit Board
QAM Quadrature Amplitude
Modulation
SMPTE Society of Motion Picture
and Television Engineers
VSB Vestigial Side Band
dBm Decibel referenced to
1 milliwatt
Technical Manual, Rev. 0 10
Innovator CU10BT-CU5000BT Analog Transmitter System Description
System Description
Depending on the model, the output power level is 10, 60, 100 or 200 Watts
Peak Sync plus Sound using a single Drawer, 600 or 1200 Watts using an
additional single amplifier Drawer, 2500 Watts with two Amplifier Drawers, 3700
Watts with three Amplifier Drawers, or 5000 Watts with four Amplifier Drawers.
The Innovator CXB Series system provides linear and nonlinear correction
capability for the transmission path.
The Drawer contains (A1) Analog Modulator board (1312264), (A3) the IF
Precorrector Board (1308796), (A4) the Frequency Agile Upconverter (1309695),
and (A6) the Amplifier Assembly. The (A7) Output Detector Board (1308685 or
1312207), (A8) the Innovator CX Control Board (1312543), (A9) the +5V, ±12V
Power Supply and (A10) the +24V/+28V/+32V/+39VDC Power Supply are also
contained in the Drawer.
The type of (A6) Amplifier Assembly used in the Drawer changes as the output
power of the system changes. The Amplifier Assembly (1309621) is used in
CU10 systems, the Amplifier Assembly (1312566) is used in CU60 and CU100
systems and the Amplifier Assembly (1312191 or 1315381 w/888A devices) is
used in CU200 systems.
The (A10) Power Supply Assembly also changes as the output power of the
system changes. A +24V Power Supply is used in CU10 systems, a +28V/300W
Power Supply is used in CU60 Systems, a +36V/600W Power Supply operating at
30V is used in CU100 systems and a +48V/1100W Power Supply operating at
39V or 48VDC is used in CU200 systems.
The IF output of the modulator board connects to J2 on the IF pre-corrector
board (1308796). The IF Pre-Corrector Board provides ALC, automatic or
manual, gain control of the IF level. The board also supplies pre-correction
Response, In Phase and Quadrature Non-Linear adjustments. The board has the
circuitry for ALC Fault, Input Fault and Modulation Fault monitoring and
indications. The IF is connected to the upconverter board (1309695) that takes
the 44 MHz or 36 MHz IF signal and converts it to a TV channel frequency in the
range of 54-860 MHz.
The RF on channel signal is fed to the ALC Board, Innovator CXB Series
(1308570), which is used to control the drive power to the RF amplifier chain in
the CU5, CU30, CU50, CU100 and CU200 Transmitters. In a CU60 or CU100, the
RF is connected to the (A6) Amplifier Assembly (1312566) that is made up of
(A6-A1) the 2 Stage UHF Amplifier Board (1308784) and (A6-A2) the RF Module
Pallet, High Output (1309580). The assembly has approximately 36 dB of gain.
The amplified output connects to the (A7) Output Detector Board (1312207)
which provides forward (2V=100%) and reflected (2V=25%) power samples to
the CU Control Board (1312543) for metering and monitoring purposes. An
output power sample is also supplied to the front panel sample jack J15, which is
a 50 Ohm BNC type. The typical sample value is approximately 60dB down from
the output power level of the Drawer. The RF output is cabled to J2 the “N”
connector RF output jack on the rear panel of the Drawer. In CU10, CU60,
CU100, and CU200 systems the output connects to a mask filter and then the
antenna for your system. In larger systems with one external PA, the RF output
from the driver Drawer, is connected to J1 on the rear panel of the amplifier
Instruction Manual, Rev. 0 11
Innovator CU10BT-CU5000BT Analog Transmitter System Description
Drawer. In CU2000 and higher power systems the RF is connected to a splitter
and then to the inputs of the CU1000 amplifier Drawers.
The CU500 system is made up of a CU100 Drawer and a 500 Watt Amplifier
Drawer. The CU100 is used as a driver that connects to the 500 Watt Amplifier
Drawer and supplies the needed drive level to produce the 500 Watts output of
the system. The control and operating parameters of the 500 Watt Amplifier
Drawer are displayed on the LCD Screen on the CU100 Drawer. In the CU500,
the RF input signal at J1 on the amplifier heatsink assembly is fed to J3 on the
LDMOS amplifier pallet. The amplified output of the pallet, which has
approximately 15 dB gain, is connected to the coupler board before it is cabled to
J2 the RF output jack of the Amplifier Heatsink Assembly. The coupler board
supplies a forward and a reflected power sample to the amplifier control board for
metering and monitoring purposes.
The CU1000 system is made up of a CU100 Drawer and a 1000 Watt Amplifier
Drawer. The CU100 is used as a driver that connects to the CU1000 Amplifier
Drawer and supplies the needed drive level to produce the 500 Watts output of
the system. The control and operating parameters of the 1000 Watt Amplifier
Drawer are displayed on the LCD Screen on the CU100 Drawer. In the CU1000,
the input RF signal at J1, located on the rear panel of the Drawer, is fed to J1 on
the 4 Way Splitter Board, which supplies four outputs, one to each 878 amplifier
pallet. Each amplifier pallet has approximately 14 dB gain. The amplified
outputs of the pallets are combined in the 4 Way combiner board whose output is
at J1. The RF is connected to J2 the 7/16” (1.1cm) Din RF output jack located on
the rear panel of the Drawer. The 4 way combiner board supplies a forward and
a reflected power sample to the amplifier control board for metering and
monitoring purposes. In a CU1000, the typical sample value at J6, a 50Ω BNC
jack located on the front panel of the Drawer, is approximately 65dB down from
the output power level of the Drawer.
In higher power systems, multiple amplifier Drawers are used along with splitters
and combiners to produce the desired output. A System Metering Board
(1312666) provides forward, reflected, overtemperature and other parameters to
the exciter/driver Drawer from the external power amplifier chain. The CU2000
is made up of a CU100 driver Drawer, a two way splitter, two CU1000 amplifier
Drawers and a two way combiner with a 500W reject load. The reject load
provides isolation protection of the operating power amplifier if the other
amplifier fails. One–half the power of the operating amplifier Drawer connected
to the combiner will be dissipated by the reject load with the other half of the
power going to the output filters and the antenna. The CU3400 is made up of a
CU100 driver Drawer, a three way splitter, three CU1000 amplifier Drawers and a
three way combiner with reject load. The CU5000 is made up of a CU100 driver
Drawer, a four way splitter, four CU1000 amplifier Drawers and a four way
combiner with reject load.
The On Channel RF output of the amplifier Drawer either connects directly to the
low pass filter and the mask filter then to the antenna in single amplifier systems
or to a combiner, the low pass filter and a mask filter and finally to the antenna
in multiple amplifier systems.
Instruction Manual, Rev. 0 12
Innovator CU10BT-CU5000BT Analog Transmitter Unpacking, Installation
& Maintenance
Unpacking, Installation and Maintenance
Unpacking
Axcera certifies that upon leaving our facility all equipment was undamaged and in proper
working order. It is imperative that all packages be inspected immediately upon arrival to
verify that no damage occurred in transit to the site. Inspect all packages for exterior
damage and make note of any dents, broken seals, or other indications of improper handling.
Carefully open each package and inspect the contents for damage. Verify that all materials
are enclosed as listed on the packing slip. Report any shortages to Axcera. In the event any
in transit damage is discovered, report it to the carrier. Axcera is not responsible for damage
caused by the carrier. If the equipment is not going to be installed immediately, return all
items to their original packaging for safe storage. Save all packing material for future use. If
equipment is ever removed from the site, the original packaging will ensure its safe transport.
A1
Exciter/Driver
A2
Power Amplifier
A3
Power Amplifier
Figure 1: CU2000BT Front View Typical Racking Plan
Installation
The Innovator CXB Series transmitters are designed for simple installation. Expensive test
equipment is not required for installation and set up and to keep a system operational. An
information decal, with Voltage Range, Current Range, Manufacturer, Model and ratings is
attached to the rear panel of the stand alone Drawer or if mounted in a cabinet, to the top of
the frame above the door facing the rear of the cabinet. Prior to installing the product, review
the following items. Check that they been installed, tested and/or inspected.
Building Structure
Electrical Systems
Heating and Air Conditioning
Receive Antenna or Satellite Dish and input cabling
Transmit Antenna and output transmission line
Instruction Manual, Rev. 0 13
Innovator CU10BT-CU5000BT Analog Transmitter Unpacking, Installation
& Maintenance
The Innovator CXB Series systems are 17” (43.2cm) wide standard rack mountable Drawers.
They are supplied with side mounted Drawer Slides for ease of installation and removal. The
CU10, CU60, CU100 & CU200 systems are single Drawer 3 RU, 5.25” (13.3cm), high. The
CU500 and CU1000 systems are two Drawers 9 RU, 15.75” (40cm) high, which is 3 RU, 5.25”
(13.3cm) for the CU100 driver and 6 RU, 10.5” (26.7cm) for the 500 watt or the 1000 Watt
Innovator CXB Series amplifier Drawer. The CU2000 systems are three Drawers 15 RU,
26.25” (66.7cm) high, which is 3 RU, 5.25” (13.3cm) for the CU100 driver and 12 RU, 21”
(53.4cm) for the two Innovator CXB Series amplifier Drawers. The CU3400 systems are four
Drawers 21 RU, 36.75” (93.3cm) high, which is 3 RU, 5.25” (13.3cm) for the CU100 driver and
18 RU, 31.5” (80cm) for the three Innovator CXB Series amplifier Drawers. The CU5000
systems are five Drawers 27 RU, 47.25” (120cm) high, which is 3 RU, 5.25” (13.3cm) for the
CU100 driver and 24 RU, 42” (106.7cm) for the four Innovator CXB Series amplifier Drawers.
Also needed is a mask filter on the broadcast channel that connects to the output of the CU10
thru CU5000 systems. Space must be provided for this filter and in some systems, for the
splitter, combiner, and low pass filter whose dimensions will vary depending on manufacturer
and channel. Refer to the vendor supplied information included with your RF System for
specific dimensions. In some systems, a low pass filter is connected after the amplifier
Drawer(s) and the mask filter. Space must be provided for the low pass filter whose
dimensions will vary depending on manufacturer and channel. Refer to vendor supplied
information included with your low pass filter for specific dimensions. Make sure that the
space provided for the CX Series equipment is sufficient and includes the splitters, combiners
and external filters. Check that any additional equipment, which is included in the system
that extends above or to the side of the mounting rack, has sufficient clearance space. Refer
to the custom racking plan for the system, if prepared, for detailed information.
Drawer Slide Installation
If the system is pre-mounted in a cabinet skip this section. Locate the Drawer slides included
in the installation material for your system. See Figure 2 and the manufacturers instructions,
included with the Drawer slides, for the cabinet mounting instructions of the Drawer slides.
Allow 3 RU, 5.25” (13.3cm) of space between the Drawers for a CU10, 60, 100 or 200 systems.
In high power systems, allow a space of 3 RU, 5.25” (13.3cm) for the CU100 driver and 6 RU,
10.5” (26.7cm) for each of the Innovator CXB Series amplifier Drawers in higher power
systems. Space must also be provided for the splitter, combiner, NTSC filter and low pass
filter, if present, whose dimensions will vary depending on the manufacturer and the output
channel. Install the left Drawer slide into the left side of the cabinet (as viewed from the rear).
Secure the left Drawer slide by connecting it to the front and rear mounting bars using No. 10
screws and the bar nuts that have been provided. Install the Drawer slide on the right side of
the cabinet (as viewed from the rear) making sure that it is aligned with the Drawer slide on the
left side. Secure the slide by connecting it to the front and rear mounting bars using No. 10
screws and the bar nuts that have been provided. Repeat this process for any other Drawers if
purchased. With both slides in place, slide the Drawer or Drawers into the cabinet.
Instruction Manual, Rev. 0 14
Figure 2: Chassis Trak Cabinet Slides
Innovator CU10BT-CU5000BT Analog Transmitter Unpacking, Installation
& Maintenance
AC Input Connections
Refer to Figures 3 and 4 that follow for the location of the jacks and connectors of the system.
The CU10, CU60, and CU100 single Drawer systems will operate with an input voltage of 85253VAC. CU200 single Drawer systems operate on 185-253VAC. The customer should provide
a single point breaker or disconnect for the main AC input connection to the transmitter. Check
that the AC switch, located on the rear of the Drawer above the AC power jack, is OFF.
Connect the AC power cord supplied with the Drawer from J6 on the rear of the Drawer to the
AC source.
If your system is a CU500 or CU1000, it also contains one 500 Watt or 1000 Watt amplifier
Drawer. In CU2000 and higher power systems, multiple 1000 Watt amplifier Drawers are
included. Each amplifier Drawer is configured for 230 VAC operation only. Check that the
ON/OFF circuit breakers, located on each side of the AC power jack, are OFF. Connect the AC
power cord supplied with the Drawer from J10 on the rear of the Drawer to the 230 VAC source.
Refer to Table 1 for the typical voltage and current requirements for CXB Systems.
If the system is mounted in a cabinet, an AC distribution panel is used to connect the AC to the
individual Drawers. The AC distribution panel is mounted facing the rear of the cabinet and
accessed through the back of the cabinet. The main AC input for a CU2000BT transmitter is,
195-235VAC, at least 30Amps, 50/60Hz. The customer should provide a single point breaker or
disconnect for the main AC input that connects to the transmitter. The AC input lines connect
to the AC distribution panel by first removing the four #8 screws that hold the cover plate to
the front of the AC distribution panel. Then connect the three wire main AC input to the input
lugs located at the top left of the AC distribution panel, L1 to L1, L2 to L2 and Ground to the
Ground lug on the left.
The AC distribution panel has three circuit breakers that distribute the AC to the individual
Drawers, which are the Exciter and the two power amplifier Drawers, in the system. The circuit
breakers, which are accessed through the rear door of the cabinet, supply the AC though AC
line cords, that connect to the AC input jacks mounted on the rear panels of the Drawers. CB1
is a 30 Amp circuit breaker which supplies the AC to the (A2), top, Power Amplifier A Drawer.
CB2 is a 30 Amp circuit breaker which supplies the AC to the (A3), bottom, Power Amplifier B
Drawer. CB3 is a 10 Amp circuit breaker which supplies the AC to the (A1) Exciter/Driver
Drawer. The circuit breakers are accessed through the rear door of the cabinet.
Instruction Manual, Rev. 0 15
Innovator CU10BT-CU5000BT Analog Transmitter Unpacking, Installation
J1
J6
J14
J13
J2
TB1
& Maintenance
Table 1: CXB Series Analog Systems Typical AC Input and Current Requirements.
System
Output
Power
CU10BT/CU0T-1 10 Watts 190 Watts
CU60BT/CU0T-2 50 Watts 310 Watts
CU100BT/CU0T-3 100 Watts 500 Watts
Power
Consumption
Voltage Current
115 VAC 1.7 Amps to the Cabinet
230 VAC 1 Amps to the Cabinet
115 VAC 2.7 Amps to the Cabinet
230 VAC 1.4 Amps to the Cabinet
115 VAC 4.4 Amps to the Cabinet
230 VAC 2.2 Amps to the Cabinet
CU200BT/CU0T-4 200 Watts 1000 Watts 230 VAC 4.3 Amps to the Cabinet
CU600BT/CU1T-1 600 Watts 1900 Watts 230 VAC 8.3 Amps to the Cabinet
CU1200BT/CU1T-2 1200 Watts 4000 Watts 230 VAC 17.4 Amps to the Cabinet
CU2500BT/CU2T 2500 Watts 7200 Watts 230 VAC 31.4 Amps to the Cabinet
CU3700BT/CU3T 3700 Watts 13000 Watts 230 VAC 56.6 Amps to the Cabinet
CU5000BT/CU4T 5000 Watts 17000 Watts 230 VAC 73.9 Amps to the Cabinet
Input and Output Connections
The input and output connections to the system are made to the jacks mounted on the rear
panels of the CU10 thru CU200 systems, the drivers for the CU500 and high power systems,
and to the 500 Watt and 1000 Watt amplifier Drawers. The CU10 thru CU200 systems and
the drivers for the CU500 and higher power systems accept baseband audio and video inputs
and output a RF ON Channel signal. Refer to Figure 3 and to Table 2 that follow for the
locations and information on the jacks and connectors.
J9
J11
J12
Figure 3: Rear View CU10 thru CU200 and the driver for the CU500 and higher power
systems
Table 2: Connections for the CU10 thru CU200 and the driver for the CU500 & higher
power Systems
AC Input: AC input connection to 85-264VAC Source and
On/Off circuit breaker
Power Monitoring: Interface to System and external
amplifier Drawers, if present. Also provides an interlock for
the Reject Load (if used).
Instruction Manual, Rev. 0 16
J10
N/A
N/A
Innovator CU10BT-CU5000BT Analog Transmitter Unpacking, Installation
J1
J3
J2
CB1
CB2
& Maintenance
Port Type Function Impedance
J12
J13 RJ-45
J14 RJ-45
15 Pos
Female D
Remote: Remote control and status indications N/A
Serial: Provides communication to System and to external
amplifier Drawers, if present.
(Optional) Ethernet: Ethernet connection. May not be
present in your Drawer.
N/A
N/A
J15
Front
Panel
BNC
RF Sample: Output Sample from Output Detector Board.
In a CU30, CU50, CU100 & CU125, the sample level at J15
is approximately 60dB down from the output power level of
50 Ohms
the Drawer.
J16
Front
Panel
9 Pos
Female D
Serial: (Not Used) N/A
Connect the Video Input to the BNC Input A jack J1. Connect the Composite Audio Input to
the BNC Input B jack J2 or the Balanced Audio Input to the terminal connections on TB1, – to
terminal 1, + to terminal 2 and ground to terminal 3.
Connect the external 10 MHz reference input to the 50Ω BNC 10 MHz input jack J6 located on
the rear panel of the CU100BT.
The analog RF ON Channel output of the CU100BT is at J9 the 50Ω “N” connector RF output
jack. The output of the drawer at J9 connects to 2 way splitter and then to the two CU500B
amplifier trays.
J4
J5
Figure 4: Rear View CU500 and CU1000 Amplifier Drawer
Table 3: Connections for the CU500 and CU1000 Amplifier Drawer
Port Type Function Impedance
J1 N RF Input: On Channel RF from CU driver Drawer 50Ω
7/16”
J2
(1.1cm)
RF Output: On Channel RF Output 50Ω
Din
J3 IEC AC Input: AC input connection to 230VAC Source N/A
J4 9 Pos D
Remote: Amplifier Control Interface
(Connects to J11 on the driver Drawer)
N/A
Instruction Manual, Rev. 0 17
Innovator CU10BT-CU5000BT Analog Transmitter Unpacking, Installation
& Maintenance
Port Type Function Impedance
J5 RJ-45 Serial data N/A
J8
Front
Panel
BNC
RF Sample: Output Sample from Combiner thru Control
Board. In a CU1000, the sample level is approximately
70dB down from the output power level of the Drawer.
50Ω
The RF ON Channel output of the CU10 thru CU200 systems and the driver Drawers is at J9
the 50Ω “N” connector RF output jack located on the rear panel. In CU10 thru CU200
systems, the output of the Drawer at J9 connects to the analog filter and then to the antenna
for your system. In CU500 and higher power systems, the output of the driver Drawer at J9
is connected to J1 the 50 Ohm “N” connector RF input jack located on the rear panel of the
500 Watt digital/1000 Watt analog amplifier Drawer or to a splitter in multiple amplifier
systems. Check that the system power metering interface cable is connected from J11 the 9
position “D” connector located on the rear panel of the driver Drawer to J4 the 9 position “D”
connector located on the rear panel of the 500 Watt/1000 Watt amplifier Drawer. This cable
provides the control, status and operating parameters of the amplifier Drawer to the driver
Drawer. The RF ON Channel output of the amplifier Drawer is at J2 the 50Ω “7/16” (1.1cm)
Din connector RF output jack located on the rear panel that connects directly to the low pass
filter, the mask filter and then to the antenna for your system in single amplifier systems or
to a combiner and then the low pass filter, the mask filter and finally to the antenna in
multiple amplifier systems.
Maintenance
Innovator CXB Series Transmitters are designed with components that require little or no
periodic maintenance except for the routine cleaning of the fans and the front panels of the
modules and the periodic check of general tightness of hardware.
It is recommended that periodically, the time interval depends on the amount of movement the
cabinet receives, all mounting hardware, holding drawer slides, shelving and mounting plates
inside the cabinet are checked for tightness. All screws and bolts that are accessible should be
tightened initially when the transmitter is received and periodically thereafter if the transmitter
is moved by vehicle. All coaxial connectors, hard-line connections and hardware holding
combiners, splitters, or any other mounted items should be checked and tightened. The
amount of time between cleanings of the drawers and cabinets depends on the conditions
within the transmitter room. While the electronics have been designed to function even if
covered with dust, a heavy buildup of dust, dirt, or insects will affect the cooling of the
components. This could lead to a thermal shutdown or the premature failure of the affected
drawer. When the front panels of the drawers become dust covered, the drawer should be
pulled out and any accumulated foreign material should be removed. NOTE: To remove the
CXB series transmitter from the cabinet, the input and output cables must be removed from the
rear of the transmitter before the drawer can be pulled out completely from the cabinet.
A vacuum cleaner, utilizing a small, wand-type attachment, is an excellent way to suction out
any dirt from the drawer and cabinet. Alcohol and other cleaning agents should not be used
unless you are certain that the solvents will not damage components or the silk-screened
markings on the drawers and boards. Water-based cleaners can be used, but do not saturate
the components. The fans and heatsinks should be cleaned of all dust or dirt to permit the free
flow of air for cooling purposes. It is recommended that the operating parameters of the
transmitter be recorded from the LEDs and the LCD system metering on the front panel of the
drawer at least once a month to be used for comparison purposes in case of a failure. It is
suggested that this data be retained in a rugged folder or envelope and stored near the
transmitter.
Instruction Manual, Rev. 0 18