Avue High Speed dome Camera, Outdoor 18x with WDR, Outdoor 26x with WDR, Outdoor 36x with WDR User Manual

Page 1
High Speed dome Camera Series
USER'S MANUAL
v 2.66
Page 2
WARNING
CONTENTS
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. DO NOT INSERTANY METALLIC OBJECTS THROUGH THE VENTILATION GRILLS OR OTHER OPENINGS ON THE EQUIPMENT.
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
CAUTION: TO REDUCE THE RISK
OF ELECTRIC SHOCK, DO NOT
REMOVE COVER ( OR BACK). NO
USER SERVICEABLE PARTS
INSIDE. REFER SERVICING TO
QUALIFIED SERVICE
PERSONNEL
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
FCC INFORMATION: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT. THIS EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO FREQUENCY ENERGY AND IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTION MANUAL, MAY CAUSE HARMFUL INTERFERENCETO RADIO COMMUNICATIONS. OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCEAT HIS OWN EXPENSE.
1. Precaution......................................................1
2. Features.........................................................2
3. Packing list.....................................................3
4. Installation...................................................... 4
5. Operation........................................................10
6. OSD................................................................11
7. Adress and Protocol Setting................................20
8. Specifications..................................................25
8. Motion Tracking..................................................26
CAUTION: CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USERS‘S AUTHORITY TO OPERATE THE EQUIPMENT.
CE COMPLIANCE STATEMENT
WARNING: THIS IS A CLASS A PRODUCT. IN A DOMESTIC ENVIRONMENT THIS PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED TO TAKEADEQUATE MEASURES.
CAUTION: BEFOREATTEMPTING TO CONNECT OR OPERATE THIS PRODUCT, PLEASE READ THE LABEL ON THE BOTTOM AND USER'S MANUAL CAREFULLY
Technical specification are subjects to change without prior notice. Manual may contain mistake or print error. All trademarks mentioned belong to their respective owners.
Page 3
1.PRECAUTION
2.FEATURES
Refer all work related to the installaion of this product to qualified service personnel or system installers.
Do not attemp to disassemble the appliance
To prevent electric shock, do not remove screws or cover. There are no user­serviceable parts inside. Contact qualified service personnel for maintenance
Handle the appliance with Care
Do not strike or shake, as this may damage the appliance. It should be protected against extreme pressure, vibration and humidity during transportation and storage. Damages caused by improper transportation avoid the warranty.
Do not use strong or abrasive detergents when cleaning the appliance body and transparent cover.
Use a dry cloth to clean the appliance when it is dirty. When the dirt is hard to remove, use a mild detergent and wipe gently.
Do not operate the apliance beyond its specified temperature, humidity or power source ratings.
Do not use the dome camera in an extreme environment where high temperature or high humidity exists. Use the within -10°C to +50°C(14°F to 122°F) and a humidity below 90%. The input power source is 24V AC, 50/60Hz and requires 1000mA. Use the within -20°C to +60°C(-4°F to 140°F) and a humidity below 90%. The input power source is 24V AC, 50/60Hz and requires 2500mA.
Do not expose the indoor model of dome camera to water or moisture, not try to operate it in wet areas.
Take immediate action when the indoor speed dome becomes wet. Turn off the power and refer servicing to qulified service personnel. Moisture may damage the appliance and cause eletric shock.
Do not point the camera lens directly to sunlight or any strong light source.
This will cause permanent damage to the camera and avoids the warranty.
Read this user's manual carefully before operating the appliance.
Make sure that local electric safty standard are followed when using or installing the appliance
indoor models
outdoor models
The high speed dome camera series are designed for in- and outdoor video surveillance application. The integrated, motorized pan-tilt mechanic allows user to point the camera to any position( 360° horizontal and 180° vertical). Both series can be equipped with digital zoom camera modules, which provide zooming functon from 18 to 36 times (optical) and advanced image features.
Key features:
- 360° Pan and 180° Tilt range (90° with auto-image-flip)
- Support most well-known camera modules
- 128 preset points memory (80 can be used for auto tour function)
- 4 patt ern tou rs
- 1 Scan t our
- Basic setup directly from Keyboard.
- Advanced setup through OSD (On Screen Display) menu.
- up to 24 privacy masking zones ( despends on camera module)
- 7 alarm input & 2 output ( 4 input & 1 output pre-wired)
- Multi-Protocol through Rs485 or coaxial cable.
- Dirction Indicator on screen
- Aluminum Alloy structure with high intensity and heat-sinking
- High-precision step-motor for flicker-less image during movement.
Camera Features:
- HighResolution with 560TVL and Wide-Dynamic*
- Interlace and Progressive Scan*
- Auto-Focus
- Auto-Iris
- Auto- Brightness control
- Auto-Balance
- IR cutter control, Day-Night mode switching.
- Auto Slow-Shutter
- Electric Image Stabilization
- Stablezoom*
Temperature monitoring and protection
- Alarm notification will be displayed once the inner temperature exceeds the limit
- In low temperature area, the dome camera will only start after the operation temperature is reached.
- Cooling fan activity is managed by the CPU ( extends the duration)
Do not install the camera in other orientation as designed.
And do not bend or squeez the sturctiure, as this may damage the mechanic sturcture of the appliance and avoids the warranty.
Do not touch the Cover with bare hands or any object.
These will scratch the serface and affect the image qulaity.
12
Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
Other features:
- Proportional pan for Focus / Speed on different zoom factor.
- Auto-resuming user-defined action, such as tour, pattern or scan after selectable idle time.
- Power-upAction activates tour or pattern by default.
depends on camera module type.
*
Page 4
3.PACKING LIST
4.INSTALLATION
Indoor Series
Outdoor Series
Outdoor Series
Core Unit 1 Piece
Core Unit 1 Piece
Core Unit 1 Piece
Indoor Roof-Mount base platte 1 piece
Out-Door housing with sun.shield and
cover
1 piece
Out-Door housing with sun.shield and
cover
1 piece
High Speed dome Camera Series
USER'S MANUAL
Instruction and operation manual 1 piece
Spare dome cover 1 piece
Spare dome cover 1 piece
High Speed dome Camera Series
USER'S MANUAL
Instruction and operation manual 1 piece
High Speed dome Camera Series
USER'S MANUAL
Instruction and operation manual 1 piece
Safety Instructions before starting
- Do not install and operate this appliance in a flammable and explosive environment.
- Make sure that the installation is done according to the local electricity safety regulation of your country. .
- Before installation and mentainence, make sure that the appliance is disconnected from the power source.
- Do not use any power source other than 24V AC, in order to prevent damages to this device. For details, please refer to the section "Precaution" in previous chapter for more details.
- Handle the device during the installation carfully. Falls or extreme vibration may cause irrepairable damages and avoid the warranty.
- Do not install or operate the appliance near any high-voltage devices or high-voltage cable. The safety distance should remain at least 50 m.
- To archive best image quality, its recommanded to use underground cable shielded with steel tube. Do not install the cable without any protection.
- In a thunderstorm area or region with high inductive voltage, such as high voltage transformer stations, it is necessary to use additional lighning-proof equipments or lightning rob for protection.
- For outdoor installation, lightning-proof and grounding of the device should be considered. Please refer to the industrial saftey regulation and request of your country .
- Grounding of the appliance should consider anti-interference and fulfill the saftey requirements. Do not connect the ground with short-circuited or other high-voltage electric network.
WARNING:
be handled with care. Do not touch or rub the surface in any way with the protection foil.Inproper cleaning method will cause permanent scratches on the cover and cause unclear image or focusing error of the camera. For Cleaning the cover, please replace the original first with the spare cover, and wash it by diving into warm water with non-corrosive cleaning solution.
The transparent cover part is sensitive and should
Unpacking
The speed dome is packed with protection. please take out the core unit carefully. In case of transportation please use the original packing box.
3
Some models may not be available in your country, please contact VIDO distributor for more details
- The resistance of down conductor should not exceed 4 Ohm, and its thickness should be at least 25mm²
- This appliance has the lightning-proof function which can prevent damages caused by high-voltage pulse, such as lightning strike below 1500.
- This appliance meets the Ip66 standard for water and dust proof. Do not install the in­door model for out-door application which is not designed with water protection. Make sure that the installation is protected from long-time water-drop or spatter, which may damage the appliance.
- Make sure that the enviroment of installation meets the requirement of the appliance, such as holding the weight, enough spaces for bracket and power supply.
Some products may not be available in your country, please contact our distributor for more details
4
Page 5
4.INSTALLATION
4.INSTALLATION
Connector description
The wiring cable of the PTZ camera provides connectors for power supply, video and I/O interface
RED: AC 24V BLACK: AC 24V
Power
To power supply
Connector
Green:RS485+
RS485 Connector RJ-11
Yellow:RS485-
To Keyboard or DVR decives for telemetric control
Inner Conn: Signal + Outer Conn: Ground
Video output
Video Output to monitor or DVR
BNC
Using optional accessories
The speed dome cameras can be connected to various optional accessories through the standard connector types, which simplifiy the cable handling and avoids possible mistakes. All accessories are tested for max. compatibility and best performance.
Outdoor power adaptor box AC 230V to AC 24V
AC 24 Power
supply
RS 485
Alarm I/O
AC 230V
Power input
Indoor power adaptor AC 230V to AC 24V
AC 24 Power supply
AC 230V Power input
3-Axis keyboard
controller
RS 485
21”High Res. security Monitor.
Professional Real-time 16 Channel DVR
Telemetric control camera setup
RED: Alarm in 1 PINK: Alarm in 2 YELLOW: GREEN: BLACK: COM WHITE: Alarm output - N.O
Alarm I/O 1
BLUE: Alarm output - N.C
AQUA BROWN: Alarm output - N.O2 GRAY: Alarm in 7 PURPLE: Alarm in 6 ORANGE: Alarm in 5
I/O interface to additional alarm sensor
Alarm I/O 2
56
Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
or control devices
Alarm in 3
Alarm in 4
Alarm output - N.C2
:
RS 485 cable
The telemetric control of the appliance uses Rs485 serial communication with half­duplex transmission technology. Depends on the cable typeand baud rate, the transmission distance could vary. The following table shows max. distances based on cable with 0,56mm (24AWG) twisted pair:
Baud Rate
2400 bps 4800 bps
9600 bps
19200 bps
Max. Distance
1700m
1100 m
700m
4oom
Video signal
Due the environmental interferences, such as eletromagnetic and induction fields, or number of connected appliance on the RS-485 bus, the transmission range may be less, e.g with cable thinner than than 24AWG.
Page 6
4.INSTALLATION
4.INSTALLATION
RS-485Termination
Devices using Rs485 control are usually connected in daisy-chain. which reqiuers termination with 120 resistor on both ends. Following picture illustrates the
Ω
connection methods. please note that a daisy-chain connection type shall not exceed 7 meters.
120
Resistor
RS 485+
Ω
Device 2 Device 3Device 1
RS 485-
120
Resistor
Ω
The PTZ cameras provide integrated termination switch. It should be turned on when the dome is installed as the last device. If the controller keyboard is used, you need also to turn on the termination on it. please refer to the keyboard’s manual for details.
RS 485+
RS 485-
Termination on
Termination on
Termination off
Termination off
How to turn on termination on the high speed dome camera
The termination switch is located on the rear side of the connection board. For switching on, you need to open the
Star-Connection
The star-form connection is mostly used. it enables the connection of different dome cameras in longer distance. It is recommended to use RS-485 distributor to ensure the
telemetric data transmission:
The advantage of star-connection is that every channel can work
RS-485 cable up to 1000m per channel
RS-485 Distributor
Termination on
Termination activated on every end.
independently and take a cable length up to 1000 meters( depends on cable quality). In case more dome camera are installed, the star­connection can be extended with additional RS-485 distributors.
Video Cable
coaxial cable with 75 impedance with copper conductor at center conductor, and
Ω shielded with 95% copper. The following table shows different cable type and its maximum length:
Cable standard
RG 59 /U
RG 6 /U
RG 11 /U
Max. Distance (m /ft )
229m / 750 ft
305m/ 1000 ft
457m / 1500 ft
The values are for reference only. Depends on the cable quality and environmental condition, the transmission distance might be less.
If the cable length is more than 400 m, it is recommended to use optional accessories, such as video amlifier or twisted-pair video converter , for boost the video signal.
How to open the connector board
The connector board can be easily
rear side
123
Termination Jumper
Jumper
Term. On
7
Some products may not be available in your country, please contact our distributor for more details
Term. Off ( default)
123
ON
ON OFF ON
OFF
opened by holding the metal clip and pull.
ON
Metal Clip holder
Pres s the met al clip in and pull the board on this direction.
Up to 750m, coaxial cable
VideoAmplifier (optional)
Extend connection distance with video amplifier
Up to 1200m, twisted pair or cat.5 cable
transmitter
(optional)
Extend connection distance with Twisted-Pair video converter
Some products may not be available in your country, please contact our distributor for more details
Real time DVR Center
TP receiver (optional)
Real time DVR Center
(optional)
(optional)
High Res Monitor (optional)
High Res Monitor (optional)
8
Page 7
4.INSTALLATION
5.OPERATING THE SPEED DOME
Installing the core unit to base board.
The PTZ camera core unit and base board are packed seperatly, in order to be protected through the transportation. After unpaking and during the installation, the core unit should be installed as following:
Installing the core unit by pushing into the housing.please note the position of connector. For releasing, please press the lever-lock to core and pull off the unit.
Once the base board is connected to power, the power LED will light.
Connector Interface
Power LED
Metal Clip
WARNING: Do not pull or hold the connector interface with force. It is design only to connect the core unit and the base board. Any presure on connector will cause damage and avoids the warranty.
Heater connector on outdoor housing
Screws
Rubber ring
Outdoor housing cover
cable
Lever­Lock
Safety spring
Heater connector
Optional bracket accessories
The PTZ cameras can be equipped with various bracket accessories for indoor and outdoor installation. please contact your distributor for further details.
Initial Screen
FIRMWARE V2.61 Protocol: PELCO Dome Address: 001 Comm 9600,N,8,1
- V2.61:
- Protocol:
Current firmware version
control protocol which currently used
- Dome address:
Address ID of speed dome. please refer to the section "Protocol
After powering up, the camera will enter the self-test mode and display the status screen( as in the picture left).It contains information about the model and current settings.
setup " for details.
- Comm 9600,N,8,1:
Baud rate. please refer to section "Baud-Rate setup" for details
9600: N, 8, 1:
No parity bit, 8 bit length, 1 stop bit. this setting can not be changed
current setting of the serial communication interface.
The intial screen will stay remain on until any user action is being taken. If the power­up action is set, the initial info wil vanish immediatly.
Operation Screen
Temperature
The operation screen can display additional information.
32.0CAM TITLE
Temperature: current temperature inside the speed dome( °C) Cam title: User definable camera title Zone: Current zone name
ZONE-1 285 78 18X
Pan deg.: Pan angle, 0-359° Tilt deg.: Tilt angle, 0-90° Zoom Factor: Zoom factor
Zoom factor
Ceilling mount
Wall mount and
Power box
Corner Mount
Indoor Wall mount
Pole Mount
Outdoor Power Box
Display of the information can be activate or deactivate through the OSD menu. please refer to the system setting for detais.
PTZ operation
Tilt degree Pan degree
Zone description
For the surveillance operation, the dome can be controlled from a keyboard device, Multiplexer or DVR through RS-485 Interface. Make sure that the cable is connected and the settings (baud rate,Address ID and protocol) of both keyboard and the dome are configured correctly. For more description about the PTZ operation, please refer
Indoor embedded mount
910
Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
Indoor ceilling mount
Extended wall mount
Swan-Neck Mounting bracket
Wall mount
to the user’s manual of the keyboard.
Page 8
OSD
OSD Menu
The PTZ cameras are equipped with new OSD-Menu function. All operation functions and camera related settings can be changed or modified here. In order to use the OSD function, a telemetric controller device, such as Keyboard, DVR or other devices with similiar function is necessarily required. please make sure that the device used is physically connected to the dome properly, and all connection parameters are set correctly.
OSD - MAP
ALARMS SETTING
ALARM NUMBER 001
ALARN ACTION NONE
ACTIVATEAUX NONE
ALARM PRIORITY
BACK
EXIT
ARM SETTING
DAY SUN
UNARM TIME N/A
ARM STATE OFF
ARM TIME N/A
BACK
EXIT
How to start the OSD menu
To start the OSD Menu, you need to press following key on the keyboard:
2-Axis
With or
keyboard
3-Axis
With or
keyboard
call
Shot
9 5
9 5
Enter
Enter
2 X
2 X
call
Shot
Enter
9
Enter
9
In case a DVR is used for the OSD, select “goto preset 95” or 2 X “goto preset 9”. Please refer to the DVR’s operation manual for more details.
Note that in some certain situations, it is not possible to enter the OSD menu:
1. the dome is running tour
2. performing PTZ operation
3. dome is receiving command other than OSD-request from the keyboard.
please stop the operation and try again.
Main menu and navigation
After entering the OSD Menu, the screen will show menu items . Use the controller’ joystick to navigate through
Main Menu
the menu’s main and sub items by moving in the direction. The angle mark on the beginning of every
SYSTEM SETTING
items indicates the selection. CAMERA SETTING FUNCTION SETTING WINDOW BLANKING ALARM EXIT
UP, DOWN: - Moving between current menu items
- Changing the value in subitems
RIGHT: - Enter the selected menu item
- Confirm the value change and return to
item selection
LEFT: Exit from sub menu
For more inforamtion, please refer to the illustration on
the next page for the OSD menu structure.
Symbols and indicator
Cursor.
Sub item is selected. use up or down to change value
This item has subitem(s)
MAIN MENU
SYSTEM SETTING
CAMERA SETTING
FUNCTION SETTING
WINDOW BLANKING
ALARMS
EXIT
ALARMS
RESUME OFF
SEQUENCE 60
RESET DELEY 030
ALARM CONTACT N/O
ALARM SETTING
ARM SETTING
WINDOW BLANKING
WINDOW NUMBER 01
EDIT WINDOW
ENABLE WINDOW ON
CLEAR WINDOW
BACK
EXIT
FUNCTION SETTING
CAMERA SETTING
ZOOM SPEED HIGH
DIGITAL ZOOM ON
BLC MODE OFF
SLOW SHUTTER ON
LINE SYNC N/A
WDR MODE AUTO
ADVANCE SETTING 1
SYSTEM SETTING
EDIT DOME LABEL
INITIAL INFO
DISPLAY SETUP
MOTION
CLEAR
PASSWORDSETUP
BACK
EXIT
PRESETS
SCAN
PATTERNS
ADVANCE SETTING 2
BACK
EXIT
CLOCK SETTING
BACK
EXIT
TOUR
ZONES
TIME RUNNING
ADVANCE SETTING1
AUTO-TRACKING
BACK
PS SCAN O N
ADVANCE SETTING1
IR CUTTER FILTER AUTO
EDIT DOME LABEL
EXIT
LABEL:SPEED DOME
-- -
-- -
-- -
-- -
-- -
EDITTOUR
LABEL: PRESET-01
PRESET NUMBER 001
SET PRESET
MIRRO R OFF
FLIP OFF
INITIAL INFO
BACK
EXIT
SHOW PRESET
NEXT
CLEAR PRESET
EDIT PRESET LABEL
2.66
VIDO B02
SPEED DOME V
PROTOCOL :
DOME ADDRESS: 001
BACK
EXIT
ADVANCE SETTING2
96
COMM: 00 . N.8.1
EDIT SCAN LABEL
LABEL: AUTO SCAN
SCAN
SCAN NU MBER 01
SCAN SPEED 63
SHUTTER N/A
IRI S N/A
BRI GHT N/A
R GAIN N/A
B
AE MODE AUTO
W M ODE AUTO
BACK
EXIT
BACK
SET LEFT LIMIT
B GAI N N/A
DISPLAY SETUP
EDIT PATTERN LABEL
EXIT
PATTERNS
PATTERN N UMBER 1
SET RIGHT LIMIT
CLEAR SCAN
RUN SCAN
EDIT SCAN LABEL
BACK
EXIT
HI-RESOLUION ON
BACK
EXIT
FF
FF
DOME LABEL OFF
PRESET LABEL OFF
ZOOM LABEL O
ZONE LABEL OFF
DIRECTION LABEL O
TEMPERATURE LABEL OFF
TIME LABEL OFF
DATE LABEL OFF
BACK
EXIT
EDIT PRESET LABEL
PRESETS
STABLE Z OOM OFF
DNR 00
BACK
EXIT
IR CUT ON T IME N/A
IR CUT OF F TIME N/ A
THRES HOLD 10dB
MAX GAI N 28dB
EXPOSURE COMP OFF
BACK
EXIT
LABEL: PATTERN-1
BACK
PROGRAM PATTERN
RUN PATTERN
EXIT
CLEAR PATTERN
EDIT PATTERN LABEL
BACK
EXIT
ADVANCE SETTING
MOTION
TM TM TM
P0-S- P0-S- P0-S-
TOUR
ESET FREEZE FF
PR N O
EIS ENABLED ON
AUTO FLIP ON
PROPORTION PAN ON
PARK TIME 005
AUTO FOCUS OFF
00-0-00 00 0 00 00 0- 00
NUMBER 1
TOUR
NONE
PARK ACTION
DEFOGGER 015C
00-0-00 00 0 00 00 0- 00
EDITTOUR
NONE
POWER UP ACTION
00-0-00 00 0 00 00 0- 00
RUN TOUR
HEAD UP OFF
FAN ENABLED 040
EDIT ZONE LABEL
LABEL: ZONE-1
BACK
00-0-00 00 0 00 00 0- 00
00-0-00 00 0 00 00 0- 00
CLEARTOUR
BACK
BACK
EXIT
TEMP C/F CENT
ADVANVE SETTING
EXIT
BACK
EXIT
ZONES
ZONES N UMBER 1
EXIT
BACK
EXIT
SETLEFT LIMIT
CLEAR
SETRIGHT LIMIT
CLEAR ZONE
EDITZONE LABEL
CLEAR ALL ZONES
CLEAR ALL PRESETS
BACK
EXIT
CLEAR ALL PATTERNS
CLEAR ALL TOURS
CLEAR ALL WINDOWS
FACTORY DEFAULTS
RESTART
BACK
TIME RUNNING
DAY SUN
EXIT
START TIM E 00:00
RUNNING NONE
TIME CHANNEL 1
BACK
EXIT
PASSWORD SETUP
OLD PASS WORD : ** ****
NEW PASS WORD : ******
CONF PASSWORD : ******
ENABL E PASSWO RD OFF
AUTO-TRACKING
DAY SUN
BACK
EXIT
STATE ON
START TIM E N/A
END TIM E N/A
CLOCK SETTING
SENSITIVE LOW
TRACKING-ZOOM OFF
SETLEFT LIMIT
SETRIGHT LIMIT
BACK
EXIT
TIME 00:00:00
DATE 01/01/01
DAY MON
BACK
EXIT
Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
Page 9
6.OSD - System Setting 6.OSD - Motion, Clear
SYSTEM SETTING
EDIT DOME LABEL INITIAL INFO DISPLAY SETUP MOTION CLEAR PASSWORD SETUP CLOCK SETTING BACK EXIT
EDIT DOME LABEL
LABEL
ENTRANCE
BACK
EXIT
INITIAL INFO
SPEED DOME V1.00 PROTOCOL:FACTORY DOME ADDRESS:001 COMM:4800,N,8,1 BACK EXIT
DISPLAY SETUP
DOME LABEL OFF
PRESET LABEL OFF
ZOOM LABEL ON
ZONE LABEL OFF
DIRECTION LABEL ON
TEMPERATURE
BACK
EXIT
LABEL OFF
System Setting
In system setting menu, you can modify operation and
display setting, such as dome label, temperature and
display of various value on the operational screen.
Dome Label:
1. use UP or DOWN to change the charactor.
2. u se RIG HT to m ove t o next c har.
3. u se RIG HT to m ove t o last c har a nd save.
4. u se Lef t to fi rst ch ar an d canc el.
Initial information:
Shows the information about current setting.
Display setup
Actuvate the display for the on-screen info in operaton
mode.
Dome label:
Preset label:
Zoom label:
Zone label:
Direction label:
Temperature label:
shows the cur. temp in the speed dome
the name of dome
shows the labe of every preset
shows zoom factor on screen
shows the zone name
shows the coordinates
MOTION
AUTO FLIP ON PROPORTION PAN ON PARK TIME 005 PARK ACTION SCAN POWER UP ACTION AUTO FAN ENABLED 040 TEMP C/ F CE NT ADVANCE SETTING BACK EXIT
ADVANCE SETTING
EIS ENABLED N/A PRESET FREEZEN OFF AUTO FO CU S OF F DEFOGGER 015C HEAD UP OFF BACK EXIT
CLEAR
CLEAR ALL ZONES CLEAR ALL PRESETS CLEAR ALL PATTERNS CLEAR ALL TOURS CLEAR ALL WINDOWS FACTORY DEFAULTS RESTART BACK EXIT
Motion control
AUTO FLIP
180°
PROPORTIONAL PAN:
the dome will adjust the pan and tilt speed automatically for comfortable viewing.
PARK TIME:
custom defined action( park action).The range is from 1 to 240 minutes. This function can be deactivated by setting the minute to 0.
PARKACTION:
the idle time (park time). Selectable between Preset, Scan, Pattern (Nr), Tour or None.
POWER UPACTION:
be started after power up and self test. Selectable between Auto,Preset 1, Scan, Pattern (Nr), Tour or None. By selecting Auto, the dome will resume the last action before power off.
FAN ENABLED:
temperature.
TEMP C/F:
Fahrenheit.
: Auto. Image flip in tilt range from 90° to
depends on the zoom factor,
defines the idle time prior to start a
the action which will be started after
defines the action which will
Activate Fan when the dome reach the
Switch the temperature unit between Celius and
Advance Setting
EIS ENABLED: E I S
function is variable on certain camera modul.
PRESET FREEZEN: AUTO FOCUS: DEFOGGER: HEAD UP:
combine with Camera Flip function.
Clear
You can clear setting’s memory or reset the camear to factory default. The follwing functions are supported:
- Clear Zones
- Cl ear al l pre sets
- Clear all patterns
- Clear all tours
- Cl ear al l win dows
- Factory defaults
Warning: The c lear a cti on can n ot be u ndon e. once a item is cleared it is impossible to re trie ve th e del eted s ett i ng. P leas e mak e sur e that the requested clear action is desired.
Enable „ lectric mage tabilization“. This
Freeze the image immediately.
Switch ON/OFF the Auto Focus
Activate Heater/Fan on the cold temperatur.
Switch ON/OFF the proportional PT moving. Can
13 14
Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
Page 10
OSD - Camera Setting OSD - Preset, Scan
PASSWORD SETUP
O
LD PASSWORD : ****** NEW PASSWORD : ****** CONF PASSWORD : ****** ENABLE PASSWORD OFF BACK EXIT
CLOCK SETTING
TIME 00:00:00 DATE 01/01/01 DAY MON BACK EXIT
Password setup
You can change password to access the OSD menu. Default Password is 000000.
Clock setting
Some function like Auto-Tracking require the timer for activation. Time: HH:MM:SS DATE: YY/MM/DD DAY: MON-SUN
CAMERA SETTING
CAMERA SETTING
ZOOM SPEED HIGH DIGITAL ZOOM ON BLC MODE OFF SLOW SHUTTER ON LINE SYNC N/A WDR MODE N/A ADVANCE SETTING 1 ADVANCE SETTING 2 BACK EXIT
In camera setting menu, you can setup camera module related settings. please note that depends on module’s capability, some function may not available. please contact your local sales representative for detailed information.
ZOOM SPEED:
function.
DIGITAL ZOOM:
function of the camera module.
BLC MODE:
improves the image when an object has strong back light.
SLOW SHUTTER:
of the camera, which provides a higher light sensibility in low-environment.
WDR:
Activates the Wide Dynamic Range function, which improves the image contrast when an object has very strong light on background. Only available with camera modules with WDR.
defines the speed when performing zoom
Activate or deactivate the digital zoom
Select the Back Light Compensation mode,
Activates the Slow Shutter function
ADVANCE SETTING1
IR CUT FILTER:
ADVANCE SETTING 1
IR CUTTER FILTER AUTO
IR CUT ON T IM E N/ A IR CUT OF F TI ME N /A
THRESHOLD 10dB MAX GAIN 28dB EXPOSURE COMP OFF MIRROR OFF FLIP OFF NEXT
15
Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
Filter (IRC), also known as “DAY/NIGHT” mode. with the removal of IRC, the camera turns into Black/White mode and has higher sensibility to low-light or IR-Light in the night. Selectable between On, Off, Auto or Time. Only available on camera module with IRC function.
MAX GA IN : EXPOSURE COMP:
of a short exposure.Configure the shutter speed of a long exposure by setting the ratio with regards to a short exposure with the exposure ratio parameter. Blocked-up shadow correction is not performed in this mode.
Mirror: Flip:
This function reverses the camera horizontally.
This function turns the camera upside down.
Enables the removal of Infrared Cutter
improve the image quality in the Night modus
This mode fixes the shutter speed
ADVANCE SETTING 1
PS SCAN ON STAB LE Z OO M ON DNR 00 BACK EXIT
ADVANCE SETTING 2
AE MODE AUTO
SHUTTER N/A IRIS N/A BRIGHT N/A
WB MODE AUTO
R GAIN N/A
B GAIN N /A HI-RESOLUTION OFF BACK EXIT
FUNCTION SETTING
PRESETS SCAN PATTERNS TOUR ZONES TIME RUNNING AUTO-TRACKING BACK EXIT
PRESETS
PRESET NUMBER 001 SET PRESET SHOW PRESET CLEAR PRESET AUTO-TRACKING ON EDIT PRESET LABEL BACK EXIT
ADVANCE SETTING 1
These function are o camera modules
PS SCAN:
on the WDR mode.
STABLE ZOOM:
using the Image Stabilizer function in accordance with the zoom ratio, and smoothly zooming up to approximately ×40 using a combination of the optical zoom and digital zoom.
DNR: D N R
Activate Progressive Scan, can be combine
Set the 2D/3D igital oise eduction.
nly available with the E-Serie
This function is performing correction
ADVANCE SETTING 2
Under the advanced setting, you can make improvements to image quality due to different environmental conditions.
AE MODE:
Auto Exposure mode. Depends on the light condition in the surveillance area, you can set the AE in different modes and adjust the parameters, such as shutter speed, iris factor and brightness for the best image quality.
WB MODE:
White balance mode, a image improvement based on DSP processing. you can also adjust the Red­Gain or Blue-Gain to change the color tone.
ALC, PLC:
Average and Peak Level Control, additional setting to WB function. only avialble with dedicated camera modules.
FUNCTION SETTING
In function setting menu, you can define and activate different PTZ funcitons, such as preset points, auto scan, tours and Pattern. Presets and tour functions can also be set or activated directly from keyboard device without OSD. Please refer to the keyboard’s manual for operation details.
PRESETS:
PRESET NUMBER:
G65-70 Series supports up to
128 presets. The number can be selected from 0 to
128.
SET PRESET:
Defining the preset points directly in OSD by entering this menu item and move the PTZ. press IRIS-OPEN key on the keyboard to save. If the preset is pointed within digital zoom, it will automatically go back to max. optical zoom range in order to provide the best image.
SHOW PRESET:
Moves to current preset point
Page 11
6.OSD - Patterns, Tours 6.OSD - Zones and Privacy Mask
CLEAR PRESET:
Clear the current preset
EDIT PRESET LABEL
AUTO-TRACKING:
LABEL
ROOM 1 BACK EXIT
SCAN
SCAN NUMBER 01 SCAN SPEED 63 SET LEFT LIMIT SET RIGHT LIMIT CLEAR SCAN RUN SCAN EDIT SCAN LABEL BACK EXIT
PATTERNS
PATTE RN NUMB ER 1 PROGRAM PATTERN RUN PATTERN CLEAR PATTERN EDIT PATTERN LABEL BACK EXIT
17
Some products may not be available in your country, please contact our distributor for more details
is called.
EDIT PRESET LABEL:
can define a name which will be shon on the operation screen once the preset is called. please choose the preset number at first. The avaialbe characters are: 0-9, A-Z, <,>,. and space.
SCAN
Th e SCAN f unc tion m ove s the P TZ bet wee n 2­predefined points in constant speed.The following parameters can be set:
SCAN NUMBER:
scan.
SCAN SPEED:
points.
SET LEFT LIMIT: SET RIGHT LIMIT: CLEAR SCAN: RUN SCAN: EDIT SCAN LABEL:
Pattern
Patte rn re cord s the u ser’s ope rat ion s teps o n pe rfor min g PTZ co ntr ol and s tor e s as a track . The Sp eed Do me ca n reco rd up t o 4 tra cks wi th ma x. 180 sec. each.
PATTERN NUMBER:
from 1 t o 4
PROGRAM PATTERN:
when selected. you can perfome PTZ movement for recording and shall not exceed 180 sec. Press IRIS­OPEN to save the track.
RUN PATTERN:
CLEAR PATTERN:
EDIT PATTERN L ABEL :
pattern.
Start Auto Tracking, if the preset
For th e curre nt preset, y ou
The Speed Dome
cruising speed between the
defines the left point.
de fine s the r ight p oin t
Delete the scan setting
starting the scan function
se t the na me fo r the sc an
Selects the pattern number,
Starts recording the pattern
Starts the current pattern
Delete curretn pattern.
Sets t he name f or current
supports up to 4
EDIT TOUR
TOUR DWELL 001 00-00-00-00-00-00-00-00 00-00-00-00-00-00-00-00 00-00-00-00-00-00-00-00 00-00-00-00-00-00-00-00 RUN TOUR BACK EXIT
ZONES
ZONE S NUMBE R 1 SET LEFT LIMIT SET RIGHT LIMIT CLEAR ZONE EDIT ZONE LABEL BACK EXIT
TIME RUNNING
DAY SUN
TIME CHANNEL 1 START TIME 0 0:00 END TIME 00:00
RUNNING NONE BACK EXIT
AUTO TRACKING
DAY SUN
STATE ON
START TIME 0 0:00
END TIME 00:00 SENSITIVE LOW TRACKING-ZOOM OFF SET LEFT LIMIT SET RIGHT LIMT BACK EXIT
Some products may not be available in your country, please contact our distributor for more details
Tour
Tour is an auto-run through selected preset po ints w ith d efin abl e paus e tim e . A tou r can store up to 32 presets points.
TOUR DWELL:
preset points. selectable between 000-255(s).
TOUR PRESETS:
ke ybo ard de vic e to ent er th e p res et po i nt selection. Move the joystick with up and down to se lect t he pr eset p oin ts by nu mbe r and sa ve th e setting with IRIS-OPEN key. with IRIS-CLOSE ke y you c an mo ve to t he pre vio u s sel ecti on. I f a se lect p oin t has th e va l ue 0, a ll the f oll owin g presets points will be ignored.
RU N TOU R:
menu.
pa use ti me fo r eve ry sto p on th e
pr ess IR IS- OPEN Key o n the
St arts t he to ur and e xit t he OSD
ZONE
You c an def ine t he zon es in t he who le PT r ang e up
up t o 8 zon es
to with individual label. When the display setting “Zone Label” is activated, the la bel wi ll be d ispl aye d on th e operati on sc reen . Th e defi nit ion of t he zo nes sh oul d not be overlapped.
ZONES NUMBER: SET LEFT LIMIT: SET RIGHT LIMIT: CLEAR ZONE: EDIT ZONE LABEL :
Current zone selection
Left limit of the current zone
Right limit of the current zone
Delet the current zone
change the laben of current zone.
TIME RUNNING
You c an set u p the t imer t o sta r t a fun cti o n lik e pr eset , tou r or pat ter n. Eac h day c an be se t 4 action.
AUTO TRACKING
Auto-Tracking can seach people or object with hi gh spe ed an d low li ght p erfo rma n ce.
DAY: set current day STATE : acti va t e AUTO-TR ACK ING on t his day STA RT TI ME: se t the t ime fo r act iva tion EN D TIME : set t he tim e for s top th e tra cki ng SE NSIT IVE : set th e sen siti vit y for th e det ecti on TRAKING ZOOM: activate auto-zoom SE T LIMI T: se t the ma x. an gle fo r the tracking.
18
Page 12
6.OSD - Alarm Setting
7. Dome Address & Protocol
WINDOW BLANKING
WINDOW NUMBER 01 EDIT WINDOW ENAB LE W INDOW O FF CLEAR WINDOW BACK EXIT
ALARMS
Resume OFF
SEQUENCE 001
RESET DELEY 030
ALARM CONTACT N/O
ALARM SETTING
ARM SETTING
BACK
EXIT
ALARM SETTING
ALARM NUMBER 001
ALARM
ACTION TOUR
ACTIVATE AUX AUX1
ALARM PRIORITY LOW
BACK
EXIT
ARM SETTING
DAY SUN
ARM STATE OFF ARM TIME N /A
UNARM TIME N/A BACK EXIT
Privacy Mask ( Window Blanking)
Privacy Mask is used to protect the privacy area not to be displayed once the camera is pointed on, such as ulevatory area or the operation desk of anATM machine. It might be required for video surveillance application depends on the local law regulation. The PTZ camera supports up to 24 private masks. ( depends on installed camera module, please contact your local sales representative for more information)
Hitachi camera modules
Sony Camera modules:
ex cep t the 45 s eri es pro vid es onl y 8)
LG,CNB Camera modules:
WINDOW NUMBER:
EDIT WINDOW:
the keyboard. presse IRIS-OPEN to save.
ENABLE WINDOW:
CLEAR WINDOW:
Edit position of the mask by joystick of
Delete the mask
: 8 ma ski n g are a.
up t o 24 ma s kin g area (
no masking function.
Mask number
shows the mask on screen OFF
Alarms
RESUME: Continue the function on the camera , if it
was setting before the alarms. RESET DELAY: How long the camera stay in Alarm
position.
ALARM CONTACT: Setting between N/C (normal Close) or N/O (normal Open).
ALARM NUMBER: curent Alarm number.
ALARM ACTION: Setting for PRESET, SCAN, TOUR,
PAT 1-4, or NONE, if the camere inAlarm position.
ACTIVATE AUX:
activate. Select between AUX1, AUX2 (not connected) or BOTH.
ALARM PRIORITY:
ARM SETTING: define the operation timer of the alarm
Setting Alarm Output, when Alarm is
define the priority of the alarm input.
Protocol setting
In order to establish a connection for telemetric control with keyboard device. you need to setup the dome address and protocol.
The PTZ cameras are capable with multiple communication protocol. The setting can be ch ange d thr ough t he DI P-S witc hes o n the re ar side of the connector boards as Illustrated.
Sw1 Sw2
SW 1:
represent the domes address in binary form.
please refer to the list on next page for reference.
SW 2:
Used for protocol settting and baud rate.
DIP 1 to 6 : Protocol setting DIP 7 and 8: Baud rate setting
Baud rate
DIP 7 DIP8
pl ease u se th e foll owi ng tab le fo r deta ils s e tup .
current pattern.
2400 bps 0 0
4800 bps 1 0
9600 bps 0 1
19200 bps 1 1
Protocol / DIP 1 2 3 4 5 6
B02 0 0 1 1 0 0
DIAMOND 1 0 0 1 0 0
HUNDA 1 0 1 1 0 0
KALATEL 0 1 0 1 0 0
LILIN 1 1 0 1 0 0
MOLYNX 0 0 1 0 0 0
PANASONIC 1 1 1 0 0 0
PELCO (D/P) 1 0 0 0 0 0
PHILIPS 0 0 0 0 0 1
SAE 0 1 0 0 0 0
SAMSUNG 0 0 0 1 0 0
SANTACHI 0 1 1 0 0 0
UNIVISION 0 1 0 0 0 1
VCL 1 1 0 0 0 0
19
Some products may not be available in your country, please contact our distributor for more details
VICON 1 0 1 0 0 0
AD 1 0 0 0 0 1
Page 13
7. Address ID, 1 to 67
7.Address ID, 68 to 135
Page 14
7. Address ID, 136 to 203
177
7. Address ID, 204 to 255
Page 15
8. Specification
9. Motion Tracking
Indoor 18X Indoor 18x
Model
Signal Format
Scanning
Image Sensor
H. Resolution
Viewing Angle
Zoom
Min. Illumination
Focus
White Balance
Shutter Speed
Iris Control
Gain Control
Video Output
S/N Ratio
PTZ Characteristics
On-Screen Display
OSD Menu
Object Tracking
(only G70AT serie)
Communication
Preset Positions
Auto Pan
Tour / Sequence
Alarm inputs
Operating Environment
Power
25
Some products may not be available in your country, please contact our distributor for more details
Outdoor 18X Outdoor 18x
Outdoor 18X Outdoor 18x
48.0° (Wide end) 54.2° (Wide end)
18× Opt. / 12× Digital 26× Opt. / 12× Digital
0.7 Lux
(1/50 sec., Color)
-
Auto / Manual (ATW, Indoor, Outdoor, One Push WB, Manual WB)
Wide Dynamic Function (SB18WD/ SB26WD / SB36WD models)
360° PAN (0.4° ~320° per sec) / 90° Tilt (0.4°~150° per sec) with
Auto Flip/ Vario-Speed control* / Proportional & constant PT speed
Date/ Time/ Zoom Rate/ Temperature/ Zones/ Camera name
Setup/ Automation programming/ Password protection
4 progr. Tours with max 32 presets/ 4 Pattern up to 180s
with WDR
1/4 inch Ex-View CCD
470 TVL, 440K Pixels (PAL)/ 540 TVL (High Resolution)
Day: 0.7Lx
(1/50), 0.1Lx (1/3)
Night: 0.01Lx (1/3)
1 to 1/10,000 Sec. 1/3 to 1/10,000 Sec.
Auto / Manua/ Auto Slow Shutter
Auto / Manual (-3 to 28 dB, 2 dB steps, 16steps)
VBS: 1.0Vp-p (Sync Negative), Y / C Output
Manual activation / Preset triggering / Scheduled activation
RS-485, , coax16 Multiple protocol supported
Outdoor: -40℃ to 60℃ / IP66 weather protection
Indoor: / humidity up to 95%-10 5℃to 0℃
Tracking zone selection
Yes, between 2 presets
7 inputs / 2 output
24V AC / 24W(indoor) 48W(outdoor)
Indoor 26x Indoor 36x
Outdoor 26x Outdoor 36x
Outdoor 26x Outdoor 36x
with WDR with WDR
AU-G65-SB26
Day / Night Day / NightDay / Night
PAL / NTSC
Progressive
2.2° (Tele end)
Day: 1.0 Lux (50IRE, F1.6)
Night: 0.01Lux
Auto / Manual
More than 50 dB
128 Presets
36× Opt. / 12× Digital
Night: 0.01Lx (1/3)
57.8° (Wide end)
1.7° (Tele end)2.8° (Tele end)
Day: 1.4Lx
(1/50), 0.1Lx (1/3)
Note: This option is only available if your Speed dome supported this function.
1. Enter the OSD menu with CALL 95
2. Go to the option Function Setting Auto Tracking
AUTO TRACKING
DAY SUN
STATE ON START TIME 0 0:00
END TIME 00:00 SENSITIVE LOW TRACKING-ZOOM OFF SET LEFT LIMIT SET RIGHT LIMT BACK EXIT
AUTO TRACKING
Auto-Tracking can seach people or object with hi gh spe ed an d low li ght p erfo rma nce.
DAY: set current day STATE : acti va t e AUTO-TR ACK ING on t his day START TIME: set the time for activation EN D TIME : set t he tim e for s top th e tra cki ng SE NSIT IVE : set th e sen siti vit y for th e det ecti on TRAKING ZOOM: activate auto-zoom SET LIMIT: set the max. angle for the tracking.
Setting 1: Auto Tracking all the time
1. Step: Set on all „Day“ (Mon-Sun) with „ON“ on the „State“ setting.
Setting 2: Auto Tracking on the certain time
1. Step: Set the desired „Day“ (Mon-Sun) with „ON“ on the „State“ setting.
2. Step: Set the „Start Time“ and „End Time“
Setting 3: Auto Tracking on the certain Area
1. Step: Set the desired „Day“ (Mon-Sun) with „ON“ on the „State“ setting. Set the „Time“, if it necessity.
2. Step: Set the „Left Limit“ and „Right Limit“
(The AT function will be stop, if the range of the limit is reach)
Optional function can be use:
.... Auto Zoom if the moving object is too small.
Tracking Zoom
: Go to
Start/Stop Auto Tracking by Preset
„Function Setting“ Preset“ and set „Auto Tracking“
→→„
ON....... Start Auto Tracking function
OFF...... Stop Auto Tracking function
NONE .. No function
..... Start a function if the AT isn‘t moving (lost object)
Park Time
Go to „System setting“ Motion“ and set the „Park Time“
time (1-240min) and action(like Preset as a Start position) to do, when the AT is on Idle.
Some products may not be available in your country, please contact our distributor for more details
26
Loading...