Read the following safety information carefully before attempting to operate or service the meter.
Use the meter only as specified in this manual; other wise, the protection provided by the meter may be
impaired.
zEnvironment conditions
① Altitude up to 2000 meters
② Relatively humidity 90% max.
③ Operation Ambient 0~40℃
z Maintenance & Clearing
① Repairs or servicing not covered in this manual should only be performed by qualified personnel.
② Periodically wipe the case with a dry cloth. Do not use abrasives or solvents on this instruments.
zSafety symbols Meter is protected throughout by double insulation or reinforced insulation.
When servicing, use only specified replacement parts.
Comply with EMC
II. General Description
Thank you for using our Sound Level Meter. To ensure that you can get the most from it, we recommend
that you read and follow the manual carefully before use.
This unit conforms to the IEC651 type 2, ANSI S1.4 type 2 for Sound Level Meters.
This Sound Level Meter has been designed to meet the measurement requirements of safety Engineers,
Health, Industrial safety offices and sound quality control in various environments.
z Ranges from 30dB to 130dB at frequencies between 31.5Hz and 8 KHz.
z Display with 0.1dB steps on a 4-digits LCD.
z With two equivalent weighted sound pressure levels, A and C.
III Specifications
Standard applied....................................................... IEC651 type 2, ANSI S1.4 type 2
Frequency range:....................................................................................31.5Hz~8KHz
If you operate at wind speed over 10m/sec, please put protective accessories in front of the microphone.
② Display
SYMBOL FUNCTION
LCD 4digits
MAX Maximum Value hold
OVER Over range
F Fast response
S Slow response
A A-Weighting
C C-Weighting
BAT
Lo Low Range (30~100dB)
Hi High Range (60~130dB)
BAT Low-Battery
③ Power ON/OFF button I
Turn the meter power ON/OFF
④ Backlight Button:
Turn the meter backlight ON/OFF
MAX Hold button MAX
The max. Hold position is used to measure the maximum level of sounds. The maximum
measured level is up dated continuously. Press once again the button, will release the hold and
allow a further measurement.
⑤ A-weighting / C-weighting select button A/C
A: A – Weighting. For general sound level measurements.
C: C – Weighting. For checking the low- frequency content of noise.
S
F
dB
(If the C-Weighted level is much higher than the A-Weighted level, then there is a large amount of
low-frequency noise)
⑥ Time weighting select button F/ S
F (fast response): for normal measurements (fast varying noise)
S (slow response): for checking average level of fluctuating noise
⑦ Level range select button Lo/Hi
Lo: 30~100dB; Hi: 60~130Db
When “OVER” is indicated, the ranges switch to another range for measurement.
⑧ MAX/ Hold button MAX/HOLD
The max. Hold position is used to measure the maximum level of sounds. The maxim um measured
level is up dated continuously. Press once again the button, will release the hold and allo w a further
measurement. Data Hold button: Press and hold the Button for over 2 second to turn on or off data
hold function. The hold function freezes the reading in the d isplay.
⑨ Microphone
1/2 inch Electret Condenser microphone
⑩ Battery Co ver
V. Measurement Preparation
(1) Battery loading
Remove the battery cover on the back and put in one 9V Battery.
(2) Battery Replacement
When the battery voltage drops below the operating voltage, mark “BAT” appears. If it appears,
battery should be replaced with new one.
VI. Operating Precautions
(1) Wind blowing across the microphone would bring additional extraneous noise.
Once using the instrument in the presence of wind, it is a must to mount the windscreen to not pick
up undesirable signals.
(2) To achieve more accurate measurement, use an extension cable to separate the Microphone from
the main body so that the effect of unexpected sound reflection can be eliminated.
(3) Calibrate the instrument before operation if the instrument was not in use for a long time or operated
at bad environment.
(4) Do not store or operate the instrument at high temperature and high humidity environment.
(5) Keep microphone dry and avoid severe vibration.
(6) Please take the battery and keep the instrument in low humidity environment. When not in use.
VII. Measurement
(1) Open battery cover and install a 9-volt battery in the battery compartment.
(2) Turn on power and select the desir ed respons e Time and weighting. If the sound source consists of
short bursts or only catching sound peak, set response to FAST. To measure average sound, use the
slow setting.
Select A- weighting for general noise sound level and C-weighting for measuring sound level of
acoustic material.
(3) Select desired Level
(4) Hold the instrument comfortably in hand or fix on tripod and point the mic rophone at the suspected
noise source, the sound pressure level will be displayed.
(5) When MAX (maximum hold) mode is chosen. The instrument captures and holds the maximum
noise level for a long period using any of the time weightings and ranges.
(6) When HOLD (data hold )mode is chosen.The hold function freezes the reading in the display. Press
the HOLD button momentarily to activate or to exit the HOLD function
(7) Turn OFF the instrument and remove and remove battery when not in use.
Veiligheid
Lees de volgende informatie eerst door alvorens de meter in bedrijf te stellen; gebruik de meter zoals hier
wordt weergegeven anders kunnen onjuiste metingen het gevolg zijn.
zMeet condities
① Hoogte tot 2000 meter
② Relative vochtigheidsgraad 90% max.
③ Omgevingstemperatuur 0~40°C
z Onderhoud
① Reparaties mogen alleen worden uitgevoerd door gekwalificeerd personeel.
② Gebruik geen chemische middelen om de meter te reinigen, maar een licht-vochtige doek..
zVeiligheids symbolen Meter is dubbel geisoleerd uitgevoerd.
Alleen originele onderdelen gebruiken ( ook in verband met de eigen veiligheid).
In overeenstemming met de EMC richtlijn uitgevoerd.
Beschrijving
Hartelijk dank voor de aanschaf van onze Decibel Meter. Lees de handleiding eerst door.
Deze meter is gefabriceerd volgens IEC651 type 2, ANSI S1.4 type 2 voor Sound Level Meters
en is ontworpen om tegemoet te komen aan de wensen van ingenieurs, welzijn – en veiligheids
medewerkers die zich vooral bezighouden met geluidskwaliteitscontroles en normen.
Specificaties
z Bereik tussen 30dB en 130dB bij frequenties tussen 31.5Hz en 8 KHz.
z Display met 0.1dB stappen in een 4-digits LCD.
z A / C geluidsdrukmeting ( voor 2 equivalenten)
Toegepaste Norm:.................................................... IEC651 type 2, ANSI S1.4 type 2