PHOTOELECTRIC SMOKE DETECTOR
Order ref: 350.125UN
User Manual
This unit detects initial smoke formation with its sensitive photoelectric system and signal processing
circuit giving an alarm signal as an early warning.
Operation:
1) Remove mounting plate from the back and insert the battery.
2) Press & hold the test button for a few seconds. When the alarm sounds release the button. The
alarm will sound 2 or 3 times to indicate it is in a working state.
3) Install the detector in a suitable place away from obstructions and with plenty of room for air flow,
eg; centre of a ceiling or roof.
4) When the battery needs replacing the alarm will sound approx. every 45 seconds
Please note:
• No user serviceable parts inside. The only replaceable part is the battery.
• Test the alarm weekly and every time the battery is replaced.
• Do not use in dusty and smoky environments.
• Keep out of reach of children.
• Any repairs should be carried out by qualified personnel.
• Please retain this manual for future reference.
Specification:
Battery 9Vdc (1 x PP3)
Alarm output 85dB/3m
Operation temperature -10°C - 40°C
Quiescent current 6-12µA
Dimensions 34 x 101mmØ
Weight 127g
07
1134
1134-CPD-032
EN14604
Photoelectric Smoke Alarm Device
350.125UN-001
Intended for Fire Safety and installed in buildings
Essential characteristic 1: Pass
Essential characteristic 2: Pass
Essential characteristic 3: Pass
Essential characteristic 4: Pass
Essential characteristic 5: Pass
Essential characteristic 6: Pass
Essential characteristic 7: Pass
Essential characteristic 8: Pass