000-009 White
010-019 Red
020-029 Green
030-039 Yellow
040-049 Blue
050-059 Pink
060-069 Orange
070-079 Purple
080-089 Magenta
090-099 UV
100-109 UV + White
CH 4
110-119 UV + Magenta
120-129 Magenta + Purple
130-139 Purple + Orange
140-149 Orange + Pink
150-159 Pink + Blue
160-169 Blue + Yellow
170-179 Yellow + Green
180-189 Green + Red
190-191 Red + White
192-223 Colour clockwise rotation (Fast - Slow)
224-255
Colour Anti clockwise rotation (Slow -
Fast)
CH 5 000-255 Pan Position
CH 6 000-255 Tilt Position
CH 7 000-255 Pan & Tilt Speed (fast to slow)
CH 8 255 Reset
150.443UK User Manual
DMX OPERATION:
DMX
Channel
CH 1
CH 2
CH 3
DMX
Value
Function Description
000 Blackout
001-255 Dimmer 0-100%
000-002 Shutter Open
This compact and lightweight mini moving head uses a powerful 30W white LED. It
has a 12° beam angle and features 9 gobos (plus spot) and 9 colour wheel (plus
white). It can be operated by 8 Channel DMX or one of the stage friendly internal
programs on either auto or sound to light mode. It can be free standing or mounted
to trussing using the supplied brackets. It is ideal for uses such as small stages, bars,
nightclubs, mobile DJs and bands.
• Manual focus adjustment to sharpen beams in smoke or the projected image
over a large distance.
• DMX in/out connections via 3-pin XLR
• Master and slave modes
• Strobe speed adjustable
• Stage friendly auto and sound activated modes
• Low noise fan
• Lightweight and easy to transport
• Pre fixed mounting bracket included
• We recommend that this product is used within the guidelines HSG95
150.443UK User Manual
150.443UK User Manual
PACKAGE CONTENTS:
Please check the contents to ensure that the product has been received in good
condition.
MHS-30 Moving head x 1pcs User’s Guide x 1pcs
Power Cord x 1pcs 1 x Mounting brackets
If you find any accessory is missing or the machine has arrived with any problems,
please contact your local dealer at once. Do not try to fix this item yourself or you
will lose the warranty. Please keep the original package and invoice for any possible
replacement or returned demand.
INSTALLATION:
Every person involved with the installation, operation and maintenance of this device
should be qualified and follow the instructions in this User Guide. We recommend
that this product is not used for audience scanning and should be used within the
guidelines of “HSG95”. When you connect to the main power supply the device will
take around 10 seconds before ready for use.
MOUNTING INSTRUCTIONS:
Attached the supplied mounting brackets to the underside of the fixture using the
supplied bolts. Fix a G-Clamp to the bracket securely ready for mounting. After
finding the desired position tighten the G-Clamp and use a safety wire for extra
security.
When selecting an installation location, take into consideration routine maintenance.
Safety cables must always be used. Never mount in places where the fixture will be
exposed to rain, high humidity, extreme temperatures changes or restricted
ventilation.
DISPLAY CONTROLS:
LED Display Action
Addr Set DMX Address
AUTO
AUTT
Sund
CH 1- 8
Er_L If displayed there is a brake in the DMX Chain.
PAn Reverse pan on/off
tiLt Reverse tilt on/off
REST Reset function
Aut1: For Floor operation, Pan is not restricted
Tilt movement is restricted to 210°.
Aut2: When using on the ceiling. Pan is not
restricted Tilt movement is restricted to 90°
forward 45°.
Aut3: DJ or Stage mode: X-axis restricted to
160° Tilt movement restricted to 90° (60° above
the horizon and 30° below).
Aut4: When using on the ceiling at the front of a
stage. Tile movement restricted to 160° Tilt
movement restricted to 90° (Vertically, front 75°
and back 15°)
Auto mode speed T000 (fast) – T099 (Slow)
Default is T007.
Sound to light mode (turns whatever auto mode
you have selected in to a sound activated
option).
Manual function based on DMX values for each
channel (See DMX operation).
150.443UK User Manual
150.443UK User Manual
REAR LAYOUT:
1. IEC Power IN and fuse holder
2. DMX IN
3. DMX OUT
CONTROL DISPLAY FOR:
CAUTION! TO PREVENT MORTAL ELECTRICAL RISK AND LONG LIFE OPERATION:
For your safety, please kindly pay attention to all of the warnings listed below:
Always plug in the power plug last and disconnect from the mains, when the
device is not in use or before cleaning.
Do not install and operate the device in rain or extreme heat, moisture or dusty
environments.
This device is for indoor use only and in a dry environment.
Do not switch on immediately but wait until it reaches to room temperature, if
the device has been exposed to drastic temperature fluctuations.
Do not shake the device and avoid brute force when installing or operating.
Do not spread the smoke or bubble of effect machine directly to the device.
Do not use the device during thunderstorms and please disconnect the power.
Do not use solvents or aggressive detergent to clean the device. Use a soft and
clean cloth.
Do not modify the device or the connected power cord without authorization.
Use appropriate safety-rope for safety.
Do not stare to the light.
1. MODE\ESC: Menu or withdraw the last menu
2. UP: Increase one step each time
3. DOWN: Decrease one set each time
4. ENTER: Confirms the functions you select
150.443UK User Manual
The symbol determines the minimum distance from lighted objects. The
minimum distance between light-output and the illuminated surface must be
more than 0.5m.
150.443UK User Manual
CONNECT WITH POWER SUPPLY – THE GROUND WIRE MUST BE CONNECTED:
Use the plug to connect to the main power supply as follows:
Wire Connection International signal
Brown Live L
Blue Neutral N
Yellow /Cyan Earth
QUICK TROUBLE SHOOTING
If the unit is not functioning properly follow the below guidelines
Check the IEC cable is fitted correctly.
Check the fuse hasn’t blown in both the IEC cable and unit (see below)
Check any DMX cables are connected correctly
Check the DMX address has been set correctly
If the unit still fails to respond then contact your retailer.
REPLACING FUSE
Disconnect from the main power supply first then remove the fuse holder above the
IEC Socket to reveal the fuse. Replace with the correct fuse rating as stated on the
product safety label. Then lock the fuse holder cover back into place.
GENERAL MAINTENANCE
To maintain optimum performance and minimize wear, fixtures should be cleaned
frequently. Usage and environment are contributing factors in determining frequency.
As a general rule, fixtures should be cleaned at least twice a month. Dust build-up
reduces light output performance and can cause overheating. This can lead to
reduced life and increased mechanical wear. Be sure to power off the fixture before
conducting maintenance.
Unplug fixture from the mains and use a vacuum or air compressor and a soft brush
to remove dust collected on external vents and internal components. Clean all glass
when fixture is cold with a mild solution to the cloth or tissue, and drag dirt and
grime to the outside of the lens. Gently polish optical surface until they free of haze
and lint.
The cleaning of external optical lenses must be carried out periodically to optimize
light output. Cleaning frequently depends on the environment in which the fixture
operates: damp, smoky or particularly dirty surroundings can require cleaning fluid.
Always dry the parts carefully. Clean the external optics at least every 20 days.