Avocent PM2000, PM3000 User Manual

PM2000 and PM3000 Intelligent Power Distribution Units
PM2000 & PM3000 intelligent Power Distribution units (IPDUs) support outlet level metering and switching capability to provide datacenter professionals the tools they need to monitor, measure, reduce, and manage their growing power consumption costs of IT equipment. Thresholds can be created to allow datacenter teams to know before problems occur and minimize downtime caused by overloaded circuits. With the ability to support up to 22 kW and support for C19 outlets, the PM2000 and PM3000 IPDUs are well positioned to support the high rack density found in organizations today.
Measure power at the Outlet level
Outlet level metering and switching capability provides datacenter professionals the tools they need to monitor, measure, reduce and chargeback their growing power consumption costs of IT equipment while minimizing any downtime that could potentially be caused by overloaded circuits or hung up IT equipment.
Metering/Switching capabilities
Capture valuable information and control power to individual devices
• Metering per outlet with the PM2000 IPDUs
• Metering and switching per outlet with PM3000 IPDUs
Alarms and monitoring
The Avocent PM2000 and PM3000 IPDUs deliver accurate, real-time current monitoring of all connected devices via the web manager, DSView® 3 software or locally through an LED digital display. Users can set a current alarm threshold that, once exceeded, will cause the PM PDU to sound an alarm or send a notifi cation message, or both.
Flexible management options
Avocent IPDUs can be combined with an ACS 6000 console server or DSR® KVM over IP switch to provide faster problem solving by integrating system access and power control in a single interface. Now you can see the remote devices and control their power using an integrated approach that allows you to actually see the remote device as it powers up or reboots. This integration provides instant feedback when critical issues are being resolved remotely.
DSView 3 management software integration
The DSView 3 software provides access and control to nearly all equipment found in today’s data centers. The DSView 3 Power Manager extends the capability of the DSView 3 software by also giving companies the ability to monitor and measure IT energy consumption, costs, and trends across all levels within their data centers and remote locations. With the PM2000 & PM3000 IPDUs this information can allow you to look at individual devices, a rack of equipment, a row of equipment and group items together to view overall consumptions, capacity and cost across many locations or just a single device.
Quick Facts
Measure and monitor power consumption per outlet Create thresholds and alerts Remote switching capability to power on/off outlets (PM3000 models) Designed to work with other Avocent products for an integrated solution Manage with DSView 3 Power Manager for historical reporting
Avocent can help you answer
questions like-
Do you know how much power each piece of equipment is consuming? Do you have the capability to cycle the power to your local and remote servers? How do you limit who has permission to power cycle equipment and how is that activity logged? When you install new equipment, how do you ensure that you have power available?
The PM2000 and PM3000 IPDUs (pictured) supply the power a data center needs.
Features and Benefi ts
 Outlet level, phase level, and strip level current/voltage/power metering with threshold/alert capabilities*.
Provides preemptive notifi cation of any impending overload issues before they occur, and simplifi es the
task of installing new equipment. *(Note- measurement resolution +/- %5)  Capability to remotely switch outlets through onboard web interface, DSView 3 management software (Not
available on PM2000).
Allows power to hung up IT equipment to be recycled, turned on or turned off remotely for faster resolution time.
On board web interface. Can be installed for direct access right out of the box or it can be confi gured
as part of a larger integrated solution using the DSView 3 software.  IP and Serial interface options. Options to install by connecting directly to the network or save IP connections by using the serial interface to connect directly to Avocent appliances already connected to the network.  Daisy chaining. Saves the number of IP addresses or console / KVM ports that are required to manage all power distribution needs.  Integration with DSView 3 software. Single interface for management of IT equipment and IPDUs simplifi es mapping of outlets to servers and other equipment to reduce and minimize power cycling the wrong equipment.  Integration with DSView 3 Power Manager. Track historical trends to measure and monitor IT power consumption, capacity, and cost to understand what issues exist and to make more informed decisions in the future.  Electronic Overcurrent Protection. Electronic Overcurrent Protection is an added layer of protection that is activated in the event of minor overloads. During such events, outlets are turned off fi rst instead of the primary overcurrent protection (OCP) tripping.  Sequential Startup. Protects integrity of all upstream electrical infrastructure by staggering the inrush current draw of all plugged in devices.  Internal temperature sensor and two optional external sensors. These sensors can measure environmental factors at several different points within the rack.
PM2000 Part Numbers
PM3000 Part Numbers Description
Ordering Details
North America
PM2001H-401 PM3001H-401 Horizontal 1-ph 24A 200-240V with L6-30, 3 C19 ports
PM2002H-401 PM3002H-401 Horizontal 3-ph 24A 200-240V with L15-30, 6 C19 ports
PM2005H-403 PM3005H-403 Horizontal 3-ph 40A 200-240V with Hubbell® CS8365C, 6 C19 ports
PM2005H-404 PM3005H-404 Horizontal 3-ph 48A 200-240V with IEC 309 60A, 6 C19 ports
PM2001V-401 PM3001V-401 Vertical 1-ph 24A 200-240V with L6-30, 21 C13 & 3 C19 ports
PM2002V-401 PM3002V-401 Vertical 3-ph 24A 200-240V with L15-30, 21 C13 & 3 C19 ports
PM2005V-403 PM3005V-403 Vertical 3-ph 40A 200-240V with Hubbell CS8365C, 21 C13 & 3 C19 ports
PM2005V-404 PM3005V-404 Vertical 3-ph 48A 200-240V with IEC 309 60A, 21 C13 & 3 C19 ports
Specifi cations
Mechanical
Size: 17 x 8.272 x 1.719 in (horizontal),
2.2 x 66 x 3.15 in (vertical) Weight: 7.3 lbs (horizontal without power cord), 14.8 lbs (vertical without power cord)
Environmental
Operating Temperature: 50 to 122 F (10
to 50 C) Storage Temperature: -40 to 149 F (-40 to 65 C)
Network Connection
Number: 1 Type: 10/100/1000 Ethernet
Accessories Included
Rackmount kit, toolless mounting hardware with vertical models and outlet retention clips
Standards
Approved Agency:
UL, FCC, cUL, CE, VCCI, C-Tick, CB
Warranty
Two Year
PM3000
Intelligent Power Distribution Unit
International
PM2003H-401 PM3003H-401 Horizontal 1-ph 32A 220/230/240V with IEC 309 32A, 3 C19 ports
PM2004H-401 PM3004H-401 Horizontal 3-ph 16A 380/400/415V with IEC 309 16A, 6 C19 ports
PM2005H-406 PM3005H-406 Horizontal 3-ph 32A 380/400/415V with IEC 309 32A, 6 C19 ports
PM2003V-401 PM3003V-401 Vertical 1-ph 32A 220/230/240V with IEC 309 32A, 21 C13 & 3 C19 ports
PM2004V-401 PM3004V-401 Vertical 3-ph 16A 380/400/415V with IEC 309 16A, 21 C13 & 3 C19 ports
PM2005V-406 PM3005V-406 Vertical 3-ph 32A 380/400/415V with IEC 309 32A, 21 C13 & 3 C19 ports
External Sensors
PMHD-THS Temperature, Humidity, Air Flow and dry contact combo sensor
PMHD-TS Temperature only sensor
Note: PM2000 models include per outlet metering capabilities PM3000 models include per outlet metering and switching capabilities
AMP values listed on the North American models are rated at 80% based on national electric codes.
Avocent, the Avocent logo, DSR and DSView are registered trademarks of Avocent Corporation or its affi liates in the U.S. and other countries. All other marks
ww w.avocent.com/contacts
are the property of their respective owners. Copyright © 2008. Avocent Corporation.