Avocent PM10-20A, PM10i-10A, PM10-L20A, PM10-L30A, PM10i-15A Specification Sheet

...
Cyclades PM
Intelligent Power Distribution Unit
IEC Models
Integrated Remote Power Management and Distribution for Use in Branch and Remote Offices
Cyclades® PM intelligent power distribution units (IPDUs) enable remote power control and system management of IT assets in branch and remote offices. When used in conjunction with Cyclades ACS advanced console servers and DSR® switch appliances, Cyclades PM IPDUs offer quick problem resolution through an integrated management interface. With one or more outlets positively associated with a particular device, users may control power “in line” through a user-defined “hot key” or by using an intuitive Web browser-based GUI. In addition, a special command set facilitates scripting.
Cyclades PM IPDUs — IEC Models
Cyclades PM IEC models are equipped with IEC320-C13 power outlets and either IEC320 modular inlets or fixed power cables. These units are available in 10A, 15A, 16A, 20A, 30A and 32A capacities. Each model includes two RS-232 ports: one for management and the second for daisy-chain expansion. Daisy chaining allows an operator to control up to 128 power outlets as a single device. Cyclades IEC IPDUs are designed to operate in 100-240 VAC environments.
An LED display shows the real time, true RMS current draw. Each PM unit may be configured to sound an alarm during an overcurrent condition, and if it is connected to a Cyclades ACS console server, the IPDU may also send notifications via e-mail messages, Short Message Service (SMS) pager messages and SNMP traps.
SView 3
D
Management Software
A
dmin
3
2
1
4
1
2
2
2
Applications
Power control over remote IT assets from
anywhere on earth
Seamless integration with Cyclades ACS
console servers, DSR switches and DSView
®
3 management software
Proactive fault management and isolation
Fault notifications via e-mail, SMS page
and SNMP traps
Benefits
Restore practically any IT asset without
dispatching service personnel
Virtually eliminate power control errors
during crisis situations
Improve administrative efficiency with
integrated control functions
Proactively identify and manage
problems to improve mean time between failure (MTBF)
Reduce risk, reduce mean time to repair
(MTTR)
Conserve valuable IP addresses and
switch ports
2
2
Cyclades OnSite
1
Branch Office Appliance IPDU Advanced Console Server Switch
2
2
Cyclades PM Cyclades ACS DSR
Data Center
3
Branch Office
4
Hardware Specifications – IEC
Interfaces: 2 RJ-45 RS-232 serial ports (9,600 8-N-1)
10 or 20 IEC 320-C13 outlets
Power:
PM10i-10A
100–240 VAC, 10 A, IEC 320-C14 inlet 10 A max. branch circuit rating 10 A max. per IEC 320-C13 outlet
PM10i-15A*
100–240 VAC, 15 A, IEC 320-C14 inlet 15 A max. branch circuit rating 10 A max. per IEC 320-C13 outlet
PM10i-16A
100–240 VAC, 16 A, IEC 320-C20 inlet 16 A max. branch circuit rating 10 A max. per IEC 320-C13 outlet
PM10i-20A,* PM20i-20A*
100–240 VAC, 20 A, IEC 320-C20 inlet 20 A max. branch circuit rating 10 A max. per IEC 320-C13 outlet
PM10i-L30A,* PM20i-L30A*
100–240 VAC, 30 A, NEMA L6-30P twist-lock plug 30 A max. branch circuit rating 10 A max. per IEC 320-C13 outlet
Operating Temperature: 50ºF to 122ºF (10ºC to 50ºC)
Storage Temperature: –40ºF to 185ºF (–40ºC to 85ºC)
Humidity: 5% to 95% noncondensing
Dimensions: (W x D x H) PM10i-10A, -15A, -16A, -20A
17 x 8 x 1.75 in. (43.18 x 20.32 x 4.45 cm)
PM10i-L30A, -32A, -32Au 17 x 12 x 1.75 in. (43.18 x 30.48 x 4.45 cm)
PM20i-16A, -20A, -L30A, -32A, -32Au 2 x 2.8 x 66 in. (5.08 x 7.11 x 167.64 cm)
Weight: PM10i 11.1 lb 5.0 kg
PM20i 14.1 lb 6.4 kg
Certifications: FCC Part 15, A CSA (fully compliant to UL standard)
EN55022, A (CE) EN60950† C-Tick
*Units are certified to 80% of max. current rating.
International models.
EN55024
PM10i-32A, PM20i-32A
100–240 VAC, 32 A, IEC 309 plug 32 A max. branch circuit rating 10 A max. per IEC 320-C13 outlet
PM10i-32Au, PM20i-32Au
100–240 VAC, 32 A, unterminated cable 32 A max. branch circuit rating 10 A max. per IEC 320-C13 outlet
PM20i-16A
100–240 VAC, 16 A, IEC 320-C20 inlet 16 A max. branch circuit rating 10 A max. per IEC 320-C13 outlet
Features
Connectivity
RS-232 serial port for configuration and management
Second RS-232 serial port for control-level daisy chaining
(up to 128 outlets)
Full RS-232 signal support allows dial-in access via modem
Administration
Name assignment per IPDU (up to 8 characters)
Name assignment per outlet (up to 16 characters)
Local authentication support (up to 8 users)
Per-outlet access control lists
Management
Independent control of power outlets (power on/off, cycle)
Virtual lock per outlet (on or off states)
Sequential power up with user-defined inter-outlet delays
Global, true RMS current monitoring per IPDU
Two-digit 7-segment LED current display
On/off status LED per outlet
User-defined overcurrent threshold with alarm
Built-in visual and audible alarms
Built-in ambient temperature sensor
Form Factors
Industry’s highest outlet density (up to 10 outlets per 1U)
Horizontal (1U) and vertical (0U) models address a wide variety
of applications
Integration Features*
Integrated power management through console and KVM sessions
CLI, menu and GUI interfaces
Multioutlet grouping for devices with redundant power supplies
RADIUS, TACACS+, Kerberos, LDAP, and Active Directory
server-based authentication with local fallback
Token-based strong authentication (RSA SecurID)
Event logging via syslog
Fault notification via e-mail, SMS page, SNMP trap
SNMP integration with enterprise systems
*Features available when product is used in conjunction with Cyclades ACS console servers, DSR switches, Cyclades OnSite branch office appliance or DSView 3 management software (not included).
Part Number Model Description
ATP3110 PM10i-10A 10 outlets, 10 A max. branch, IEC 320-C14 ATP3115-001 PM10i-15A 10 outlets, 15 A max. branch, IEC 320-C14 ATP3116 PM10i-16A 10 outlets, 16 A max. branch, IEC 320-C20 ATP3120-001 PM10i-20A 10 outlets, 20 A max. branch, IEC 320-C20 ATP3231-001 PM10i-L30A 10 outlets, 30 A max. branch, NEMA L6-30P ATP3230 PM10i-32A 10 outlets, 32 A max. branch, IEC 309 ATP3232 PM10i-32Au 10 outlets, 32 A max. branch, unterminated ATP2116 PM20i-16A 20 outlets, 16 A max. branch, IEC 320-C20 ATP2120-001 PM20i-20A 20 outlets, 20 A max. branch, IEC 320-C20 ATP3130-001 PM20i-L30A 20 outlets, 30 A max. branch, NEMA L6-30P ATP2132 PM20i-32A 20 outlets, 32 A max. branch, IEC 309 ATP2131 PM20i-32Au 20 outlets, 32 A max. branch, unterminated
CAB0055 PM10i, 10 A Power Cable 8 ft, IEC320-C13 to AS3112, AUS & NZ CAB0087 PM10i, 10 A Power Cable 8 ft, IEC320-C13 to CEE 7/7 Schuko, Continental EU CAB0088 PM10i, 10 A Power Cable 8 ft, IEC320-C13 to BS1363, UK & Ireland CAB0089 PM10i, 10 A Power Cable 8 ft, IEC320-C13 to NEMA 5-15P, USA CAB0191 PM10i, 15 A Power Cable 8 ft, IEC320-C13 to NEMA 6-15P, USA CAB0192 PM10i, PM20i, 16 A Power Cable 8 ft, IEC320-C19 to AS3112, AUS & NZ CAB0193 PM10i, PM20i, 16 A Power Cable 8 ft, IEC320-C19 to CEE 7/7 Schuko, Continental EU CAB0194 PM10i, PM20i, 16 A Power Cable 8 ft, IEC320-C19 to BS1363, UK & Ireland CAB0195 PM10i, PM20i, 20 A US Power Cable 8 ft, IEC320-C19 to NEMA 5-20P, USA CAB0197 PM10i, PM20i, 20 A US Power Cable 8 ft, IEC320-C19 to NEMA L6-20P, USA CAB0198 PM10i, PM20i, 20 A US Power Cable 8 ft, IEC320-C19 to NEMA L5-20P, USA
Corporate Headquarters 4991 Corporate Drive, Huntsville, AL 35805 TEL 866.277.1924 FAX 256.430.4030
www.avocent.com
IEC
Inputs
NEMA L6-30P
on fixed 8 ft power cord on fixed 8 ft power cord
Outlets
IEC 320-C13
Avocent, the Avocent logo, The Power of Being There, Cyclades, DSR and DSView are registered trademarks of Avocent Corporation or its affiliates. All other marks are the property of their respective owners.
Copyright © 2006. Avocent Corporation. All rights reserved.