Aviom F6 User Manual

DATA SHEET
ALLFRAME
Multi-Modular I/O System
F6
Modular I/O Frame
PRODUCT HIGHLIGHTS
Six slots for eld-swappable I/O cards•
Fits in standard NEMA Type 1 enclosures•
Flexible mounting options: on wall, in wall, • rack-mount, stage box
Power over Cat-5, or via XLR or Euroblock •
Designed for low-noise environments •
Easily congured using Pro64® Network • Manager™ software interface
The F6 is a modular I/O frame for the AllFrame Multi-Modular I/O
System™. Utilizing the F6 and digitizing the signals at the wall or floor connection panel eliminates the need for multiple large con­duit runs filled with analog wire, as well as the labor associated with dressing, terminating, and testing analog connections.
As part of the AllFrame Multi-Modular I/O System, the F6 can be integrated into a system in a number of ways. When housed in a standard NEMA Type 1 enclosure, along with other A/V and electri­cal services required for an installation, the F6 can be mounted on or in the wall, in standard 16”-centers studded walls, and dressed with custom plates as desired. (Minimum suggested backing box size: 12 x 14 x 4 in.) Using the optional RK6 Rack Kit, the F6 can also be mou nted front- or rear- faci ng in a st anda rd 19” rac k (6U r equired).
The SK6 Stage Kit may be used to provide added protection to
the F6 for on-stage use.
The F6 can be outfitted with up to six I/O cards, for a maximum of 24
in a nd 24 o ut. C ards are availab le fo r mic /lin e inputs, a nalo g outputs, and AES3 digital I/O. Cards can be configured by the user, allowing the F6 to adapt easily to a changing audio environment.
Connecting the F6 to the Pro64 network requires only an A-Net cable (Cat-5e/Cat-6 or fiber) and DC power (no power supply is included).
Power may be provided via the Cat-5 cable, using an approved Power Over A-Net (PoA) power supply such as the Aviom POA80, or on the Euroblock or four-pin XLR connector.
The F6 and its I/O cards are configured using the Pro64 Network
Manager™ control application and can be used in conjunction with
Aviom’s complete line of Pro64 audio networking products as well
as Pro16® Series personal mixers, output modules, and network devices. Mic preamp channels can be remote controlled from the software application, from a Pro64 RCI/MCS combination, or from
Yamaha® devices using m-control™.
Because Aviom’s Pro64 audio network offers unique advantages both in audio performance and in systemic flexibility, integrating the F6 into an installation is straightforward and free from compro­mise in audio fidelity. The Pro64 network supports any combination of parallel and serial connections without fidelity loss or directional limitations, so connection points can be placed wherever needed in a particular facility.
Technical SpecificaTionS
Channels Modular; 6 user congurable card slots;
Sample Rates 1x: 39.7–52kHz;
Routing and Control Via computer using Pro64 Network Manager
Computer Interface 1x USB; Type B connector
Max. Ambient Temp. 0˚C to 50˚C (32˚F to 122˚F)
A-Net
A-Net Cable Length
(no DC power)
Maximum simultaneously usable A-Net ports
maximum 24 channels of I/O
2x : 79. 4–10 4kH z
2 EtherCon® R J45 connectors; 2 SFP single- or multi-mode ber optic transceiver ports; (transceivers not included)
400 feet (120 meters) between devices (Cat-5e) multi- and single-mode ber distance perfor­mance varies with the transceivers
A maximum of t wo A-Net ports can be active at any time; Auto se nsing scans the Cat-5 copper and SFP ber ports at power up to determine which ports are to be made active; Any combination of Cat-5 and/or ber can be used.
Voice: +1 610.738.9005 • Fax: +1 610.738.9950 • www.Aviom.com
24-bit resolution
1157 Phoenixville Pike, Suite 201 • West Chester, PA 19380
Power Suppl y 30-60VDC, inclusive of tolerance
Power Over A-Net (PoA) Requirements
DC Power Require­ments for Euroblock and XLR Connectors
Backup Power 4-pin XLR; 30-60VDC
Cooling 3 ultra- quiet low-velo city fans
Dimensions 10.504 x 12.60 x 3.852 in. , 269.24 x 320.04 x 97.79 mm
Mini mum Back ing Box Dimensions
Weight 9 pounds (4.1 kg)
Power supplies are not included and must be supplied by the installer.
Requires POA80; a UL60950-1 Certied/Listed ITE power supply having a SELV (Safety Extra Low Voltage) rated output vol tage.
Requires a UL60950-1 Certied/Listed ITE power supply having a SELV (Safety Extra Low Voltage) rated output voltage b etween 30 and 60V D C.
To guarantee proper startup, this supply should be rated for at least 100 w atts.
Pin 1 Ground; Pin 2/3 no connect; Pin 4 24VDC; Euroblock; Pin 1: (+) 30-60VDC; Pin 2 (-) Ground
12 x 14 x 4 in., 30 4.8 x 355.6 x 101.6 mm
F6
1 2 3 4
C4m
1 2 3 4
C4o
1 2 3 4
C4o
1 2 3 4
C4o
ALLFRAME
A
B
C
D
E
F
Modular I/O Frame
F6
CONTROL MASTER
STANDBY
Modular I/O Frame
fronT panel feaTureS
Six I/O card slots, user congurable
Mic/line input, line-level output, or AES3 digital I/O cards (max. 24 in, 24 out)
Mounts in a standard NEMA Type 1 enclosure
LED indicators for A-Net, Power Status, Control Master, Clock Master, Thermal Monitor, and Error
USB interface, Control Master and Standby switches protected by removable cover plate
archiTecTural SpecificaTion
The Aviom F6 shall provide up to twenty-four channels of audio inputs and outputs transmitted digit ally via a Pro64® A-Ne t® network. It shall provide full- bandwidth, high-quality audio by emp loying the A- Net audio transmission protocol and shall support sample rates from 39.7kHz to 52kHz and 79.4kHz to 104kHz.
Digital and analog audio inputs and outputs shall be user-configurable and field -ser vicab le a nd s hall be provided i n th e fo rm o f si x ex pansi on s lots into which compat ible I/O cards c an be f itted .
Front-p anel features shall include LED indicators for A-Net Active, Power/Standby, Clock Master, Control Master, The rmal Monitor, and Error. On the top panel it shall
All Aviom prod ucts are designed and man ufactured in the USA.
On-Wall Installation (exploded view)
Top panel feaTureS
DC power via Euroblock, 4-pin XLR, or Cat-5e (approved external supply required)
Two locking EtherCon® RJ45 jacks
Two SFP ber optic transceiver ports
Supports single- or multi-mode ber
employ two EtherCon® RJ45 co nnecto rs and two SFP fib er optic tr ansceiver slo ts for the A-Net digital signal connections.
Al l pro gra mmin g an d ne two rk in ter fac e con tro l sha ll be pro vid ed vi a a co mpu ter­cont rolled sof tware interf ace.
The unit shall be powered via Cat-5e or from an external DC power supply (22-60VDC) with a Eu robloc k or four-pin XL R power connector. I t shall be U L liste d.
Its dimensions shall be 10.504 inches wide, 3.852 inch es deep, and 12.6 inches high. Its net weight shall be 9 pounds , and i ts f ront panel shall b e finished in black. The unit shall be Aviom In corporated model F6.
Aviom, A‑Net , the A‑Net ic on, Pro16, Pro6 4, Virtual Da ta Cable s, m‑contr ol, and AllFr ame are tra demarks o f Aviom, Inc. Al l other trad emarks a re the prop erty o f their respe ctive owne rs. ©2012 Aviom, Inc. A ll rights r eser ved. Inform ation subje ct to chan ge without n otice. rev. 1.3 072012
Loading...