TT-830 Bench Scale User’s Manual
EUROPEAN COUNTRIES
WARNING
This is a Class A product. In a domestic environment this product may cause radio
interference in which the user may be required to take adequate measures.
CAUTION
Risk of electrical shock. Do not remove cover. No user service­able parts inside. Refer servicing to qualified service personnel.
Weigh-Tronix reserves the right to change
06/05/03 830_U.P65 PN 29737-0017C e1 Printed in USA
2
TT-830 Bench Scale User’s Manual
Table of Contents
Table of Contents ..................................................................................... 3
Specifications............................................................................................ 4
Introduction ............................................................................................... 5
About This Manual .......................................................................... 5
TT-830 Bench Scale ................................................................................. 5
TT-830 Front Panel ......................................................................... 5
Weighing Operation ........................................................................ 8
Main Display ......................................................................... 6
Front Panel Keys .................................................................. 6
Hard Keys .................................................................. 6
Soft Keys ................................................................... 7
Pushbutton Tare Operation .................................................. 8
Keypad Tare Entry ............................................................... 8
Specialized Operations ................................................................... 9
Accessing Program Serial# ............................................................. 9
Pages are numbered consecutively beginning with the cover page.
TT-830 Bench Scale User’s Manual
3
Specifications
Power Input
Operational Keys
Operational Annunciators
Display
Display rate
A to D Conversion Rate
Unit of Measure
Capacity Selections
Incremental Selections
Displayed Resolution
Audio Output
115 Volts AC, 50/60 Hz single phase Optional 230 Volts AC, 50/60 Hz single phase
Zero, Tare, Print, Units, Select, Enter, Escape, Clear, 0-9, Decimal Point and Five Soft Keys labeled per selected operational routine.
Displayed symbols indicate motion, center of zero, unit of measure and more.
5" W x 1.33" H dot matrix LCD, cold cathode flourescent backlight (240 X 64 dot layout)
Selectable, 0.1 to maximum readable updates
60 times per second
Pounds, kilograms, grams, ounces, pounds and ounces and two selectable custom units
10 (5); 50 (25); 100 (50); lbs (kg)
Multiples and sub multiples of 1, 2, 5
NTEP pending at 10,000d / configurable
Audio tone for key contact assurance or operational alarms
Time and Date
Internal Resolution
Harmonizer™ digital filtering:
Standard input and outputs:
Available Options
Operating Temperatures
Dimensions
Weight
Agencies
Battery protected real time clock is standard
1,000,000 counts analog, QuartzellTM transducer = 2,000,000
Fully programmable to ignore noise and vibration
Four communications choices: Com 1: RS232, RS-485/422 Com 2: RS232, 20 mA current loop
(One bi-directional signal per port)
- DC operation at 10 to 32 VDC, 3.5 Amp
- OPTO 22 I/O Modules
- Remote Expanded Control Interface for 8, 16, 24, or 32 OPTO 22 I/O Mod­ules
- Alpha-numeric, PC style serial keyboard
14 to 104° F (-10 to 40° C), 10 to 90% relative humidity
Platform: 12" x 14" (50- and 100-lb models) Platform: 8.5" dia. (10-lb models) Overall: 14" W x 17" D x 4.5" H (35.6cm W x 43.2cm D x 11.4cm H)
18.5 lb, 8.4 kg
UL/CUL pending CE pending NTEP pending
Warranty
4
2 year
TT-830 Bench Scale User’s Manual
Introduction
About This Manual
TT-830 Bench Scale
TT-830 Front Panel
This manual covers the information you need to understand the operation of your Table Top 830 (TT-830) bench scale.
Major sections of this manual are headed by titles in a black bar like Intro- duction above. Subheadings appear in the left column. Instructions and text appear on the right side of the page. Occasionally notes, tips, and special instructions appear in the left column.
The TT-830 is a completely programmable table top scale with a Quartzell weight sensor. See the Specifications for a complete list of standard fea­tures.
The TT-830 front panel is shown in Figure 1.
TM
Figure 1
TT-830 Front Panel
The front panel includes the following:
• 240 x 64 dot matrix LCD display with cold cathode fluorescent back­light
• Five variable function soft keys
• Numeric keypad
• SELECT key
• UNITS key
• PRINT key
• TARE key
• ZERO key
• CLEAR key
• ESCAPE key
• ENTER key
• Decimal point key
TT-830 Bench Scale User’s Manual
5
Main Display
The main display is a 240 x 64 dot matrix LCD display with cold cathode fluorescent backlight. It can display graphics, words and numbers. This flexibility allows graphics and alphanumeric characters to be displayed at the same time. There are 33 displays available on the TT-830. See the Service Manual for all the examples. Your system will be configured for your particu­lar needs. The screen you see will depend on what weighing application you are performing.
Front Panel Keys
Hard Keys
The keys on the front panel of the TT-830 are of two types, hard keys and soft keys. Hard keys are labeled directly and soft key labels appear on the display. Soft keys (F1-F5) function differently at different times and their labels appear on the main display and they change as needed.
Below are brief descriptions for each of the hard key functions:
Repeatedly press the SELECT key to scroll through the available weight reading displays. (Examples - gross, net, tare, minimum, maximum, etc.)
Press the UNITS key to scroll through the available units of measure.
Press the PRINT key to send data to a connected printer.
Press the TARE key to enter a tare weight, then press SELECT to see the net display mode.
Press the ZERO key to establish a zero reference. A center-of-zero icon will be displayed. During motion an M will appear below the center-of-zero icon.
To increase the contrast of the display, press and hold the CLEAR and 9 keys until the desired contrast is reached. To decrease contrast, press and hold the CLEAR and 3 keys.
6
Press the ESCAPE key to back out of menus or cancel a numeric entry without accepting the value.
Press the CLEAR key to clear values from the display. See note at left.
Press the ENTER key to enter a keyed in value or accept a displayed choice.
Press and hold the ON/OFF key for five seconds to turn the unit off.
The numeric keypad is for entering numbers.
TT-830 Bench Scale User’s Manual
Soft Keys
Installing the TT-830
Soft keys are so-called because their function is not fixed. Function can change as mode of operations change or as the program for your particular setup changes.
Their are five soft keys located directly below the display. If the keys are needed during any operation, a label for each active key appears in the display directly above. There are only five key labels available at one time but this does not limit the potential usefulness of these keys. Programs can be created to enable one key to access another level of operation with five more key names and functions.
After unpacking the scale, place it on a level, stable surface. Plug it into an appropriate power source. The outlet must be properly grounded and readily accessible.
A new unit will power up ready to use. This scale is fully programmable. If you have a custom program resident in your unit, it will power up with that program active and ready to use.
Since custom programming is possible with this scale, the following pages only cover basic weighing procedures available when you receive a factory fresh scale.
To customize your unit you must write a program using the 830 SimPoser software available from Weigh-Tronix and download it to the scale.
TM
TT-830 Bench Scale User’s Manual
7
Weighing Operation
The following instructions step you through a typical weighing operation:
1. Power up the indicator. If the display mode is not the one you want to use, repeatedly press the SELECT key until the display value you want (gross, net, etc.) is displayed. . . Your indicator may be configured
with only one display value. Select­ing other display values may not be an option with your particular setup.
2. Zero the scale by pressing the ZERO key. . . Display should read zero weight and
the center of zero symbol is dis­played.
3. Place object to be weighed on the scale. . . An M appears on the display during
scale motion and the weight is displayed.
Pushbutton Tare Operation
Keypad Tare Entry
To perform a tare operation with the TARE key, follow these instructions:
1. Zero the scale by pressing the ZERO key. . . Display shows zero weight.
2. Place container to be tared on the scale and press the TARE key. . . The display changes to a NET
display and shows zero weight.
3. Place material to be weighed on the scale. . . Net weight is displayed.
For entry of a known tare weight follow these instructions:
1. With the indicator showing gross weight, key in the tare weight using the numeric keys. . . A tare entry display shows the
weight that you key in.
2. Press ENTER to accept this tare entry. . . The net weight is displayed in net
mode.
8
TT-830 Bench Scale User’s Manual
Specialized Operations
Due to the unlimited variety of applications available for the TT-830, it is not practical to describe all the possible specialized operations in this manual. Each application program will be unique.
Specialized operations will offer you soft key choices specific to the applica­tion and will guide you with messages on the display.
Accessing Program Information
The time may come when you are asked by a service technician for informa­tion about your software program. There is a series of key strokes which will bring that information to the screen. Below are the instructions:
1. Press and hold the ESCAPE key until the TT-830 beeps.
2. Within five seconds, key in the number 111 and press ENTER.
3. Press the soft key labeled VIEW.
4. Press the soft key labeled VERS. The information will appear on the display.
TT-830 Bench Scale User’s Manual
9
Declaration of Conformance to SMA Standard
Year of Declaration 2002
Production Meets Type
® *
We the manufacturer of
Model Type Certificate and Number Issued by
TT-830 Bench and Counter Scale NTEP CC 00-121A1 NCWM
Digital Electronic
Declare in our responsibility the conformance of the above listed models and types to the mentioned certificates and the requirements of the SMA standard.
This declaration becomes valid when the SMA Conformance Logo, having our name or trade­mark is applied to the device or its accompanying documentation.
* SMA PRODUCTION MEETS TYPE DEVICE MANUFACTURER Conformance Logo and Design are a registered
trademark of the Scale Manufacturers Association
Quartzell® is a registered trademark of Weigh-Tronix Inc.
Avery Weigh-Tronix
1000 Armstrong Dr. Fairmont, MN 56031 USA Telephone: 507-238-4461 Facsimile: 507-238-4195 e-mail: industrial@weigh-tronix.com www.wtxweb.com
Avery Weigh-Tronix Canada, ULC
217 Brunswick Boulevard Pointe Claire, QC H9R 4R7 Canada Telephone: 514-695-0380 Toll free: 800-561-9461 Facsimile: 514-695-6820 www.weigh-tronix.ca
Loading...