Avery Weigh-Tronix QC-3265 User Manual

Page 1
QC-3265 Checkweigher User ’s Manual
Page 2
Risk of electrical shock. Do not remove cover. No user service­able parts inside. Refer servicing to qualified service personnel.
10/05/01 3265_U.P65 PN 29600-0011J e1 Printed in USA
2
CAUTION
specifications at any time.
QC-3265 Checkweigher User’s Manual
Page 3
Table of Contents
Table of Contents..........................................................................................3
Specifications ................................................................................................4
Introduction ...................................................................................................7
Front Panel....................................................................................................7
Keys ...................................................................................................8
Annunciators ......................................................................................8
Installation and Operation ............................................................................. 9
Installation ..........................................................................................9
Explanation of Modes of Operation ....................................................9
Operation as a Scale..........................................................................9
Gross Weight Checkweighing ..........................................................10
Net Weight Checkweighing .............................................................. 1 0
Changing the Acceptance Tolerance ...............................................11
User Menu...................................................................................................11
Communication ...........................................................................................13
Error Displays..............................................................................................13
Plastic Knob Installation for USDA Approved Applications .........................14
Pages are numbered consecutively beginning with the cover page.
QC-3265 Checkweigher User’s Manual
3
Page 4
Specifications
Display
Light Emitting Diodes
A/D Conversion Rate
Internal Resolution
Excitation for Load Cells
Power Requirements
Battery Information
Accuracy
7 segment LCD, 6 digits, 0.7 inch high with 5 decimal points 7 segment LED, 6 digits, 0.6 inch high with 5 decimal points
8 LEDs for the following functions:
OVER - yellow ACCEPT - green UNDER - red lb - red kg - red oz - red g - red
Center of Zero - green
60 Hz. Delta-Sigma type converter 4,718,592 counts per mV/V per second Voltage : 6 volts DC (LCD), 10 volts DC (LED)
Available Current: 69 mA (four 350 ohm load cells) LCD
114 mA (four 350 ohm load cells) LED
*115 VAC +10% to -15% @ 0.10 Amp maximum 230 VAC +10% to -15% @ 0.05 Amp maximum 12 VDC (10 to 15 volts) @ 80 mA with 1 load cell
@ 131 mA with 4 load cells
Available for LCD version only. 30 Hour battery life. 14 hour recharge time. Low battery warning. Low power shutoff.
Handbook 44 for 6,000 divisions (-10 to 40°C)
Charging can occur during AC operation.
LCD only
Linearity
Repeatability
Hystersis
Calibration and Programming
Display Rates
Filtering
Push Button Zero Range
Motion Detection Window
Automatic Zero Tracking
-10 to 40°C -30 to 60°C
Zero: ±.085 µV/°C ±0.17 µV/°C Span: ±5.0 ppm/°C ±10 ppm/°C
(For scale base, 3000 divisions) ±0.005% of capacity, maximum (For base, ±0.01%) ±0.005% of capacity, maximum (For base, ±0.01%)
0.005% of capacity, maximum (For base, 0.01%) All calibration and programming is done through the front panel with data
stored in nonvolatile memory. 1, 2, 5, or 10* times per second 1*, 2, 5, or 10 display intervals ±1%, ±2%, ±5%, ±10%, ±20%, ±50%, ±100%* of Capacity d = 1 displayed division
±0.25 d, ±0.5 d, ±0.6 d, ±1 d*, ±2 d, ±3 d, ±5 d d = 1 displayed division
Window: ±0.25 d, ±0.5 d, ±0.6 d*, ±1 d, ±2 d, ±3, ±5 d, Rate: 0.1 division per second Starting Delay: 2 seconds
Over Range Capacity
4
The scale displays weights up to capacity plus 9 divisions, referenced from the zero value determined by zero setting point, or 105% of capacity, referenced from the deadload.
* = default
QC-3265 Checkweigher User’s Manual
Page 5
Under Range Capacity
The scale displays weights in the negative direction using the same restric­tions as for over-range, but further limited by the number of display digits available.
Temperature Range
Humidity
Scale Capacity and Division
-10 to 40°C (14 to 104°F)
-30 to 60°C (-22 to 140°F) with reduced accuracy Up to 100% relative humidity.
Pounds Ounces Kilograms Grams
6 x .002 100 x .05 3 x .001 3000 x 1 6 x .001 100 x .02 3 x .0005 3000 x .5
*12 x .005 200 x 0.1 6 x .002 6000 x 2
12 x .002 200 x 0.05 6 x .001 6000 x 1 30 x .01 480 x 0.2 15 x .005 15000 x 5 30 x .005 480 x 0.1 15 x .002 15000 x 2 60 x .02 960 x 0.5 30 x .01 30000 x 10
60 x .01 960 x 0.2 30 x .005 30000 x 5 100 x .05 1600 x 0.5 45 x .02 45000 x 20 100 x .02 1600 x 0.2 45 x .01 45000 x 10 200 x .1 3200 x 1 90 x .05 90000 x 50 200 x .05 3200 x .5 90 x .02 90000 x 20
* = default
Options
• LCD & LED versions
• 230 VAC 50/60 Hz power
• Tower mounted toggle switch for setting target weight and zeroing
• Battery and charger (available with LCD version only)
• RS-232 or RS-485 interface board
• Short and extended towers
• Remote head
• NTEP load cells
QC-3265 Checkweigher User’s Manual
5
Page 6
This page left intentionally blank.
6
QC-3265 Checkweigher User’s Manual
Page 7
Introduction
This manual covers software 48307-0025B and newer on the LED model of the QC­3265 and 48307-0017C and newer on the LCD model. These revisions contain the LB-OZ capability which previous versions did not have.
Front Panel
The Quick Check QC-3265 Checkweigher is a low-cost, high-speed produc­tion checkweigher housed in stainless steel for harsh, washdown environ­ments. This manual is divided into the following sections:
• Introduction
• Front Panel
• Operation
• User Menu
If you have any problems with your QC-3265 Checkweigher, call your local Weigh-Tronix distributor.
Figure 1 shows the front panel. The panel consists of the following:
• a six-digit, liquid crystal or LED display
• five keys; QUICK CHECK
TARGET
UNITS
ZERO
(Right arrow key)
• a center of zero annunciator
• four unit of measure annunciators; lb, kg, oz, g
• three checkweigher annunciators; OVER, ACCEPT, UNDER
Figure 1
QC-3265 Front Panel
QC-3265 Checkweigher User’s Manual
7
Page 8
Keys
If for some reason the QC­3265 cannot perform a key function (due to motion, range limits, and others) the display will show CAN'T while the key is held down.
Following are the keys and their functions.
Press this key to toggle between checkweigh mode and weight display mode, assuming you have an active target weight. Use the QUICK CHECK key to return to the weight display and checkweigh modes from anywhere in the menus. Press this key to accept a displayed selection and return to a display mode.
Use the up arrow-TARGET key to set the target weight. With no weight on the scale, press this key to remove a target weight and enter the weight display mode. With a weight on the scale, press this key set the target weight and to enter the Checkweigh mode from the weight display mode. Also, press this key to move up in the menus. You can also set the target weight by flipping the optional, column mounted toggle switch up.
Use the left arrow-UNITS key to change the unit of measure in weight display mode and checkweigh mode. This key works only if more than one unit of measure is enabled. Use this key to move to the left in the menus.
Key names are abbreviated in many of the instructions of this manual. Instead of saying the up arrow-TARGET key every time it is shortened to this symbol ^.
^ = up arrow key v = down arrow key < = left arrow key > = right arrow key
Annunciators
Use the ZERO-down arrow key to zero the scale while in either display mode. In the A/D test mode this key sets the offset to zero. Use this key to move down in the menu hierarchy. With a selection displayed, press this key to select that item and go up one menu level. You can also zero the scale by flipping the optional, column mounted toggle switch down.
Use the right arrow key to move to the right in the menus.
The OVER, ACCEPT, and UNDER annunciators are to the right of the display and are shown below. The OVER light is yellow, the ACCEPT light is green and the UNDER light is red.
Target weight and the toler­ances are saved in nonvolatile memory. They are not lost when the unit is powered down.
8
QC-3265 Checkweigher User’s Manual
Page 9
The unit of measure annunciators are below the display and are reproduced
The lb and oz annunciators will be lit when you are in the LB­OZ unit of measure. Two numbers are displayed sepa­rated by a space in LB-OZ. The left number is the number of pounds and the right is the ounces to the correct division size.
below. The lit annunciator tells you the currently selected unit of measure­ment.
The center of zero annunciator, reproduced below, is next to the ZERO key. When the annunciator is lit the scale is within ¼ division of zero.
Installation and Operation
Installation
There is no ON/OFF switch. When the unit is plugged in it will power up. If the battery option is installed and enabled, press any key to start.
Explanation of Modes of Operation
Place the QC-3265 on a stable, level surface. Use the leveling feet to level the scale. A bubble level is visible under the
scale platform shroud. Lock the feet in this position using the locknuts on the feet.
Plug the unit into a properly grounded 115VAC outlet.
The socket-outlet must be installed near
the equipment and easily accessible.
There are two modes of operation for the QC-3265, the weight display mode and the checkweigh mode.
• Use the weight display mode when you want to use the scale for displaying weight. The scale powers up in weight display mode if there is no target weight in memory.
• Use the checkweigh mode for checkweighing operations and the use of the OVER, ACCEPT, and UNDER LEDs. If there is a target weight in memory, the scale will power up in the checkweigh mode. Below are explanations of the operation in each mode.
Operation as a Scale
Press the UNITS key to view a weight in a different unit of measure.
With the scale in weight display mode, follow these steps to perform a weighment:
1. Press the ZERO key to zero the scale. . . Display shows 0 weight.
2. Place the object to be weighed on the scale. . . The weight is displayed.
QC-3265 Checkweigher User’s Manual
9
Page 10
Gross Weight Checkweighing
To use the QC-3265 as a checkweigher for gross weight, follow the direc­tions given below:
1. Zero the scale by pressing the ZERO key or flip the optional toggle switch down. . . Display shows 0 weight.
In gross mode, the indicator will always represent negative weight with a leading minus sign. If the weight becomes too large, positive or negative, overscores or underscores will be displayed while the condi­tion persists.
Changing the Acceptance Tolerance
Over and Under tolerance can be set from the User menu or the Setup menu (see Service Manual) but not both. The choice where the tolerances appear is made in the Setup menu. The tolerances will not appear in the User menu if they appear in the Setup menu and vice versa.
2. Place a test weight on the scale equal to the gross weight of the package. . . The gross weight is displayed.
3. Press the TARGET key or flip the optional toggle switch up. . . The display shows 0 weight and the
ACCEPT LED illuminates.
4. Remove the test weight and place a package on the scale. . . The display will show the weight
deviation from the target weight and the OVER, ACCEPT, or UNDER LED will illuminate accordingly.
IMPORTANT NOTE: If you use the ZERO key to tare a container weight and use the checkweigher in net weighing mode, the unit will track zero whenever there is an empty container on the scale. If the scale is left idle while empty, zero drift may occur.
1. Press the > key. . . OVER is displayed.
2. Press the v key. .. o 0.5 is an example of what might
be displayed. o stands for over tolerance and the value is the current over tolerance. The actual value depends on the unit of mea­sure and division size. The over LED is lit.
3. Press the < key to decrease the value and the > key to increase the tolerance value. Press the v key to accept the displayed value. OVER is displayed.
If you change the tolerance but decide you would rather keep the original value, press the ^ key in step 2 to return to OVER without accepting the displayed value.
Target weight and the toler­ances are saved in nonvolatile memory. They are not lost when the unit is powered down.
10
4. Press the > key. . . UNDER is displayed.
5. Press the v key. . . u 0.5 is an example of what might
6. Repeat step 3 and press the
be displayed. u stands for under tolerance and the value is the current under tolerance. The under LED is lit.
QUICK CHECK key to return to the checkweigh or display mode.
QC-3265 Checkweigher User’s Manual
Page 11
User Menu
Move to the right by pressing the > key Move down by pressing the v key Move left by pressing the < key Move up by pressing the ^ key.
Without realizing it you have learned how to access the User menu. When you press the > key from either the checkweighing (deviation display) or the weighing (weight display) mode you access the User menu shown below.
Figure 2
User Menu
You have already learned about UNDER and OVER tolerance. The other items in this menu are described below.
OFF This item appears only if battery power mode is enabled in setup,
With OFF displayed, press the v key to turn off the QC-3265. Pressing any key turns the unit on in weight display mode. Battery power is not an option with QC-3265s equipped with an LED weight display.
ABOUT Press the v key with ABOUT displayed and QC3265 will be
displayed. Press the > key to step through the EPROM part number, dash number, revision letter, and then back to QC3265. Press the ^ key to go back to the ABOUT display.
TEST Press the v key with TEST displayed to access the test menu
shown in Figure 3. Use the v, ^, <, and > keys as before to move through the menu.
AUDIT Lets you see the CA (calibration) audit number and the
CF (configuration) audit number.
DISP. Press the v key twice to perform a display segment
test. Press the < or > key to change the direction of the test. Press the ^ key twice to stop the test and return to DISP.
QC-3265 Checkweigher User’s Manual
11
Page 12
BUTTON Lets you check the function of each key. Figure 3
shows you what will be displayed as you press each key.
VOLTS Shows you the current input voltage going into the
voltage regulator.
A to D Shows the output of the A to D converter with a
sensitivity of 20,000 counts per millivolt per volt.
SERIAL Lets you perform READY/BUSY and LOOP/NOLOOP
tests to check the serial port. READY/BUSY not available unless RS-232 has been selected during setup.
SETUP This is a password protected menu and is used for basic setup
and configuration of the unit. See the Service Manual for details.
12
Figure 3
Test Menu
QC-3265 Checkweigher User’s Manual
Page 13
Communication
Error Displays
The QC-3265 has an optional RS-232 or RS-485 communication capability. Your unit may be customized to print according to your needs. Examples of the default print layout are shown below:
30.01 lb G or 0.01 kg DEV
What is transmitted is the weight or deviation, one space, the unit of mea­sure, one space, and a label for the weight (G for gross, DEV for deviation).
Your unit may be set up to send data continuously, after each weighment (if a 30 division movement has occurred), or upon request from a computer.
The following are displays you may see if problems occur or if invalid operations are attempted with your QC-3265:
Display Description
Overrange weight.
Underrange weight.
Recovering from lock-up or out of range condition.
A-D converter is not functioning.
A-D converter subjected to an input signal beyond ±6.66667 mV/V
The unit cannot perform a function. Displayed only while key is held down.
Corrupted data in the reset menus. See Reset Menus. (* = RESET, SETUP, or CAL)
A low input voltage is detected. This appears when voltage level reaches 10.5 volts and alternates with the normal display. The unit will shut itself off at 9.2 volts. Only available on battery powered units.
QC-3265 Checkweigher User’s Manual
13
Page 14
Low voltage on the LED version.
Displayed while a key is pressed when attempting to modify a sealed selection without edit privileges.
Scale unstable at power up.
Serial port handshake not responding.
Plastic Knob Installation for USDA Approved Applications
Below are the instructions and illustration for installing the plastic knobs which are necessary for USDA approved installations.
Install knobs by
• Removing the two 10-32 hexhead screws accompanying the unit.
• Replace with knobs.
• Use supplied Belleville washers between knob and mounting surface.
• Install the washer with the major diameter bearing against mounting
surface.
14
Figure 4
Plastic knob installation
QC-3265 Checkweigher User’s Manual
Page 15
Weigh-Tronix
1000 Armstrong Dr. Fairmont, MN 56031 USA Telephone: 507-238-4461 Facsimile: 507-238-4195 e-mail: industrial@weigh-tronix.com www.wtxweb.com
Weigh-Tronix Canada, ULC
217 Brunswick Blvd. Pointe Claire, QC H9R 4R7 Canada Telephone: 514-695-0380 Facsimile: 514-695-6820
Weigh Bar® is a registered trademark of Weigh-Tronix Inc.
Weighing Products & Systems
Loading...