avertX C6012-RW Quick Start Manual

Please carefully read these instructions before using this product.
Save this document for future use.
C6012-RW
Indoor Drop Ceiling
Camera
Quick Start Guide
1. General Specications
Model No. C6012-RW
IP Rating N/A (Indoor)
Wide Dynamic Range Spectrum Vision True WDR
Minimum Illumination @ 50 IRE Color: 4.0 Lux @ F 1.6
B / W: 0.8 Lux @ F 1.6
0 Lux w / R LED ON
Minimum Illumination @ 30 IRE Color: 2.4 Lux @ F1.6
B / W: 0.8 Lux @ F 1.6
0 Lux w / R LED ON
Day / Night True Day / Night
Resolution 1080p (2 MP)
Focal Length
4 mm (86° FoV)
Iris Control F 2.0 Fixed
White Balance Auto, Manual, Preset
Auto White Balance Range 2000K ~ 11000K
Backlight Compensation Yes
Auto Gain Control Yes
Operating Temperature 14°F (-10°C) ~ 122°F (50°C)
Power Consumption 5W Max
Rated Amperage 0.41A
Imput Voltage Power over Ethernet / 12vDC
Weight 0.5 lb (221 g)
Dimensions (W x H) 3.56” x 4.5” (90.5 mm x 114 mm)
Housing / Dome Cover White / Clear
2. Products and Accessories
Dome Cover
Audio, Alarm Cable
Power Cable
Screw & Plastic Anchor - 2pcs
Template Sheet
Quick Start Guide
Deco Rings
(white & black)
Camera
A - Lens B - Tilt Stopper Screw C - Magnetic Plate D - Body E - Flush Mounting Bracket
3. Product Overview
Before installing your camera, read the following precautions:
1. Determine if the site of installation can bear a minimum of five times the camera weight.
2. Ensure that all cable runs are secure and meet local fire codes.
3. When installing your camera, be sure the installation site is clear of unnecessary personnel and debris.
To access the restart button, detach the
body from the flush mount bracket.
1. Turn the body counter-clockwise and pull.
4. Before Installation
Reset Button
50°360° 86°
A
B
C
C
C
D
E
Warning:
If you press the Reset button, you will lose all settings.
Reset to Factory Default:
Press the Reset button for 5 seconds to return the setup to the factory default.
Save this document for future use.
5. Installation Using Tension Hooks
4
Connect the cables to the camera. See ‘6. Cabling.’
5
After inserting the body into the ush mount bracket, turn the body clockwise to secure the body in the ush mount bracket.
1
Disassemble the camera. See ‘4. Before Installation.’
2
Using the template sheet provided, make a hole for the ush
mount bracket in the ceiling.
3
Pull the cable through the hole in the ceiling and through the
ush mount bracket.
2
3
4
6
Slide the upper dome onto the camera and the magnets will
connect to the ush mount bracket, securing the upper dome.
7
6. Cabling
This camera is compatible with 12vDC and Power over Ethernet (PoE). Connect power to the camera using the provided power connector lead or connect the camera to a PoE power source. If you are connecting 12vDC power, verify the polarity of the power connection. If you are using PoE, make sure the Power Sourcing Equipment (PSE) is in use in the network.
PoE Power Source:
PoE allows for the transmission of power and date via a single Ethernet cable. PoE eliminates the need for multiple cables to support power and recording. Follow the installation below to connect the camera to a PoE-enabled switch using an Ethernet cable.
12vDC Power:
If PoE is not being used, a power adapter is needed for power transmission. Follow the instructions below to connect the camera without a PoE cable.
RESET
NETWORK
PoE
DC12V
+
-
Micro SD
+
+
-
-
ALARM OUT
ALARM OUT
ALARM IN
ALARM IN
GND
GND
AUDIO OUT
AUDIO IN
7. Connecting to the IP
Camera
To access the camera setup menu, you need to install the AvertX Network Camera Manager on your PC or recorder. To install the AvertX Network Camera Manager application on your PC, download the program from AvertX.com/downloads, and follow the prompts.
1. Open Network Camera Manager, and click Find Devices.
2. Locate your camera on the Network Camera Manager list.
3. To open the viewer software in your web browser, double-click the camera, and then click Browse.
The rst time you connect to the camera you will automatically be
prompted to install the ActiveX controller. If you internet browser doesn’t install the viewer software, check the security settings or Ac­tiveX controls and plug-in settings. If your internet browser asks for permission to install the ActiveX control, you must allow the ActiveX control to continue the installation.
8. Assigning an IP Address
AvertX IP cameras are set to get an IP address automatically using DHCP. If a DHCP server like a router is not part of your network, all cameras will have the default IP address 192.168.0.250.
AvertX recommends changing the IP address even if a DHCP server has assigned the camera an address.
Network cable
Network cable
Using a screwdriver, push the tension hook upward, then to the
side. This will create tension against the ush mount bracket to
hold it in place.
7
To enable installation of ActiveX controls on Internet Explorer:
1. From the Tools menu, click Internet Options.
2. Click the Security tab and then click the Internet icon.
3. Click Custom Level and ensure that all ActiveX controls and plug- ins are set to Enable or Prompt.
To ad the camera to your trusted sites:
1. From the Tools menu, click Internet Options.
2. Click the Security tab and then click Trusted Sites icon.
3. Click Sites.
4. Type the IP Address of the camera. Ensure that the Require server verication check box is cleared.
For additional information on adjusting the settings of your internet browser, contact your system administrator or refer to the FAQs at AvertX.net.
Default Username and Password
The username and password are case sensitive. It is strongly recom­mended that the password be changed after the initial setup to prevent unauthorized access.
Username - admin
Password - 1234
6
5
12vDC power
Loading...