Please take a few minutes to read through the ENTIRE INSTRUCTION LEAFLET before you use your ISIS iQ UNO for the first time. PLEASE SAVE THESE INSTRUCTIONS.
Unless advised otherwise by your health professional it is best to wait until your breastfeeding routine is established before expressing – usually after around four weeks.
Contents
PAG E ISIS iQ UNO parts 2–3 Important safeguards 4 How to clean and sterilise your ISIS iQ UNO 5–6 How to assemble your ISIS iQ UNO 7–8 How to use your ISIS iQ UNO 9–12 Hints to help you succeed 14 Using your ISIS iQ UNO as a manual breast pump 15–16 Storing your expressed breast milk 17 Key to product label and Guarantee 18 Troubleshooting guide 19–20
If you experience any problems or need any help with this product, please contact AVENT Customer Services (see back cover for contact details). Our representatives will be happy to assist you
.
We’ve taken everything women loved about our classic ISIS™ manual breast pump – the soft petal massager and fingertip sensitive control that make it feel so gentle, natural and comfortable – and we’ve given it an iQ – an electronic memory.
ISIS iQ learns from you. Begin by pumping manually, then touch the button and let ISIS iQ quietly continue your exact pumping rhythm.
If at any time you want to vary the rhythm, touch the button again to revert to manual. ISIS iQ is totally responsive to your needs.
Relax and enjoy the experience because you’re always in complete control. And when you’re relaxed and comfortable, you express more milk, faster.
1x Control handle 1x Silicone diaphragm with stem 1x White Valve 1x Pump body 2x Reusable bases (1x 125ml/4oz and 1x 260ml/9oz) 1x Stand (same as ) 1x Let-down Massage Cushion™
Bottle parts
ISIS iQ UNO™ parts
d
e
f
g
h
k
l
n
o
h
j
a
c
Pump parts
i
m
1x Funnel cover (same as ) 1x Battery pack 1x Wall plug lead 1x Dome cap 1x Newborn Teat (0m+) 2x Screw rings 1x Travel cover 2x Sealing discs
f
h
i
j
k
l
m
n
o
b
Main parts in detail
NEVER STERILISE OR IMMERSE IN WATER!
Control handle
NEVER STERILISE OR IMMERSE IN WATER!
Battery pack
3
Control button
Light
Power cable
Only the following batteries are compatible with the ISIS iQ UNO™ Battery Pack: Duracell Ultra M3, Duracell Plus, Energiser Ultra Plus, Duracell Accu (NiMH), Ansmann (NiMH). For Duracell Acc (NiMH) & Ansmann (NiMH) use / charge in accordance with manufacturers guidelines. Dispose of batteries as per manufacturers instructions.
Power socket
Control handle
• Avoid contact with antibacterial detergents/cleaners as they can damage the plastic. Combinations of detergents, cleaning products, sterilising solution, softened water and temperature fluctuations may, under certain circumstances, cause the plastic to crack. If this occurs, do not use. The pump body and breast milk containers are dishwasher safe but food colourings may discolour them. Follow guidelines in ‘How to clean and sterilise your ISIS iQ UNO™’ on pages 5-6.
Cracking or discolouration of pump parts
• Contact the AVENT Customer Services for replacements (see back cover for contact details).
Lost or broken parts
• Ensure the pump is correctly assembled and switched on with the power indicator illuminated ‘GREEN’.
• Make sure the lead between the electrical wall socket or battery pack and the pump is correctly connected.
Pump not responding
• 3 flashes, delay, 3 flashes etc – if the pump stops working and the power light is flashing RED the pump has detected a vacuum fault. Disconnect the power and check the control handle and diaphragm for obstructions or damage.
• Continuous RED pulsing flash – Low battery warning. You should consider replacing the batteries.
Pump light flashing RED
• The pump must be switched off via the control button in order to separate these parts. If the batteries go flat mid-pumping, you may experience difficulty. Replace the batteries or connect the pump to the mains. Turn the pump on by holding down the control button for 2 seconds – the light will turn GREEN. Now turn it off by holding the button for 2 seconds – the light will go off. You can now disconnect the pump from the power supply and should be able to separate the parts.
Difficulties separating the control handle from the pump body
20
a
b
c
d e
f
g
2
4
Important safeguards
READ ALL INSTRUCTIONS BEFORE USING YOUR ISIS iQ UNO™ BREAST PUMP
When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following.
WARNING – To reduce the risk of fire, electrocution or other personal injury:
• Always unplug from the electrical wall socket immediately after use.
• Do not use while bathing.
• Do not place or store the product where it can fall or be pulled into a bath or sink.
• Do not place or drop the control handle, battery pack or wall plug lead into water or other liquids.
• Do not reach for a product that has fallen into water. Unplug from the wall socket immediately.
• Close supervision is necessary when this product is used near children or persons with disabilities.
• Do not allow children or pets to play with the control handle, battery pack, wall plug lead or accessories as these parts may pose a choking or strangulation danger.
• Never operate this product if it has a damaged lead or plug, if it is not working properly, if it has been dropped or damaged, or has been submerged in water.
• Only use attachments recommended by AVENT.
• Do not use outdoors or where aerosol spray products are being used, or where oxygen is being administered.
• Equipment not suitable for use in the presence of flammable anaesthetic mixture with air, or with oxygen or nitrous oxide.
• Only use the wall plug lead and battery pack supplied with the product.
• There are no user serviceable parts inside the ISIS iQ UNO. Do not attempt to open, service or repair the ISIS iQ UNO yourself.
• Keep leads away from heated surfaces.
• This product is a personal care item and should not be shared between mothers.
• Do not attempt to remove pump body from the breast whilst under vacuum. Press the control button to revert to manual control then break the seal between the breast and the pump body with your finger.
• Do not operate unless control handle is connected to a pump body.
• Never use when sleepy or drowsy.
CAUTION – To reduce the risks of injury, device malfunction or failure:
• The product should not be left unattended when plugged into an electrical wall socket.
• Never drop or insert any foreign object into any opening.
• Make sure the voltage of the wall plug lead is compatible with the power source.
• Plug the end of the wall plug lead into the control handle first, then securely attach the wall plug into the electrical socket.
• Although compliant with applicable EMC directives, this equipment may still be susceptible to excessive emissions and/or may interfere with more sensitive material.
• Wash, rinse and sterilise the appropriate pump parts before each use.
• Do not continue pumping for more than five minutes at a time if no result is achieved.
b
d
e
g
h
k
l
m
n
o
c
5
How to clean and sterilise your ISIS iQ UNO
d
g
n
h
a
Sterilise in a steam steriliser (electronic, electric or microwave), or by boiling in water for 10 minutes.
The AVENT Electronic, Electric and Microwave Steam Sterilisers are specially designed to hold the ISIS™ breast pump parts and will remain sterile inside the steriliser for 3 hours, provided the lid is not removed.
Keeping your pump sterile and compact for travel
After sterilising all parts, insert the white valve (c) and diaphragm with stem (b) into the pump body (d) and clip the funnel cover (h) over the funnel and Let-down Massage Cushion™ (g). Now screw the travel cover (n) onto the pump body (d) in place of the milk container.
6
NEVER WASH OR STERILISE…
the control handle (a), battery pack (i) or wall plug lead (j).
These components DO NOT come into contact with your breast milk.
You can wipe the control handle clean, using a soft cloth.
Cleaning the pump body and breast milk storage components
Before you use your breast pump for the first time and every time before use, you must disassemble, wash and sterilise all the breast pump parts that come into contact with your breast milk. (See opposite).
You can use the dishwasher (top rack only) or hand wash in warm, soapy water and then rinse thoroughly.
Do not use antibacterial cleaners or detergents as they may cause the plastic to crack.