Avent ISIS IQ DUO INSTRUCTIONS

ISIS DUO
Twin Electronic Breast Pump
T
M
Instruction Booklet
ISIS iQ DUO™parts
jj
i
a
b
c
d
e
f
Pump motor
o
2
g
Controller pump
m
n
h
k
l
b
c
d
g
Second
h
pump
e
f
a
1 Control handle
b
Bottle parts
p
q
r
s
t
2 Silicone diaphragms
c
2 White valves
d
2 Pump bodies
e
4 Reusable milk containers (2 x 125ml/4oz and 2 x 260ml/9oz)
f
2 Stands (same as )
g
2 Let-down massage cushions™
h
2 Funnel covers (same as )
i
1 Control cable
j
2 Transparent tubes
k
1 Twin tubing
l
1 Double pumping connector
m
1 Pump motor
n
1 Electric adaptor
o
1 Wall plug lead
p
2 Dome caps
q
2 Newborn teats (0m+)
r
2 Screw rings
s
2 Travel covers
t
2 Sealing discs
h
f
Main parts in detail
Control button
Control handle
Light
Twin tubing port
Control cable socket
Control cable socket
Tubing port
Control handle
NEVER STERILISE/IMMERSE IN WATER!
Power socket
On/off switch
Pump motor
NEVER STERILISE/IMMERSE IN WATER!
3
Important safeguards
READ ALL INSTRUCTIONS BEFORE USING YOUR ISIS iQ DUO™ BREAST PUMP
When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following.
WARNING – To reduce the risk of fire, electrocution or other personal injury:
• Always unplug from the electrical wall socket immediately after use.
• Do not use while bathing.
• Do not place or store the product where it can fall or be pulled into a bath or sink.
• Do not place or drop the pump motor, control handle, electric adaptor or wall plug lead into water or other liquids.
• Do not reach for a product that has fallen into water. Unplug from the electrical wall socket immediately.
• Close supervision is necessary when this product is used near children or persons with disabilities.
• Do not allow children or pets to play with the pump motor, tubing, power supply or accessories as these parts may pose a choking or strangulation danger.
• Never operate this product if it has a damaged lead or plug, if it is not working properly, if it has been dropped or damaged, or has been submerged in water.
• Only use attachments recommended by AVENT.
• Do not use outdoors where aerosol spray products are being used, or where oxygen is being administered.
• Only use the electric adaptor supplied with the product.
• There are no user servicable parts inside the ISIS iQ DUO. Do not attempt to open, service or repair the ISIS iQ DUO yourself.
• Keep leads away from heated surfaces.
• This product is a personal care item and should not be shared between mothers.
• Never use when sleepy or drowsy.
CAUTION – To reduce the risks of injury, device malfunction or failure:
• The product should not be left unattended when plugged into an electrical wall socket.
• Never drop or insert any foreign object into any opening or tubing.
• Do not shorten the tubing.
• Make sure the voltage of the electrical adaptor is compatible with the power source.
• Plug the electric adaptor into the pump motor first, then securely attach the wall plug lead into the electric adaptor. Lastly insert the plug into electrical wall socket.
• Wash, rinse and sterilise the appropriate pump parts before each use.
• Do not continue pumping for more than five minutes at a time if no result is achieved.
4
How to clean and sterilise
NEVER WASH OR STERILISE…
the control handle (a), twin tubing (k), double pumping connector (l) or pump motor (m).
These components DO NOT come into contact with your breast milk.
You can wipe the pump motor and control handle clean, using a soft cloth.
Cleaning the pump bodies and breast milk storage components
Before you use your breast pump for the first time and every time before use, you must disassemble, wash and sterilise all the breast pump parts that come into contact with your breast milk. (See opposite).
You can use the dishwasher (top rack only) or hand wash in warm, soapy water and then rinse thoroughly.
Do not use antibacterial cleaners or detergents as they may cause the plastic to crack.
a
k
l
m
b
c
d
g
e
h
p
q
r
s
t
5
your ISIS iQ DUO
Sterilising the pump bodies and breast milk storage components
Sterilise these parts in a steam steriliser (electric or microwave), or by boiling in water for 10 minutes.
The AVENT electric and microwave steam sterilisers are specially designed to hold the ISIS breast pumps and the parts will remain sterile inside the steriliser for 3 hours, provided the lid is not removed.
Keeping your pump sterile and compact for travel
After sterilising all parts, clip the funnel cover (h) over the funnel and let-down massage cushion (g) and screw the travel cover (s) onto the pump body (d) in place of the milk container.
s
d
g
h
6
How to assemble your ISIS
If you are single or double pumping – to assemble
d
c
1
With clean hands, click the white valve (c) into the pump body (d) from the bottom making sure that the pointed side of the valve faces downwards.
f
e
2
Twist the milk container (e) onto the pump body until securely in place.
b
3
To ensure the pump doesn’t topple, insert the milk container into the stand provided (f).
7
4
Place the silicone diaphragm (b) into the pump body (d), making sure it fits securely around the edge, to create a seal. (This is easier if the diaphragm is wet.)