3
Before beginning installation determine what the unit is to be mounted onto. There are 3 options:
1. Directly onto a concrete surface, pavers or decking using aluminum base frame(s).
a. See install instructions “A” below (page 3).
2. Directly onto concrete, pavers, or decking without using the AVCON base frame(s)
a. See install instructions “B” below (page 3).
3. Directly onto the ground, sand, or any similar surface, using the AVCON Base Frame(s).
a. See install instruction “C” below (page 4).
Install Instruction “A” Concrete Base Mounting
1. Position Base Frame in desired location and position. Ensure sufficient clearance behind unit for
plumbing fixtures, hose bibs, water lines, etc. (See Instructions #2 Floor Frames - Pic. 2a & 2b)
2. Use appropriate masonry anchors to fasten the base frame into the concrete base or lags if
mounting onto decking.
a. Note: If mounting onto pavers, ensure there is sufficient base material beneath the pavers
to support unit and to prevent wind loads from toppling or moving unit.
b. It is necessary to install blocking when mounting onto decking.
3. Proceed to “Post Bracket Installation (See Instructions #1 Post Bracket Installation).
Install Instructions “B” (NO Base Frame)
1. Note: It is important for spacing between posts to be as specified below to ensure wall panels
and door fits correctly in opening. This step will require post brackets to be installed.
a. Note: A 36” single, double or Cabana the spacing from inside edge to inside edge between
all posts is 29.75”. For a 46” single, double or Cabana unit the spacing from inside edge to
inside edge of all posts is 39.75”.
b. It is recommended that wall panels be joined to posts before mounting onto pad or pavers.
This will require completion of the installation of all post brackets. (See Instructions #1 Post
Bracket Installation). There are four posts for a single - six posts for a double – eight posts
for a cabana unit. Next comes installing the wall panels to the post(s). (See Instructions #4
Wall Panel Installation).
c. The section chosen for the door opening and the section chosen for the removable shower
wall with faucets will require a single “U” channel header to be placed between adjoining
posts at the top. This will assist in maintaining proper spacing. (See Instructions #1d &
Instructions #5 for Proper Installation).
d. Once panels and headers are attached, position unit into place.
e. Before anchoring ensure all posts are plumb vertically and spaced identically apart between
posts.
f. Anchor posts using the appropriate anchors or lags in each of the holes in the base
plate. Shim as required to keep posts level and plumb.
g. Proceed to (Instructions #6 – Half Wall Panel Installation) for Half Wall Panel – If
none proceed to (Instructions #7 – Door Installation) for Door Installation.