Avaya PARTNER, 1600 DSL, 308EC, 012E400E, 400EC Instructions Manual

...
0 (0)

308EC Module

7-foot Line Cords

308EC Module

Expanding Your PARTNER® Advanced

Communications System

This document provides instructions for adding or replacing modules in your existing system. The modules you may add include:

1600 DSL (For use with PARTNER ACS Release 4.0 or later only)308EC (For use with PARTNER ACS Release 2.0 or later only)012E (For use with PARTNER ACS Release 5.0 or later only)PARTNER Messaging Release 1.0

PARTNER MAIL VS (PMVS)400E, 400EC

200E

206, 206E, 206EC

The instructions also apply to previous models of PARTNER, including the PARTNER, PARTNER PLUS, and PARTNER II Communications Systems. Please note the illustrations are examples only. Your system may look different.

Important Safety Instructions

!WARNING:

The following list provides basic safety precautions that should always be followed when using your telephone equipment:

1.Read and understand all instructions.

2.Follow all warnings and instructions marked on the equipment.

3.Unplug all telephone connections before cleaning. DO NOT use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.

4.The product should be serviced by (or taken to) a qualified repair center when service or repair work is required.

5.DO NOT use the product near water, for example, a wet basement location.

6.Never push objects of any kind into the slots or openings as they may touch dangerous voltage points or short out parts that could result in a risk of fire or electric shock. Never spill liquid of any kind on the equipment; doing so may result in serious damage to the components.

7.DO NOT use the telephone to report a gas leak in the vicinity of the leak.

8.The telephone equipment is provided with a three-wire grounding type plug. This is a safety feature. DO NOT defeat the safety purpose of the grounding type plug. DO NOT staple or otherwise attach the power supply cord to building surfaces.

!CAUTION:

DO NOT block or cover the ventilation slots and openings. They prevent the product from overheating. DO NOT place the equipment in a separate enclosure unless proper ventilation is provided.

Additional Safety Instructions for Installation Personnel

1.Install the equipment to meet all the environmental and electrical requirements listed in the documentation that came with your system.

2.DO NOT install equipment during a lightning storm.

3.DO NOT install telephone jacks in a wet location unless the jack is specifically designed for wet locations.

4.Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.

5.Use caution when installing or modifying telephone lines.

6.The control unit must be securely wall mounted.

SAVE THESE INSTRUCTIONS

Copyright 2002

518-456-500

All rights reserved.

Comcode 700217318

Printed in U.S.A.

Issue 3

 

PARTNER is a registered trademark of Avaya

Avaya PARTNER, 1600 DSL, 308EC, 012E400E, 400EC Instructions Manual

Using a 2-Slot Carrier

IMPORTANT: The processor module must already be mounted on the wall. If it is not, refer to the documentation that came with your system.

Tab

Tab

1Remove the clear, plastic protector from the connector on the rear of the new module (and the processor module if you are upgrading from a stand-alone system) by grasping the tabs and lifting.

2A) Before starting, remove the power cord from the wall outlet.

B)Remove the screw from the bottom of the wall-mounted module or modules.

C)If you are upgrading an existing

stand-alone system, skip to Step 4B.

3If you are replacing the second module in a 2-Slot Carrier, remove the two screws holding the carrier in place and gently pull the carrier off the modules.

Mounting

Tracks

4A) Slide the second module off the processor module and put it aside.

B) Slide the new module onto the processor module, making sure the mounting tracks interlock.

!CAUTION:

Do not force the module. If the module does not insert easily, remove it, clear any obstruction, and reinsert it.

5Attach the 2-Slot Carrier to the top right side of the two modules:

A)Align the carrier carefully and then push firmly until the connectors on the modules snap into the carrier.

B)Fasten the carrier to the modules using the two #4 screws included with the carrier.

1

4

Lines

2

5

3

6

 

ACS

308EC

 

Proc

Module

 

1018

1119

1220

Extensions

13

21

1422

1523

1624

1725

Re-insert the screw into the bottom of the 6modules. Tighten it until the processor

module is flush against the wall. Do not overtighten or the module will warp.

Lights (LEDs)

 

1

4

2

5

3

6

10

18

11

19

7A) Label the line and extension jacks.

B)Connect the line and telephone cords to the appropriate jacks on the new module.

C)Route each cord through the hook on the front of its module.

D)Connect the free end of each line cord to the appropriate network interface jack.

E)Connect the free end of each telephone cord to the modular connecting blocks for system extensions.

F)Gather the line and extension cords hanging below the hook and twist tie or wire wrap them.

8Press the power cord firmly into the power jack on the carrier. Plug the other end of the power cord into a properly grounded three-prong wall outlet not controlled by a switch.

9Check the green lights on the fronts of the modules:

A)If a single light is out, power down the carrier, reseat the module, and then power up the carrier.

B)If both green lights are out, power down the carrier, reseat both modules, and then power up the carrier.

C)If the lights are still out, see the Customer Support Document on the accompanying compact disc for information about whom you should contact.