Please read the manual thoroughly prior to equipment set-up,
operation and maintenance.
- 1 -
User Manual
Installation
Please read this manual thoroughly prior to equipment set-up, operation and maintenance.
Important!!! Please Read Before Installation
• If the unit has recently been transported on its side, please let the unit stand upright for a
minimum of 24 hours before plugging it in.
• Make sure the unit has reached the desired temperature before loading the unit with products.
• Make sure all accessories are installed (shelves, shelf clips, etc…) before plugging in the unit.
• Do not attempt to remove or repair any component of the unit. Consult an authorized service
technician for servicing / repair.
• Do not hang on doors or stand inside the unit.
• Do not store flammable, explosive or corrosive liquids or gas in or near the cooler.
• Please read through this manual in its entirety.
Cabinet Location Guides
• Install the unit on a strong and leveled surface.
- If the surface is uneven, the unit may be noisy.
- The unit may malfunction if the surface is uneven.
• Install the unit in an indoor, well ventilated area.
- For best performance, maintain 4” of clearance on both sides and the back of the unit at all times.
- Outdoor use may cause decreased efficiency and damage to the unit.
- Avoid direct sunlight.
• Avoid installation in a high humidity and / or dusty area.
- High humidity can cause the unit to rust and may decrease efficiency.
- Dust collected on the condenser coil may cause unit to malfunction.
- Malfunction due to high ambient temperatures, humidity, or improperly maintained
condenser coil will void the warranty.
• Select a location away from heat and moisture-generating equipment.
- High ambient temperatures may cause the compressor to malfunction.
- Malfunction due to high ambient temperatures and humidity will void the warranty.
- Moisture may cause rust to form on the compartment body which could affect the electrical
insulation.
- 2 -
User Manual
Electrical
• Please ensure that the required voltage is being supplied at all times.
• The unit should be plugged into a grounded and properly-sized electrical outlet with appropriate
over-current protection. NEVER USE AN ADAPTER PLUG! Please refer to the electrical
requirements on the unit’s nameplate.
• The unit should have its own dedicated outlet.
• Do not use extension cords.
• Do not unplug your cooler by pulling on the power cord. Grip the plug firmly and pull straight out
from the outlet.
• Ensure the unit is not resting on or against the electrical cord.
• If the unit is not in use for a long period of time, please unplug the unit from the outlet.
• To avoid shock and fire hazards, do not plug in or unplug the unit with wet hands.
• After unplugging the unit, wait at least 10 minutes before plugging it back in. Failure to do so could
cause damage to the compressor.
• If the power cuts off, wait at least 5 minutes before turning the unit on to avoid damage to the
compressor.
Temperature Controls
• Refrigerant LED - Compressor is on
• Fan LED - Fan is on
• Defrost LED - Defrost cycle is running
Functions
Set Temperature
Refrigerators are preset at the factory to run between 33 and 41 degrees Fahrenheit.
1) Press SET button
2) Press UP or DOWN buttons to adjust
3) Press SET button to set
NOTE: All other temperature control functions should only be used by an authorized service technician.
- 3 -
User Manual
Defrost System
Refrigerator coils are kept below the freezing point (32 degrees Fahrenheit). During compressor
down-time, the evaporator fan continues to circulate air through the evaporator coil. This air
circulation raises the coil temperature above the freezing point, melting any accumulated frost.
Run-off water is drained into the evaporator pan and evaporated.
Operation/Maintenance
NOTE: We strongly recommend that any servicing be performed by an authorized service technician.
Unplug the unit from the elecrical outlet before cleaning or making repairs.
Loading Product
• Do not block the air duct / fan at the top of the unit. Maintain a minimum of 4” of clearance
between products and the fan at all times.
• Ensure all shelves are sitting level and properly secured before loading products.
• Do not store flammable and explosive gas or liquids inside the unit.
Cleaning the Condensor Coil
• For efficient operation, keep the condenser surface free of dust, dirt, and lint.
• We recommend cleaning the condenser coil at least once per month.
• Clean the condenser with a commercial condenser coil cleaner and a soft brush, available from
any kitchen equipment retailer, or vacuuming the consenser with a shop vac or use Co2.
Cleaning the Fan Blades and Motor
• If necessary, clean the fan blades and motor with a soft cloth.
• If it is necessary to wash the fan blades, cover the fan motor to prevent moisture damage.
Cleaning the Interior of Unit
• When cleaning the cabinet interior, use a solvent of warm water and mild soap.
• Do not use steel wool, caustic soap, abrasive cleaners, or bleach that may damage the interior finish.
• Wash door gaskets on a regular basis, preferably weekly. Simply remove the door gasket from the
frame of the door, soak it in warm water and soap for thirty (30) minutes, then dry with soft cloth
and replace.
• Check door gaskets for proper seal after they are replaced.
• Periodically remove the shelves and shelf brackets from the unit, and clean them with a mild soap
and warm water.
- 4 -
User Manual
Trouble Shooting
Compressor is Not Running
Fuse blown or circuit breaker tripped.Replace fuse or reset circuit breaker.
Power cord unplugged.Plug in power cord
Thermostat set too high.Set thermostat to lower temperature.
Cabinet in defrost cycle.Wait for defrost cycle to finish.
Cabinet Temperature is too Warm
Thermostat is set too high.Set thermostat to lower temperature.
Airflow is blocked.Re-arrange products to allow for proper air flow.
Make sure there is at least four inches of clearance
from the fan.
Low refrigerant levels.Contact a service technician to chek refrigerant levels.
Door is slightly ajar.Make sure door is completely closed.
Interior Light is Not Working
Poor switch connection.Turn off light switch and turn it back on.
Bulb is not connected.Make sure the bulb is correctly inserted in the socket.
Bulb has burned out.Replace the bulb.
Condensation is Collecting on the Cabinet and/or Floor
Gasket is not sealing properly.Clean, repair, or replace the gasket as necessary.
Warranty Information
All Avantco Refrigeration units are backed by a 1 year parts and labor manufacturer’s warranty,
with an additional 4 year warranty on the unit’s compressor. For warranty inquiries or service,
first locate the serial number plate on the front of the unit, or inside the door jamb. Next, call
the 800 number located on the serial number plate. Be sure to have serial number available
when contacting service technicians.
This warranty does not apply to, and Avantco is not responsible for, any warranty claims made on
products sold or used outside of the United States.
- 5 -
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.