AID-185ST2
18.5” Bedside Terminal
Quick Reference Guide
Copyright 2015 Avalue Technology Inc., ALL RIGHTS RESERVED.
Part No. E20178ST2A0R

AID-185ST2
A Message to the Customer
THIS DEVICE COMPLIES WITH PART 15 FCC RULES. OPERATION IS
SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE.
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING
INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS
FOR A CLASS "A" DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES.
THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST
HARMFUL INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A
COMMERCIAL ENVIRONMENT. THIS EQUIPMENT GENERATES, USES, AND CAN
RADIATE RADIO FREQUENCY ENERGY AND, IF NOT INSTATLLED AND USED IN
ACCORDANCE WITH THE INSTRUCTION MANUAL, MAY CAUSE HARMFUL
INTERFERENCE TO RADIO COMMUNICATIONS.
OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE
HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO
CORRECT THE INTERFERENCE AT HIS OWN EXPENSE.
Avalue Customer Services
Each and every Avalue’s product is built to the most exacting specifications to ensure
reliable performance in the harsh and demanding conditions typical of industrial
environments. Whether your new Avalue device is destined for the laboratory or the factory
floor, you can be assured that your product will provide the reliability and ease of operation
for which the name Avalue has come to be known.
Your satisfaction is our primary concern. Here is a guide to Avalue’s customer services. To
ensure you get the full benefit of our services, please follow the instructions below carefully.
Technical Support
We want you to get the maximum performance from your products. So if you run into
technical difficulties, we are here to help. For the most frequently asked questions, you can
easily find answers in your product documentation. These answers are normally a lot more
detailed than the ones we can give over the phone. So please consult the user’s manual
first.
To receive the latest version of the user’s manual; please visit our Web site at:
http://www.avalue.com.tw/
2 AID-185ST2 Quick Reference Guide

Quick Reference Guide
Content
1. Getting Started ........................................................................................................ 4
1.1 Safety Precautions .................................................................................................... 4
1.2 Packing List ............................................................................................................... 4
1.3 System Specifications ............................................................................................... 5
1.4 System Overview ................................ ................................ ................................ ...... 8
1.4.1 I/O View ................................................................................................................................... 8
1.5 System Dimensions .................................................................................................. 9
AID-185ST2 Quick Reference Guide

AID-185ST2
Always completely disconnect the power cord from your
chassis whenever you work with the hardware. Do not
make connections while the power is on. Sensitive
electronic components can be damaged by sudden power
surges. Only experienced electronics personnel should
open the PC chassis.
Always ground yourself to remove any static charge before
touching the CPU card. Modern electronic devices are very
sensitive to static electric charges. As a safety precaution,
use a grounding wrist strap at all times. Place all electronic
components in a static-dissipative surface or static-shielded
bag when they are not in the chassis.
1 x Wall Box
1 x Mother Board With Metal Plate
1 x 18.5” Display
1 x 19V Adapter
1 x Power Cord
1 x Handset (option)
4 AID-185ST2 Quick Reference Guide

18.5” WXGA TFT (1366 x 768 resolution)
20% to 100% user controllable
USB 5-wire resistive
Or Projected Capacitive touch
Peripherals and Device Interfaces
USB interface, integrated on bottom of display terminal
USB interface, integrated on the top of the bezel (optional)
USB interface, integrated on the back of the display terminal (optional)
Support pre-installed USB handset control with integrated barcode
scanner, extend audio jack, an USB port and hall effect hook on/off
detection.
Support pre-installed grab handle which provides alternative RFID
location.
2 x USB 3.0 ports for external peripherals in lower connector recess
2.0W RMS per channel speaker/ headphone output
Software speaker/ headphone speaker mute
Infinite baffle rear / downward facing
Capacitive Touch Keys (Default)
On / Off (Backlight on/off)
Increase / Decrease (Optional)
Increase / Decrease (Optional)
Wall Box Interfaces To Support
Standard USB 3.0 cable at 3.2M as default cable deployed in the A-Frame
Arm
Standard HDMI cable as default cable deployed in the A-Frame Arm
DC power cable as default cable deployed in the A-Frame Arm
External I/O User Interface
2 x USB3.0 for external peripherals in lower connector recess ¸ 1 x USB
1.3 System Specifications
Quick Reference Guide
AID-185ST2 Quick Reference Guide

AID-185ST2
3.0 for external peripherals in top connector
Mechanical & Environmental
5~90% Relative Humidity, Non-condensing
1. Hinge mount for Remedi A-Frame articulated arm (Optional)
2. VESA mount 75mm x 75mm (Optional)
Refer to AID-185M (Using the same Tooling)
463.95mm x 289.95mm x 61.7mm (W/O any Peripherals)
With wall box
a. CB/CE: CE Class A, MDD IEC/EN 60601-1
b. North America: FCC Class A, UL 60601-1. c/UL60601-1
c. Australia: C-Tick / A-Tick (IP grade)
Standard(0.00454G²/Hz,1.5Grms 5~500Hz)
6 AID-185ST2 Quick Reference Guide

Quick Reference Guide
External Function & Support
Support Avalue A-Frame arm for the monitor
Easy access on the chassis for LAN cable from the central router to the
internal M/B
Venting holes on the lower recess
Internal System Configuration
BayTrail E3845 1.9GHz
3.5” SBC.
Fan-less heatsink for the M/B
Power supply
Splitter DC-to-DC
Support DC-in x 1 from PSU and DC-out x 2 to
1. The M/B
2. The Extended DC cable from monitor
Power supply
PSU AC-to-DC
19V/90W AC-to-DC power adaptor
Mechanical & Environmental
Full range 100V~240V AC-in
5~90% Relative Humidity, Non-condensing
4-point mounting per chassis design
292 mm x 361.7 mm x 89 mm (Excluding the arm post)
With Display
A. CB/CE: CE Class A, MDD IEC/EN 60601-1
B. North America: FCC Class A, UL 60601-1. c/UL60601-1
C. Australia: C-Tick / A-Tick (IP grade)
Standard(0.00454G²/Hz,1.5Grms 5~500Hz)
Note: Specifications are subject to change without notice.
AID-185ST2 Quick Reference Guide

AID-185ST2
2 x USB 3.0 + USB 2.0 connector
1.4 System Overview
1.4.1 I/O View
8 AID-185ST2 Quick Reference Guide

1.5 System Dimensions
Quick Reference Guide
(Unit: mm)
AID-185ST2 Quick Reference Guide