Avalon Firestyles TRV GS Blower User Manual

864TRV GS – 564 SS GS
Blower Installation Instructions (sku 99000162)
Packing List
Wiring Harness
Rheostat
Snap Disc
(4) Brass Bushings
Rheostat Nut
Rheostat Knob
(4) #8 x ¾” Screws
Warnings
WARNING: Make sure power to the stove has been shut off prior to installation (Unplug the stove).
Do not connect 110-120 VAC to the gas control valve or wiring system of this appliance.
NOTE
: Install the blower prior to connecting the gas line or installing the stove. If using the
GreenSmart™ remote, install it after the blower is in place.
NOTE
: If using the GreenSmart™ remote, refer to the special instructions below (GS1 or GS2). When
using the GreenSmart™ remote, certain installation steps may be disregarded or altered.
Special Instructions for GreenSmart™ 2 Remote (GS2)
When using the GS2 remote, power for the blower is routed through the fuse and IFC, bypassing the rheostat and snap disc included with the blower kit (these items may be kept for spare parts).
HINT: Install the blower(s) with the IFC removed. Connect the wiring as shown below. Disconnect the blower power input (see “a” below).Connect the blower wiring harness to the fuse output (see “b” below).
Disconnect and discard the electrical line intended to connect the snap disk to the rheostat (carefully remove the wire tie from the wiring harness – see “c”). Attach the jumper wire (included with the remote) to the wires labeled “SNAP DISC” (see “d” below). Attach the blower power input (see “e”) to “FAN” lead on the fuse harness (pre-connected to the IFC). This circuit bypasses the rheostat and snap disc (these components included with the blower kit are not used and may b e kept for replacement part purposes).
SNAP DISC
d
c
POWER INPUT
a
b
3.15
A FUS
E
Page 1 of 4 17601556 - 9/6/13 © Travis Industries, Inc.
e
864TRV GS – 564 SS GS
Blower Installation Instructions (sku 99000162)
Special Instructions for GreenSmart™ 1 Remote (GS1)
When using the GS1 remote, the rheostat is bypassed and the power connected to the fan extension module. Disconnect and discard the electrical line that leads from the snap disk to the rheostat (carefully remove the wire tie and
“SNAP DISK” label from the wiring harness – see “a”). Attach the lead from the power input to the snap disk (see “b”). Attach the wiring harness molex to the power lead (included with the remote – see “c”). Then plug the power lead into the outlet labeled “FAN” on the fan control module. Disregard the instructions for installing the rheo stat (steps 6 through 9) or attaching power to the wiring harness (step 4).
Installation
1 Remove the concealment cover (see Figure 1).
Figure 1
2 Unscrew the four screws holding the control cover in place (see Figure 2). Carefully remove the control
cover and place it aside (leave the wiring intact - see Figure 3)
Figure 2
Figure 3
Page 2 of 4 17601556 - 9/6/13 © Travis Industries, Inc.