Avalon Firestyles Large Pedestal User Manual

Page 1
Large Pedestal (1750, Olympic)
Compatibility:
1750 Wood Stove
Olympic
Packing List:
Pedestal
(2) 3/8-16 x 3/4” Bolts w Washers
(2) 5/16” x 3” Lag Bolts w Washers
Screen with (6) Staples
Cover Plate (for use when using outside air on the Olympic)
Insulation
Pedestal Attachment
99200129
NOTE: If using outside air, install it prior to attaching the pedestal (see Outside Air Installation on page 2 and 3).
Two pedestal bolts attach the pedestal to the bottom of the stove.
9/16" Wrench
Stove
The lag bolts and washers may be inserted through these holes to anchor the pedestal to the floor.
The dowels insert onto the front and back edge of the pedestal base.
Page 1 of 4 12/21/07 © Travis Industries, Inc.
Pedestal
Page 2
Large Pedestal (1750, Olympic)
99200129
Using Outside Air with the Olympic Wood Stoves
The following outside air knock-out must be removed and the cover plate installed when using outside air with the Olympic wood stoves.
Outside Air Knock-Out for Standard Pedestals
Outside Air Knock-Out for Stoves on Legs or Stoves Using Ash Pan Pedestal
Rear Blower Knock-Outs
Knock-Out for
the Ash Pan
Pedestal Drop
Chute
FRONT OF STOVE
Install the included cover plate so air is drawn from below, not the front. See the directions below.
Remove the two screws on the cover plate to remove the piece that
fits over the air control rod. Then replace the piece when the cover
plate is in place.
The cover plate has a clip which attaches it underneath the air control.
Air Control Rod
Page 2 of 4 12/21/07 © Travis Industries, Inc.
Page 3
Large Pedestal (1750, Olympic)
AA
AA AA
AA
99200129
Outside Air Installation – Using the Outside Air Kit (99200139)
a
Tuck insulation (included with the pedestal) under both sides of the pedestal and under the holes on the base of the pedestal. This prevents air from being drawn from below the pedestal.
e
Secure the flex duct to the air duct assembly using the included hose clamp. Attach the outside air duct assembly to the pedestal with the same screws that held the cover plate in place.
3" Dia. Flex Duct
(4' max. length)
Slide the cover plate over the flex duct then attach the flex duct to the hood with the included hose clamp. Secure the cover plate to the wall with the included screws (and drywall anchors if needed). HINT: The flex must be fully stretched and the ends cut square and flatted for it to fit properly. The tube on the hood and air duct may be crimped if necessary.
Remove the cover
b
plate on the pedestal.
Cover Plate
d
Seal the area around the tube to prevent air from entering through the wall.
Silicone
Select a location between framing members for the wall penetration. NOTE: If wall is thicker than 8", attach the flex duct to the hood then slide the hood into place.
Slide the hood through the wall and secure to the outside wall with the two included screws.
Min. 3"
Silicone
Dia. Hole
8"
Hood with Rodent Screen
c
Page 3 of 4 12/21/07 © Travis Industries, Inc.
Page 4
Large Pedestal (1750, Olympic)
99200129
Outside Air Installation – Through the Pedestal into the Crawl Space
This pedestal has an internal air duct that may be used to direct air to the firebox. Outside air is then drawn from the crawl space under the stove (check with local building codes for requirements in your area). See the directions below for installation details.
1 Determine the location of the hole placed under the pedestal. The illustration below details the location of the
pedestal in relation to the front of the stove. The hole should be at least 16 square inches.
Top View
The faceplate of the Olympic is 1/4" in front of the forward edge of the pedestal base.
The faceplate of the 1750 is 2-1/2" in front of the forward edge of the pedestal base.
26"
16"
17"
19-3/4"
Outside air may be drawn from this area underneath the pedestal (min. 16 square inches)
Pedestal Base (with dowels)
FRONT
2 Attach the included screen over the hole (staples are included with the pedestal). Tuck insulation under both
sides of the pedestal and under the holes in the base of the pedestal (see step “a” on the page 2). This prevents air from entering under the pedestal.
Screen is used to prevent
Insulation is used to seal the side edges of the pedestal .
rodents from entering.
Staples are used to attach the screen to the floor.
3 Attach the stove to the pedestal.
Page 4 of 4 12/21/07 © Travis Industries, Inc.
Loading...