Product Specifications
Model Name
Item
ASW-H09A4/SAR1DI ASW-H12A4/SAR1DI
Cooling Capacity 9000(4947-10918) 12000(5459-12624)
Heating Capacity
BTU/h
9400(4777-11260) 12000(5459-14330)
Cooling 820(380-1350) 950(500-1500)
Input
Heating
W
950(380-1540) 1150(430-1600)
Cooling 3.57(1.50-5.90) 4.12(1.70-6.50)
Rated Current
Heating
A
4.13(1.70-6.70) 5.00(1.90-7.00)
Cooling 10.4(8.09-13.0) 11.5(8.4-10.9)
E.E.R
Heating
BTU/h.W
9.88(7.31-12.6) 10.4(9.0-12.7)
Dehumidifying Kg/h 1.2
1.4
Power-Supply φ--V--Hz 1/220-240~/50
Indoor 420 580
Air Circulation
Outdoor
m3/h
800 800
Indoor 39 42
Noise Level
Outdoor
dB
53 53
Indoor 19 19
Motor Input
Outdoor
W
35 35
Indoor 802*265*185 880*286*196
Dimension(WxHxD)
Outdoor
mm
818*320*540 818*320*540
Indoor 9.5 11
Net Weight
Outdoor
kg
36 36
Liquid φ6.35×3600 φ6.35×3600
Connection Pipe(OD*L)
Gas
mm
φ9.52×3600 φ9.52×3600
Refrigerant(R-410A) g 900 1100
Operation control LCD Wireless remote
1
Dimensions
(1) Indoor unit
MODEL
ASW-H09A4/SAR1DI
ASW-H12A4/SAR1DI
DIM
W mm 802 880
H mm 185 196 D mm 265 286
(2) Outdoor unit
MODEL
ASW-H09A4/SAR1DI
ASW-H12A4/SAR1DI
DIM
W mm 760 760
H mm 540 540 D mm 260 260
2
Refrigeration Cycle Diagram
Pipe size (Diameter: Ø) Max. Piping Length Max. Elevation
MODEL
(m) (m)
Liquid(inch) Gas(inch)
ASW-H09A4/SAR1DI
1/4 3/8 15 3-4
ASW-H12A4/SAR1DI
1/4 3/8 15 3-4