Auto Test AutoStop Mini Plus User Manual

User Manual
Version 2.014
AutoStop
Mini Plus
N17561
DECLARATION OF CONFORMITY We, AutoTest products Pty Ltd. declare under our sole responsibility that the product Mini Plus is in conformity with the provisions of the following Council Directive: 1999/5/EC. A copy of the Declaration of Conformity is available from http://www.autotest.net.au
© AutoTest Products Pty Ltd (AutoTest) [2015]. Copyright in the drawings, information and data recorded in this document (the
information) is the property of AutoTest Products. This document and the information are solely for the use of the authorised recipient and this document may not be used, copied, or reproduced in whole or part for any purpose other than that for which it was supplied by Auto Test Products. Auto Test Products makes no representation, undertakes no duty, and accepts no responsibility to any third party who may use or rely upon this document or the information.
Under no circumstances shall Auto Test Products be responsible for any loss of data or income or any special, incidental, consequential or indirect damages howsoever caused. The contents of this document are provided "as is". Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy, reliability of contents of this document. Auto Test Products reserves the right to revise this document or withdraw it at any time without prior notice.
Please dispose of batteries properly.
AutoStop Mini Plus User Manual v2.014 Page 1
Table of Contents
AutoStopTM Mini Plus
1 UNPACKING AND FIRST TIME USE .................................................................... 2
1.1 Unit activation ....................................................................................................... 2
1.2 Self Test and Battery Check ................................................................................. 2
2 FOR YOUR SAFETY .............................................................................................. 3
3 OPERATION ........................................................................................................... 4
3.1 Test Conditions and Test Area ............................................................................ 4
3.2 Set-Up in Vehicle ................................................................................................... 4
3.3 Changing the units ................................................................................................ 4
3.4 Running the Test ................................................................................................... 5
3.5 Test Instructions Summary .................................................................................. 6
3.6 Other Functions .................................................................................................... 7
3.7 Printing on Bluetooth printer (optional accessory) ........................................... 7
3.8 Menu Reference .................................................................................................... 8
4 DOWNLOADING .................................................................................................. 12
4.1 Systems Requirements ...................................................................................... 12
4.2 Installing the Data Logger Software From CD .................................................. 12
4.3 Installing the Data Logger Software From Internet .......................................... 12
4.4 Downloading Tests using the Data Logger Software ...................................... 12
4.4.1 Downloading via USB .................................................................................. 13
4.4.2 Downloading via Bluetooth ......................................................................... 21
4.5 Using the Data Logger software ........................................................................ 26
5 SPECIFICATION .................................................................................................. 28
5.1 Hardware Specifications .................................................................................... 28
5.2 Features ............................................................................................................... 28
6 CALIBRATION PROCEDURE.............................................................................. 29
6.1 Return of AutoStop Mini Plus for Calibration ................................................... 29
6.1.1 Packaging ..................................................................................................... 29
6.1.2 Shipping........................................................................................................ 29
6.1.3 Documentation ............................................................................................. 29
7 TROUBLESHOOTING .......................................................................................... 29
8 WARRANTY ......................................................................................................... 30
9 AUTHORISED SERVICE AGENTS: ..................................................................... 31
AutoStop Mini Plus User Manual v2.014 Page 2
1 UNPACKING AND FIRST TIME USE
Congratulations on your choice of an AutoStop Mini Plus. Please take the time to read
this User’s Manual before using the AutoStop Mini Plus in the field. Incorrect or
inappropriate use of this instrument may void the warranty. Retain the packing materials for future shipping and transport of the unit for calibration every two years.
Please complete the warranty registration card and post it to AutoTest Products Pty Ltd, alternatively visit our website www.autotest.net.au and complete your warranty registration on line. Your warranty registration ensures that you are kept up-to-date on any software or hardware changes to your AutoStop Mini Plus.
The packing box of your AutoStop Mini Plus should contain the following:
1. AutoStop Mini Plus
2. User Manual
3. Warranty Registration Card
4. Calibration Certificate
5. Power Adaptor Optional Accessories:
MiniPlus Data logger software CD-ROM Data Download USB cable Bluetooth Wireless printer Rare Earth magnet motorbike kit
AutoStop Mini Plus determines triaxial deceleration, measuring forward as well as sideways deceleration (lane change). AutoStop Mini Plus has a twelve-button operation via a tactile membrane keypad with LCD display. It is lightweight (500grms) and compact (200x70x40mm) and can be installed anywhere in the vehicle.
1.1 Unit activation
When you receive your new Meter, you must activate it before you can use it. When you turn it on for the first time, you will come to the main menu. The first option on the menu will be “Activate”. Press the ENTER key to begin activation. You are now prompted to enter the 5-digit serial number, one digit at a time. Press ENTER to confirm, DEL to re-enter. Once your meter is activated, it is ready for use, and you will never need to perform the activation again.
1.2 Self Test and Battery Check
The self-test function is activated each time the AUTOSTOP™ Mini Plus is powered, it checks the clock, the battery level and the calibration due date. The sequence as follows:
- after initial power up and start-up splash screen sequence the display will indicate
“Test?” If the battery does not have sufficient charge to be used, then it will display “Warning: Battery Low”.
AutoStop Mini Plus User Manual v2.014 Page 3
2 FOR YOUR SAFETY
Read these simple guidelines. Not following them may be dangerous. Read the complete user guide. Further detailed information is given in this manual.
SWITCH ON SAFELY
Do not switch the device on when wireless device use is prohibited or when it may cause interference or danger.
INTERFERENCE
All wireless devices may be susceptible to interference, which could affect performance.
SWITCH OFF WHEN REFUELING
Do not use the device at a refuelling point. Do not use near fuel or chemicals.
SWITCH OFF NEAR BLASTING
Follow any restrictions. Do not use the device where blasting is in progress.
USE SENSIBLY
Use only in the positions as explained in the product documentation.
QUALIFIED SERVICE
Only qualified personnel may install or repair this product.
ACCESSORIES AND BATTERIES
Use only approved accessories and batteries. Do not connect incompatible products.
WATER-RESISTANCE
Your device is not water-resistant. Keep it dry.
CONNECTING TO OTHER DEVICES
When connecting to any other device, read its user's guide for detailed safety instructions. Do not connect incompatible products.
AutoStop Mini Plus User Manual v2.014 Page 4
3 OPERATION
3.1 Test Conditions and Test Area
The vehicle must be stationary (at a complete stop) prior to commencement of the test. Ideal conditions are to test the vehicle at a location where no other or only few vehicles are present. However, if it is necessary to use another area, such as a public road, only commence the test if there is no danger of an accident. The test area should be a sealed, flat bitumen road. The headwind should be less than 15km/h. Test starts with first movement of the vehicle, and concludes when the vehicle comes to a complete stop. The forward direction of the vehicle is determined when the vehicle first starts to move. For example, if the test is started when the vehicle pulls out from the kerb, then the calculated forward direction will be at an angle to the true forward direction. The first movement of the vehicle must be in the forward direction. Please be sure to follow the brake test procedure detailed in the latest version of the relevant Inspection Manual when carrying out a statutory test.
3.2 Set-Up in Vehicle
Attach the Mini Plus to the dashboard, front passenger seat, foot well or centre console so that the screen is clearly visible and the buttons are accessible. AutoStop Mini Plus is self-aligning by identifying its orientation during acceleration at the beginning of each test
- Mini Plus can be installed at any angle facing any orientation, but must be secure for the entire duration of the test as movement can cause wrong deceleration readings.
Note: If Mini Plus is configured for use in heavy vehicles, it should only be mounted flat on a levelled surface, or on the side-window of the vehicle using suction cup mounts. In such cases, if the tilt angle of the device is outside the tolerance level, the device will
display “Slope too large”. The tilt warning message will disappear automatically once the
slope angle of the unit is adjusted to the level plane (in reference to ground).
3.3 Changing the units
The resultant average deceleration and max deceleration can be viewed in different units like g, m/s2 or %. The speed, stopping distance and the side shift can be viewed can be in imperial and metric units. To select the units, press ON/OFF button to power up the
unit. The display will show “Test?” press until it displays “Set Accel. Unit?” to change the units of average and maximum deceleration. There are three options for
acceleration units: m/s2, g or %. Press to select a unit and ENTER to set a unit.
Acceleration Units
m/s2
g
% (where 0% = 0.00g, 100% = 1.00g)
The units of speed, stopping distance and side shift can be changed to imperial or metric. Select Imperial/Metric? option from the main menu. Press ENTER. Select imperial or metric units and press ENTER. The speed, stopping distance and side shift in both units are as follows:
Unit
Imperial
Metric
Speed
Miles per hour (mph)
Kilometres per hour (km/h)
Stopping distance
Feet (ft)
Meter (m)
AutoStop Mini Plus User Manual v2.014 Page 5
3.4 Running the Test
Turn on AutoStop Mini Plus by pressing ON/OFF. The Mini Plus will go through a start-up procedure and show the calibration due date. The display will show “Test?” press ‘ENTER’. The Mini Plus will initialise the test procedure by prompting the user to enter “Examiner ID”, “Customer Name” and “Vehicle Registration No.” The Mini Plus will
remember the previously stored Examiner ID. To change the Examiner ID, press then key-in the new ID. Once the vehicle registration number has been entered, the Mini Plus will then prompt the user select the vehicle category. The vehicle category can either be “Light Vehicle” (VEHICULE LEGER) or “Heavy Vehicle” (VEHICULE LOURD). Once the vehicle category has been selected, the Mini Plus will prompt the user to specify the vehicle type. The vehicle-type is selected from the following tables depending on the previously selected vehicle category.
Vehicle types for Light Vehicles
(VEHICULE LEGER)
Type
Limit value (m/s2)
VP > 01/10/1989
5.0
VUL > 01/10/1989
5.0
1956 < VP < 1989
5.0
1956 <VUL < 1989
4.5
VP < 31/12/1955
3.5
VUL < 31/12/1955
3.0
Vehicle types for Heavy Vehicles
(VEHICULE LOURD)
Type
Limit value (m/s2)
M1 >3,5t
5.0
M2,M3 avec ABR
5.0
M2,M3 sans ABR
4.8
N1 > 29/09/1989
5.0
N1 < 30/09/1989
4.5
N2,N3 > 01/01/12
5.0
1989<N2,N3< 2012
4.5
N2,N3 < 30/09/89
4.3
Ensemble routier
4.3
Press the (→) and DEL keys to scroll through the list of vehicle types. When a particular vehicle type is displayed on the screen, press the ENTER key to select it and continue to the next step. The Mini Plus will then show “Press any key to commence the test”. After pressing any key, the display will show “Ready to go”. Drive the vehicle to the desired test speed and apply the brakes. When the vehicle has come to a halt the Mini Plus will finish the calculations and will display the results – you can then simply compare them with the specific brake values according to your local regulations. The results that will be displayed are:
AutoStop Mini Plus User Manual v2.014 Page 6
1. Average Deceleration (SRV36)
2. Maximum Deceleration
3. Test Duration
4. Pass/Fail Outcome
The pass/fail outcome of the test will be determined based on the type of the vehicle selected and the measured value of the average deceleration (SRV36). If the measured average deceleration (SRV36) is below the limit value, the test outcome will be ‘Fail’ (INSUFFISANTE). Otherwise, the test outcome will be ‘Pass’ (OK) when the measured SRV36 value is above or equal to the limit value.
3.5 Test Instructions Summary
Screen Display
Instruction
Keys to Press
Blank Screen
Switch On
ON/OFF
Initial splash screen
Press any key to skip
Test?
Start to run test
ENTER
Examiner?
Enter Examiner ID if it is not stored previously
Press key and key-in ID and press ENTER
Customer:
Enter customer name
Key-in customer name and press ENTER
Reg No:
Enter the Registration no
Key-in registration no and press ENTER
Test with GPS?
Conduct test with GPS
Press ENTER for YES and any other key for NO
Press any key to commence the test
Press any key to commence the test
Press any key to commence the test
Ready to go…
Accelerate the vehicle
Prelude…
Forward direction detected. Keep accelerating to desired speed, then brake
Sampling…
Wait for result
Calculating…
Wait for result
Avg Decel (SRV36), Max Decel, duration, pass/fail
Displays the test results of brake test
Press ENTER
Save?
To save test result
Press ENTER to save or to go to next item
Print?
To print test result on remote Bluetooth printer
Press ENTER to print or to go to next item
Print Another?
To print duplicate test result
Press ENTER if you want to print the test result or press
Repeat Test?
To repeat same test
Press ENTER to repeat the test or to go to main
menu.
Must:
Fix Mini Plus securely Install in a stationary vehicle Must drive in a straight line
AutoStop Mini Plus User Manual v2.014 Page 7
Must not:
Turn car after starting test Hold unit in hand or on body Move Mini Plus after pressing start Skid wheels
“A good stop is like stopping at a traffic light – steady.”
3.6 Other Functions
View Results? : Press ENTER and display will show the test number and the
date and time of test. Press to select the required test number and press ENTER to view each test result. Mini Plus can store up to ninety test results. At the end there is a “Clear Results?” option to clear all test results. The Mini Plus will hold ninety tests and will display “Memory full” when the memory is full and stored data has to be cleared.
Adjust Contrast? : Press ENTER to adjust the contrast of the display and press
to increase the contrast and DEL to reduce contrast.
Set acceleration units? : Press ENTER to select acceleration unit. The
acceleration units can be changed to g, percentage or m/s2
Imperial/Metric? : Press ENTER to change to Imperial or Metric units.  View Clock? : This function is for viewing the date and time set on Mini Plus.
Press ENTER to view the clock
Battery Life? : Press ENTER to view the battery life of the Mini Plus  View Accel? : This function is to view the X, Y and Z-axes of the accelerometer.
Press ENTER to view these values.
View Test Count? : This function is to view the total number of tests carried on
the Mini Plus after calibration. Press ENTER to view the test count.
Language? : This function allows users to select a different interface language.
Press ENTER to view available languages. Note: results obtained using French language will be based on SRV-P036 standard.
3.7 Printing on Bluetooth printer (optional accessory)
In order to print the test results on Bluetooth printer, switch on the printer and give print command from the Mini Plus. Mini Plus will display “Finding printer” while searching for the Bluetooth printer. Once the Bluetooth printer is found, Mini Plus will automatically issue the printout of the test via the Bluetooth printer. Note: When Mini Plus is not able to find a Bluetooth printer it will display “No printer found” and "Find printer? Y/N" messages on the LCD screen. Switch OFF the Bluetooth printer and switch it back ON and select “Find printer? Y” from Mini Plus to retry printing.
AutoStop Mini Plus User Manual v2.014 Page 8
3.8 Menu Reference
Display Main Menu
Display Sub Menu
Description
Keys to Press
Activate Unit?
This to activate the MiniPlus as the unit is locked prior to shipment
Press ENTER or
to view next
item on main menu
Please enter the 5­digit Serial Number code of this unit, then press ENTER to confirm, or DEL to re-enter. Press any key to begin
Press any key to go to next sub­menu
Code: -----
This is to enter the 5­digit serial number code
Key-in the 5-digit serial number and Press ENTER
Unit Activated
This is an indication that the unit has been activated
Press ENTER
Test?
This does not appear if unit is not activated. This is for carrying out the test
Press ENTER
Examiner?
This is for enter the name of the person carrying out the test.
Press , when cursor appears key-in the examiner name
Customer:
This is for entering the name of the customer
Key-in the customer name and Press ENTER
Reg No:
This is for entering the registration number of the vehicle under test
Key in the registration number and press ENTER
Test with GPS?
This is to decide whether or not the test require GPS location
Press ENTER for YES and any other key for NO
Press any key to commence test.
This is an indication to press any key to commence the test
Press any key
Stabilising…
This is when the unit is checking its stability
Ready to go…
Accelerate the vehicle to the desired speed
Prelude…
This indicates forward motion of the test vehicle.
AutoStop Mini Plus User Manual v2.014 Page 9
Sampling…
This indicates that the brakes have been applied and it is sampling data for calculation
Calculating…
This indicates that the test is complete and the unit is calculating the results
The test results are displayed in a scrolling text showing the
#AvgDecel, MaxDecel, Duration, Pass/Fail
Save?
This is for saving the current test result
Press ENTER to save or to go to
next sub menu
Print?
This is for printing the test result via Bluetooth printer (optional accessory)
Press ENTER to print or to go to
next sub menu
Print Another?
This option is to print another copy of the same test
Press ENTER to print or to go to
next sub menu
Repeat Test?
This is for repeating test
Press ENTER
View Results?
This is for viewing the stored data
Press ENTER to view results or to
go to next sub menu
3/n
This is third (last) result out of n stored results
Press ENTER to view results of the second test or
Press to go to next sub menu
2/n
This is second result out of n stored results
Press ENTER to view results of the second test or
Press to go to next sub menu
1/n
This is first result out of n stored results
Press ENTER to view results of the second test or
Press to go to next sub menu
Clear Results?
This is to clear the results stored on Mini Plus
Press ENTER to clear stores data or
press to go back to the main menu
AutoStop Mini Plus User Manual v2.014 Page 10
Are you sure? Y/N
This is a confirmation for clearing the results stored on Mini Plus
Use → to select
Yes/No, then press ENTER
Set Accel. Unit?
This is to set the units of average and maximum deceleration
Press ENTER to set the acceleration
unit or to go to next main menu
Accel unit: m/s2
This is to set the units of average and maximum deceleration in terms of ‘m/s2’
Press ENTER to set or to select
another unit
Accel unit: g
This is to set the units of average and maximum deceleration in terms of ‘g’
Press ENTER to set or to select
another unit
Accel unit: %
This is to set the units of average and maximum deceleration in terms of ‘%’
Press ENTER to set or to select
another unit
Imperial/Metric?
This is to change the units of speed, stopping distance and side shift
Press ENTER to set the units or
to go to main
menu
I/M: Metric
This is to change the units of speed, stopping distance and side shift to metric
Press ENTER to set the unit to
metric or press to select another unit
I/M: Imperial
This is to change the units of speed, stopping distance and side shift to imperial
Press ENTER to set the unit to imperial or press
to select another
unit
View Clock?
This is to view the date and time on the Mini Plus
Press ENTER to set the units or
to go to main
menu
Date: dd/mm/yy
This shows the date on the Mini Plus
Wait until display shows time or
Press to view time or Press ENTER to go to main menu
Time: hh:mm:ss
This shows the time on the Mini Plus
Note: press ‘1’ to toggle
daylight saving. When daylight saving is enabled, ‘*’ will be displayed on LCD.
Wait until the display shows date
or Press to view date or Press ENTER to go to main menu
AutoStop Mini Plus User Manual v2.014 Page 11
Battery Life?
This shows the battery life on Mini Plus
Press ENTER to view battery life or
press to return to main menu
View Accel. ?
This is to view X, Y and Z-axes of the accelerometer
Press ENTER to view acceleration
or press to return to main menu
Vsum :
This shows the vector sum of all three axes.
Press to view another axis or press ENTER to go to main menu
X:
This shows the X-axis of the accelerometer
Press to view another axis or press ENTER to go to main menu
Y:
This shows the Y-axis of the accelerometer
Press to view another axis or press ENTER to go to main menu
Z:
This shows the Z-axis of the accelerometer
Press to view another axis or press ENTER to go to main menu
Tilt :
This shows the tilt angle of the brake meter
Press to switch to another screen or press ENTER to go to main menu
View Test Count?
This is to view the total number of tests carried out on the Mini Plus
Press ENTER to view the count or
to go to main
menu
Printer Type?
Allows user to configure printer settings
Press ENTER to open menu
Bluetooth: YES
To enable or disable Bluetooth printer
Note: If Bluetooth printer is disabled, the printing will occur via RS232.
Press → to toggle
between “YES” and “NO”, press
ENTER to save settings and return.
Language?
This allows users to change the unit interface language.
Press ENTER to view available languages
AutoStop Mini Plus User Manual v2.014 Page 12
English ?
Changes interface language to English
Press ENTER to select English
language or to see the next language
French ?
Changes interface language to French. Note: Results obtained using French language will be based on SRV­P036 standard.
Press ENTER to select French
language or to see the next language
4 DOWNLOADING
The AUTOSTOP™ Mini Plus can hold 100 tests numbered one to hundred. Test results stored in Mini Plus can be downloaded to a PC using a USB cable, or via Bluetooth interface. To download the tests, a datalogger software needs to installed on the PC. The datalogger software can be installed from the provided CD or can be downloaded from the Internet.
4.1 Systems Requirements
To use the datalogger software, the PC must meet the following requirements:
Operating System: Windows 2000 or later  Disk Space: 10 MB of free hard disk space
4.2 Installing the Data Logger Software From CD
To install the datalogger software from the provided CD, perform the following steps:
1. Insert the Mini Plus Data logger Software CD into your disk drive.
2. Go to My Computer and select your CD-Rom drive (usually D:\ or E:\)
3. Select installation file “setup.exe” and run it.
4. Follow Setup prompts. Make sure you run the application with administrator level privileges.
4.3 Installing the Data Logger Software From Internet
The latest version of the AUTOSTOP™ Mini Plus datalogger software can be freely obtained from the Internet by opening the following URL:
http://autotest.net.au/ (Select ‘All products’ then select AutoStop Mini Plus)
When the above link opens, select ‘Datalogger Software’ link under ‘Downloads’. Then simply download and run the installation file.
4.4 Downloading Tests using the Data Logger Software
There are a couple of ways of downloading data from Mini Plus. The data can be downloaded via USB or Bluetooth. Once the datalogger software has been installed, run the software and follow the downloading instructions given below.
AutoStop Mini Plus User Manual v2.014 Page 13
4.4.1 Downloading via USB
Once the Data Logger software is installed, run the Data Logger software and connect the Brake Meter to the PC via the supplied USB cable.
Once the USB cable is connected to the PC, switch ON the Brake Meter by pressing the ON/OFF key. When the Brake Meter is switched ON, the PC will recognise the Brake Meter device and will search for the USB drivers.
Open device manage to install the USB drivers. The device manager can be accessed by
typing ‘devmgmt.msc’ in the Run Window. The Run Window can be accessed by
pressing + R from the keyboard. Make sure you have administrator level privileges when accessing Device Manager.
Select AutoStop MiniPlus in the device manager (under Other devices) and right click on it. Select “Update driver/software”.
USB
AutoStop Mini Plus User Manual v2.014 Page 14
Select “Browse my computer for driver software” to specify the location where the drivers
are located.
When the browse window is shown, select the USB driver folder located in the directory where the AutoStop Mini+ datalogger software is installed. On a 64-bit operating system, the default location where USB drivers are likely to be found is at C:\Program Files
(x86)\AutoTest\AutoStop Mini+ Data Logger\USB Drivers. On a 32-bit system, the USB
driver’s folder would be at C:\Program Files\AutoTest\AutoStop Mini+ Data Logger\USB
Drivers”.
AutoStop Mini Plus User Manual v2.014 Page 15
If the Windows displays the following warning message, select “Install this driver software anyway”.
AutoStop Mini Plus User Manual v2.014 Page 16
If Windows prompts the following dialogue box, select “Install” to install drivers.
When Windows has completed installing the drivers for the USB interface, the following window will appear. Notice the COM port number displayed on the titlebar. The COM port will be used when downloading data from the meter using the datalogger software.
AutoStop Mini Plus User Manual v2.014 Page 17
Once the USB drivers have been installed, Windows will diplay the following pop-up message each time the brake meter is connected to the PC via USB interface.
To verify the installation of the USB driver, locate “AutoStop MiniPlus” in the device
manager under “Ports (COM & LPT)”. If the device drivers are successfully installed,
there will be a COM port number written next to the device name. In the following example, the COM port number is “COM27”.
To download the results, open AutoStop Mini Plus datalogger software and click on Download” button.
AutoStop Mini Plus User Manual v2.014 Page 18
Select USB connection and then press Next.
Select the COM port of the USB connection. The COM port is the same port obtained earlier during the USB drivers installation process. Make sure the brake meter switched ON and it is connected to the PC via the USB cable. Press Next to continue.
AutoStop Mini Plus User Manual v2.014 Page 19
Once the connection has been connected successfully, the downloader will display a list of all tests currently stored on the meter.
Select the tests that need to be downloaded and then press Next. Datalogger software will automatically download all selected tests.
AutoStop Mini Plus User Manual v2.014 Page 20
Once the desired tests have been downloaded, press Finish to return to the main window and view test results.
AutoStop Mini Plus User Manual v2.014 Page 21
4.4.2 Downloading via Bluetooth
Before connecting the brake meter to the PC using the Bluetooth interface, make sure the PC supports Bluetooth connectivity.
Once the Data Logger software is installed, run the software on the PC and switch ON the brake meter by pressing the ON/OFF key.
When connecting the Brake Meter for the first time using the Bluetooth interface, user will need to configure the Bluetooth connection. To configure the Bluetooth connection, open your Bluetooth manager program on your PC and search for Mini+##### device, where '#####' is the serial number of the brake meter.
Note: the screenshots provided below many not be the same on your PC. For information regarding Bluetooth device pairing on your PC, please refer to the documentation of your Bluetooth Manager.
Select the device Mini+##### from the list of discovered Bluetooth devices and create pairing.
Bluetooth
AutoStop Mini Plus User Manual v2.014 Page 22
When prompted for the pairing code or pin number, enter “0000”.
Once the pairing is established, refresh device services and connect using Bluetooth serial port service.
AutoStop Mini Plus User Manual v2.014 Page 23
If the following message appears, note down the serial port and press Yes. The serial port will be later used by the datalogger software.
Users can also check the COM port of the Bluetooth device by viewing the status of the device.
AutoStop Mini Plus User Manual v2.014 Page 24
Once the Bluetooth connection is setup, the user can now download test results from Mini Plus using the Bluetooth interface. To download the results, open AutoStop Mini Plus datalogger software and click on “Download” button.
When the following connection window appears, select “Bluetooth” connection and press Next.
Select the COM port number of the Bluetooth connection connected with the brake meter. The COM port number is the same COM port obtained during the Bluetooth pairing process.
AutoStop Mini Plus User Manual v2.014 Page 25
Make sure the brake meter is ON. Press Next to continue. Once the connection is established, the datalogger software will acquire a list of all tests currently stored on the device.
Select the tests that need to be downloaded and press Next. Datalogger software will then download the selected tests. While downloading, the LCD screen of Mini Plus will display “Uploading 00%….”
AutoStop Mini Plus User Manual v2.014 Page 26
Once the desired tests have been downloaded, press Finish to return to the main window and view test results.
4.5 Using the Data Logger software
The Data logger will display all the saved tests and you can view the results of the particular test and view corresponding graph for each test.
The menu buttons displayed on the top bar can be used to perform the following operations:
1. Open: Allows opening a previously saved test file on the computer
2. Save: Allows the currently downloaded tests to be saved onto a file on the
computer
AutoStop Mini Plus User Manual v2.014 Page 27
3. Export: This option can be used to view and save the test result in Microsoft Excel
compatible format.
4. Print: this option can be used to print the test result. When printing the tests, the
following box will appear. User can select the printer from which the tests should be printed. In order print only a single or a few tests, enter the range of the tests to be printed out. Click on Print button to print.
5. Setting: this option can be used to view the test results in the units set by the Mini
Plus or select a different unit to view the test results.
6. About: to view information about Data logger.
AutoStop Mini Plus User Manual v2.014 Page 28
5 SPECIFICATION
5.1 Hardware Specifications
Measurement Range: -2.0 to +2.0g with accuracy 2.5% Temperature Range: -10 to +400C
5.2 Features
Determines tri-axial deceleration, forward as well as sideways deceleration (lane
change)
Calculates and displays SRV36 Simple 12 button operation via a tactile membrane pad Can be installed any where in the vehicle Self-aligning by identifying its orientation at the beginning of each test Lightweight (< 500grms) and compact (90 x 200 x 35mm) LCD display Adjustable display control Automatic start function Automatic shut-off after 15 minutes to preserve battery life (over 24 hours running
time)
Built-in integrity check Built-in real time clock Calibration is internationally traceable through NATA Calibration interval twenty-six months 12 months warranty Internet support hotline for diagnostics Comprehensive after-sales service and assistance EIA RS-232c Bluetooth interface USB interface Memory storage: Ninety tests PC down load capability and graph 16 x 1 character LCD display
AutoStop Mini Plus User Manual v2.014 Page 29
6 CALIBRATION PROCEDURE
The Mini Plus must be re-calibrated every two years. The reason for this is to maintain creditability in tests and acceptance of data according to international standards. Each time the unit is turned on; the LCD will show the date that the re-calibration is due. At the time the unit is due for re-calibration, the LCD screen will show: “Calibration Due! Please contact your vendor for re-calibration”, and further testing will be disabled. There are two ways of calibrating the Brake Meter - either return the AutoStop Mini Plus to your local distributor or by returning the Brake Meter to Auto Test Products (See Section 6.1).
6.1 Return of AutoStop Mini Plus for Calibration
6.1.1 Packaging
Please remember that you are shipping an electronic instrument. Bubble pack or foam should surround the Mini Plus and should be inserted into a sturdy cardboard box.
6.1.2 Shipping Labelling - A label noting “Electronic Device - Fragile” should be placed on the box. Freight Carrier - Container should be sent “Freight Prepaid”. Auto Test Products has no
preference on freight carriers. However, we prefer that companies such as TNT, IPEC, UPS, or Federal Express forward units, if a prompt delivery is required. Ship to: The Service Department, Auto Test Products Pty Ltd, 279 Normanby Road, Port Melbourne, VIC 3207, Australia. Phone: (+61 3) 9647 9797, or to your nearest service distributor.
6.1.3 Documentation
A copy of the purchase order for re-calibration and a packing slip must be included with the shipment. It should note the Purchase Order Number, Date, Serial Number and the address where the unit should be returned.
7 TROUBLESHOOTING
Problem
Potential Cause and Action Necessary
Mini Plus will not turn on
Internal electronics have failed - return unit for servicing.
Mini Plus not recording keypad input
Keypad damaged- return unit for servicing.
Mini Plus turns itself off during use
Battery flat-battery needs to be recharged. Mini Plus won’t run tests
Calibration due - return unit for calibration.
Mini Plus displays Clock failed
The in-built clock has failed. It might be an electronic fault, or the unit needs to be recalibrated.
Mini Plus displays Error
The test was not carried out correctly; repeat the test.
AutoStop Mini Plus User Manual v2.014 Page 30
8 WARRANTY
AutoTest Products Pty Ltd or any Authorised AutoTest Service Centre warrants this product against defects in material and workmanship for a period of 12 months from the original date of purchase. This warranty applies only to products and components supplied by AutoTest Products which can be identified by the trade name or logo affixed to them or by other documents. AutoTest Products does not warrant any products not supplied by AutoTest Products.
During the warranty period, AutoTest Products or any Authorised Service Centre will repair (or at its option replace) any defective component(s) without charge for parts or labour, provided the product is returned freight prepaid to an authorised AutoTest Service Centre. Transit insurance and return freight will be at the owner’s expense.
In order to obtain calibration, warranty or non-warranty service, ship the product, freight and insurance prepaid go to your nearest AutoTest Service Centre. Attach to the product your name, address, contact phone numbers, description of the problem and if a warranty claim, proof of purchase (dated sales receipt or invoice).
AutoTest Products or any Authorised AutoTest Service Centre reserves the right to refuse warranty repair if accident, abuse, misuse or misapplication has damaged the product. In transit or as a result of service or modification by other than an Authorised Service Centre, nor are any other warranties expressed or implied, including any regarding merchantability or fitness for any other particular purpose.
AutoTest Products or any Authorised Service Centre is not responsible for incidental or consequential damages resulting from the breach of any express or implied warranty, including damage to property and, to the extent permitted by law, damages for personal injury.
AutoStop Mini Plus User Manual v2.014 Page 31
9 AUTHORISED SERVICE AGENTS:
AUSTRALIA
AutoTest Products 279 Normanby Rd, Port Melbourne, VIC, 3207 PH: (+61) 3 9647 9797
CHINA
Itach Autotech Corp Room 703 Building A,Guo Run Commercial Plaza, No.46 West,. Feng Tai District, Beijing 100073 PH: (+_10) 8365 9442
DENMARK
BM Autoteknik A/S Erhvervsparken 7, 9632 Moldrup, PH: (+ 45) 8669 2022
FRANCE
Actia Muller Services Rue Des Tourneballets, Luce, PH: (+332) 3733 3536
FRENCH POLYNESIA
Cogicat snc. 51 Rue Des Remparts Prolongee, B.P 2828, Papeete, TAHITI, 98 713 PH: (+ 6) 8942 8175
HOLLAND
Stertil B.V Stokvis Service, Westkern 3, 9288 CA Kootstertille PH: (+315) 1258 0333
MACEDONIA
Velmar d.o.o. Gjorce Petrov 10, 1000 Skopje, Makedonija. PH: (+389) 2204 0288
MALASIA
Tritech Safety Sdn Bdn No38, 2nd Floor, Jalan Pandan Indah, Kawasan Industri Ampang Tambahan, 68000 Ampang, Selangor D.E. PH: (+603) 4291 0988
NEW ZEALAND
Brake & Transmission NZ 21-27 Omega St., Albany, Auckland PH: (+ 64) 9414 3205
SOUTH AFRICA
Brakecore Supply Co 5 Oosthuise St, Ermelo, 2350. PH: (+271) 7819 3412
UNITED KINGDOM
Tecalemit Garage Equip. Co. Ltd Unit 2,Eagle Road, Langage Bus Pk., Plympton, Plymoth, Devon, PL7 5JY PH: (+017) 5221 9150
UNITED STATES OF AMERICA
Commercial Vehicle Consultants Inc. 144 Overlook Ave, Staten Island, NEW YORK, 10304. PH: (+171) 8980 3651
NOTES:
AUTOTEST Products Pty Ltd. 279 Normanby Road, Port Melbourne, Victoria, Australia, 3207.
General Enquiry Phone: (+61) 3 9647 9797 Sales Enquiry Phone: (+61) 3 9647 9706. Service Enquiry Phone: (+61) 3 9647 9707 Shipping Enquiry Phone: (+61) 3 9647 9762 Fax: (+61) 3 9646 3427. Shipping Address: 275 Normanby Rd. Port Melbourne Vic 3207
For general enquiries, please contact info@autotest.net.au For sales enquiries, please contact: sales@autotest.net.au For service enquiries, please contact: service@autotest.net.au
AUTO
TEST
Products Pty Ltd
279 Normanby Road, Port Melbourne. VIC 3207 Australia Phone: (+61 3) 9647 9797 Sales:(+61 3) 9647 9706 Service:(+61 3) 9647 9707 Fax: (+61 3) 9646 3427 Email:service@autotest.net.au sales@autotest.net.au
info@autotest.net.au www.autotest.net.au
Loading...