
DRW160733AC
INDUCTIVE PROXIMITY SENSOR
PS SERIES
I N S T R U C T I O N M A N U A L
[PS08] [PS12] [PS50]
Thank you very much for selecting Autonics products.
For your safety, please read the following before using.
Safety Considerations
Please observe all safety considerations for safe and proper product operation to avoid hazards.
※
※
symbol represents caution due to special circumstances in which hazards may occur.
Warning Failure to follow these instructions may result in serious injury or death.
Caution
Failure to follow these instructions may result in personal injury or product damage.
Item
Main circuit
Main circuit
Shape
Dimension
10kΩ
10kΩ
2.5
ND
Power supply
Sensing distance
※
1
※
1
Sensing position
Output
Brown
Load
Black
Blue
Brown
Black
Load
Blue
No mark Standard type
U Upper sensing type
N NPN Normally Open (N.O.)
N2 NPN Normally Closed (N.C.)
P PNP Normally Open (N.O.)
P2 PNP Normally Closed (N.C.)
D 12-24VDC
Number Sensing distance (unit: mm)
Number A side length of sensing side (unit: mm)
S Square
P Inductive proximity sensor
+V
0V
+V
0V
Sensing
target
Load
(Brown-Black)
Output voltage
(Black-Blue)
Operation
Indicator
(Red LED)
Sensing
target
Load
(Black-Blue)
Output voltage
(Black-Blue)
Operation
Indicator
(Red LED)
Presence
Nothing
Operation
Return
H
L
ON
OFF
Presence
Nothing
Operation
Return
H
L
ON
OFF
N.O. N.C.
N.O. N.C.
Warning
1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic
loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety
equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in fi re, personal injury, or economic loss.
2. Do not disassemble or modify the unit.
Failure to follow this instruction may result in fi re.
3. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in fi re.
4. Check 'Connections' before wiring.
Failure to follow this instruction may result in fi re.
Caution
1. Use the unit within the rated specifi cations.
Failure to follow this instruction may result in fi re or product damage.
2. Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in electric shock or fi re.
3. Do not use the unit in the place where fl ammable/explosive/corrosive gas, humidity, direct sunlight, radiant heat, vibration,
impact, or salinity may be present.
Failure to follow this instruction may result in fi re or explosion.
4. Do not supply power without load.
Failure to follow this instruction may result in fi re or product damage.
Ordering Information
P S 08
Control Output Diagram and Load Operation
NPN output type
PNP output type
※
1: For PS08 model, there is no zener diode.
The above specifi cations are subject to change and some models may be discontinued without notice.
※
Be sure to follow cautions written in the instruction manual and the technical descriptions (catalog, homepage).
※
Specifi cations Mutual-Interference and Infl uence By Surrounding Metals
PS08-2.5DN
Model
Sensing distance 2.5mm 4mm 30mm
Hysteresis Max. 20% of sensing distance Max. 10% of sensing distance
Standard sensing target 8×8×1mm (Iron) 12×12×1mm (Iron) 90×90×1mm (Iron)
Setting distance 0 to 1.7mm 0 to 2.8mm 0 to 21mm
Power supply
(Operating voltage)
Current consumption Max. 10mA
Response frequency
Residual voltage Max. 1.5V
Affection by Temp. Max. ±10% for sensing distance at ambient temperature 20℃
Control output Max. 100mA Max. 200mA
Insulation resistance Min. 50MΩ (at 500VDC megger)
Dielectric strength 1,500VAC 50/60Hz for 1 minute
Vibration 1mm amplitude at frequency of 10 to 55Hz in each of X, Y, Z directions for 2 hours
Shock 500m/s² (approx. 50G) in X, Y, Z directions for 3 times
Indicator Operation indicator: Red LED
Ambient temperature
Environ
-ment
Ambient humidity 35 to 95%RH, Storage: 35 to 95%RH
Protection circuit Reverse polarity protection, Surge protection circuit, Overcurrent protection
Protection structure IP67 (IEC standard)
2
※
Cable
Material
Approval
3
※
Weight
※
1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard
sensing target, 1/2 of the sensing distance for the distance.
※
2: Do not pull the Ø4mm cable with a tensile strength of 30N or over and the Ø5mm cable with a tensile strength of 50N or over.
It may result in fi re due to the broken wire. When extending wire, use AWG22 cable or over within 200m.
※
3: The weight includes packaging. The weight in parentheses in for unit only.
※Environment resistance is rated at no freezing or condensation.
Dimensions
PS08-2.5DP
PS08-2.5DN2
PS08-2.5DP2
12-24VDC
(10-30VDCᜡ)
1
※
1,000Hz 500Hz 50Hz
-25 to 70℃, Storage: -30 to 80
Ø2.5mm, 3-wire, 1m Ø4mm, 3-wire, 2m Ø5mm, 3-wire, 2m
AWG28, Core diameter: 0.08mm,
Number of cores: 19, Insulator
diameter: Ø0.9mm
Case: Polycarbonate
General cable (gray):
Polyvinyl chloride (PVC)
Approx. 30g (approx. 16g) Approx. 77g (approx. 62g) Approx. 265g (approx. 220g)
PS08
Standard type Upper sensing type
18.5
8
26
8
8
Mounting hole cut-out
※
PS12
15.25 14.5
12
12
10.8
※
PS50
53
45
Ø3.2
Ø2.5, 1m
Operation
indicator (red)
5.3
11.5
M3×0.5 Tap DP: Min. 8
Ø2.4 DP: Min. 3
When installing the product, tighten the screw with a tightening torque of
45
14.8
Operation
indicator(red)
When installing the product, tighten the screw with a tightening torque of
55.5
53
45
Operation indicator(red)
ᜡ
8
7.4
PS08-2.5DNU
PS08-2.5DPU
PS08-2.5DN2U
PS08-2.5DP2U
15.5
11.5
23
8
Ø4, 2m
Ø5, 2m
PS12-4DN
PS12-4DP
PS12-4DN2
℃
AWG22, Core diameter: 0.08mm, Number of cores: 60,
Insulator diameter: Ø1.25mm
Case: Heat-resistant ABS
General cable (gray):
Polyvinyl chloride (PVC)
PS12-4DNU
PS12-4DPU
PS12-4DN2U
Bracket
Ø3.2
Ø2.5, 1m
Operation
indicator (red)
5.3
2.3
※
Installing bolts must be a M3×12mm truss bolt and
tightening strength should be max. 0.49N∙m.
If installing this unit not as this method, it may cause
damage to the functions.
0.4
8.8
2
0.49N∙m.
Bracket
29
21
6
2-3.5
0.98N∙m.
Ø50
35
16
PS50-30DN
PS50-30DN2
PS50-30DP
PS50-30DP2
Case: Polybutylene terephthalate
General cable (gray):
Polyvinyl chloride (PVC)
(unit: mm)
17.8
0.4
11.3
8.1
M3×12mm
For mounting at cutting hole
14.5
11.8
10.8
Ø3.2
0.8
Mutual-interference
When plural proximity sensors are mounted in a close row, malfunction of sensor may be caused due to mutual interference.
Therefore, be sure to provide a minimum distance between the two sensors, as below charts.
PS08
16
16
16
16
(Face to Face)
(Face to Face)
PS12 PS50
(Parallel)
24
24
180 130
(Parallel)
(Face to Face)
(Parallel)
(Face to Face)
(Parallel)
Infl uence by surrounding metals
When sensors are mounted on metallic panel, it must be prevented sensors from being affected by any metallic object except target.
Therefore, be sure to provide a minimum distance as a right picture.
PS08 PS50
PS12
18
8
15
15
8
8
5
8
Setting Distance
Target
Moving
direction
Sn:Sensing
distance
Sa:Setting distance
(a) (b)
● Sensing distance can be changed by the shape, size or material of the target.
Therefore please check the sensing distance like (a), then pass the target within range of setting distance(Sa).
● Setting distance(Sa)= Sensing distance(Sn) × 70%
E.g.)PS50-30DN
Setting distance(Sa)= 30mm × 0.7 = 21mm
Caution during Use
1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
2. 12-24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
3. Use the product, after 0.8 sec of supplying power.
4. Wire as short as possible and keep away from high voltage lines or power lines, to prevent surge and inductive noise.
Do not use near the equipment which generates strong magnetic force or high frequency noise (transceiver, etc.).
In case installing the product near the equipment which generates strong surge (motor, welding machine, etc.), use diode or varistor
to remove surge.
5. This unit may be used in the following environments.
Indoors (in the environment condition rated in 'Specifi cations')
①
Altitude max. 2,000m
②
Pollution degree 2
③
Installation category II
④
11.9
Major Products
Photoelectric Sensors Temperature Controllers
Fiber Optic Sensors Temperature/Humidity Transducers
Door Sensors SSRs/Power Controllers
Door Side Sensors Counters
Area Sensors Timers
Proximity Sensors Panel Meters
Pressure Sensors Tachometers/Pulse (Rate) Meters
Rotary Encoders Display Units
Connectors/Sockets Sensor Controllers
Switching Mode Power Supplies
Control Switches/Lamps/Buzzers
I/O Terminal Blocks & Cables
Stepper Motors/Drivers/Motion Controllers
Graphic/Logic Panels
Field Network Devices
Laser Marking System (Fiber, Co₂, Nd: YAG)
Laser Welding/Cutting System
(70% of Sn)
12
120
1212
Target
Sn
Moving
direction
Sa
http://www.autonics.com
HEADQUARTERS:
18, Bansong-ro 513 beon-gil, Haeundae-gu, Busan,
South Korea, 48002
TEL: 82-51-519-3232
E-mail: sales@autonics.com
DRW160733AC
(unit: mm)
5050
Metal