PR Series
PR Series
Cylindrical Type Proximity Sensor
Features
●
Improved the noise immunity with dedicated IC
● Built-in reverse polarity protection circuit (DC 3-wire type)
● Built-in surge protection circuit
● Built-in output short over current protection circuit (DC type)
● Long life cycle and high reliability, and simple operation
● IP67 protection structure (IEC standard)
● Replaceable for micro switches and limit switches
Please read “Safety Considerations”
in the instruction manual before using.
Specifications
● DC 2-wire type
PRT08-1.5DO
Model
Diameter of
sensing side
Sensing distance 1.5mm 2mm 2mm 4mm 5mm 8mm 10mm 15mm
Installation Shield (ush)
Hysteresis Max. 10% of sensing distance
Standard sensing
target
Setting distance 0 to 1.05mm 0 to 1.4mm 0 to 1.4mm 0 to 2.8mm 0 to 3.5mm 0 to 5.6mm 0 to 7mm 0 to 10.5mm
Power supply
(operating voltage)
Leakage current Max. 0.6mA
Response
frequency
Residual voltage
Aection by Temp.
Control output 2 to 100mA
Insulation resistance Over 50MΩ (at 500VDC megger)
Dielectric strength 1,500VAC 50/60Hz for 1 min
Vibration 1mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours
Shock 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times
Indicator Operation indicator: Red LED
Environ-
ment
Protection circuit Surge protection circuit Surge protection circuit, output short over current protection circuit
Protection structure IP67 (IEC standard)
Cable
Material
Approval
Weight
※
※
※
※
※
1
※
Ambient
temperature
Ambient
humidity
3
※
1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard
sensing target, 1/2 of the sensing distance for the distance.
2: Before using non-polarity type, check the condition of connected device because residual voltage is 5V.
3: The weight includes packaging. The weight in parenthesis in for unit only.
The ' ' of model name is for power type. 'D' is 12-24VDC, 'X' is non-polarity 12-24VDC.
Environment resistance is rated at no freezing or condensation.
PRT08-1.5DC
PRT08-1.5DO-V
8mm 12mm 18mm 30mm
8×8×1mm
(iron)
12- 24VDCᜡ
(10 -30VDCᜡ)
1.5kHz 1kHz 1.5kHz 500Hz 350Hz 400Hz 200Hz
2
※
Max. 3.5V (non-polarity type is max. 5V)
Max. ±10% for sensing distance at ambient temperature 20℃ (for PRT08 Series: ±20% max.)
-25 to 70℃, storage: -30 to 80
35 to 95% RH, storage: 35 to 95% RH
Ø3.5mm, 2-wire, 2m
(AWG24, Core diameter:
0.08mm, Number of cores: 40,
Insulator diameter: Ø1mm)
Case/Nut: Nickel plated brass, Washer: Nickel plated iron, Sensing surface: Polybutylene terephthalate,
Standard cable (black): Polyvinyl chloride (PVC), Oil resistant cable (gray): Oil resistant polyvinyl chloride (PVC)
ᜢ
Approx. 64g (approx. 52g) Approx.84g (approx. 72g) Approx.122g (approx. 110g) Approx.207g (approx. 170g)
PRT08-2DO
PRT08-2DC
Non-shield
(non-ush)
PRT12-2DO
PRT12-2DC
Shield (ush)
12×12×1mm
(iron)
℃
Ø4mm, 2-wire, 2m Ø5mm, 2-wire, 2m
AWG22, Core diameter: 0.08mm, Number of cores: 60, Insulator diameter: Ø1.25mm
PRT12-4DO
PRT12-4DC
Non-shield
(non-ush)
※
When the model name is X, it is non-polarity model.
PRT18-5DO
PRT18-5DC
Shield (ush)
18×18×1mm
(iron)
PRT18-8DO
PRT18-8DC
Non-shield
(non-ush)
25×25×1mm
(iron)
PRT30-10DO
PRT30-10DC
PRT30-10DO-V
Shield (ush)
30×30×1mm
(iron)
PRT30-15DO
PRT30-15DC
Non-shield
(non-ush)
45×45×1mm
(iron)
F-70 F-71
Cylindrical Type
Specifications
● DC 3-wire type
PR12-4DN
PR12-4DP
PR12-4DN2
PR12-4DP2
PRS12-4DN
PRS12-4DP
PRS12-4DN2
PRS12-4DP2
PRL12-4DN
PRL12-4DP
Non-shield
(non-ush)
PR18-5DN
PR18-5DP
PR18-5DN2
PR18-5DP2
PR18-5DN-V
PRL18-5DN
PRL18-5DP
PRL18-5DN2
PRL18-5DP2
Shield (ush)
18×18×1mm
(iron)
PR18-8DN
PR18-8DP
PR18-8DN2
PR18-8DP2
PRL18-8DN
PRL18-8DP
PRL18-8DN2
PRL18-8DP2
Non-shield
(non-ush)
25×25×1mm
(iron)
PR: Approx. 122g (approx. 110g)
PRL: Approx. 142g (approx. 130g)
PR30-10DN
PR30-10DP
PR30-10DN2
PR30-10DP2
PRL30-10DN
PRL30-10DP
PRL30-10DN2
PRL30-10DP2
Shield (ush)
30×30×1mm
(iron)
PR30-15DN
PR30-15DP
PR30-15DN2
PR30-15DP2
PRL30-15DN
PRL30-15DP
PRL30-15DN2
PRL30-15DP2
Non-shield
(non-ush)
45×45×1mm
(iron)
PR: Approx. 207g (approx. 170g)
PRL: Approx. 247g (approx. 210g)
Model
Diameter of
sensing side
PR08-1.5DN
PR08-1.5DP
PR08-1.5DN2
PR08-1.5DP2
PRL08-1.5DN
PRL08-1.5DP
PRL08-1.5DN2
PRL08-1.5DP2
8mm 12mm 18mm 30mm
PR08-2DN
PR08-2DP
PR08-2DN2
PR08-2DP2
PRL08-2DN
PRL08-2DP
PRL08-2DN2
PRL08-2DP2
PR12-2DN
PR12-2DP
PR12-2DN2
PR12-2DP2
PRS12-2DN
PRS12-2DP
PRS12-2DN2
PRS12-2DP2
Sensing distance 1.5mm 2mm 2mm 4mm 5mm 8mm 10mm 15mm
Installation Shield (ush)
Non-shield
(non-ush)
Shield (ush)
Hysteresis Max. 10% of sensing distance
Standard sensing
target
8×8×1mm (iron) 12×12×1mm (iron)
Setting distance 0 to 1.05mm 0 to 1.4mm 0 to 1.4mm 0 to 2.8mm 0 to 3.5mm 0 to 5.6mm 0 to 7mm 0 to 10.5mm
Power supply
(operation voltage)
Current
consumption
Response
frequency
1
※
12 -24VDCᜡ
(10- 30VDCᜡ)
Max. 10mA
1.5kHz 1kHz 1.5kHz 500Hz 350Hz 400Hz 200Hz
Residual voltage Max. 2.0V Max. 1.5V
Aection by Temp.
Max. ±10% for sensing distance at ambient temperature 20℃ , PR08 Series: max. ±20%
Control output Max. 200mA
Insulation resistance Over 50MΩ (at 500VDC megger)
Dielectric strength 1,500VAC 50/60Hz for 1 min
Vibration 1mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours
Shock 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times
Indicator Operation indicator: Red LED
Environ-
ment
Ambient
temperature
Ambient
humidity
-25 to 70℃, storage: -30 to 80
℃
35 to 95%RH, storage: 35 to 95%RH
Protection circuit Surge protection circuit, Reverse polarity protection circuit, output short over current protection circuit
Protection structure IP67 (IEC standard)
Material
Cable
Approval
2
※
Weight
※
1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard
sensing target, 1/2 of the sensing distance for the distance.
※
2: The weight includes packaging. The weight in parenthesis in for unit only.
※
Environment resistance is rated at no freezing or condensation.
Case/Nut: Nickel plated brass, Washer: Nickel plated iron, Sensing surface: Polybutylene terephthalate,
Standard cable (black): Polyvinyl chloride (PVC), Oil resistant cable (gray): Oil resistant polyvinyl chloride (PVC)
Ø3.5mm, 3-wire, 2m
(AWG24, Core diameter: 0.08mm,
Number of cores: 40,
Insulator diameter: Ø1mm)
Ø4mm, 3-wire, 2m Ø5mm, 3-wire, 2m
AWG22, Core diameter: 0.08mm, Number of cores: 60, Insulator diameter: Ø1.25mm
ᜢ
PR: Approx. 64g (approx. 52g)
PRL: Approx. 66g (approx. 54g)
PR: Approx. 84g (approx. 72g)
PRS: Approx. 82g (approx. 70g)
PRL: Approx. 88g (approx. 76g)
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(A)
Photoelectric
Sensors
(B)
Fiber Optic
Sensors
(C)
LiDAR
(D)
Door/Area
Sensors
(E)
Vision
Sensors
(F)
Proximity
Sensors
(G)
Pressure
Sensors
(H)
Rotary
Encoders
(I)
Connectors/
Connector Cables/
Sensor Distribution
Boxes/ Sockets
PR Series
Specifications
● AC 2-wire type
Model
Diameter of
sensing side
Sensing distance 2mm 4mm 5mm 8mm 10mm 15mm
Installation Shield (ush)
Hysteresis Max. 10% of sensing distance
Standard sensing
target
Setting distance 0 to 1.4mm 0 to 2.8mm 0 to 3.5mm 0 to 5.6mm 0 to 7mm 0 to 10.5mm
Power supply
(operation voltage)
Leakage current Max. 2.5mA
Response frequency
Residual voltage Max. 10V
Aection by Temp.
Control output 5 to 150mA 5 to 200mA
Insulation resistance Over 50MΩ (at 500VDC megger)
Dielectric strength 2,500VAC 50/60Hz for 1 min
Vibration 1mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours
Shock 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times
Indicator Operation indicator: Red LED
Ambient
Environ-
ment
Protection circuit Surge protection circuit
Protection structure IP67 (IEC standard)
Cable
Insulation type
Material
Approval
Weight
※
※
※
temperature
Ambient
humidity
2
※
1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard
sensing target, 1/2 of the sensing distance for the distance.
2: The weight includes packaging. The weight in parenthesis in for unit only.
Environment resistance is rated at no freezing or condensation.
PR12-2AO
PR12-2AC
12mm 18mm 30mm
12×12×1mm (iron) 18×18×1mm (iron) 25×25×1mm (iron) 30×30×1mm (iron) 45×45×1mm (iron)
100- 240VACᜠ
(85- 264VACᜠ)
1
※
20 Hz
Max. ±10% for sensing distance at ambient temperature 20℃
-25 to 70℃, storage: -30 to 80
35 to 95%RH, storage: 35 to 95%RH
Ø4mm, 2-wire, 2m Ø5mm, 2-wire, 2m
AWG22, Core diameter: 0.08mm, Number of cores: 60, Insulator diameter: Ø1.25mm
Double insulation or reinforced insulation
(Mark: , dielectric strength between the measuring input part and the power part: 1kV)
Case/Nut: Nickel plated brass, Washer: Nickel plated iron, Sensing surface: Polybutylene terephthalate,
Standard cable (black): Polyvinyl chloride (PVC)
Approx. 84g (approx. 66g)
PR12-4AO
PR12-4AC
Non-shield
(non-ush)
PR18-5AO
PR18-5AC
PRL18-5AO
PRL18-5AC
Shield (ush)
℃
PR: Approx. 130g (approx. 118g)
PRL: Approx. 142g (approx. 130g)
PR18-8AO
PR18-8AC
PRL18-8AO
PRL18-8AC
Non-shield
(non-ush)
PR30-10AO
PR30-10AC
PRL30-10AO
PRL30-10AC
Shield (ush)
PR: Approx. 207g (approx. 170g)
PRL: Approx. 245g (approx. 208g)
PR30-15AO
PR30-15AC
PRL30-15AO
PRL30-15AC
Non-shield
(non-ush)
F-72 F-73