Features
Long sensing distance
(1.5 to 2 times longer sensing distance guaranteed compared
to existing models)
Improved the noise immunity with dedicated IC
Built-in surge protection, reverse polarity protection,
output short over current protection circuit
Long life cycle and high reliability, and simple operation
Red LED operation indicator
IP67 protection structure (IEC standard)
Replaceable for micro switches and limit switches
Strain relief cables
:improvedexuralstrengthofcableconnectingcomponent
(except for PRDWT08- DO- )
Please read “Safety Considerations”
in the instruction manual before using.
Specifications
● DC 2-wire type
Model
Diameter of sensing side
Sensing distance 2mm 4mm 4mm 8mm 7mm 14mm 15mm 25mm
Installation Shield(ush)
Hysteresis
Standard sensing
target
Setting distance 0 to 1.4mm 0 to 2.8mm 0 to 2.8mm 0 to 5.6mm 0 to 4.9mm 0 to 9.8mm 0 to 10.5mm 0 to 17.5mm
Power supply
(operating voltage)
Leakage current Max. 0.8mA Max. 0.6mA
Response frequency
Residual voltage
AectionbyTemp.
Control output 2 to 100mA
※
1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard
sensing target, 1/2 of the sensing distance for the distance.
※
2: Before using non-polarity type, check the condition of connected device because residual voltage is 5V.
※
The ' ' of model name is for power type. 'D' is 12-24VDC, 'X' is non-polarity 12-24VDC.
※
The last 'V' of model name is for the model with oil-resistance reinforced cable.
※
※
When the model name is X, it is non-polarity model.
PRDWT08-2DO
PRDWT08-2DC
PRDWT08-2DO-I
PRDWT08-2DC-I
PRDWT08-2DO-V
PRDWT08-2DC-V
PRDWT08-2DO-IV
PRDWT08-2DC-IV
8mm 12mm 18mm 30mm
Max. 15% of sensing
distance
8×8×1mm
(iron)
12-24VDCᜡ
(10-30VDCᜡ )
※
1
1kHz 800Hz 450Hz 400Hz 250Hz 200Hz 100Hz
2
Max. 3.5V (non-polarity type is max. 5V)
Max. ±15% for sensing
distance at ambient
temperature 20℃
PRDWT08-4DO
PRDWT08-4DC
PRDWT08-4DO-I
PRDWT08-4DC-I
PRDWT08-4DO-V
PRDWT08-4DC-V
PRDWT08-4DO-IV
PRDWT08-4DC-IV
Non-Shield
(non-ush)
12×12×1mm
(iron)
PRDWT12-4 D O
PRDWT12-4 D C
PRDWT12-4 D O-I
PRDWT12-4 D C-I
PRDWT12-4 D O-IV
PRDWT12-4 D C-IV
PRDWT12-4DO-V
PRDWT12-4DC-V
Shield
(ush)
Max. 10% of sensing distance
12×12×1mm
(iron)
Max. ±10% for sensing distance at ambient temperature 20℃
PRDWT12-8 D O
PRDWT12-8 D C
PRDWT12-8 D O-I
PRDWT12-8 D C-I
PRDWT12-8 D O-IV
PRDWT12-8 D C-IV
PRDWT12-8DO-V
PRDWT12-8DC-V
Non-Shield
(non-ush)
25×25×1mm
(iron)
PRDWT18-7 D O
PRDWT18-7 D C
PRDWT18-7 D O-I
PRDWT18-7 D C-I
PRDWT18-7 D O-IV
PRDWT18-7 D C-IV
PRDWT18-7DO-V
PRDWT18-7DC-V
PRDWLT18-7DO-IV
Shield
(ush)
20×20×1mm
(iron)
PRDWT18-14 D O
PRDWT18-14 D C
PRDWT18-14 D O-I
PRDWT18-14 D C-I
PRDWT18-14 D O-IV
PRDWT18-14 D C-IV
PRDWT18-14DO-V
PRDWT18-14DC-V
Non-Shield
(non-ush)
40×40×1mm
(iron)
PRDWT30-15 D O
PRDWT30-15 D C
PRDWT30-15 D O-I
PRDWT30-15DC-I
PRDWT30-15 D O-IV
PRDWT30-15DC-IV
PRDWT30-15DO-V
PRDWT30-15DC-V
Shield
(ush)
45×45×1mm
(iron)
PRDWT30-25DO
PRDWT30-25DC
PRDWT30-25DO-I
PRDWT30-25DC-I
PRDWT30-25DO-IV
PRDWT30-25DC-IV
PRDWT30-25DO-V
PRDWT30-25DC-V
Non-Shield
(non-ush)
75×75×1mm
(iron)
F-108
Cylindrical, Long Sensing Distance, Cable Connector Type
● DC 2-wire type
Model
PRDWT08-2DO
PRDWT08-2DC
PRDWT08-2DO-I
PRDWT08-2DC-I
PRDWT08-2DO-V
PRDWT08-2DC-V
PRDWT08-2DO-IV
PRDWT08-2DC-IV
PRDWT08-4DO
PRDWT08-4DC
PRDWT08-4DO-I
PRDWT08-4DC-I
PRDWT08-4DO-V
PRDWT08-4DC-V
PRDWT08-4DO-IV
PRDWT08-4DC-IV
PRDWT12-4 D O
PRDWT12-4 D C
PRDWT12-4 D O-I
PRDWT12-4 D C-I
PRDWT12-4 D O-IV
PRDWT12-4 D C-IV
PRDWT12-4DO-V
PRDWT12-4DC-V
PRDWT12-8 D O
PRDWT12-8 D C
PRDWT12-8 D O-I
PRDWT12-8 D C-I
PRDWT12-8 D O-IV
PRDWT12-8 D C-IV
PRDWT12-8DO-V
PRDWT12-8DC-V
※
When the model name is X, it is non-polarity model.
PRDWT18-7 D O
PRDWT18-7 D C
PRDWT18-7 D O-I
PRDWT18-7 D C-I
PRDWT18-7 D O-IV
PRDWT18-7 D C-IV
PRDWT18-7DO-V
PRDWT18-7DC-V
PRDWLT18-7DO-IV
PRDWT18-14 D O
PRDWT18-14 D C
PRDWT18-14 D O-I
PRDWT18-14 D C-I
PRDWT18-14 D O-IV
PRDWT18-14 D C-IV
PRDWT18-14DO-V
PRDWT18-14DC-V
PRDWT30-15 D O
PRDWT30-15 D C
PRDWT30-15 D O-I
PRDWT30-15DC-I
PRDWT30-15 D O-IV
PRDWT30-15DC-IV
PRDWT30-15DO-V
PRDWT30-15DC-V
Insulation resistance Over50MΩ(at500VDCmegger)
Dielectric strength 1,500VAC 50/60Hz for 1 min
Vibration 1mm amplitude at frequency 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours
Shock 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times
Indicator Operation indicator: Red LED
Ambient temp. -25 to 70℃, storage: -30 to 80
Environment
Ambient humi. 35 to 95% RH, storage: 35 to 95% RH
℃
Protection circuit Surge protection circuit, reverse polarity protection circuit, output short over current protection circuit
Case/Nut: Nickel plated brass (case of PRDT08: SUS303), Washer: Nickel plated iron,
Material
Sensing surface: Polybutylene terephthalate, Standard cable (black): Polyvinyl chloride (PVC),
Oil resistant cable (gray): Oil resistant polyvinyl chloride (PVC)
※
Cable
Approval
Ø3.5mm, 2-wire, 300mm,
M12 connector
3
(AWG24,
core diameter: 0.08mm,
number of cores: 40,
insulator diameter: Ø1.0mm)
ᜢ
Ø4mm, 2-wire, 300mm,
M12 connector
(AWG22,
core diameter: 0.08mm,
number of cores: 60,
insulator diameter: Ø1.25mm)
Ø5mm, 2-wire, 300mm, M12 connector
(AWG22, core diameter: 0.08mm, number of cores: 60,
insulator diameter: Ø1.25mm)
Protection structure IP67 (IEC standard)
PRDWT
Weight
※
4
PRDWLT
※
3: Do not pull the Ø3.5mm cable with a tensile strength of 25N, the Ø4mm cable with a tensile strength of 30N or over and the
Approx. 28g
(approx. 20g)
- - -
Approx. 44g
(approx. 32g)
Approx. 42g
(approx. 30g)
Approx. 80g
(approx. 62g)
Approx. 110g
(approx. 92g)
Approx. 75g
(approx. 57g)
Approx. 140g
(approx. 130g)
- - -
Ø5mm cable with a tensile strength of 50N or over.
Itmayresultinreduetothebrokenwire.Whenextendingwire,useAWG22cableoroverwithin200m.
※
4: The weight includes packaging. The weight in parenthesis in for unit only.
※
The ' ' of model name is for power type. 'D' is 12-24VDC, 'X' is non-polarity 12-24VDC.
※
The last 'V' of model name is for the model with oil-resistance reinforced cable.
※
Environment resistance is rated at no freezing or condensation.
PRDWT30-25DO
PRDWT30-25DC
PRDWT30-25DO-I
PRDWT30-25DC-I
PRDWT30-25DO-IV
PRDWT30-25DC-IV
PRDWT30-25DO-V
PRDWT30-25DC-V
Approx. 145g
(approx. 108g)
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(A)
Photoelectric
Sensors
(B)
Fiber Optic
Sensors
(C)
LiDAR
(D)
Door/Area
Sensors
(E)
Vision
Sensors
(F)
Proximity
Sensors
(G)
Pressure
Sensors
(H)
Rotary
Encoders
(I)
Connectors/
Connector Cables/
Sensor Distribution
Boxes/ Sockets
F-109
PRDW Series
● DC 3-wire type
PRDW12-4DN
PRDW12-4DP
PRDW12-4DN2
PRDW12-4DP2
PRDW12-4DN-V
Model
Diameter of sensing side
Sensing distance
Installation
Hysteresis
Standard sensing
target
PRDW12-4DP-V
PRDW12-4DN2-V
PRDW12-4DP2-V
PRDWL12-4DN
PRDWL12-4DP
PRDWL12-4DN2
PRDWL12-4DP2
12mm 18mm 30mm
4mm 8mm 7mm 14mm 15mm 25mm
Shield
(ush)
Max. 10% of sensing distance
12×12×1mm ( iron) 25×25×1mm (iron) 20×20×1mm (iron) 40×40×1mm (iron) 45×45×1mm (iron) 75×75×1mm (iron)
Setting distance 0 to 2.8mm 0 to 5.6mm 0 to 4.9mm 0 to 9.8mm 0 to 10.5mm 0 to 17.5mm
Power supply
(operating voltage)
Leakage current
Response frequency
Residual voltage
AectionbyTemp.
Control output
Insulation resistance
Dielectric strength
Vibration
Shock
Indicator
Ambient temp.
Environment
Ambient humi.
12-24VDCᜡ
(10-30VDCᜡ )
Max. 10mA
※
1
500Hz 400Hz 300Hz 200Hz 100HZ 100Hz
Max. 1.5V
Max. ±10% for sensing distance at ambient temperature 20℃
200mA
Over50MΩ(at500VDCmegger)
1,500VAC 50/60Hz for 1 min
1mm amplitude at frequency 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours
500m/s² (approx. 50G) in each X, Y, Z direction for 3 times
Operation indicator: Red LED
-25 to 70℃, storage: -30 to 80
35 to 95%RH, storage: 35 to 95%RH
Protection circuit Surge protection circuit, reverse polarity protection circuit, output short over current protection circuit
Protection structure IP67 (IEC standard)
Material
Cable
※
2
Case/Nut: Nickel plated brass, Washer: Nickel plated iron, Sensing surface: Polybutylene terephthalate,
Standard cable (black): Polyvinyl chloride (PVC), Oil resistant cable (gray): Oil resistant polyvinyl chloride (PVC)
Ø4mm, 2-wire, 300mm, M12 connector
AWG22, Core diameter: 0.08mm, Number of cores: 60, Insulator diameter: Ø1.25mm
Approval
PRDW
Unit
weight
PRDWL
※
1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard
sensing target, 1/2 of the sensing distance for the distance.
※
2: Do not pull the Ø4mm cable with a tensile strength of 30N or over and the Ø5mm cable with a tensile strength of 50N or over.
Itmayresultinreduetothebrokenwire.Whenextendingwire,useAWG22cableoroverwithin200m.
※
The last 'V' of model name is for the model with oil-resistance reinforced cable.
※
Environment resistance is rated at no freezing or condensation.
Approx. 44g Approx. 42g Approx. 80g Approx. 75g Approx. 140g Approx. 145g
Approx. 64g Approx. 62g Approx. 110g Approx. 105g Approx. 180g Approx. 185g
PRDW12-8DN
PRDW12-8DP
PRDW12-8DN2
PRDW12-8DP2
PRDW12-8DN-V
PRDW12-8DP-V
PRDW12-8DN2-V
PRDW12-8DP2-V
PRDWL12-8DN
PRDWL12-8DP
PRDWL12-8DN2
PRDWL12-8DP2
Non-Shield
(non-ush)
℃
PRDW18-7DN
PRDW18-7DP
PRDW18-7DN2
PRDW18-7DP2
PRDW18-7DN-V
PRDW18-7DP-V
PRDW18-7DN2-V
PRDW18-7DP2-V
PRDWL18-7DN
PRDWL18-7DP
PRDWL18-7DN2
PRDWL18-7DP2
Shield
(ush)
Ø5mm,
3-wire
PRDW18-14DN
PRDW18-14DP
PRDW18-14DN2
PRDW18-14DP2
PRDW18-14DN-V
PRDW18-14DP-V
PRDW18-14DN2-V
PRDW18-14DP2-V
PRDWL18-14DN
PRDWL18-14DP
PRDWL18-14DN2
PRDWL18-14DP2
Non-Shield
(non-ush)
, 300mm,
M12 connector
PRDW30-15DN
PRDW30-15DP
PRDW30-15DN2
PRDW30-15DP2
PRDW30-15DN-V
PRDW30-15DP-V
PRDW30-15DN2-V
PRDW30-15DP2-V
PRDWL30-15DN
PRDWL30-15DP
PRDWL30-15DN2
PRDWL30-15DP2
Shield
(ush)
PRDW30-25DN
PRDW30-25DP
PRDW30-25DN2
PRDW30-25DP2
PRDW30-25DN-V
PRDW30-25DP-V
PRDW30-25DN2-V
PRDW30-25DP2-V
PRDWL30-25DN
PRDWL30-25DP
PRDWL30-25DN2
PRDWL30-25DP2
Non-Shield
(non-ush)
F-110
Cylindrical, Long Sensing Distance, Cable Connector Type
Dimensions
PRDWT08-2D
Ø15
13
PRDWT08-4D
Ø15 46
13 24 6
PRDW(T)12-4D
Ø21
17
PRDW(T)12-8D
Ø21
17
PRDWL12-4D
46 300
30
Ø3.5
Operation indicator (red)
4
M8×1
Ø3.5
Operation indicator (red)
4
M8×1
52.1 300
31.7
Ø4
4
Operation indicator (red)
M12×1
51.9 300
24.5 7
Ø4
4
Operation indicator (red)
M12×1
300
M12
M12
M12
M12
(unit: mm)
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(A)
Photoelectric
Sensors
(B)
Fiber Optic
Sensors
(C)
LiDAR
(D)
Door/Area
Sensors
(E)
Vision
Sensors
(F)
Proximity
Sensors
(G)
Pressure
Sensors
(H)
Rotary
Encoders
(I)
Connectors/
Connector Cables/
Sensor Distribution
Boxes/ Sockets
PRDWL12-8D
Ø21
17
Ø21
17
64.6 300
44.2
Ø4
4
Operation indicator (red)
M12×1
64.4
37 7
Ø4
4
Operation indicator (red)
M12×1
M12
300
M12
F- 111