Autonics PRCM SERIES Instruction Manual

DRW171500AA
Autonics
INDUCTIVE PROXIMITY SENSOR
(CYLINDRICAL METAL AC CONNECTOR TYPE)
PRCM SERIES
I N S T R U C T I O N M A N U A L
Thank you for choosing our Autonics product.
Please read the following safety considerations before use.
Safety Considerations
Please observe all safety considerations for safe and proper product operation to avoid hazards.
※ ※
symbol represents caution due to special circumstances in which hazards may occur.
Warning Failure to follow these instructions may result in serious injury or death.
Caution
Failure to follow these instructions may result in personal injury or product damage.
Warning
1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in re, personal injury, or economic loss.
2. Do not disassemble or modify the unit.
Failure to follow this instruction may result in electric shock or re.
3. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in electric shock or re.
4. Check 'Connections' before wiring.
Failure to follow this instruction may result in re.
Caution
1. Use the unit within the rated specications.
Failure to follow this instruction may result in re or product damage.
2. Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in electric shock or re.
3. Do not use the unit in the place where ammable/explosive/corrosive gas, humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in re or explosion.
4. Do not supply power without load.
Failure to follow this instruction may result in re or product damage.
Ordering Information
00
Body size
Connection
18
Dimension
AL O
Output
T ~
Power supply
Sensing distance
O Normally open C Normally closed
A 100-240VAC
Number Sensing distance(Unit: mm)
Number Diameter of head(Unit: mm)
No mark Standard type L Long body
CM Connector type
R Cylindrical type
C Inductive proximity sensor
---------j
P R 5CM
Shape
Item
L-----------~
Control Output Diagram & Load Operating
00
Brown
4
Main circuit
The above specications are subject to change and some models may be discontinued without notice.
※
Be sure to follow cautions written in the instruction manual and the technical descriptions (catalog,
※
homepage).
3
Blue
Load
100-240VAC 50/60Hz
Sensing
target
Load
Opera ing
Indicator
(Red LED)
Presence
[
Nothing
Operation
[
Return
ON
[
OFF
N.O. N.C.
_D._ _D._
_D._
n
Specications Mutual-interference & Inuence by Surrounding Metals
Model
Sensing distance 2mm 4mm 5mm 8mm 10mm 15mm
Hysteresis Max. 10% of sensing distance
Standard sensing target 12×12×1mm(Iron)
Setting distance 0 to 1.4mm 0 to 2 8mm 0 to 3.5mm 0 to 5 6mm 0 to 7mm 0 to 10.5mm
Power supply (Operating voltage)
Leakage current Max. 2.5mA
Response frequency
Residual voltage Max. 10V
Affection by Temp. When it is 20℃ at the rated ambient temperature, it is below 10%
Control output 5 to 150mA 5 to 200mA
Insulation resistance Min. 50MΩ(at 500VDC megger)
Dielectric strength 2,500VAC 50/60Hz for 1minute
Vibration 1mm amplitude at frequency of 10 to 55Hz in each of X, Y,Z directions for 2 hours
Shock 500m/s² (approx. 50G) X, Y, Z directions for 3 times
Indicator Operating indicator : Red LED
Ambient temperature
Environ
I
-ment
Ambient humidity 35 to 95%RH, Storage: -30 to 95%RH
I
Protection circuit Surge protection circuit
Protection IP67(IEC standards)
Insulation type
Material Case and nut: Nickel-plated brass, Washer: Nickel-plated steel, Sensing part: PBT
Approval
2
Unit weight
1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times
of the standard sensing target, 1/2 of he sensing distance for the distance.
2: The weight with packaging and the weight in parentheses is only unit weight.
Environment resistance is rated at no freezing or condensation.
Dimensions
00
Type M12 M18, M30 Nut & Washer
Flush
Non-ush
Type A B C D E F G
Flush
Non-ush
● CIA2-
M12
(AC) (AC)
"L" Standard cable length is 2m, 5m.
Wiring Diagram
00
Normally Open(N.O.)/Normally Closed(N.C.)
2
3
1,
Connection of the Power Supply
00
Be sure to connect the power after connecting the load, because direct connection of the proximity sensor may cause damage to the inner elements of this product.
M12 PRCM M12×1 72 8 48 5 4 - 17 21
M18
M30
M12 PRCM M12×1 72 8 41 5 4 7 17 21
M18
M30
Ø14 8
<~
1
Brown
4
Blue
PRCM12-2AO PRCM12-2AC
100-240VACᜠ 50/60Hz(85-264VACᜠ)
1
20Hz
-25 to 70℃, Storage: -30 to 80℃
Double insulation or reinfored insulation
(Mark:
CE
Approx. 42g(Approx. 30g)
B
C
1:
~
D
_JL
B
E
.1·1•
Load
~
C
D
~
PRCM M18×1 60 6 35 8 4 - 24 29 PRCML M18×1 87 3 62 5 4 - 24 29 PRCM M30×1.5 63 8 38 5 - 35 42 PRCML M30×1.5 85 8 60 5 - 35 42
PRCM M18×1 60.1 25 3 4 10 24 29 PRCML M18×1 86 8 52 4 10 24 29 PRCM M30×1.5 63 8 28 5 10 35 42 PRCML M30×1.5 85 8 50 5 10 35 42
40
PRCM12-4AO PRCM12-4AC
[gJ
, dielectric strength between the measuring input part and the power part: 1kV)
·1
I
M12×1
A
•1
·1
A
L
M12×1
Ø5
2
1
3
4
~
100-240VAC 50/60Hz
PRCM18-5AO PRCM18-5AC PRCML18-5AO PRCML18-5AC
18×18×1mm (Iron)
I
PRCM: Approx. 66g(Approx. 54g) PRCML: Approx. 78g(Approx. 66g)
I
● CLA2-
M12
~
Brown
Load
Blue
PRCM18-8AO PRCM18-8AC PRCML18-8AO PRCML18-8AC
25×25×1mm (Iron)
B
C
D
l~
B
E
C
•1°1•
~
·1
D
Ø14.8
27.5
1._Q_______jJ._J..~
In AC switching type, 2 and 3, 1 and 4 are
※
connected inside of the connector cable.
I
PRCM30-10AO PRCM30-10AC PRCML30-10AO PRCML30-10AC
30×30×1mm (Iron)
PRCM: Approx. 154g(Approx. 142g) PRCML: Approx. 194g(Approx. 182g)
I
M12×1
A
·1
M12×1
A
32
L
Ø5
Load
PRCM30-15AO PRCM30-15AC PRCML30-15AO PRCML30-15AC
45×45×1mm (Iron)
(Unit: mm)
H
G
i
100-240VAC
VsVs
50/60Hz
~
Mutual-interference
When several proximity sensors are mounted closely, malfunction of sensor may be caused due to mutual interference. Therefore, be sure to provide a minimum distance between the two sensors, as below charts.
Face to Face
A
((;))
Inuence by surrounding metals
When sensors are mounted on metallic panel, it is required to protect he sensors from being affected by any metallic object except target. Therefore, be sure to provide a minimum distance as below chart.
Model
Item A 12 24 30 48 60 90
B 24 36 36 54 60 90
0 11 0 14 0 15
Ød 12 36 18 54 30 90
m 6 12 15 24 30 45
n 18 36 27 54 45 90
PRCM12-2A
PRCM12-4A PRCM(L)18-5A PRCM(L)18-8A PRCM(L)30-10A PRCM(L)30-15A
Parallel
B
Ød
Target
Moving
direction
Sn:Sensing distance Sa:Setting distance (70% of Sn)
(a) (b)
● Sensing distance can be changed by the shape, size or materia l of the target.
Therefore please check the sensing distance like (a), then pass the target within range of setting distance(Sa).
● Setting distance(Sa)=Sensing distance(Sn)×70%
E g.)PRCM30-10AO
Setting distance(Sa)=10mm×0.7=7mm
Installation and Tightening Torque
When tightening the nut, use the provided washer as [Figure 1] When installing the product, the tightening torque of the nut varies according to the distance from the fore-end. The front part of the product is from the fore-end to the dimension on the below table, and the rear part is from the tip of the nut to the end of the product. [Figure 2] In case the nut is placed in the front part of the product, apply tightening torque for front part. [Table 1] the allowable tightening torque table is for inserting the washer as [Figure 3].
[Figure 1]
Caution during Use
1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
2. Wire as short as possible and keep away from high voltage lines or power lines, to prevent surge and inductive noise. Do not use near the equipment which generates strong magnetic force or high frequency noise (transceiver, etc.). In case installing the product near the equipment which generates strong surge (motor, welding machine, etc.), use diode or varistor to remove surge.
3. Do not connect capacity load to the output terminal directly.
4. This unit may be used in the following environments.
Indoors (in the environment condition rated in 'Specications')
Altitude max. 2,000m
Pollution degree 2
Installation category II
Major Products
00
Photoelectric sensors Temperature controllers
Fiber optic sensors Temperature/Humidity transducers
Door sensors SSR/Power controllers
Door side sensors Counters
Area sensors Timers
Proximity sensors Panel meters
Pressure sensors Tachometer/Pulse(Rate) meters
Rotary encoders Display units
Connector/Sockets Sensor controllers
Switching mode power supplies
Control switches/Lamps/Buzzers
I/O Terminal Blocks & Cables
Stepper motors/drivers/motion controllers
Graphic/Logic panels
Field network devices
Laser marking system(Fiber, CO₂, Nd:YAG)
Laser welding/soldering system
[Figure 2] [Figure 3]
Fore-end
Nut tip
Front Rear
Moving
direction
[Table 1]
Model PRCM12 Series
PRCM18 Series
PRCM30 Series
Washer
Target
Sn
Sa
Front Rear
Strength
Size Torque Torque Flush 13mm Non-ush 7mm Flush ­Non-ush ­Flush 26mm Non-ush 12mm
Mounting
bracket
6.37N.m 11.76N.m
14.7N.m
49N m 78.4N m
m
n
DRW171500AA
(Unit: mm)
Loading...