Autonics PA-12 Series Catalog Page

PA-12 Series
8-Pin Plug Type General-Purpose Sensor Controller
Features
● Selectable use of 110/220VAC
● Selectable use of NPN, PNP input (only for PA-12 model)
● Able to drive loads up to 250VAC 3A, 30VDC 3A with proximity sensor or photoelectric sensor input
● Output relay with both N.O. and N.C. contacts
Please read “Safety Considerations” in operation manual before using.
Ordering Information
PA 12 PG
Type
Power supply
Item
Specifications
Model PA-12 PA-12-PG PA-12-PGP Type Selectable NPN/PNP NPN open collector only PNP open collector only Power supply Selectable 110/220VACᜠ 50/60Hz 110/220VACᜠ 50/60Hz Power consump ion Approx. 4VA
Power supply for sensor
Control output
Input signal
Input resistance 10kΩ
Response time
Environment
Unit weight Approx. 269g
Environment resistance is rated at no freezing or condensa ion.
Unit Description
~
NPN
PNP
Input Min. 0.2ms Output Min. 10ms Ambient temp. -10 to 50℃ Ambient humi. 35 to 85%RH
12VDCᜡ ±10% 50mA 12VDCᜡ ±10% 30mA ( Make sure that total consumption current shall not exceed sensor's power supply capacity when connecting a
sensor.)
• Relay contact output ( Contact capacity
: 250VACᜠ 3A 30VDCᜡ 3A resistance load,
contact arrangement 1a1b)
• Life expectancy
- Mechanical
: Min. 10,000,000 operations
- Electrical : Min. 100,000 operations
Short-circuit impedance : Max. 1kΩ, Residual voltage: Max. 2VDC, Open-circuit impedance : Min. 100kΩ
High level: 7-12VDCᜡ, Low level: 0-5VDC
Output indicator
No mark Power Amplier
PG Pulse generator (NPN type)
PGP Pulse generator (PNP type)
12 110/220VAC 50/60Hz
PA Power amplier
I
l
NPN open collector output PNP open collector output
Allowable input voltage: Max. 30VDCᜡ, Rated current: Max. 50mA
Short-circuit impedance : Max. 1kΩ, Residual voltage: Max. 2VDC, Open-circuit impedance : Min. 100kΩ
-
- -
-
High level: 7-12VDCᜡ, Low level: 0-5VDC
O-10
NPN/PNP
selection switch
Power supply
(POWER)
selection switch
Autonics
The
parts are only for he PA-12 model.
8-Pin Plug Type General-Purpose Sensor Controller
Dimensions
Connections
PA-12
50
, 30VDCᜡ 3A
63.5
8-pin socket: PS-08(N)
PA-12-PG
104
80 24
(unit: mm)
Sold separately
8-pin socket: PS-08(N)
50
40
70
70
23.5
19
14
35
(A) Photoelectric Sensors
(B) Fiber Optic Sensors
(C) Door/Area Sensors
(D) Proximity Sensors
(E) Pressure Sensors
4
(F) Rotary Encoders
(G) Connectors/ Connector Cables/ Sensor Distribution Boxes/ Sockets
(H) Temperature Controllers
(I) SSRs / Power Controllers
(J) Counters
(K) Timers
PA-12-PGP
2-Ø4.5
Selectable 110/220VAC
SOURCE SOURCE 220VAC
Function Diagram
PA-12-PG (NPN open collector)
Input Output
Output sensor
+12V
PA-12-PGP (PNP open collector)
Input Output
Output sensor
+12V
0V
0V
5
10kΩ
IN
4
10kΩ
6
5
IN
10kΩ
4
10kΩ
6
~ 50/60Hz 220VAC~
12V
Main circuit
Main circuit
OUT
0V
OUT
5
3
Allowable input current: Max. 50mA
6
12V
5
3
2
0V
6
Load
Allowable output current: Max. 50mA
Load
Max. 30VDC
Max. 30VDC
S0/60Hz
(L) Panel Meters
(M) Tacho / Speed / Pulse Meters
(N) Display Units
(O) Sensor Controllers
(P) Switching Mode Power Supplies
(Q) Stepper Motors & Drivers & Controllers
(R) Graphic/ Logic Panels
(S) Field Network Devices
(T) Software
Autonics
O-11
PA-12 Series
Operation Mode
PA-12
Mode NPN PNP
Input level
H
L
n n
H
L
n
Relay output
Output display lamp LED
PA-12-PG/PGP
Division selec ion S/W
N.O.
N.C. N.C.
Light ON
Light OFF
1
10
~
Power supply
Sensor input
TR output (Open Collector)
Output display lamp LED
When selecting Re-start mode while opera ing, cut off the power and turn it on again.
Delay Time: Approx. 30ms
t: ON time for input signal
E.g.) When the signal of which input signal is 100Hz (ON: OFF=1:1) is inserted, 1/100Hz=10ms (ON=5ms, OFF=5ms). Since input signal's on time is 5ms, therefore, total delay time for output waveform becomes approx. 35ms(5ms+30ms).
You should consider total delay time first when selecting the division. When division time is shorter than total delay time, output TR keeps
staying ON state.
ON OFF
ON OFF
Light ON
Light OFF
I I
1
2 19 19 1920 20 201 12 2
H L
tfl_J~J--flI1-Iill-JJlfl_j
D
n n
n
0
10
: 20 division (1 to 99 divisions available)
~
Delay time
t
Ii
:
I I I
I I I
:
N.O.
Light ON
Light OFF
.I
n
n n
n
Counting Speed Selection Division Selection Switch
~
PA-12-PG/PGP PA-12-PG/PGP
II
S1
--
--
S2S3
● ON: 30cps
● OFF: 2kcps
※Factory
Proper Usage
~
1. Follow instructions in 'Cau ions during Use'. Otherwise, It may cause unexpected accidents.
2. Since the power for external sensor is without the output short over current protection circuit, do not short circuit 12V and 0V terminals.
3. Use the product, 0.1 sec after supplying power.
4. When supplying or turning off the power, use a switch or etc. to avoid chattering.
5. Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.
6. Keep away from high voltage lines or power lines to prevent inductive noise. In case installing power line and input signal line closely, use line filter or varistor at power line and shielded wire at input signal line. Do not use near the equipment which generates strong magnetic force or high frequency noise.
7. This unit may be used in the following environments.
Indoors (in the environment condition rated in 'Specifications')
Al itude max. 2,000m
Pollution degree 2
Installation category II
O-12
default: 2kcps
ON=
(Connected)
OFF=
(Opened)
*
l
T
~
Autonics
1
0
10
10
~~
Factory
: Selectable from 1 to 99 divisions.
default: 20
10110
0
Loading...