Autonics PA-12 SERIES Instruction Manual

DRW171161AB
Autonics
Sensor Controller
PA-12 SERIES
I N S T R U C T I O N M A N U A L
Please read the following safety considerations before use.
Safety Considerations
※
Please observe all safety considerations for safe and proper product operation to avoid hazards.
symbol represents caution due to special circumstances in which hazards may occur.
Warning Failure to follow these instructions may result in serious injury or death. Caution Failure to follow these instructions may result in personal injury or product damage.
Warning
1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in re, personal injury, or economic loss.
2. Install on a device panel or DIN rail to use.
Failure to follow this instruction may result in electric shock or re.
3. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in electric shock or re.
Failure to follow this instruction may result in re.
5. Do not disassemble or modify the unit.
Failure to follow this instruction may result in electric shock or re.
Caution
1. Use the unit within the rated specications.
Failure to follow this instruction may result in re or product damage.
2. Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in electric shock or re.
3. Do not use the unit in the place where ammable/explosive/corrosive gas, humidity, direct sun­light, radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in re or explosion.
4. Keep metal chip, dust, and wire residue from owing into the unit.
Failure to follow this instruction may result in re or product damage.
Ordering Information
PA
Connections
PA-12
※
The above specications are subject to change and some models may be discontinued
without notice.
※
Be sure to follow cautions written in the instruction manual and the technical descriptions (catalog, homepage).
Thank you for choosing our Autonics product.
12 PG
Selectable 110/220VAC
No mark Power amplier PG Pulse generator (NPN type) PGP Pulse generator (PNP type)
12 110/220VAC 50/60Hz
PA Sensor Controller
PA-12-PG PA-12-PGP
SOURCE
220VAC~ 50/60Hz 220VAC~ 50/60Hz
SOURCE
Dimensions Function Diagram
(unit: mm)
50
63 5
8-pin socket: PS-08(N)
104
80 24
Specications
Model PA-12 PA-12-PG PA-12-PGP Type Selectable NPN/PNP NPN open collector only PNP open collector only Power supply Power consumption
Power supply for sensor
Control output
Input signal
Input resistance 10kΩ
Response
time
Environment
Unit weight Approx. 269g
NPN
PNP
Input Min. 0 2ms Output Min. 10ms Ambient temp. Ambient humi.
Environment resistance is rated at no freezing or condensation.
Selectable 110-220VACᜠ 50/60Hz
Approx. 4VA
12VDCᜡ ±10% 50mA 12VDCᜡ ±10% 30mA
( Make sure that total consumption current shall not exceed sensor's power
supply capacity when connecting a sensor.)
• Relay contact output (Contact capacity
: 250VACᜠ 3A, 30VDCᜡ 3A
resistance load,
contact arrangement 1a1b)
• Life expectancy
- Mechanical
: Min. 10,000,000 operations
- Electr cal
: Min. 100,000 operations
Short-circu t impedance : Max. 1kΩ Residual voltage: Max. 2VDC Open-c rcuit impedance : Min. 100kΩ
High level: 7-12VDCᜡ, Low level: 0-5VDC
-10 to 50℃
35 to 85%RH
110/220VACᜠ 50/60Hz
NPN open collector output
Allowable input voltage: Max. 30VDCᜡ, Rated current: Max. 50mA
Short-c rcuit impedance : Max. 1kΩ Residual voltage: Max. 2VDC Open-circu t impedance : Min. 100kΩ
-
- -
Operation Mode
PA-12
Mode
Input level
Relay output
Output display lamp LED
PA-12-PG/PGP
Division
selection S/W
Power
ON
supply
OFF
Sensor
input
TR output (Open
ON
Collector)
OFF
Output display
Light ON
lamp
Light OFF
LED
NPN PNP
H
I I I I
L
N.O.
n
N.C.
n n
Light ON
Light OFF
1
10
0
10
~ ~
D
: 20 division (1 to 99 divisions available)
I I
1
2 19 19 1920 20 201 12 2
H
---ul_J~J---fUlJUl-J_Ilfl_!
L
Delay time
t
'' ''
I:
:
I I I
:
I I I
Sold separately
8-pin socket: PS-08(N)
70
70
4
PNP open collector output
-
High level: 7-12VDCᜡ, Low level: 0-5VDC
H L
N.O.
N.C.
Light ON
Light OFF
※
※ ※
E.g.) When the signal of which input signal is 100Hz (ON: OFF=1:1) is inserted, 1/100Hz=10ms (ON=5ms, OFF=5ms). Since nput signal's on time is 5ms, therefore, total delay time for output waveform becomes approx. 35ms(5ms+30ms).
※
50
40
23.5 19
14
2-Ø4.5
D
n
n n
D
When selecting Re-start
mode while operating, cut off the power and turn it on again. Delay Time: Approx. 30ms t: ON time for input signal
You should consider total delay time first when selecting the division. When division time is shorter than total delay time, output TR keeps staying ON state.
PA-12-PG (NPN open collector)
Input Output
Output sensor
35
PA-12-PGP (PNP open collector)
Input Output
Output sensor
+12V
IN
0V
+12V
IN
0V
Counting Speed Selection
PA-12-PG/PGP PA-12-PG/PGP
S1
S2S3
● ON: 30cps
● OFF: 2kcps
Factory default: 2kcps
Cautions during Use
1. Follow instructions in 'Cautions during Use'. Otherwise, t may cause unexpected accidents.
2. Since the power for external sensor is without the output short over current protection circuit, do not short circuit 12V and 0V terminals.
3. Use the product, 0.1 sec after supplying power.
4. When supplying or turning off the power, use a switch or etc. to avoid chattering.
5. Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.
6. Keep away from high voltage lines or power lines to prevent inductive noise. In case installing power line and input signal line closely, use line filter or varistor at power line and shielded wire at input signal line. Do not use near the equipment which generates strong magnetic force or high frequency noise.
7. This unit may be used in the following environments.
Indoors (in the environment condition rated in 'Specifications')
Altitude max. 2,000m
Pollution degree 2
Installation category II
Major Products
Photoelectric Sensors Temperature Controllers Fiber Optic Sensors Temperature/Humidity Transducers Door Sensors SSRs/Power Controllers Door Side Sensors Counters Area Sensors Timers Proximity Sensors Panel Meters Pressure Sensors Tachometer/Pulse (Rate) Meters
Rotary Encoders Display Units
Connector/Sockets Sensor Controllers Switching Mode Power Supplies
Control Switches/Lamps/Buzzers I/O Terminal Blocks & Cables
Stepper Motors/Drivers/Motion Controllers Graphic/Logic Panels Field Network Devices Laser Marking System (Fiber, Co₂, Nd: YAG) Laser Welding/Cutting System
12V
5
10kΩ
4
10kΩ
6
5
10kΩ
4
10kΩ
6
ON=
(Connected)
l
OFF=
T
(Opened)
Main circuit
Main circuit
5
OUT
3
0V
6
12V
5
3
OUT
2
0V
6
Division Selection Switch
00
Load
Allowable input current: Max. 50mA
Allowable output current: Max. 50mA
Load
1
0
10
10
: Selectable from 1
to 99 divisions.
Factory default
DRW171161AB
10110
: 20
Max.
30VDC
+
Max.
30VDC
0