DRW171161AB
Autonics
Sensor Controller
PA-12 SERIES
I N S T R U C T I O N M A N U A L
Please read the following safety considerations before use.
Safety Considerations
※
Please observe all safety considerations for safe and proper product operation to avoid hazards.
※
symbol represents caution due to special circumstances in which hazards may occur.
Warning Failure to follow these instructions may result in serious injury or death.
Caution Failure to follow these instructions may result in personal injury or product damage.
Warning
1. Fail-safe device must be installed when using the unit with machinery that may cause serious
injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships,
vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention
devices, etc.)
Failure to follow this instruction may result in re, personal injury, or economic loss.
2. Install on a device panel or DIN rail to use.
Failure to follow this instruction may result in electric shock or re.
3. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in electric shock or re.
4. Check 'Connections' before wiring.
Failure to follow this instruction may result in re.
5. Do not disassemble or modify the unit.
Failure to follow this instruction may result in electric shock or re.
Caution
1. Use the unit within the rated specications.
Failure to follow this instruction may result in re or product damage.
2. Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in electric shock or re.
3. Do not use the unit in the place where ammable/explosive/corrosive gas, humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in re or explosion.
4. Keep metal chip, dust, and wire residue from owing into the unit.
Failure to follow this instruction may result in re or product damage.
Ordering Information
PA
Connections
PA-12
※
The above specications are subject to change and some models may be discontinued
without notice.
※
Be sure to follow cautions written in the instruction manual and the technical
descriptions (catalog, homepage).
Thank you for choosing our Autonics product.
12 PG
※
Selectable 110/220VAC
• •
No mark Power amplier
PG Pulse generator (NPN type)
PGP Pulse generator (PNP type)
12 110/220VAC 50/60Hz
PA Sensor Controller
PA-12-PG PA-12-PGP
SOURCE
220VAC~ 50/60Hz 220VAC~ 50/60Hz
SOURCE
Dimensions Function Diagram
(unit: mm)
50
63 5
8-pin socket: PS-08(N)
104
80 24
Specications
Model PA-12 PA-12-PG PA-12-PGP
Type Selectable NPN/PNP NPN open collector only PNP open collector only
Power supply
Power consumption
Power supply for sensor
Control output
Input signal
Input resistance 10kΩ
Response
time
Environment
Unit weight Approx. 269g
※
NPN
PNP
Input Min. 0 2ms
Output Min. 10ms
Ambient temp.
Ambient humi.
Environment resistance is rated at no freezing or condensation.
Selectable 110-220VACᜠ 50/60Hz
Approx. 4VA
12VDCᜡ ±10% 50mA 12VDCᜡ ±10% 30mA
( Make sure that total consumption current shall not exceed sensor's power
supply capacity when connecting a sensor.)
• Relay contact output
(Contact capacity
: 250VACᜠ 3A, 30VDCᜡ 3A
resistance load,
contact arrangement 1a1b)
• Life expectancy
- Mechanical
: Min. 10,000,000 operations
- Electr cal
: Min. 100,000 operations
Short-circu t impedance
: Max. 1kΩ
Residual voltage: Max. 2VDC
Open-c rcuit impedance
: Min. 100kΩ
High level: 7-12VDCᜡ,
Low level: 0-5VDC
-10 to 50℃
35 to 85%RH
110/220VACᜠ 50/60Hz
NPN open collector
output
Allowable input voltage: Max. 30VDCᜡ,
Rated current: Max. 50mA
Short-c rcuit impedance
: Max. 1kΩ
Residual voltage: Max. 2VDC
Open-circu t impedance
: Min. 100kΩ
-
- -
Operation Mode
PA-12
Mode
Input level
Relay output
Output display
lamp LED
PA-12-PG/PGP
•
Division
selection
S/W
Power
ON
supply
OFF
Sensor
input
TR output
(Open
ON
Collector)
OFF
Output
display
Light ON
lamp
Light OFF
LED
NPN PNP
H
I I I I
L
N.O.
n
N.C.
n n
Light ON
Light OFF
1
10
0
10
~ ~
D
: 20 division (1 to 99 divisions available)
I I
1
2 19 19 1920 20 201 12 2
H
---ul_J~J---fUlJUl-J_Ilfl_!
L
Delay time
t
''
''
I:
:
I I I
:
I I I
Sold separately
•
8-pin socket: PS-08(N)
70
70
4
PNP open collector
output
-
High level: 7-12VDCᜡ,
Low level: 0-5VDC
H
L
N.O.
N.C.
Light ON
Light OFF
※
※
※
E.g.) When the signal of
which input signal is 100Hz
(ON: OFF=1:1) is inserted,
1/100Hz=10ms (ON=5ms,
OFF=5ms).
Since nput signal's on time is
5ms, therefore, total delay time
for output waveform becomes
approx. 35ms(5ms+30ms).
※
50
40
23.5
19
14
2-Ø4.5
D
n
n n
D
When selecting Re-start
mode while operating, cut
off the power and turn it
on again.
Delay Time: Approx. 30ms
t: ON time for input signal
You should consider total
delay time first when
selecting the division.
When division time is
shorter than total delay
time, output TR keeps
staying ON state.
PA-12-PG (NPN open collector)
Input Output
Output sensor
35
PA-12-PGP (PNP open collector)
•
Input Output
Output sensor
+12V
IN
0V
+12V
IN
0V
Counting Speed Selection
PA-12-PG/PGP PA-12-PG/PGP
S1
S2S3
● ON: 30cps
● OFF: 2kcps
※
Factory default: 2kcps
Cautions during Use
1. Follow instructions in 'Cautions during Use'. Otherwise, t may cause unexpected accidents.
2. Since the power for external sensor is without the output short over current protection circuit, do
not short circuit 12V and 0V terminals.
3. Use the product, 0.1 sec after supplying power.
4. When supplying or turning off the power, use a switch or etc. to avoid chattering.
5. Install a power switch or circuit breaker in the easily accessible place for supplying or
disconnecting the power.
6. Keep away from high voltage lines or power lines to prevent inductive noise.
In case installing power line and input signal line closely, use line filter or varistor at power line
and shielded wire at input signal line.
Do not use near the equipment which generates strong magnetic force or high frequency noise.
7. This unit may be used in the following environments.
Indoors (in the environment condition rated in 'Specifications')
①
Altitude max. 2,000m
②
Pollution degree 2
③
Installation category II
④
Major Products
Photoelectric Sensors Temperature Controllers
Fiber Optic Sensors Temperature/Humidity Transducers
Door Sensors SSRs/Power Controllers
Door Side Sensors Counters
Area Sensors Timers
Proximity Sensors Panel Meters
Pressure Sensors Tachometer/Pulse (Rate) Meters
Rotary Encoders Display Units
Connector/Sockets Sensor Controllers
Switching Mode Power Supplies
Control Switches/Lamps/Buzzers
I/O Terminal Blocks & Cables
Stepper Motors/Drivers/Motion Controllers
Graphic/Logic Panels
Field Network Devices
Laser Marking System (Fiber, Co₂, Nd: YAG)
Laser Welding/Cutting System
■
■
■
■
■
■
■
■
■
12V
5
10kΩ
4
10kΩ
6
5
10kΩ
4
10kΩ
6
※
ON=
(Connected)
l
OFF=
T
(Opened)
Main circuit
Main circuit
5
OUT
3
0V
6
12V
5
3
OUT
2
0V
6
Division Selection Switch
00
•
Load
Allowable input
current: Max. 50mA
Allowable output
current: Max. 50mA
Load
1
0
10
10
: Selectable from 1
to 99 divisions.
※
Factory default
DRW171161AB
10110
: 20
Max.
30VDC
+
Max.
30VDC
0