Autonics AS80-50 SERIES Instruction Manual

DRW171506AA
Autonics
INDUCTIVE LONG DISTANCE PROXIMITY SENSOR
AS80-50 SERIES
I N S T R U C T I O N M A N U A L
Thank you for choosing our Autonics product.
Please read the following safety considerations before use.
Safety Considerations
Please observe all safety considerations for safe and proper product operation to avoid hazards.
※ ※
symbol represents caution due to special circumstances in which hazards may occur.
Warning Caution
It
1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
2. Do not disassemble or modify the unit.
Failure to follow this instruction may result in re.
3. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in re.
4. Check 'Connections' before wiring.
Failure to follow this instruction may result in re.
1. Use the unit within the rated specications.
Failure to follow this instruction may result in re or product damage.
2. Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in re.
3. Do not use the unit in the place where ammable/explosive/corrosive gas, humidity,
direct sunlight, radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in re or explosion.
Ordering Information
00
A
The above specications are subject to change and some models may be discontinued
without notice.
Be sure to follow cautions written in the instruction manual and the technical
descriptions (catalog, homepage).
Failure to follow these instructions may result in serious injury or death.
Failure to follow these instructions may result in personal injury or product damage.
Warning
Caution
D
N350
II
IT
Control output
Power supply
Sensing distance
N3 NPN output (N.O+N.C Symmetrical output)
P3 PNP output (N.O + N.C Symmetrical output)
I
D 12-48VDC
I
I
Number Standard sensing distance(unit: mm)
I I
Number A side length(unit: mm)
I
I
S Square
I
A Inductive proximity sensor
I I
I
I
Item
S 80
Shape
-I
Dimension
Specications
Model AS80-50DN3 AS80-50DP3 Sensing distance 50mm Hysteresis Max. 15% of sensing distance Standard sensing
target Setting distance 0 to 35mm Power supply
(Operating voltage) Current consumption Max. 20mA Response frequency 30Hz Residual voltage Max. 2V Affection by Temp. Control output 200mA Insulation resistance Min. 50MΩ (at 500VDC megger) Dielectric strength 1500VAC 50/60Hz for 1 minute
Vibration Shock 500m/s² (approx. 50G) in X, Y, Z directions for 3 times
Indicator Power indicator: Green LED, Operating indicator: Yellow LED
Ambient temp. -25 to +70, Storage: -30 to +80
Enviro-
I
nment
Ambient humi. 35 to 95%RH, Storage: 35 to 95%RH
I
Protection circuit Reverse polarity protection, Surge protection, Overload & short-circuit protection Protection IP67(IEC specication)
※1
Cable
Material Case: Heat-resistant ABS, Standard cable(Black): PVC
Approval Unit weight Approx. 470g
1: Do not pull the cable with a tensile strength of 50N or over. It may result in re due to the broken
wire. When extending wire, use AWG22 cable or over within 200m.
Environment resistance is rated at no freezing or condensation.
Dimensions
Operation indicator (Yellow LED)
45
lliE
Control Output Diagram & Load Operating
00
Output
NPN
(N.O+ N.C)
PNP
(N.O+ N.C)
Circuit
Main circuit
Main circuit
150×150×1mm(Iron)
12-48VDCᜡ (10-65VDC)
±10% max. of sensing distance at +20within temperature range of -25 to 70
1mm amplitude at frequency of 10 to 55Hz in each of X, Y, Z directions for 2 hours
Ø5mm, 4 cores, 2m AWG22, core diameter: 0.08mm, number of cores: 60, insulator diameter: Ø1.25mm
CE
2000
4-Ø5.5
(Green LED)
]
Load operating
+V
Sensing target
Load (Brown-Black)
Output voltage (Black-Blue)
Operation indicator
0V
(Yellow LED)
+V
Sensing target
Load (Black-Blue)
Output voltage (Black-Blue)
0V
Operation indicator (Yellow LED)
80
30
65
20
47
47
80
65
Power
Ø74
Load connection
Brown
47
Black (N.O)
White
(N.C)
Blue
Brown
Black (N.O)
White
(N.C)
47
Blue
indicator
9
102
Load
Load
Load
Load
Ø5
~
[
[
[
[
I
When installing the product,
tighten the screw with a tightening torque of 1.47N.m.
~
Sensing target
Load (Brown-White)
Output voltage (White-Blue)
Operat on indicator (Yellow LED)
Sensing target
Load (White-Blue)
Output voltage (White-Blue)
Operat on indicator (Yellow LED)
Presence
Nothing
Operation
Return
H
[
L
ON
[
OFF
Presence
Nothing
Operation
Return
H
[
L
ON
[
OFF
E
N.O
n
N.O
n n
n
(unit: mm)
97
Presence
[
Nothing
Operation
[
Return
H
[
L
ON
[
OFF
Presence
[
Nothing
Operation
[
Return
H
[
L
ON
[
OFF
11
N.C
n
N.C
n
Mutual-Interference & Inuence By Surrounding Metals
Mutual-interference
When plural proximity sensors are mounted in closely, malfunction of sensor may be caused due to mutual interference. Therefore, be sure to provide a minimum distance between the two sensors, as picture below.
320
(Face to Face)
.......
AS80 - 50DN3
Sn:50mm
©
a k
N
e
[gr [g[
N
e
E N K RE
4 39
~
320
(€
+1 -65
20 m max
0
(Parallel)
AS80 - 50DN3
'""""'
Sn:50mm
©
(€
10-65
ack
00m m x
N
e
N
e
0
E N K RE
4 139
~
(unit: mm)
Inuence by surrounding metals
When sensors are mounted on metallic panel, it may cause malfunction affected by any metallic object except target. Therefore, be sure to provide a minimum distance shown in picture right.
Setting Distance
00
Target
Moving direc ion
ii
'
E5
( a ) ( b )
● Sensing distance can be changed by the shape, size or material of the target. Therefore please check the sensing distance like(a), then pass the target within range of setting distance(Sa).
● Setting distance(Sa)= Sensing distance(Sn) × 70% E.g.) AS80-50DN3 Setting distance(Sa)
= 50mm × 0.7 = 35mm
Cautions During Use
1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
2. 12-48VDC power supply should be insulated and limited voltage/current or Class 2, SELV power
supply device.
3. Use the product, after 0.8 sec of supplying power.
4. Wire as short as possible and keep away from high voltage lines or power lines, to prevent surge
and inductive noise. Do not use near the equipment which generates strong magnetic force or high frequency noise (transceiver, etc.). In case installing the product near the equipment which generates strong surge (motor, welding ma­chine, etc.), use diode or varistor to remove surge.
5. This unit may be used in the following environments.
Indoors (in the environment condition rated in 'Specications')Altitude max. 2,000mPollution degree 2Installation category II
Sn: distance
{
Sa: Setting distance (70% of Sn)
Sensing
Moving direction
80
Target
Sa
Sn
150
Metal
80
Major Products
Photoelectric sensors Temperature controllers
Fiber optic sensors Temperature/Humidity transducers
Door sensors SSR/Power controllers
Door side sensors Counters
Area sensors Timers
Proximity sensors Panel meters
Pressure sensors Tachometer/Pulse(Rate)meters
Rotary encoders Display units
Connector/Sockets Sensor controllers
Switching mode power supplies
Control switches/Lamps/Buzzers
I/O Terminal Blocks & Cables
Stepper motors/drivers/motion controllers
Graphic/Logic panels
Field network devices
Laser marking system(Fiber, CO₂, Nd:YAG)
Laser welding/cutting system
DRW171506AA
Loading...