Supply Voltage +24VDC1
TestTest2
0V0V3
N/ANot Used4
Note: Confirm the specific color to each pinout based
N.O.
1
0V
2
34
TEST
on the cable used during installation.
+24VDC
NOT USED
Pins on
Sender
M12
Safety Electrical Components
tESC-2
1-800-633-0405
For the latest prices, please check AutomationDirect.com.
Datalogic Safety Light Curtains
Base Series
SG4-14 and SG4-30 Base Series with EDM Specifications
Model
Supply Voltage
Current Consumption (Sender)
Current Consumption (Receiver)
OSSD Outputs
Short Circuit Protection
Output Current
Output Voltage – ON status:
Output Voltage – OFF status:
Leakage Current
Operating Temperature
Storage Temperature
Temperature Class
Humidity
Mechanical Protection
Vibrations
Housing Material
Protective Shield Material
Cap Material
Weight
Agency Approvals
To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number's web page at www.AutomationDirect.com
SG4-14 Base Series (finger protection)SG4-30 Base Series (hand protection)
Electrical Data
24VDC ± 20%
2.5 W maximum
3.5 W maximum (without load)
2 PNP
1.4 A maximum
0.5 amps maximum on each output
Vdd-1V minimum
0.2 V maximum
< 1mA
2.2 uF @ 24VDC
(if a longer cable must be used, verify that the capacitive load specifications are respected)
150 - 900 mm (5.91 - 35.43 in)300 - 1800 mm (11.81 - 70.87 in)
Type 4, IEC 61496-1
Reset / Test
Selectable Manual / Automatic Reset
Selectable EDM
Class I / Class III
M12 4-pole for sender
M12 8-pole for receiver
50m (164ft) maximum
(if a longer cable must be used, verify that the capacitive load specifications are respected)
Optical Data
Infared LED (950nm)
14mm30mm
0.2 - 6 m0.2 - 19 m
±2.5° maximum
IEC 61496-2
Mechanical and Environmental Data
0 to 55°C (32 to 131°F)
-25 to 70°C (-13 to 158°F)
T6
15 - 95% (non-condensing)
IP65 (EN 60529)
Width 0.35 mm
Frequency 10 - 55 Hz 20 sweep per axis
1 octave / min (EN 60068-2-6)
Painted aluminum (yellow RAL 1003) front screen
PMMA (Polymethylmethacrylate [acrylic])
PC MAKROLON
1.3 Kg / m
UL E226479, CE, TUV, RoHS
Status Indicators
Receiver
NORMAL
O P.
SAFE
(BREAK)
www.automationdirect.com
LAST
SYNC
NORMAL
O P.
Sender
ON
Safety Electrical Components
tESC-4
1.21
1-800-633-0405
For the latest prices, please check AutomationDirect.com.
$18.50Mounting brackets, rotational, metal, package of 4. For use with SG4 base series (-E) light curtains.4
$9.25Mounting brackets, standard, metal, replacement, package of 4. For use with all SG4 series light curtains.4
$43.50Mounting brackets, lateral orientable, metal, package of 4. For use with all SG4 series light curtains.4
$18.50Mounting brackets, anti-vibration, metal, package of 4. For use with all SG4 series light curtains.4
40.0
1.57
3.0
0.12
6.6
0.26
18.5
0.73
12.9
0.51
30.7
18.5
0.73
8.0
0.31
37.8
1.49
6.6
0.26
(2X)
17.3
0.68
ST-KSTD
ST-K4OR
www.automationdirect.com
ST-K4AV
Safety Electrical Components
tESC-20
1-800-633-0405
For the latest prices, please check AutomationDirect.com.
Datalogic Safety Light Curtains
Accessories
Test Pieces
TP-14 and TP-30 test pieces are used to verify if the resolution of safety light curtains is maintained inside the entire detection field. TP-14 has a
diameter of 14mm [0.55 in] and TP-30 has a diameter of 30mm [1.18 in]. Both models have an overall length of 300mm [11.81 in].
Safety Light Curtains Test Pieces
Part NumberPriceDescription
TP-14
TP-30
$21.50Test rod for 14mm resolution finger detection light curtains, plastic, 14mm diameter
$23.50Test rod for 30mm resolution hand detection light curtains, plastic, 30mm diameter
TP-14
TP-30
www.automationdirect.com
Safety Electrical Components
tESC-21
1-800-633-0405
Safety Products
Warning: Safety products sold by AutomationDirect are Safety components only. The purchaser/installer is
solely responsible for the application of these components and ensuring all necessary steps have been taken
to assure each application and use meets all performance and applicable safety requirements and/or local,
national and/or international safety codes as required by the application. AutomationDirect cannot certify
that our products, used solely or in conjunction with other AutomationDirect or other vendors’ products,
will assure safety for any application. Any person using or applying any products sold by AutomationDirect
is responsible for learning the safety requirements for their individual application and applying them, and
therefore assumes all risks, and accepts full and complete responsibility, for the selection and suitability of
the product for their respective application.
AutomationDirect does not provide design or consulting services, and cannot advise whether any
specific application or use of our products would ensure compliance with the safety requirements for any