Do-more H2 Series PLC System Specifications
General Specifications
General Specifications
Operating Temperature
Storage Temperature
Ambient Humidity
Environmental Air
Vibration
Shock
32°F to 131°F (0°C to 55°C)
–4°F to 158°F (–20°C to 70°C)
30% to 95% relative humidity (non–condensing)
No corrosive gases
MIL STD 810C, Method 514.2
IEC60068-2-6
JIS C60068-2-6 (Sine wave vibration test)
MIL STD 810C, Method 516.2
IEC60068-2-27
JIS C60068-2-27
Noise Immunity
Agency Approvals
NEMA ICS3-304
UL508 (File No. E157382, E316037)
CE (EN61131-2)
www.automationdirect.com
www.automationdirect.com
Do-more H2 PLCs
Do-more H2 PLCs
tDMH-12
tDMH-12
![](/html/13/1397/139745ea6634c19d953973ef9c9a380925bc67a1f685c032e78a00ba7eb0d476/bg2.png)
1-800-633-0405
1-800-633-0405
CPU Modules
Specifications
Total Memory (bytes)
Ladder Memory (instruction words)
V-Memory (words)
Non-volatile V Memory (words)
D-memory (DWORDs)
Non-volatile D Memory (DWORDs)
R-memory (REAL DWORDs)
Non-volatile R Memory (REAL DWORDs)
Boolean execution/K
Stage Programming
Number of Stages
Handheld Programmer
Programming Software for Windows
Built-In communications ports
Program Memory
Total I/O points available
H2-DM1
$310.00
H2-DM1E
$415.00
Local I/O points available
Ethernet Remote I/O Discrete points
Ethernet Remote I/O Analog I/O Channels
Max Number of Ethernet slaves per Channel
I/O points per Remote Channel
Discrete I/O Module Point Density
Slots per Base
Number of instructions available
Control relays
Special relays (system defined)
Special registers (system defined)
Timers
Counters
System Date/Time structures
User Date/Time structures
ASCII String/Byte buffer structures
Modbus Client memory
DL Classic Client memory
Immediate I/O
Interrupt input (hardware / timed)
Subroutines
Drum Timers
Table Instructions
Loops
Math
ASCII
PID Loop Control, Built In
Time of Day Clock/Calendar
Run Time Edits
Supports True Force
Internal Diagnostics
Password security
System error log
User error log
Battery backup
Feature H2-DM1
Configurable up to 65536 (4096 default)
Configurable up to 65536 (4096 default)
Configurable up to 65536 (4096 default)
Configurable up to 65536 (4096 default)
Configurable up to 65536 (4096 default)
Configurable up to 65536 (4096 default)
128 per Program code-block; number of code-blocks configurable to memory limit
USB, RS-232
X, Y, each configurable up to 65536 (2048 default); WX, WY (analog in/out)
Yes, configurable up to memory limit, default 1024 input bits, 1024 coil bits,
>60 operators and functions: Integer, Floating Point, Trigonometric, Statistical,
Yes, IN/OUT, Serial, Ethernet TCP and UDP; 11 output script commands
each configurable up to 65536 (256 default)
>160 >170
Configurable up to 65536 (2048 default)
Configurable up to 65536 (256 default)
Configurable up to 65536 (256 default)
Configurable up to 65536 (32 default)
Configurable up to memory limit (192 default)
2048 input registers, 2048 holding registers
Up to memory limit, default 512 X, 512 Y, 512 C, 2048 V
Program and Task code-blocks, up to memory limit
FOR/NEXT, WHILE/WEND, REPEAT/UNTIL loops
Yes, configurable to memory limit (over 2000)
Multi-user, credentialed, session-based security
For the latest prices, please check AutomationDirect.com.
For the latest prices, please check AutomationDirect.com.
H2-DM1E
262144 bytes
65536 instruction words
50us
Yes
No
FREE Do-more Designer
USB, RS-232,
Ethernet (10/100 Base-T)
Flash ROM
256
131072
32768
16
32768
4/8/12/16/32
3/4/6/9
1024
512
8
No
No
Yes, up to memory limit
Yes
Logical, Bitwise, Timing
Yes
Yes
Yes
Yes
Yes
Yes
Yes (Battery included)
www.automationdirect.com
www.automationdirect.com
Do-more H2 PLCs
Do-more H2 PLCs
tDMH-13
tDMH-13
![](/html/13/1397/139745ea6634c19d953973ef9c9a380925bc67a1f685c032e78a00ba7eb0d476/bg3.png)
H2-DM1E
PWR
RUN
ROM
ERR
ETH
USB
TX
RX
1-800-633-0405
1-800-633-0405
CPU Modules
For the latest prices, please check AutomationDirect.com.
For the latest prices, please check AutomationDirect.com.
H2-DM1
LED Status Indicators
PWR
RUN
ROM
ERR
H2-DM1
-
H2-DM1
PWR
PWR
RUN
N
ROM
ERR
H2-DM1E
-
USB
TX
RX
ETH
T
USB
TX
RX
LED Indicators
Indicator Status Description
PWR
RUN
ROM
ERR
ETH
USB
TX
RX
Green Base Power ON
Yellow Low Battery
Green CPU is in RUN Mode
Yellow Forces are Active
Yellow
Red CPU Fatal Error
Green Ethernet Link Good
Yellow Ethernet Activity
Green USB Receive Activity
Yellow USB Transmit Activity
Green RS-232 Transmit Activity
Green RS-232 Receive Activity
CPU is updating Non-volatile
Memory
H2-DM1E
H2-DM1E
PLC Mode Switch
www.automationdirect.com
www.automationdirect.com
RUN
TERM
STOP
Mode Switch Functions
Mode Switch Position CPU Action
RUN (Run Program)
TERM (Terminal)
STOP (Stop Program)
CPU is forced into RUN Mode if no errors are encountered.
RUN, PROGRAM and DEBUG modes are available.
In this mode, the mode of operation can be changed
through the Programming Software.
CPU is forced into STOP Mode.
Do-more H2 PLCs
Do-more H2 PLCs
tDMH-14
tDMH-14