4
OPERATING CONTROLS
1. LIGHT CODE button (White) is
used for storing or erasing the transmitter button (code) you wish to use to turn
the courtesy light on and off.
2. DOOR CODE button (Blue) is
used for storing or erasing the transmitter button (code) you wish to use to
command the door to open, stop or
close.
3. CLOSE DRIVE button (Red) is
used during installation to help set the
close limit stop position. Pressing and
holding this button will move the door
in the close direction. Movement stops
when the button is released.
NOTE: The close safety obstruction
detection is inoperable whenever the
Close Drive button is used to move
the door.
4. CLOSE LIMIT LED (Red) the
LED is very helpful during installation.
It illuminates and flashes when the door
is closing and remains steady on when
the close limit is activated
5. AUTO CLOSE TIME button
(White) is used to adjust the auto close
time. While holding in the Auto Close
button and then pressing the Open button the time is increased, pressing the
Close button will decrease the time.
(each press will increase the time by 5
seconds).
6. RESET button is used to initialise
and set the door/opener operating
parameters, including cycle times and
obstruction force settings. Check the
installation manual for other uses.
7. O/S/C button (Yellow) is used during installation to test the Open, Stop
and Close cycles for the Opener. The
Opener has to be initialised by the Reset
button before the O/S/C button becomes
operable.
8. CLOSE LIMIT ADJUST SCREW
(Red) is used to fine adjust the close
limit stop position. See installation
section on how to adjust.
9. OPEN LIMIT ADJUST SCREW
(Green) is used to fine adjust the open
limit stop position. Check installation
section on how to adjust.
10. CLOSE LIMIT CAM (Red) is
used to set the close limit stop position.
Check installation section on how to
adjust.
11. OPEN Drive button (Green) is
used during installation to help set the
open limit stop position. Pressing and
holding this button will move the door
in the open direction. Movement stops
when the button is released.
NOTE: The open obstruction
detection is disabled whenever the
Open Drive button is used to move
the door.
12. OPEN LIMIT LED (Green) the
LED is very helpful during installation.
It illuminates and flashes when the door
is opening and remains steady on when
the open limit is activated.
13. OPEN LIMIT CAM (Green) is
used to set the open limit stop position.
Check installation section on how to
adjust.
14. FORCE MARGIN SET button
(White) is used to change the force
pressure when the door encounters an
obstruction. Pressing the Force Margin
Set button and Open or Close button
will increase or decrease the force.
Normally the force pressure is set automatically. The Force Margin Set is only
ever used if other environmental factors
(wind, etc.) affect the operations of the
Door/Opener.
15. P.E. Input is for connection of
Photo Electric Beams (optional extra)
for extra safety obstruction protection,
are compulsory when used with Auto
Close mode.
NOTE: P.E. SHUNT must not be
removed otherwise the Opener will
not function correctly. Remove only
when a P.E. is to be connected.
16. EXTERNAL RECEIVER
INPUT is the input where an external
receiver can be connected (optional
extra). The receiver must be able to
operate on 24 volts DC (50mA max).
17. SECURALIGHT Input is used for
connecting a Securalight (optional
extra) Monitor. A Securalight is a
monitor unit which is mounted inside
your home and is connected to the
Opener by wire cable. The monitor
indicates the status of the door, for
example, if the door is moving or is
opened or closed, etc. The door can also
be controlled from the monitor unit.
18. O/S/C Input is for connecting the
wired Wall Switch (optional extra).
19. P. E. SHUNT The shunt has to be
removed when connecting a Photo
Electric Beam.
20. ENGAGE/DISENGAGE HANDLE when pulled down and released
will select manual mode on Opener
when there is a power failure. Pulling
down and releasing again will select
automatic mode on the Opener.