AFD-200
SERVICE MAINTENANCE CHECKLIST
COMPLETED CHECKLIST MUST ACCOMPANY ALL WARRANTY CLAIMS
Date: Serial Number:
1. UPPER GUIDE ASSEMBLY NOT DAMAGED, SLIDE SCREWS TIGHT
2. LOWER GUIDE ASSEMBLY NOT DAMAGED, SLIDE SCREWS TIGHT
3. UPPER / LOWER GUIDE ASSEMBLIES ALIGNED WITH LIFT SADDLE, COLLARS TIGHT*
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
LIFT SADDLE DOVETAIL SCREWS TIGHT*, CARRIAGE GUIDE NOT DAMAGED OR MISSING
LIFT CYLINDER NOT LEAKING, BAND NOT DAMAGED OR MISSING.
ACCUMULATOR DOOR COLLARS TIGHT*, ADJUSTED 1/8 INCH (4 MM) AWAY FROM CLADDING
HOPPER NOT TOUCHING ACCUMULATOR DOORS, CENTERED
COMPRESSOR PRESSURE SWITCH SET FOR 90-110 PSI (6-7.5 BAR), PURGE VALVE WORKS
QUICK DISCONNECT NOT DAMAGED OR LEAKING, FITS SECURELY
START/RESET LIGHT WORKS
POWER SUPPLY = 24.5 VDC (±0.2)
NO AIR LEAKS, AIR LINES NOT DAMAGED
WATER TRAP BOWL NOT CRACKED OR LEAKING
AIR PRESENT SWITCH SET FOR 60 PSI (4 BAR)
REGULATOR PRESSURE SET FOR 80 PSI (5.5 BAR)
PE1 / PE2 SENSOR RANGE 4 - 6 INCHES (10 - 15 CM)
STOP GATE 1 SECOND OPENING / CLOSING
ACCUMULATOR DOORS 0.5 SECONDS OPENING / 1 SECOND CLOSING
LIFT SADDLE UP/DOWN SPEED 2 SECONDS
BASKET LOAD OFFSET SWITCHES OFF
CALIBRATE LOAD CELL
SELECTOR SWITCH OPERATES SINGLE, 1#, AND 1.5# MODES CORRECTLY
USING CORRECT BASKETS (MUST HAVE GUIDE RUNNERS ON THE BOTTOM) CYCLE A
MINIMUM OF 5 BASKETS. BASKETS SHOULD FILL AND TRANSITION SMOOTHLY TO THE LOWER
GUIDE. THE LIFT SADDLE SHOULD REMAIN IN THE DOWN POSITION WHEN THE LOWER GUIDE IS
FULL (5 BASKETS). THE ACCUMULATOR DOORS SHOULD FILL IN PREPARATION FOR THE NEXT
BASKET.
* APPLY LOCTITE
Copyright © 2005 Automated Equipment, LLC. All Rights Reserved