Autoglide Magro-500 J, Magro-650 J User Manual

Magro-J – Series
Swing Gate Opener
User Manual
2018
Dear users,
Thank you for choosing this product. Please read the manual carefully before assembling and using it.
Please do not leave out the manual if you send this product to a third party.
1. Safety Instruction
Please ensure that the using power voltage matches with the supply voltage of gate opener
(AC110V or AC220V); kids are forbidden to touch the control devices or the remote-control unit.
The remote-control unit is controlled by a single button mode or three button mode (please refer to
the instructions of the remote control in accordance with the actual gate opener type). The indicator
light on the remote-control unit will flicker when the button on it is pressed. Main engine and gate
can be unlocked by disengagement wrench and the gate can move with manual operation after
disengagement.
Please ensure that no one is around the main engine or gate when the switch is operated and it is
usually demanded to examine the stability of installation. Please temporarily stop using if the main
engine needs repairing or regulation.
The installation and maintenance of the products must be carried out by professionals.
2
2. Packing List (standard)
No. Picture Name Quantity
1
2
3
4
5
6
Main engine 2
Manual release bar 1
A
A
B
B
C
C
D
D
Remote control 2
Control box 1
Wall bracket 4
Front mounting bracket 2
7
Connecting bracket 2
8
Mounting screw (short) 2
9
Mounting screw (length) 2
10
Screw M8×25 4
11
Nut M8 8
12
Safety stopper (Optional) 1
3
2. Packing list (optional)
No. Picture Name Quantity
1
1 2 3
5 6974
8
2
0
3
4
5
3. Technical parameters
Infrared sensor 1
Wireless keypad 1
Alarm lamp 1
Electronic lock 1
Storage battery 2
Model
Power supply
Motor power
Gate moving speed
18~22 second per 90 (approx)
Max.single-leaf weight
Max.single-leaf length
Max.piston stroke: 34cm
Max.force
Remote control distance
Magro - 500 J
220V/50Hz;110V/60Hz
80W
250 Kg
2.5M
1500N
≥30m
Magro - 650 J
220V/50Hz;110V/60Hz
80W
18~22 second per 90 (approx)
325 Kg
3.0M
54cm
1500N
≥30m
Remote control mode Single /Three button mode Single / three button mode
Storage battery (optional)
Noise
DC24V (4.5AH or 9.0AH) DC24V (4.5AH or 9.0AH)
≤58dB ≤58dB
Working duty S2, 30min S2, 30min
Recording of up remote controls
25 25
Frequency 433.92 MHz 433.92 MHz
Working temperature -20°C - +70°C -20°C - +70°C
Package weight 17Kg 19Kg
4
4. Installation
Magro J Series swing gate opener is applicable to single leaf gate weight less than 225/300 kg, and length of the single leaf swing gate should be less than 2.5m/3m. The drive mode adopts the worm and worm gear to combine the screw rod transmission. This gate opener must be installed inside the enclosure or yard for protection.
4.1 Installation drawing
Figure 1
Control box; ② Gate opener; ③ Gate; ④ Alarm lamp (optional);
Infrared sensor (optional); ⑥ Stopper; ⑦ Remote control; ⑧ Wireless keypad (optional);
4.2 Size of main engine and accessories
4.2.1 Size of main engine
n
i
M
0
6
2
1 2 3
5 6974
8
0
x
a
0
M
7
9
Magro - 500 J
104
190
5
4.2.2 Size of mounting plate
x
Ma
0
7
3
1
Magro – 650 J
Figure 2
n
i
M
0
8
2
104
190
1
8
5
.
0
7
0
4
2× 8
φ
.5
Front mounting bracket
Figure 3
4.3 Installation steps
4.3.1 Preparation before main engine installation
a) Before installing the door opener, please confirm the correct installation of the door to ensure that the door can be easily manually operated, and the door safety stopper can effectively prevent the door to continue moving. b) Install the electric lock, the distance between the door bottom and ground should be 40-50mm. If not install the electric lock, the distance between door bottom and ground should be ≥20mm; c) The main engine recommended mounting height is about 300 ~ 800mm from the ground, and make sure there are reliable fixed points for mounting brackets.
Cable
In order to ensure the normal operation of the door opener and protect the cable from damage, please use PVC pipe laying motor, power cable, and control cables, and separate two PVC pipes to lay (motor and power cable) and (control cable), respectively.
3
4
Wall bracket
7
.
5
6
Mounting brackets
In order to install the Magro - 500 J / Magro - 650 J main engines firmly, recommend to use the expansion screws to fix the mounting brackets.
4.3.2 Accessory
a) Before installing the main engine, install the wall bracket on the wall, then fix the connecting bracket, and install the front mounting bracket on the door.
Note: Please detect by gradienter before fixing, to ensure that the front mounting bracket and the connecting bracket in the same level.
Hexagon screw
Expansion screw
Hexagon screw
Nut
Nut
Figure 4
b) The connecting bracket and the wall bracket can be connected according to different conditions,
as shown in figure 5.
c) Users shall prepare power cables for the control box and main engines, according to different
installation environment; the power cable of the control box is not less than 3 cores, and the motor
cable with 2 cores. If you need to install electric locks, infrared sensor, alarm lamp, external button
switch and other external equipment, please increase corresponding the embedded wire, and the
sectional area of electric lock cable core shall not be lower than 1.5mm², others shall not be lower
than 0.5mm². The length is determined by the user of according to the situation in the installation
site.
Figure 5
7
Note: The pipe outlet should be facing down to avoid rain water entering the pipe along the cable.
d) Before the installation, please unlock the main engine. Method: Remove the cover, insert the
manual release bar, rotate the bar until the release, as shown in Figure 6, then turn the telescopic
arm to make it easily stretch.
Left engine
Right engine
Figure 6
4.3.3 Main engine installation
As shown in Figure 7, the tail of the main engine and the connecting bracket are fixed together through the installation of screws, and then manually adjust the telescopic arm to the appropriate length, and finally fix the telescopic arm connector and the front mounting bracket with the installation screws. Pull the door after the completion of the installation to ensure the entire process flexible without jamming.
8
Mounting screw (length)
Nut
Figure 7
Installation direction: door open facing inward (Magro - 500 J)
Note:Note: SafetySafety stopperstopper mustmust bebe installedinstalled
B
A
Mounting screw (short)
Nut
L
K
L=620+5L=620+5 K<620+340620+340
Figure 8
9
100 110 120 130 14 0 150 160 170 180 190 200
100 110 120 130 140 150 160 170 180 190 200
mmmm
Max 90°
Max 120°
Max 110°
Max 100°
B
A
Figure 9
Note: Value B must be close to or equal to the value A to obtain the best mechanical advantage.
Installation direction: door open facing outward (Magro - 650 J)
Note:Note: SatetySatety blockblock mustmust bebe installed,installed, isis proviedprovied byby installerinstaller
K
L=620+5L=620+5 K<620+340620+340
B
A
Figure 10
L
Note:Note: SafetySafety stopperstopper mustmust bebe installedinstalled
10
100 110 120 130 140 150 160 170 180 190 200
100 110 120 130 140 150 160 170 180 190 200
Max 90°
Max 100°
Max 110°
B
Max 120°
mmmm
A
Figure 11
Note: Value B must be close to or equal to the value A to obtain the best mechanical advantage.
Installation direction: door open facing inward (Magro - 500 J)
Note:Note: SafetySafety stopperstopper mustmust bebe installedinstalled
B
A
K
L
L=820+10L=820+10 K<820+540820+540
Figure 12
11
100 12 0 140 1 60 180 200 220 240 260 280 300
100 120 140 160 180
200 220 240 260 280 300
mmmm
Max 120° Max 110° Max 100° Max 90°
A
Figure 13
Note: Value B must be close to or equal to the value A to obtain the best mechanical advantage.
Installation direction: door open facing outward (Magro - 650 J)
B
Note:Note: SatetySatety blockblock mustmust bebe installed,installed, isis proviedprovied byby installerinstaller
K
L=820+10L=820+10 K<820+540820+540
B
A
L
Note:Note: SafetySafety stopperstopper mustmust bebe installedinstalled
Figure 14
12
100 120 140 160 180 200 220 240 260 280 300
100 120 140 160 180 200 220 240 260 280 300
mmmm
Max 90° Max 100° Max 110° Max 120°
A
Figure 15
Note: Value B must be close to or equal to the value A to obtain the best mechanical advantage.
4.3.4 Size of control box
B
210
Figure 16
127.5
275
Warnings
·To ensure safety, when door open facing outward, the safety block must be installed at the OPEN limit position to prevent the door opening angle from exceeding the machine range; the safety stopper must be installed at the CLOSE limit position, to make two doors stopping at the CLOSE limit position accurately (as shown in figure 10, 14). When door open facing inward, the safety stopper must be installed at the CLOSE limit position (as shown in figure 8, 12).
·Before installing the main engine, make sure that the main engine and components are in good mechanical performance and that the door can be operated manually.
·One control unit can control driving one main engine or two main engines.
·Earth leakage circuit breaker must be installed where the gate movement can be seen, and the minimum mounting height of control box is 1.5m to protect it from being touched.
·After installation, please check whether the mechanical property is good or not, whether gate movement after manual unlocking is flexible or not, and whether the infrared sensor (optional) is installed correctly and effectively.
4.3.5 Control board wiring
AlarmAlarm lamplamp
MainMain engineengine 1
MainMain engineengine 2
ElectricElectric locklock
+24VDC+24VDC
CommonCommon terminalterminal
InfraredInfrared protectionprotection
15VDC15VDC
DoorDoor closeclose buttonbutton CommonCommon terminalterminal
Open/Stop/closeOpen/Stop/close controlcontrol buttonbutton
CommonCommon terminalterminal
SingleSingle doordoor openopen buttonbutton
TestTest buttonbutton
LearningLearning buttonbutton
PK300DC M-2PK3 00DCM-2
RY5RY5
LIGHTLIGHT
DCDC24V24V
MOTORMOTOR 1 MOTORMOTOR 2 LOCKLOCK
M1M2
IN5408IN5408
IRIRCOMCOM+PWR+PWR
+
-
15V15V
P.SWP.SW P.SWP.SW
OPOP
CLCL
1
2
LED8LED8
LED7LED7
LED6LED6
CLCL
OPOP
VX1VX1
LED3LED3
LED4LED4
OPOP
CLCL
VX2VX2
RY8RY8
LED2LED2
LOCKLOCK
6.2V6.2V
D20D20
LED7LED7
CN4CN4CN3CN3CN2CN2
CN5CN5
SENSORSENSOR
C8C8
U2U2
U3U3
78L0578L05
C11C11
U4U4
TESTTEST
D11D11 D10D10
6A106A10
6A106A10
C2C2 C1C1
470UF470UF 470UF470UF
10UF10UF
C4C4
RY1RY1RY1RY1RY2RY2
RY4RY4
10UF10UF
C4C4
RY6RY6
D13D13
6A106A10
D12D12
6A106A10
U5U5 78127812
Q2Q2
MOTOR1MOTOR1 MOTOR2MOTOR2
Q3Q3
AN1AN1
RX1RX1
IC2IC2
F1F1
LEARNLEARN
ACAC FUSEFUSE
LED1LED1
U1U1
C3C3
78157815
10A10A
POWERPOWER
ACAC
VR1VR1
VR2VR2
D14D14
6A106A10
FUSEFUSE
8A8A
LM317LM317U6U6
15A15A
+BATTERY-+BATTERY-
REVREV
24VAC24VAC
BattaryBattary
Figure 17
Wiring instruction:
POWER AC terminal 24VAC alternating current power.
BATTARY- terminal Storage battery.
8P terminal:
LIGHT Alarm lamp (24VDC);
MOTOR 1 Main engine 1; MOTOR 2 Main engine 2; LOCK Electronic lock (24VDC).
CN2 terminal:
PWR Power supply for fittings +24VDC;
COM Common;
IR Input of infrared sensor (N.C.).
CN3 terminal: Power supply for fittings 15VDC.
CN4 terminal: Signal input of gate close control button;
Control button common terminal.
CN5 terminal: Open/Stop/Close/Stop loop control button;
Control button common terminal;
Single door opening button.
Transformer wiring
ACAC FUSEFUSE
D12D12D13D13
LED1LED1
U1U1
C3C3
78157815
10A10A
U5U5
78127812
TransformerTransformer outputoutput 24VAC24VAC
POWERPOWER
ACAC
MOTOR1MOTOR1 MOTOR2MOTOR2
VR1VR1 VR2VR2
D14D14
6A106A10
TransformerTransformer inputinput
FUSEFUSE
220VAC/110VAC220VAC/110VAC
8A8A
LM317LM317U6U6
15A15A
RX1RX1
F1F1
+BATTERY-+BATTERY-
REVREV
15
DIP switch
Dial Function
1 Door closing delay function:
ON: Enabled - Motor 2 is 5 seconds delay to close the door than Motor 1; OFF: Disabled.
2 Door opening status:
ON: Enabled - Motor 1 and motor 2 conduct 0.5-second close action before open the door; OFF: Disabled.
3 Single / Double door mode:
ON: Single door mode; OFF: Double door mode.
4 /
Automatic close function:
5
5 ON 6 ON——Automatic close time is 60s; 5 ON 6 OFF——Automatic close time is 10s;
6
5 OFF 6 ON——Automatic close time is 5s; 5 OFF 6 OFF——No automatic close function.
Adjusting knob
Adjust the sensitivity of meet obstacle: clockwise adjusting VR1 can reduce sensitivity of obstacle of the motor 1; clockwise adjusting VR2 can reduce sensitivity of obstacle of the motor 2.
Infrared connection
Infrared photocell function: In the closing process, when infrared ray of the infrared sensor is
covered, the gate will open immediately, to protect user and property security.
The distance between photocell receiver and photocell emitter should be not less than 2 meters,
otherwise will affect the induction of the photocell.
If connect the infrared photocell, please remove the short connection between IR and COM on the
CN2 terminal.
16
InfraredInfrared receiverreceiver connectingconnecting
- +
ComCom OutOut
SETSET NCNC
InfraredInfrared emitteremitter connectingconnecting
- +
LOCKLOCK
IRIRCOMCOM+PWR+PWR
15V15V
P.SWP.SW P.SWP.SW
OPOP
CLCL
1
2
IN5408IN5408
D20D20
LED7LED7
CN2CN2 CN3CN3
CN5CN5
SENSORSENSOR
TESTTEST
Figure 19
Adjustment and operation Remote control operation
Remote control is single button mode, one same button on the remote control to circularly control
the main engine OPEN/STOP/CLOSE/STOP.
OPENOPEN
CLOSECLOSE
STOPSTOP
A
B
C
D
Figure 20
17
Add extra remote control (remote control learning): Remove the upper cover of main engine; press the learning button S1 on the control board, and indicator light LEARN will flash once and then go out; press the same button on the remote control twice, the LEARN flashes repeatedly and then goes out; remote control learning is succeed. At most 25 remote controls can be learned. Delete remote control: Delete remote control that have been learned; press the learning button S1 and LEARN will be on; loosen the button until LEARN is off. This indicates that all remote controls that learned previously have been deleted.
Note: Unlock the door opener, move the door to the middle position, reversely rotate the manual release bar to lock, electrify and then press TEST button after relay restoration, the door would automatically operate once, LED4 LED6 on the control panel is the door-opening indicator light that shows green; LED3 LED6 is the door-closing indicator light that shows red. If the opening-closing direction is incorrect, the direct-current motor wire could be exchanged to alter the moving direction of the electrical machine.
Battery connection:
ACACFUSEFUSE
D12D12D13D13
LED1LED1
U1U1
C3C3
78157815
10A10A
U5U5
POWERPOWER
ACAC
78127812
MOTOR1MOTOR1 MOTOR2MOTOR2
VR1VR1 VR2VR2
D14D14
6A106A10
FUSEFUSE
8A8A
LM317LM317U6U6
15A15A
RX1RX1
F1F1
+BATTERY-+BATTERY-
REVREV
StorageStorage batterybattery
Figure 21
18
SolarSolar
panelpanel
Solar panel connection:
ACACFUSEFUSE
D12D12D13D13
LED1LED1
U1U1
C3C3
78157815
10A10A
U5U5
POWERPOWER
ACAC
78127812
MOTOR1MOTOR1 MOTOR2MOTOR2
VR1VR1 VR2VR2
D14D14
6A106A10
FUSEFUSE
8A8A
LM317LM317U6U6
SolarSolar chargercharger
CHARGECHARGE LOADLOAD
+ - + - + -
BATTERYBATTERY
15A15A
RX1RX1
F1F1
+BATTERY-+BATTERY-
REVR EV
StorageStorage batterybattery
Figure 22
5. Others
5.1 Maintenance
Check whether the gate operates normally every month. For the sake of safety, each gate is suggested to be equipped with infrared protector, and regular inspection is required. Before installation and operation of the gate opener, please read all instructions carefully. Our company has the right to change the instruction without prior notice.
19
transformer power is normal,
5.2 Troubleshooting
Problems Possible Reasons Solutions
The gate cannot open or close normally, and LED does not light.
The gate can open but cannot close.
Remote control doesn’t work.
Press OPEN, CLOSE button, the gate is not moving, motor has noise.
1.The power is off.
2.Fuse is burned.
3.Control board power wiring with problem.
1.Photocell wiring with problem.
2.Photocell mounting with problem.
3.Photocell is blocked by objects.
4.Sensitivity of obstacle is too high.
1.Battery level of the remote control is low.
2.Remote control learning is not completed.
Gate moving is not smoothly.
1.Switch on the power supply.
2.Check the fuse, change the fuse if burnt.
3.Re wiring according to instructions.
1.If not connect photocell, please make sure that the IR and COM short circuit; if connect infrared sensor, please make sure the wiring is correct and the photocell is N.C.
2.Make sure that the photocell mounting position can be mutually aligned.
3.Remove the obstacle.
4.Reduce the sensitivity of obstacle.
1.Change the remote control battery.
2.Re-conduct remote control learning.
According to the actual situation to adjust the motor or the gate.
Leakage switch tripped.
Remote control working distance is too short.
The gate moves to the middle position to stop or reverse.
Power supply line short circuit or motor line short circuit.
Signal is blocked.
1.Motor output force is not enough.
2.Sensitivity of obstacle is too high.
3.Gate meets obstacle.
Check wiring.
Connect external receiver antenna, 1.5 meters above ground.
1.Check whether the
if not, change the transformer.
2.Adjust the VR1, VR2.
3.Remove the obstacle.
Loading...