Autoflo 250, Sc-15 Owner's Manual

FOR USE WITH GAS, OIL, and HYDRONIC FORCED AIR FURNACES
Installation Instructions
Owner’s Manual
MODEL SC-15 & MODEL 250
FLOW-THRU HUMIDIFERS
SEQUENCE OF OPERATION
The AUTOFLO Model’s SC-15 & 250 use the evapo rative principal to add moisture to the warm air heat ing system. Upon a demand for humidity from the humidity control, the water solenoid valve opens and water flows in at the top of the media pad and is evaporated, as warm air passes through the media pad. When the moisture laden air re-enters the duct it is mixed with dry air already flowing through the duct. This moisture laden air gradually increases the relative humidity level in the home.
RECOMMENDED LOCATION
TEMPERATURE AND SAFETY REQUIREMENTS
Refer to the rating plate on the furnace for minimum clearances to combustible construction. All parts and connections of an AUTOFLO humidifier must be installed outside of the minimum clearance requirements for rear, top, sides, and flue of furnace. Do not install where humidifier or water connections may be exposed to freezing temperatures or outside weather. Attic installations are NOT recommended. If you have central air conditioning, carefully plan the location of the plenum opening to prevent damage to the cooling coil or other components inside the duct.
STEP BY STEP INSTALLATION
-
-
CAUTION: Installation should be performed by qualified personnel only. Use eye protection and gloves when drilling and handling sheet metal. All work must be performed to local & national codes and ordinances. Use multi-conductor 18 awg solid copper wire. Provide over-current protection as required. DO NOT omit the drain or overflow tubing.
MODEL SC-15
Turn off power to the furnace before installing the humidifier. Test fit the SC-15 housing on the side of the warm air plenum. Before proceeding, verify that adequate clearances are available for servicing the media pad. There must also be adequate room (5 1/2 inches) inside the plenum for the louver. If necessary, relocate the unit. Use a plumb line or a level to make sure the housing is level. With a permanent marker outline the inside edge of the housing. Also mark the twelve holes to be drilled. Center punch and drill all twelve holes as indicated by the marks. Drill or punch a starter hole and then use tin snips to cut out the rectangular shaped open ing. The opening should be 1/8 inch larger on all four sides than what was marked.
-
HUMIDIFIER MOUTING LOCATION
The AUTOFLO model SC-15, is to be mounted on the supply duct of the furnace only. Model 250 can be mounted on the supply or the return duct of the furnace.
HUMIDISTAT MOUNTING LOCATION
The humidistat can be mounted on the cold air return duct to sense the cool dry air returning to the furnace. It can also be mounted on an interior wall near the furnace thermostat as well. The electrical connections and basic wiring are the same for duct mounted or wall mounted humidistats.
TB 218 Part#090375A0218 Rev. B 12122006SC15250
®
281 Keyes Ave. Hampshire, IL 60140 • 847-683-7990 • Fax 847-683-7301 • www.bestairpro.com
Copyright 2007 © , All Rights Reserved
MOUNTING HUMIDIFIER
Hold the housing next to to duct and start four #8 x 3/4 inch long sheet metal screws through the holes in the bottom edge of the humidifier. With these four screws started the unit should remain in place while starting the other eight screws. With all twelve of the screws started they can now be tightened. With the housing mounted the louver can be installed. This should be done by rotating the louver to the proper position depending on the direction of air flow. The air flow should enter into the curved multi-louvers and exit out of the large opening.
®
1
SC-15
Horizontal flow
Blower Motor
Place Baffle Here
BY PASS
SC-15 mounts
e supply
to th duct only.
Up Flow
Side Cutaway View Model SC-15 mounted on the supply plenum of an Upflow Furnace
SC -15
DRILL MOUNTING HOLES AND CUT OPENING MODEL 250
Supply Duct
250
R etur n D uc t
Up Flow
Horizontal flow
250
250
Supply Duct
Down Flow
Return Duct
Mount the model 250 using all the same precau­tions as in mounting the SC-15. Use the mounting template to locate the humidifier on the duct work. Tape down the template for the humidifier and for the by pass duct adaptor. Drill and cut all holes that go with each template. Mount the adaptor and the baffle with the (6) 3/8” screws from the kit. Mount the humidifier by first putting in the bottom of the humidifier housing to catch the lip on the back of the housing. Then use the (10) 1/2” screws that come in the kit to mount the housing to the duct. Install the field supplied bypass duct and end cap. First route the bypass duct from the duct adaptor to one side of the humidifier housing. Drill 2 holes through the bypass duct and the duct adaptor. Install (2) 3/8” screws from the kit on each end of the humidi
­fier housing. There are pre-punched holes. Use them to line up and mount the bypass duct and end cap with (2) 1/2” screws from the kit. Open the Bypass Baffle during the winter and close it during the summer.
Mounting the Model 250
Model 250 Bypass baffle and duct adaptor.
®
281 Keyes Ave. Hampshire, IL 60140 • 847-683-7990 • Fax 847-683-7301 • www.bestairpro.com
Copyright 2007 © , All Rights Reserved
®
2
MODEL SC-15
PARTS LIST
Unpack the Autoflo model SC-15 humidifer and familiarize yourself with the following parts:
1. Model SC-15 Humidifier
2. Small parts bag containing: a. Two #8 x 3/4” sheet metal screws b. Twelve #8 x 3/8” sheet metal screws
3. Saddle tapping valve kit
4. 24 volt humidistat
5. 24 volt transformer
6. 1/2” drain hose
7. 1/4” plastic tubing
8. Evaporative media pad
9. Owner’s manual
ADDITIONAL RECOMMENDED PARTS
1. Relay, with 120 volt current sensing coil for furnaces with multi-speed blower motors.
2. 4x4 wire box to mount transformer and enclose line voltage connections.
3. #18awg thermostat wire to make up any and all 24 volt connections
4. 1/2” drain hose clamp.
®