Autodesk COMBUSTION-4 - Acad Full-seat Windows Version, Combustion 4 discreet Network Manual

11 March 2005
© Copyright 2005 Autodesk Canada Co./Autodesk, Inc. All Rights Reserved.
This publication, or parts thereof, may not be reproduced in any form, by any method, for any purpose.
AUTO DESK CA NADA CO ./AUTO DE SK, INC. MAKE S NO WAR RA NTY, EITHER EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES, OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, REGARDING THESE MATERIALS AND MAKES SUCH MATERIALS AVAILABLE SOLELY ON AN “AS-IS” BASIS.
IN NO EVENT SHALL AUTODESK CANADA CO./AUTODESK, INC. BE LIABLE TO ANYONE FOR SPECIAL, COLLATERAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING OUT OF PURCHASE OR USE OF THESE MATERIALS. THE SOLE AND EXCLUSIVE LIABILITY TO AUTODESK CANADA CO./AUTODESK, INC., REGARDLESS OF THE FORM OF ACTION, SHALL NOT EXCEED THE PURCHASE PRICE OF THE MATERIALS DESCRIBED HEREIN.
Autodesk Canada Co./Autodesk, Inc. reserves the right to revise and improve its products as it sees fit. This publication describes the state of this product at the time of its publication, and may not reflect the product at all times in the future.
Autodesk, Inc. Trademarks
The following are registered trademarks of Autodesk, Inc./Autodesk Canada Co. in the USA and/or other countries: 3D Props, 3D Studio, 3D Studio MAX, 3D Studio VIZ, 3DSurfer, 3ds max, ActiveShapes, ActiveShapes (logo), Actrix, ADI, AEC Authority (logo), AEC-X, Animator Pro, Animator Studio, ATC, AUGI, AutoCAD, AutoCAD LT, AutoCAD Map, Autodesk, Autodesk Inventor, Autodesk (logo), Autodesk MapGuide, Autodesk University (logo), Autodesk View, Autodesk WalkThrough, Autodesk World, AutoLISP, AutoSketch, backdraft, Biped, bringing information down to earth, CAD Overlay, character studio, Cinepak, Cinepak (logo), cleaner, Codec Central, combustion, Design Your World, Design Your World (logo), discreet, EditDV, Education by Design, fire, flame, flint, flint RT, frost, glass, gmax, Heidi, HOOPS, Hyperwire, i-drop, inferno, Inside Track, Kinetix, lustre, MaterialSpec, Mechanical Desktop, mountstone, NAAUG, ObjectARX, PeopleTracker, Physique, Planix, Powered with Autodesk Technology (logo), RadioRay, Revit, riot, river, smoke, Softdesk, sparks, stone, stream, Texture Universe, The AEC Authority, The Auto Architect, vapour, VISION*, Visual, Visual Construction, Visual Drainage, Visual Hydro, Visual Landscape, Visual Roads, Visual Survey, Visual Toolbox, Visual TugBoat, Visual LISP, Volo, WHIP!, and WHIP! (logo), wire.
The following are trademarks of Autodesk, Inc., in the USA and/or other countries: AutoCAD Architectural Desktop, AutoCAD Learning Assistance, AutoCAD LT Learning Assistance, AutoCAD Simulator, AutoCAD SQL Extension, AutoCAD SQL Interface, Autodesk Map, Autodesk Streamline, AutoSnap, AutoTrack, backburner, Built with ObjectARX (logo), burn, Buzzsaw, Buzzsaw.com, Cinestream, cleaner central, ClearScale, Colour Warper, Content Explorer, Dancing Baby (image), DesignCenter, Design Doctor, Designer's Toolkit, DesignProf, DesignServer, Design Web Format, DWF, DWG Linking, DXF, Extending the Design Team, GDX Driver, gmax (logo), gmax ready (logo), Heads-up Design, IntroDV, jobnet, lustre, Multi­Master Editing, ObjectDBX, onscreen onair online, Plans & Specs, Ppasma, PolarSnap, ProjectPoint, reactor, Real-time Roto, Render Queue, Visual Bridge, Visual Syllabus, and Where Design Connects.
All other brand names, product names, or trademarks belong to their respective holders.
Government Use
The software and documentation is provided with RESTRICTED RIGHTS. Use, duplication, or disclosure by the United States Government or any agency, department or instrumentality thereof is subject to the restrictions set forth in the Commercial Computer Software—Restricted Rights clause at FAR 52.227-19 or the Commercial Computer Software—Licensing clause at NASA FAR Supplement 1852.227-86. Manufacturer is Autodesk Canada Co./Autodesk, Inc., 10, Duke Street, Montreal, Quebec, Canada, H3C 2L7.
Titl e: combustion® 4 Network Administrator’s Guide for Microsoft® Windows®
Par t Numb er: NA
Software version: 4
Document version: 4.0
Date: 11 March 2005

Table of Contents

1Requirements 1
System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Network Installation Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Network Planning Concepts 5
Network Configuration Models. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
AdLM Network Communication Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
License Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3 Installation 13
FLEXlm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Setting up the Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Silently Installing combustion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4 License Server Configuration 19
Obtaining the Server Host Name and ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Obtaining and Setting Up a License File. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Configuring the Server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5 Administration 23
License Server Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Using the FLEXlm Configuration Tools. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Using the License Configuration Switcher. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
iii
toc
Table of Contents
6 Networking Quick Start and Troubleshooting 27
FLEXlm Defined. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Obtaining Authorization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Identifying the Server Name and Host ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Handling the License File Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Configuring the FLEXlm Server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Troubleshooting Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
AGlossary 35
iv

Requirements

Summary
System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Network Installation Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1
1
Requirements
The Network Administrator’s Guide gives you
the information you need to deploy
combustion® from a network location. This
chapter describes the system requirements and
network installation components required for
installing, authorizing, and configuring
combustion on a network.

System Requirements

Before you begin installing combustion on a
®
network using the Autodesk (AdLM), ensure your network, servers, and client workstations meet the minimum recommended requirements for network installation. Refer to the follow ing table for the server hardware and software requirements.
License Server
Hardware / Software
Operating system
Network interface card
Communication Protocol
Requirements Notes
Windows NT®, Windows 2000, or Windows XP
Compatible with current Ethernet network infra­structure
TCP/IP By default, AdLM
Licensing Manager
AdLM supports Ethernet network configurations only.
AdLM supports multiple network interface cards.
uses TCP packet types. Optionally, you can configure UDP packet types.
Refer to the following table for the client workstation minimum recommended hardware and software requirements.
Client Workstation ­combustion
Hardware / Software
Processor Intel® Pentium® III,
Operating system
Hard drive 20 GB main hard drive,
RAM 256 MB
Video Video display card
CD-ROM Any speed For installation only.
Network inter­face card
Web browser Microsoft Internet
Requirements Notes
Pentium 4, or AMD® Athlon™ XP
Microsoft 2000 or Windows XP
approximately 142 MB free space
®
Windows
CPU, 850 MHz or higher.
It is recommended that you install and run an on an English version of the operating system. You must have Administrator permissions to install Not assigning these permissions can cause and third-party applications to perform incorrectly. See Windows Help for information about assigning user permissions.
See the
4
Installation Guide
for details.
— —
with 32 MB of VRAM (1024x768 display with 24-bit color minimum required)
Compatible with current Ethernet network infrastructure
Required for installing and running network versions of
combustion
Explorer 6 or later
combustion
combustion
combustion
combustion
.
on
.
2

Network Installation Components

❚❘❘
Client Workstation ­combustion
Hardware / Software
Optional Modem or access to
Requirements Notes
an Internet connection
Network Installation Components
To de pl oy a n d c o nf i gu re combustion on a network, the following network installation components are required. These are included on the combustion 4 installation CD.
Autodesk License Manager (AdLM)
FLEXlm™ Tools
combustion License Configuration Switcher
SAMreport-Lite (optional); for information about
SAMrepor t-Lite, refer to the online samlite_ug.chm file located on the combustion 4 installation CD, in the Network Licensing\Manuals folder.

Autodesk License Manager

The Autodesk License Manager (AdLM) provides authorization for clients running combustion on a network. The AdLM also contains tools for network administrators that provide query and tracking capabilities. For authorizing combustion on a network, double-click setup.exe in the Network Licensing directory on the combustion 4 installation CD and follow the AdLM installer instructions on the screen.
See “License Management” in Chapter 2, “Network
Planning Concepts’’.

FLEXlm Tools

The AdLM uses FLEXlm technology from Macrovision® to manage network licenses. FLEXlm provides administrative tools that help simplify management of network licenses. You can use FLEXlm tools to monitor network license status, reset licenses lost to a system crash, troubleshoot license servers, and update license files on the fly.
See “Using the FLEXlm Configuration Tools” in
Chapter 5, “Administration’’.

combustion License Configuration Switcher

You use the combustion License Configuration Switcher (LicenseSwitcher.exe) located in the same directory as the combustion.exe to allow a workstation to use either a network license or a standalone license. For example, users running a network license of combustion on a network workstation can use the combustion License Configuration Switcher to switch their license configuration to a standalone configuration and take work on the road. When they return, they can switch back to a network license configur ation. With the combustion License Configuration Switcher, users can remain productive while their computer is detached from the network. Using the combustion License Configuration Switcher does not convert a network license to a standalone license. It only changes the method combustion uses to get its license. See “License Management” in Chapter 2,
“Network Planning Concepts’’.
See “Using the License Configuration Switcher” in
Chapter 5, “Administration’’.
3
1
Requirements

SAMreport

While not part of the network installation, a version of SAMreport called SAMreport-Lite™ is included in the Network Licensing folder on the combustion 4 installation CD to help you track network license usage. With SAMreport-Lite technology from Macrovision, you can monitor client usage for all software that uses FLEXlm to manage network licenses.
SAMreport-Lite generates usage reports in a variety of output formats, including HTML, text, and Report Interchange Format.
For more information about the SAMreport-Lite features and for instructions on installing SAMreport-Lite, see the online help file samlite_ug.chm included on the combustion 4 installation CD in the Network Licensing\Manuals directory.
For additional information about SAMreport-Lite, and for updates and fixes for this feature, visit the Autodesk website at:
samreportlite
www.autodesk.com/
.
4

Network Planning Concepts

Summary
Network Configuration Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
AdLM Network Communication Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
License Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5
2
Network Planning Concepts
This chapter explains concepts related to
installing and operating combustion on a
network.

Network Configuration Models

Installing combustion on a network requires careful planning. The type of installation you choose to deploy can differ depending on your network infrastructure and requirements for client use. The network configuration model you choose to implement determines where the components that combustion requires for a network installation are installed in your network environment.
Before you choose the appropriate network configuration for your users, you must determine how you want to deploy combustion and which components you need to deploy on a network.
Most deployment types require two components:
the AdLM and the deployment on the same server or on separate servers.
The network server model you choose for your installation determines where each component resides on the network. The server model you choose is based on the structure of your network, the number of users, and your performance requirements. It can determine how well combustion performs in your network environment and the length of recovery time in the event of a network problem.
Another important aspect of a deployment to consider is data sharing. One of the key benefits of a deployment is that users can share data. When you plan a deployment, consider the requirements for sharing data and the network resources (such as shared folders) when choosing your deployment type and server model.
combustion supports the single server model, the distributed server model, and the redundant server model.
Autodesk License Manager (AdLM)
Installing, authorizing and starting the AdLM is the first component of any network installat ion of combustion. The AdLM and related files (located on a network share) control available licenses used by combustion. A user can run combustion only if a license is available. The AdLM is required for all deployment types.
Deployment location
Creating and installing the deployment is the second component of any network installation of combustion. A deployment is a shared network resource where a preconfigured combustion setup program resides. A user installs combustion from a deployment on the network onto each workstation. A deployment location is required for all deployment types. You can store
6

Single Server Model

With the single server model, all license management takes place on a single server. Since all license management takes place on a single server, this configuration requires the least amount of maintenance.
To create a deployment using the single server model, you run the AdLM on the server you want to configure and store the deployment on the same server.
Network Configuration Models
❚❘❘

Distributed Server Model

The distributed server model is the preferred method of installing combustion in a network environment. The distributed server model allows you to place (distribute) the AdLM on more than one server. This lets you split your software licenses between multiple servers. The servers can be located at different sites, if necessary.
The distributed server model gives you more network tolerance. Since the software licenses are split among multiple servers, licenses can still be granted should one of the servers fail or run out of licenses. In addition, a distributed server requires less system administration than a redundant server model. However, if a server fails, some licenses are not available. This drawback can be resolved by adding the variable to each client workstation.
To create a deployment using the distributed server model, you install the AdLM on each server you want to configure.
This model requires a unique license file for each server. See License File
Once the network installation is complete, you install combustion on each workstation. The client installation creates a combustion.lic file on the client workstation that identifies which license server the client communicates with to obtain a network license. The client workstation tries to obtain a network license only from the server that was configured when the AdLM created the deployment location from which the client was installed.
Adding the variable to each client workstation is necessary if you want to have license carr yover. This is a key strength of the distributed server model. It allows the client workstation to automatically obtain a license from another server in the distributed server pool if one server should fail or run out of licenses.
lm_license_file environment
.
lm_license_file environment
For example, if you installed a distributed server pool of two servers, each server has a license file for five combustion licenses. You then create six client installations that use the default combustion.lic file pointing to the first server. If all the licenses on the first server are in use, the sixth workstation that tries to obtain a license from the server will be denied, even when the second server in the pool has five available licenses.
You have two options to get the sixth workstation a license:
Edit the combustion.lic file so the sixth workstation looks exclusively to the second server for its license.
Note:
Using this method does not give you the
benefit of network tolerance.
Add the lm_license_file environment
variable to all the workstations so the AdLM can access any available licenses on either server. See
License File Parameters
Note:
If the
combustion.lic
lm_license_file
used, the environment variable takes priority.
.
file and the
environment variable are both

Redundant Server Model

With the redundant server model, you must use three servers to authenticate a single license file. One server acts as the master, while the other two provide backup if the primary server fails. If all three servers are active and functioning properly, all software licenses are available to client workstations. A redundant server model does have some drawbacks you need to consider:
A redundant server model should be maintained by a dedicated system administrator.
At least two servers must be functional in order for client workstations to obt ain licenses. If two servers fail, client workstations cannot get licenses.
7
2
Network Planning Concepts
Since the redundant server model is more
susceptible to network failure, all servers must reside on the same subnet and have consistent network communications. All servers must be located on the same site.
Slow, erratic, or dial-up connections are not recommended when using the redundant server model.
The redundant server model does not support the UDP packet type.
To create a redundant server pool, run the AdLM installation on the initial server you want to configure, then repeat the AdLM installation for the other two servers. To get proper license authorization, you must obtain the Host ID and server name for each server in the redundant server pool before contacting Autodesk. For additional information, see “Obtaining the Server Host Name
and ID” in Chapter 4, “License Server Configuration’’.
Once all client workstations are installed and communicating with the license server, you must modify the combustion.lic file on each client workstation to include server information for each of the three servers. Following is an example of the contents of the combustion.lic file:
SERVER PC54321 210987654321
USE_SERVER
Following is an example of a combustion.lic file modified for a redundant server operation:
SERVER PC54321 210987654321 27005
SERVER PC12345 123456789012 27005
SERVER PC32154 321543210981 27005
USE_SERVER
The redundant server model requires a port number (the default is 27005) for each server.
The port number at the end of each SERVER line must also be included in the license file for the redundant server model only.
The redundant server model requires Windows 2000 Server Edition.
Note:
Windows 2000 Workstation edition is not
supported as license servers.
The redundant server model also requires that separate copies of the same license file, license manager daemon (lmgrd), and vendor daemon reside on each server; all are necessary to authenticate and release licenses.
If the redundant server configuration fails, it might be necessary for the system administrator to start the license server on each of the redundant server machines within a few minutes of one another.

AdLM Network Communication Protocol

Once you have chosen your preferred installation configuration, you have the option of using either the TCP/IP or UDP packet types. The AdLM uses the standard network protocol—Transport Control Protocol/Internet Protocol (TCP/IP) packets by default. TCP sends data between applications whereas IP communicates data between an application and the physical network.
There is a 10-connection TCP/IP limit with Windows 2000/Windows XP Professional editions. The Windows 2000 and Windows XP Server editions do not have the 10-connection limitation, so they are the preferred Operating systems. If you have more than 10 client workstations that need to access a single license server and you do not have a Server edition of Windows, then use UDP as the default packet type. UDP requires more extensive configuration at servers and clients.
8

License Management

❚❘❘
combustion does not support the redundant server model if you choose to use UDP as your primary packet type with UDP packet transmission.
To use UDP packets, you must set the environment variable FLEXLM_COMM_TRANSPORT UDP on each client workstation.
License Management
Rather than purchasing a single-user license for every combustion user or workstation, you can purchase a network license for a maximum number of concurrent users, and purchase additional licenses as needed.
combustion uses either TCP (default) or UDP packets to communicate with the AdLM. You can’t configure combustion to use both packet types simultaneously. The packet type you use depends on your network environment and the number of clients assigned to a specific server.

License Operation and Availability

When a user starts combustion, the application reads the combustion.lic file located on the client workstation to determine which server it should try to obtain a license from. combustion then sends a message to the AdLM server listed in the combustion.lic file through the network protocol and requests a license. If the number of available licenses has not exceeded, the AdLM assigns a license to the user. The combustion session then starts on the workstation, and the number of available licenses is reduced by one.
The client and server communicate at regular intervals to keep track of licenses in use and manage license availability.
When a user exits combustion, the AdLM frees a license for another user. Multiple sessions on an individual workstation use only one license. When the last session is closed, the license is freed.
The following three processes direct license management:
License manager daemon (lmgrd.exe)
Handles the original contact with the application, then passes the connection to the vendor daemon. Lmgrd is used to communicate with the vendor daemon only and does not authenticate or dispense licenses, it passes user requests on to the vendor daemons. By using this approach, a single lmgrd daemon can be used by many different software vendors to provide license authentication. Lmgrd starts and restarts the vendor daemons as needed.
Autodesk vendor daemon (adskflex.exe)
Contains the server process that releases licenses. The vendor daemon keeps track of the licenses that are checked out and which clients are using them. Each vendor has a unique vendor daemon to manage vendor-specific licensing. adskflex.exe is specific to Autodesk products only. If the vendor daemon terminates for any reason, all users lose their licenses until lmgrd restarts the vendor daemon or the problem causing the termination is resolved.
License file
license information.
—A text file that has vendor-specific
If you use environment variables in a distributed or redundant server environment, these variables take precedence over the settings in the combustion.lic file.
9
Loading...
+ 29 hidden pages