Australian Monitor. SY 6125, SY 400, SY 400V, SY 800V, SY 1200 User Manual

...
Professional Audio Amplifier
SY 400
SY 800 SY 1200 SY 1600
SY 400V SY 800V
SY 6125 SY 4200
Operation Manual
IMPORTANT!
Please read carefully.
This operation manual contains important information regarding safety precautions, installation, performance, operation and maintenance of your Synergy-Series power amplifier. You should familiarize yourself with the contents of this manual operating your amplifier.before
Safety Precautions
and Labelling
The rear panel of this amplifier has a number of markings and internationally recognized symbols relating to the hazards and precautions that should be taken when operating MAINS connected equipment.
The presence of a LIGHTNING FLASH with an arrowhead contained within the boundaries of an equilateral triangle is intended to alert the user that dangerous uninsulated voltages may exist within the amplifiers enclosure. These voltages may be of a sufficient magnitude as to constitute the risk of an electrical shock.
This symbol is reinforced with the text:
!CAUTION!
RISK OF ELECTRICAL SHOCK
DO NOT OPEN
REFER SERVICING TO
QUALIFIED PERSONNEL.
NO USER SERVICEABLE
PARTS INSIDE.
The user should not attempt to service the amplifier. Only qualified and knowledgeable personnel familiar with the internal workings of the unit should attempt any repair, servicing or authorized modificationto the unit. The unit does not contain any parts which the user can service or re-use in this or any other product.
If you are in need of special assistance and the information you require is outside the scope of this manual, please contact your nearest service agent orAustralian Monitor direct:
THE TECHNICAL OFFICER
AUSTRALIAN MONITOR
C/- AUDIO TELEX COMMUNICATIONS PTY LTD
PRIVATE BAG 149,
SILVERWATER. N.S.W. 1811
AUSTRALIA.
!WARNING!
DO NOT EXPOSE TO EITHER
RAIN OR MOISTURE
The amplifier should not be operated in a situation where it may encounter the entry of water, rain, or any fluids. To expose the unit to the above conditions may make the operation of the unit hazardous and increase the risk of electrical shock.
Phone Fax Local (02) 9647-1411 (02) 9748-2537 International 61-2-9647-1411 61-2-9748-2537
Email ho@audiotelex.com.au Internet www.australianmonitor.com.au
Rev 2 16/06/04 Rev 3 26/06/04 Rev 4 28/06/04 Rev B 28/06/04
Features:
>
Custom designed, 2RU heavy duty steel chassis.
Open, modular construction for ease of
>
servicing.
Symmetrical layout - even weight distribution.
>
High current power supply.
>
High efficiency toroidal mains transformer.
>
Binding post and 4 pole speaker output
>
connection (no 4 pole speaker outputs on SY400V, SY800V, SY4200 & SY6125).
Stereo or bridged operation (no bridging
>
available on SY400V & SY800V).
Input signal strapping (loop through) connectors
>
(not available on SY6125).
>
Balanced inputs and buffered attenuators.
1 Watt output indication (2.828 volts).
>
1 dB below output clip indication.
>
Efficient front to back cooling.
>
Dual, twin speed axial fans.
>
Multi-role output fault indication.
>
Front carry handles. Rear rack mount ears.
>
Signal ground lift switch.
>
Built in limiter circuit.
>
High-quality, close-tolerance components
>
throughout.
Protection Features
>
Suppression of inrush current at mains turn-on.
Input muting at turn-on.
>
Input overvoltage protection.
>
Radio-frequency interference suppression.
>
Short-circuit protection and indication.
>
High overload mains fuse.
>
Austr alian Monitor
>
Internal, independent DC supply rail fuses.
Layout, grounding, decoupling and componentry
>
have been optimized to provide the user with
, and .stability reliability longevity
Contents
Page
1. Introduction 5
2. Controls, Connectors and Indicators 6
2.1 Front Panel 7
2.2 Rear Panel 11
3. Installation 14
4. Operation 16
5. Maintenance 18
6. Specification 20
List of Illustrations
Page
Figure 1. Block Diagram 5
Figure 2. Front Panel Layout(SY6125, SY1200, SY4200) 6
Figure 3. Rear PanelLayout (SY400, SY1600) 9
Figure 4. Rear PanelLayout (SY6125, SY4200, SY400V) 10
Figure 5.Top Lid Layout (SY6125, SY4200) 13
Figure 6. Speaker Connector Wiring 15
1. Introduction
Introduction 5
Congratulations on choosing Australian Monitor for your professional amplification requirements.
The design of our Synergy-Series Audio Power Amplifiers embraces all the aspects of a well designed amplifier. The visual design, mechanical, electrical and sonic parameters, along with our dedicated manufacturing process, have all been optimized to provide a professional tool that exhibits quality, reliability and longevity.
The Synergy-Series amplifiers are 2 unit (3.5") high, 19" wide, rack mountable units.
Each channel of the amplifier comprises a balanced active input with a buffered attenuator driving a differential class A drive stage which in turn drives a fan-cooled, class AB, BJT output stage configuredas an emitter follower. The amplifier operates from a high current-capable linear power supply.
These amplifiers have been specifically designed to deliver their high power output with minimal distortion, and provide the critical degree of control required by your speakers, at high duty cycles for extended periods.
Austr alian Monitor
Figure 1 Amplifier Block Diagram
6 Controls & Connectors
2. Controls, Connectors & Indicators
MAX
LEVEL-D
MIN
D
STATUS
C
OVERLOAD
MAX
LEVEL-C
MIN
FAULT
POWER
THERMAL
SY 4200
MAX
LEVEL-B
MIN
B
STATUS
A
OVERLOAD
MAX
LEVEL-A
MIN
Australian Monitor
MAX
LEVEL-F
MIN
F
STATUS
E
OVERLOAD
MAX
LEVEL-E
MIN
MAX
LEVEL-D
MIN
D
STATUS
C
OVERLOAD
MAX
LEVEL-C
MIN
MAX
LEVEL-B
MIN
B
A
STATUS
OVERLOAD
MAX
LEVEL-A
MIN
POWER
FAULT
THERMAL
SY 6125
Figure 2 Front Panel Layout (left to right - SY4200, SY1200, SY6125)
Controls & Connectors 7
Front Panel
The Synergy Series differ only slightly across all models and all share the same features on their front panels.
Figure 1
amplifiers, SY4200, SY1200 & SY6125. The SY1200 looks the same as the SY400, SY800, SY1600, SY400V & SY800V. The functions of the controls and indicators are as follows:
1 Attenuator
2 Status Indicator
shows the panel layout of three Synergy
Level control for your amplifier is provided by a potentiometer on the front panel and indicates gain. There are 2 controls on all models except the SY4200 which has 4 controls and the SY6125 which has 6 controls. Each control is labelled for the channel which it controls.
This is a dual colour LED which displays the status of the output stage and displays three levels of operation.
These levels are: Below 1 watt (unlit) 1 watt and above ( ) 1dB below actual clipping ( )
The LED will turn green once the output voltage exceeds 2.828 volts (1 watt re 8 ohms or 2 watts re 4 ohms). For the SY400V & SY800V the output voltage is 10 volts & 7.070 volts (2 watts re 50ohm & 25ohm) respectively
The LED will change to red once the output exceeds the -1dB point before actual clipping of the amplifier’s output stage. The threshold of the ­1dB point is referred to the amplifier supply rails and alters with changes in the mains supply, changes in the load and duty cycle fluctuations.
The attack and decay time (ballistics), of the status circuit are those of a Peak Programme Metre (P.P.M.)
If using this indicator to line up sensitivities, apply a steady state tone (e.g. slate on a mixing console). The 1 watt level is the mid-point between the indicator illuminating and extinguishing green.
Synergy
green red
NOTE: The amplifier is not damaged by running into clipping, . To maximise the life of your speakers, try to keep clipping infrequent. Clipping on the SY400V & SY800V may cause speaker transformers to saturate causing the amplifier to shut down. For this reason the voltage limiters should always be engaged on the SY400V & SY800V (see Rear Panel-Limiter Switch on page 11).
but speakers may be
3 Overload Indicator
This LED will illuminate when an overload
amber
condition exists.
Overload conditions can occur under extreme operating conditions such as:
- complex or very low loads
- over driving the amplifier
- speaker transformer saturation
It should be noted that the minimum load for the amplifier is 4 ohms per channel (8 ohm bridged) except the SY400V which has a minimum load of 50 ohms per channel and the SY800V which has a minimum load of 25 ohms per channel. (The SY400V & SY800V cannot be bridged).
If an overload occurs, the amplifier will shut down and mute all outputs except the SY6125 & SY4200 which will only mute the channel with the overload. If the overload is only transitory, then the amplifier will resume normal operation after approximately 7 secs. If the fault is continuous, then the amplifier will remain muted.
4 Power Switch
Press the switch to for power ( )and for power ( ). At start-up (turn-on), the input to the amplifier is muted for approximately two seconds.
off 0
up on I down
5 Thermal Indicator
In the advent of a thermal overload, this LED will
red,
turn indicating that the internal operating temperature of one or both amplifier channels has exceeded a safe level of operation and the channels will be automatically muted. The fans will continue to run and once the effected channel/s have had a cool-down period, they will un-mute and return to normal operation.
Austr alian Monitor
8 Controls & Connectors
NOTE: You should always ensure that the fan grille is kept clean and free from the build up of dust andlint
of your amplifier and reduce the possibility of it prematurely going into thermal shutdown mode. See the section “Installation - Cooling “ on page 14 for recommended cooling procedures.
. This will ensure longer operation
6 On Indicator
This LED will illuminate and indicates that the amplifier is on and receiving mains power.
blue
7 Fault Indicator
This LED indicates a significant problem with
red
the amplifier and the amplifier should be returned to an authorised technician for servicing.