7. Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers,
stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the grounding-type plug.
A grounding type plug has two blades and a third grounding prong.
The wide blade or the third prong are provided for your safety. If the
provided plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly
at plugs, convenience receptacles, and the point where they exit from
the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Refer all servicing to qualified service personnel. Servicing is required
when the apparatus has been damaged in any way, such as power-supply
cord or plug is damaged, liquid has been spilled or objects have fallen into
the apparatus, the apparatus has been exposed to rain or moisture, does
not operate normally, or has been dropped.
13. This appliance shall not be exposed to dripping or splashing water and
that no object filled with liquid such as vases shall be placed on the
apparatus.
14. Connect the equipment to an appropriate wall outlet that is readily
accessible.
15. The mains plug is used as the disconnect device and shall remain
readily accessible. If the mains plug is not readily accessible due to
mounting in a 19” rack, then the mains plug for the entire rack must
be readily accessible.
16. WARNING: To reduce the risk of fire or electric shock, do not expose this
apparatus to rain or moisture.
17. An appliance with a protective earth terminal should be connected to a
mains outlet with a protective earth connection.
1. LISEZ ces instructions.
2. Tenez ces instructions.
3. Notez tous les avertissements.
4. Suivez toutes les avertissements.
5. N’utilisez pas ce produit près de l’eau (la piscine, la plage, le lac, etc.).
6. Nettoyez seulement avec une étoffe sèche.
7. Ne bloquez aucuns troux de ventilation. Installez en accord avec
les instructions du manufacturier.
8. N’installez près aucunes sources de chaleur comme radiateurs, registres
de chaleur, fours ou les autres équipements (y compris amplificateurs)
qui produisent la chaleur.
9. Ne pas tenter de modifier la prise de terre. Une fiche de base type a deux
a deux tranchants et une troisième pointe de base, le tranchant large ou la
troisième pointe est fourni pour votre sécurité. Si la fiche donnée ne
conforme pas votre prise de contact, consultez un électricien pour
remplacement de la prise de contact obsolète.
10. Protegez le cordon de secteur contre être marchée dessus ou pincez
en particulier aux fiches, aux douilles de convenance, et au point où ils
sortent de l’appareil.
11. Seulement utilisez attachements/accessoires spécifiés par le
manufacturier.
12. Référez au personnel qualifié de service pour toutes réparations. La
réparation est donnée quand le système a été endommagé à n’importe
façon, par exemple un fil ou une fiche endommagé(e) de la source
d’alimentation. Avoir été exposé à pluie ou humidité, n’opère pas
normalement, ou avoir été tombé.
13. L’appareil ne doit pas être exposé aux écoulements ou aux éclaboussures
et aucun objet ne contenant de liquide, tel qu’un vase, ne doit être placé
sur l’objet.
14. Branchez l’appareil à une source appropriée et faire que la prise à
débrancher soit facilement accessible.
15. La prise du secteur ne doit pas être obstruée ou doit être facilement
accessible pendant son utilisation. Pour être complètement déconnecté
de l’alimentation d’entrée, la prise doit être débranchée du secteur.
16. AVERTISSEMENT: Pour éviter le risque d’incendie ou de chocs électriques,
ne pas exposer cet appareil à la pluie ou à l’humidité.
17. Un appareil avec la borne de terre de protection doit être connecté au
secteur avec la connexiion de terre de protection.
PAGE 2
AMD SERIES INSTALLATION AND OPERATION MANUAL
INTRODUCTION AND CONTENTS
AMD SERIES
The AMD P series of power amplifiers from Australian Monitor
represent a quantum leap forward in connectivity, controllability &
flexibility in the constant voltage amplifier market. The AMD series
allows contractors to integrate the power amplifier to third party
control systems for remote control and status reporting. The AMD
series amplifiers also offer the flexibility of comprehensive on board
DSP processing and 24VDC back up power.
Australian Monitor AMD P series is the future of constant
voltage amplification.
INTRODUCTION 3
FRONT PANEL 4
REAR PANEL 5
INSTALLATION 6
SOFTWARE APPLICATION 7
THIRD PARTY CONTROL PROTOCOL 11
DIMENSIONS 18
SPECIFICATIONS 19
Revision 1.2 May 2012
WARNING!
TO PREVENT FIRE OR SHOCK HAZARD, DO NOT USE THE PLUG WITH
AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES
CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE.
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE
THIS APPLIANCE TO RAIN OR MOISTURE.
TO PREVENT ELECTRICAL SHOCK, MATCH WIDE BLADE PLUG TO WIDE SLOT, FULLY INSERT.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
The lightning flash with arrowhead symbol,
within an equilateral triangle, is intended
to alert the user to the presence of
uninsulated “dangerous voltage” within
the product’s enclosure that may be of
sufficient magnitude to constitute a risk
of electric shock to persons.
WARNING: TO REDUCE THE RISK
OF ELECTRIC SHOCK, DO NOT
REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
The exclamation point within an equilateral
triangle is intended to alert the user to
the presence of important operating and
maintenance (servicing) instructions in the
literature accompanying the appliance.
Rating plate and caution marking are marked on the back enclosure of the apparatus
AMD SERIES INSTALLATION AND OPERATION MANUAL
PAGE 3
FRONT PANEL
1
AMD4100P
SIGNALCLIP
FAULT
CHANNEL 1CHANNEL 2CHANNEL 3CHANNEL 4
234
1
Signal Indicator
The signal indicators (blue) illuminates when audio is present on the relevant
amplifier channel.
2
Fault Indicator
The fault indicators (red) illuminate when a fault is detected on the relevant
amplifier channel.
A fault may be detected due to short circuit conditions or internal failure.
SIGNALCLIP
FAULT
SIGNALCLIP
FAULT
SIGNALCLIP
FAULT
4 channel model shown here
CONTROL
3
Clip Indicator
The clip indicators (red) illuminate when an amplifier channel is approaching full
power or clipping.
If this occurs often, the input source or amplifier gain should be reduced
accordingly. Alternately the compressor block for the effected channel could be
set to avoid the clipping condition.
4
Control Indicator
The control indicator (blue) blinks whenever a third party control system
accesses the amplifier or adjusts an operating parameter.
The control indicator also blink briefly when the amplifier is in the low power
standby mode.
PAGE 4
AMD SERIES INSTALLATION AND OPERATION MANUAL
Made in The Philippines
POWER
+24VDC
0VDC
OUTPUT 4
OUTPUT 3
CLASS 2 WIRINGCLASS 2 WIRING
OUTPUT 2OUTPUT 1
INPUT 4
LEVEL 4 LEVEL 3
INPUT 3INPUT 2
REAR PANEL
4 channel model shown here
LEVEL 2 LEVEL 1
INPUT 1
ETHERNET
VCA 4
VCA 3
VCA 2
VCA 1
1
Mains Input
1
34526
Mains input is via a 3-pin IEC socket. A mains cable to suit your region is
provided with your Australian Monitor amplifier.
The amplifier may be isolated from the mains supply with the mains switch
provided. All models are internally fused.
The AMD2100P model operates from a wide range supply of 90 to 264VAC
while all remaining models are internally configured for either 115V or 230VAC
operation.
Please contact Australian Monitor should your amplifier need to be changed
from its shipped voltage configuration.
2
Battery Input
24 VDC input for emergency power systems.
3
Amplifier Outputs
Amplifier outputs are terminated on 5.08” pitch removable connectors.
Mating connectors are provided with your Australian Monitor amplifier.
Each amplifier channel output provides 4 Ohm (voice coil), 70V and 100V
(constant voltage) outputs.
For each amplifier channel, only one output type should be used. You may use
a different output type for each channel ie. 4 Ohms on Channel 1, 100V on
Channel 2.
5
Ethernet Port
The Ethernet port provides PC connectivity for use with the supplied software
application and also remote control and status monitoring for use with third
party control systems.
A pair of LED indicators provide link activity and link speed status feedback.
Modules for both Crestron and AMX control systems are available from the
Australian Monitor web site.
For users of other control systems, please refer to the Third Party Control
Protocol section later in this document for a detailed description of the protocol.
6
Logic Controls
VCA: Remote VCA level controls per channel. An Australian Monitor RC1
remote panel or any 500 kohm potentiometer may be connected between
the GND pin and a VCA pin.
GRN: Low Power Standby Mode. The amplifier will enter low power standby
mode when the GRN pin is connected to the GND pin.
RS232: Serial port for third party control.
Modules for both Crestron and AMX control systems are available from
the Australian Monitor web site.
Refer to the Third Party Control Protocol section later in this document
for detailed description of the protocol.
4
Amplifier Inputs
Balanced line level XLR inputs. The pin configurations are as per the diagram
to the right.
Input level controls are provided for each input channel.
AMD SERIES INSTALLATION AND OPERATION MANUAL
Ethernet
LINK/ACTIVITY
ON: Link Activity
FLASH: Activity
SPEED
OFF: 10Mbps
ON: 100Mbps
Female XLR
PIN 2
HOT
(+)
PIN 3
COLD
(–)
PIN 1
GND
PAGE 5
INSTALLATION
Unpacking
Every Australian Monitor product is tested and inspected before leaving our factory
and should arrive in perfect condition.
When opening the carton check for any noticeable damage to your Australian
Monitor product. Please notify your Australian Monitor reseller immediately should
any damage be discovered.
Should you ever need to re-ship the amplifier, always use the original packaging
carton and materials.
Mounting
The AMD Series power amplifiers are one rack unit high (1RU) and will fit a standard
EIA 19” rack. A rack rear support bracket is supplied and must be must be installed
when rack mounting the amplifier. The rear support bracket should be installed to
the rack (rear rails) prior to mounting the amplifier. Failure to mount or support the
amplifier correctly may lead to chassis damage which is not covered by warranty.
Typically amplifiers may be stacked directly on top of each other with no need for
spacing between units, unless installed in high ambient temperature environments
were a single rack unit space between amplifiers will assist cooling further.
Cooling
The AMD series power amplifiers utilise fan forced air cooling, with air flowing from
right to left (viewed from the front).
Ensure adequate ventilation and/or heat extraction is provided when rack mounting
the amplifier. Installations with multiple AMD P series amplifiers or other heat
generating equipment with in the same rack will benefit from full rack cooling, using
conventional ducted cool-air fed through the rack base.
For smaller installations or were rack cooling is not possible, ensure the rack
provides free air flow above and below the rack. Also avoid the use of rear doors on
the equipment rack.
Please consider the thermal dissipation figures provided later in this manual when
installing your AMD series amplifier.
Grounding
In the interests of safety, ensure the amplifier is connected to a suitable grounded
mains outlet and NEVER disconnect the earth pin on the AC power cord.
PAGE 6
AMD SERIES INSTALLATION AND OPERATION MANUAL