IMPORTANT SAFETY INFORMATION
PRÉCAUTIONS DURANT UTILISATION
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers,
stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug.
A polarized plug has two blades with one wider than the other.
A grounding type plug has two blades and a third grounding prong.
The wide blade or the third prong are provided for your safety. If the
provided plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly
at plugs, convenience receptacles, and the point where they exit from
the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table
specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the cart/
apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when
unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required
when the apparatus has been damaged in any way, such as power-supply
cord or plug is damaged, liquid has been spilled or objects have fallen into
the apparatus, the apparatus has been exposed to rain or moisture, does
not operate normally, or has been dropped.
15. This appliance shall not be exposed to dripping or splashing water and
that no object filled with liquid such as vases shall be placed on the
apparatus.
16. Plug this apparatus to the proper wall outlet and make the plug to be
disconnected readily operable.
17. Mains plug is used as disconnected device and it should remain readily
operable during intended use. In order to disconnect the apparatus from
the mains completely, the mains plug should be disconnected from the
mains socket outlet completely.
18. WARNING: To reduce the risk of fire or electric shock, do not expose this
apparatus to rain or moisture.
19. An appliance with a protective earth terminal should be connected to a
mains outlet with a protective earth connection.
20. AMC+30 - Risk of hazardous energy. Class 2 wiring should be used.
21. AMC+60, AMC+120, AMC+250 - Risk of hazardous voltage. Class 3
wiring should be used.
22. The apparatus should be disconnected from the mains completely before
speaker wiring. The speaker output should be proper protected from
direct contact and pay attention to speaker connections, terminals and
speaker wiring during normal operation.
To indicate hazards arising from dangerous voltages.
1. LISEZ ces instructions.
2. Tenez ces instructions.
3. Notez tous les avertissements.
4. Suivez toutes les avertissements.
5. N’utilisez pas ce produit près de l’eau (la piscine, la plage, le lac, etc.).
6. Nettoyez seulement avec une étoffe sèche.
7. Ne bloquez aucuns troux de ventilation. Installez en accord avec
les instructions du manufacturier.
8. N’installez près aucunes sources de chaleur comme radiateurs, registres
de chaleur, fours ou les autres équipements (y compris amplificateurs)
qui produisent la chaleur.
9. Ne défaites pas le but de sécurité de la fiche polarisée ou base-type.
Une fiche polarisée a deux tranchants avec un plus large que l’autre.
Une fiche de base type a deux a deux tranchants et une troisième
pointe de base, le tranchant large ou la troisième pointe est fourni
pour votre sécurité. Si la fiche donnée ne conforme pas votre prise
de contact, consultez un électricien pour remplacement de la prise
de contact obsolète.
10. Protegez le cordon de secteur contre être marchée dessus ou pincez
en particulier aux fiches, aux douilles de convenance, et au point où ils
sortent de l’appareil.
11. Seulement utilisez attachements/accessoires spécifiés par le
manufacturier.
12. Utilisez seulement avec un chariot, un stand, un trépied,
un support ou une table indiquée par le manufacturier, ou
vendue avec l’appareil. Quand un chariot est utilisé, faites
attention en déplaçant la combinaison d’appareil/chariot
pour éviter de se déséquilibrer.
13. Arrachez la fiche du dispositif durant éclair et orage ou
quand pas utilisé pour longues périodes de temps.
14. Référez au personnel qualifié de service pour toutes réparations. La
réparation est donnée quand le système a été endommagé à n’importe
façon, par exemple un fil ou une fiche endommagé(e) de la source
d’alimentation. Avoir été exposé à pluie ou humidité, n’opère pas
normalement, ou avoir été tombé.
15. L’appareil ne doit pas être exposé aux écoulements ou aux éclaboussures
et aucun objet ne contenant de liquide, tel qu’un vase, ne doit être placé
sur l’objet.
16. Branchez l’appareil à une source appropriée et faire que la prise à
débrancher soit facilement accessible.
17. La prise du secteur ne doit pas être obstruée ou doit être facilement
accessible pendant son utilisation. Pour être complètement déconnecté
de l’alimentation d’entrée, la prise doit être débranchée du secteur.
18. AVERTISSEMENT: Pour éviter le risque d’incendie ou de chocs électriques,
ne pas exposer cet appareil à la pluie ou à l’humidité.
19. Un appareil avec la borne de terre de protection doit être connecté au
secteur avec la connexiion de terre de protection.
20. AMC+30 - Danger d’électrocution. Afin d’assurer un bon fonctionnement
utiliser un câble de catégorie 2.
21. AMC+60, AMC+120, AMC+250 - Danger de voltage. Afin d’assurer un
bon fonctionnement utiliser un câble de catégorie 3.
22. Assurez-vous que l’appareil est hors tension avant de connecter les hauts
parleurs. Verifiez que la sortie des enceintes soit protégées contre un
contact physique. Respecter les polarités des terminaux ainsi que le
câblage des enceintes pendant le fonctionnement afin d’assurer une
utilisation sécurisee.
Pour indiquer les risques résultant de tensions dangereuses.
INTRODUCTION AND CONTENTS
AMC+ SERIES
The Australian Monitor AMC+ series of amplifiers takes the heritage
and reliability of our famous AMIS series amplifiers and integrates
these features into low cost amplifiers for applications where
reliability is everything, but the more elaborate features of our AMIS
series are not required.
Available in 30, 60, 120 and 250 watt versions, the AMC+ series
are 2 RU mixer amplifiers, featuring 70/100 volt line and 4 ohm
outputs, and 4 universal
mic/line inputs.
Master volume and overall treble and bass controls are provided,
along with Vox triggered muting (defeatable), giving channel 1
priority over inputs 2, 3 and 4. There is also the facility to add a tone
generator card.
The Australian Monitor AMC+ series gives the contractor a low cost
alternative in applications that are price sensitive, but still require a
high quality of sound reproduction and reliability.
INTRODUCTION 3
FRONT PANEL 4
REAR PANEL 5
INSTALLATION 6
TROUBLESHOOTING 8
BLOCK DIAGRAM 9
FUNCTIONAL NOTES & INTERNAL ADJUSTMENTS 10
DIMENSIONS 11
SPECIFICATIONS 12
NOTES 14
Revision 1.9 September 2011
WARNING!
TO PREVENT FIRE OR SHOCK HAZARD, DO NOT USE THE PLUG WITH
AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES
CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE.
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE
THIS APPLIANCE TO RAIN OR MOISTURE.
TO PREVENT ELECTRICAL SHOCK, MATCH WIDE BLADE PLUG TO WIDE SLOT & FULLY INSERT.
CAUTION
THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED SERVICE PERSONNEL ONLY.
TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER THAN THAT
CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
The lightning flash with arrowhead symbol,
within an equilateral triangle, is intended
to alert the user to the presence of
uninsulated “dangerous voltage” within
the product’s enclosure that may be of
sufficient magnitude to constitute a risk
of electric shock to persons.
WARNING: TO REDUCE THE RISK
OF ELECTRIC SHOCK, DO NOT
REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
The exclamation point within an equilateral
triangle is intended to alert the user to
the presence of important operating and
maintenance (servicing) instructions in the
literature accompanying the appliance.
Rating plate and caution marking are marked on the back enclosure of the apparatus
PAGE 3AMC+ SERIES INSTALLATION AND OPERATION MANUAL
FRONT PANEL
1
CH 1–4
These control the levels for each channel input.
2
Bass
There is 12dB of cut and boost at 100Hz.
5 62 3 41
3
Treble
There is 9dB of cut and boost at 10kHz.
4
Master
This controls the overall mixed output level.
5
On
This LED indicates the unit is powered “on”.
6
Power
This switch switches power on or off the mains. The up position is on.
NOTE:
For the model AMC+30
Risk of hazardous energy. Class 2 wiring should be used. The apparatus
should be disconnected from the mains completely before speaker
wiring. The speaker output should be proper protected from direct
contact and pay attention to speaker connections, terminals and
speaker wiring during normal operation.
PAGE 4 AMC+ SERIES INSTALLATION AND OPERATION MANUAL
For the model AMC+60, AMC+120, AMC+250
Risk of hazardous voltage. Class 3 wiring should be used. The
apparatus should be disconnected from the mains completely before
speaker wiring. The speaker output should be proper protected from
direct contact and pay attention to speaker connections, terminals and
speaker wiring during normal operation.
AMC+ 120
115 V. FUSE T4AH 250V
230 V. FUSE T2AH 250V
DIRECT OUT
OHM
4
C
Audio Amplifier
Model: AMC+120
Rated Value:
115V~60Hz 460W
230V~ 50Hz 460W
Manufacture Date:
Made In China
CLASS 2 WIRING
LINE
70
C
This terminal is hazardous live and that external wiring connected
to these terminals requires installation by an instructed person.
TONE MODULE
100
COM 1 2 3 4
CONFORMS TO
ANSI/UL SYD.60065
CERTIFIED TO
CAN/CSA STD.C22.2
No.60065
REAR PANEL
6
5
1
CH 1–4
Each channel input section has two inputs: XLR input – This
is a balanced microphone input. It has an input sensitivity of
1mV. RCA input – This is an unbalanced line level input.
It has an input sensitivity of 150mV. The two RCA sockets
are summed to mono internally.
2
REC Output
The REC output is on unbalanced RCA connectors. The output
level is 150mV into 10kohm at rated output. The output is
dual mono.
The REC output is not affected by the MASTER volume control
or the BASS and TREBLE controls.
The REC output does not receive the tone signal if the
optional tone generator module is installed.
3
Line Output
The LINE output is on a balanced XLR connector. The output
level is 0.775V into 1k at rated output.
Note: When wiring the LINE output as unbalanced, Pin2
should be wired as hot and Pin1 should be wired as ground/
shield. Do not wire Pin3.
8
1234 7
Minimum Impedance AMC+30 AMC+60 AMC+120 AMC+250
Distributed Line Output
70V 166ohm 83ohm 41ohm 20ohm
100V 333ohm 166ohm 83ohm 40ohm
Low Impedance Output
4ohm 4ohm 4ohm 4ohm
Note: Only connect one output – either Distributed Line or Low Impedance per channel.
Do not connect LowZ and 70/100V at the same time.
The output strip comes fitted with a touch-proof cover held in place by two M3 machine screws
with flat and spring washers.
6
IEC Mains Input Socket
This is a standard IEC 3 pin socket. It accepts a standard IEC mains cable, provided. The fuse
draw at 5 contains the mains fuse and a spare. The mains fuse is a time lag (slow blow)
HRC 20mm x 5mm ceramic type fuse.
The ratings are: AMC+30 AMC+60 AMC+120 AMC+250
230V operation 0.5A 1.6A 2A 4A
4
Direct Out
Speaker connections are provided on screw terminals. 4 ohm
low impedance, 70V and 100V line outputs are provided.
5
Mains Voltage Selector
The operating voltage of the amplifier is user selectable
between for 115V or 230V operation via a slide switch
located above the AC mains inlet. This switch should be set to
match the AC voltage of your country.
Failure to set the Mains Voltage Selector correctly prior
to use will result in catastrophic failure.
115V operation 1A 3.15A 4A 8A
Always replace the fuse with one of the same value and type.
Always disconnect power to the amplifier before replacing fuses.
7
(Optional) Tone Module
These terminals are for use with an optional tone module (not supplied). Use Australian Monitor
ATC5488 module.
8
Phantom Power
12V phantom power is available for condenser or electret microphones on the XLR input when
this switch is pushed in.
PAGE 5AMC+ SERIES INSTALLATION AND OPERATION MANUAL