AusClimate D-025, D-085, D-060, D-105, D-155 Operation Manual

...
Page 1
Please read this manual carefully before using your dehumidifier. If you have any question about using your dehumidifier please contact your distributor.
Page 2
1
2
4
9
12
15
16
18
19
20
21
22
INSTALLATION
CONTENTS
DISTRIBUTOR DETAILS -------------------------------------
TECHNICAL PARAMETERS ------------------------------------- 19
Page 3
There are 6 models of dehumidifier. All the dehumidifiers in this
manual are designed to adjust the indoor dehumidification from
10%RH to 90%RH indoor. They are designed to optimize indoor
air humidity within the ambient temperature range from 20to
35. Generally, it would be comfortable when humidity is in the
range of 40%-60%RH.
Page 4
No connection within the length of the
power cord or extension of power cord.
Multifunctional socket is prohibited.
Remove dirt from the power terminal
or power plug
Do not scratch bend or twist the power
cord
Do not put heavy objects on the power cord, do not heat it, and do not bend or twist it. The cord may become damaged and it may cause a fire or electric shock.
Consult your distributor for
installlation.
If the unit continues to be operated in an abnormal condition, it may cause a fire, hazard, etc. In this case, consult your distributor.
If this is done incorrectly, it may cause a fire, electric shock, water leakage or other hazard.
Consult your distirbutor.
Never pu t an yt hi ng on top of the unit.
Do not connect a grounding wire to a gas pipe, water pipe, lightning rod or ground wire of a telephone. If a grounding is incorrect, it may cause an electric shock.
If dirt adheres to the terminal, or fixed wire is incomplete, it may cause a fire or electric shock.
When an abnormality(smell of burning, etc)occurs, stop the unit and disconnect the power or turn off the breaker.
Do not insert your finger or stick, etc. into the air inlet/air outlet.
Page 5
If pulled the core wire of the power cord may become disconnected and may cause a fire.
It may cause a fire or damage the cabinet.
When the unit is to be cleaned, switch off and disconnect the power or turn off the circuit breaker.
When the unit is not going to be used for a long time, disconnect the power or turn off the circuit breaker.
there
are flammable gases
This may cause fire hazard.
It may cause an injury or damage to unit
It may cause an injury, etc. by falling
down
Consult your distributor.
Since the fan rotates at high speed during operation, it may cause an injury.
Page 6
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play
with the appliance.
If the power supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
For units with fixed wiring with permanent connection to the
supply mains, a means for disconnection must be incorporated in accordance with the wiring rules.
4
Page 7
244
266
Power cord
5
Page 8
336
308
905
Power cord
6
Page 9
Power cord
7
Page 10
8
Anchor bolts, 6 units per dehumidifier , used for wall mounted installation.
Dehumidifier fixing bolts, 4
units per dehumidifier, used
for wall mounted installation.
Floor mounted stands, 4
units per dehumidifier, used
for floor mounted installation.
Universal wheels, 4 units
per dehumidifier, used
for mobile installation.
Water drain hose, 1 unit
per dehumidifier.
Wall mounted bracket, 2 units per dehumidifier.
Page 11
CN5
ON
COM
N1 N2 N3
ON
COM
LP
HP
PROIN
Transformer
CN4
Power supply
~230V/50Hz
Low-pressure protect
High-pressure protect
Main controller PCB
RLY2
RLY1
To display PCB
Dehumidifying
sensor
ON
COM
TRAN/IN
AC-N
ON
COM
LP
HP
CN6 DISPLAY
Transformer
Power supply
~230V/50Hz
Low-pressure protect
High-pressure protect
Main controller PCB
RLY2
RLY1
To display PCB
CN7
Dehumidifying
sensor
TRAN/OUT
Ambient temperature
sensor
Tube temperature
sensor
Ambient temperature
sensor
Tube temperature
sensor
PIPE
ROOM
CN8
CN9
CN2
FAN
MOTOR
COMP
C
R
S
CN1
LOW
MIDHI
N
D-025
9
Page 12
10
D-042,D-060
CN5
ON
COM
N1 N2 N3
ON
COM
LP
HP
PROIN
Transformer
CN4
Power supply
~230V/50Hz
Low-pressure protect
High-pressure protect
Main controller PCB
RLY2
RLY1
To display PCB
Dehumidifying
sensor
ON
COM
TRAN/IN
AC-N
ON
COM
LP
HP
CN6 DISPLAY
Transformer
Power supply
~230V/50Hz
Low-pressure protect
High-pressure protect
Main controller PCB
RLY2
RLY1
To display PCB
CN7
Dehumidifying
sensor
TRAN/OUT
Ambient temperature
sensor
Tube temperature
sensor
Ambient temperature
sensor
Tube temperature
sensor
PIPE
ROOM
CN8
CN9
CN2
FAN
MOTOR
COMP
C
R
S
CN1
LOW
MIDHI
N
Page 13
SINGLE PHASE(1PH/50Hz
D-085
11
ON
N1 N2 N3
LP
HP
PROIN
Transformer
CN4
Power supply
~230V/50Hz
Low-pressure protect
High-pressure protect
Main controller PCB
RLY2
RLY1
To display PCB
Dehumidifying
sensor
COM
TRAN/IN
AC-N
LP
HP
CN6 DISPLAY
Transformer
Power supply
~230V/50Hz
Low-pressure protect
High-pressure protect
Main controller PCB
RLY2
RLY1
To display PCB
CN7
Dehumidifying
sensor
TRAN/OUT
Ambient temperature
sensor
Tube temperature
sensor
Ambient temperature
sensor
Tube temperature
sensor
PIPE
ROOM
CN8
CN9
CN2
FAN
MOTOR
COM
ON
CN1
S C
R
COMP
Y/Gn
Wh
Bk
Re
Relay
LOW
MIDHI
N
CN5
Page 14
12
plete as stated on the packing list. If severe
grill or
IF DEHUMIDIFIER HAS BEEN PL ACED ON IT’S
SIDE IN TRANSIT THEN DEHUMIDIFIER MUST
BE LEFT IN AN UPRIGHT POSITION FOR A
MINIMUM PERIOD OF 24 HRS PRIO R TO
OPERATION.
(Failing the above may cause damage to the
dehumidifier and void your warranty).
Requires free space to provide air flow to a
1.How to install the dehumidifier wheels
Step 1. Place dehumidifier on chocks or
plinth as per diagram.
Step 2. Secure supplied wheels to
dehumidifier base.
Step 3. Place dehumidifier on level surface.
Step 4. Adjust wheel height to ensure
dehumidifier is level.
Step 5. Install drain hose to drainage point.
Hose must be lower than the
dehumidifier outlet to drain water
away. Ensure hose has no kinks.
Step 6. Turn on dehumidifier to check for
vibrations. If vibrating re-adjust levels.
Step 7. Installation is complete and
dehumidifier is ready for use.
Page 15
13
2.How to install the dehumidifier on the ground using stands
Step 1. Place dehumidifier on chocks or plinth as per diagram.
Step 2. Secure supplied stands/feet to dehumidifier base.
Step 3. Place dehumidifier on level surface.
Step 4. Adjust stand height to ensure dehumidifier is level.
Step 5. Install drain hose to drainage point. Hose must be lower than the
dehumidifier outlet to drain water away. Ensure hose has no kinks.
Step 6.Turn on dehumidifier to check for vibrations. If vibrating re-adjust
levels.
Step 7.Installation is complete and dehumidifier is ready for use.
Page 16
14
3.How to install the dehumidifier on the wall.
Step 1. Select dehumidifier position on concrete or brick wall allowing sufficent
space between the top of the dehumidifier and ceiling for air flow.
Step 2. Mark bracket anchor bolt holes on the wall ensuring the space between the
two brackets match with the dehumidifier base bolt holes as per diagram.
Check for level.
Step 3. Drill 10mm holes, min 65mm deep and insert supplied anchor bolt with
hammer.
Step 4. Secure brackets to wall. Check they are level and aligned with dehumidifier
base bolt holes.
Step 5. Position dehumidifier on brackets and secure with supplied bolts.
Step 6. Install drain hose to drainage point. Hose must be lower than the
dehumidifier outlet to drain water away. Ensure hose has no kinks.
Step 7. Turn on dehumidifier to check for vibrations. If vibrating re-adjust levels.
Step 8. Installation is complete and dehumidifier is ready for use.
Page 17
15
3.
b
The button or button is used to set desired air humidity. Each time these buttons are pressed, the desired air humidity will change by 1%. The adjustable range is 10% RH to 90% RH.
4. button to turn the electric heater on and off.
Electric heater button
Page 18
16
IF THE DEHUMIDIFIER STOPS WORKING, ONE OF THE EIGHT ERRORS WILL BE DISPALYED.
distributor.
distributor.
distributor.
.
distributor.
The ambient temperature is over or under the working temperature. If the ambient temperature is over 42℃ or below 7℃, it will display E3. Please contact your distributor.
E3:
Page 19
17
and
distributor.
distributor.
distributor.
It displays E5 when it is first time the unit is connected to the power supply and indicates the phase error. Please contact you distributor.
.
Page 20
18
Turn off the circuit breaker, then disconnect the power cord.
circuit breake r
Page 21
Model D-025 D-042 D-060 D-085 D-105 D-105 D-155
Gas R407c/R410a R407c/R410a
R407c/R410a R407c/R410a R407c/R410a
R407c/R410a R407c/R410a
Capacity (L/hr) 2.5 4.2 6 8.5 10.5 10.5 15.5
Heating Capacity (w) 1600 2200 3000 4500 5500 5500 7200
Power Consumption (w) 915 1250 1670 2185 2670 2670 3345
Air Flow Rate (m3/hr) 450 500 750 900 1250 1250 1550
Power Supply 230V/1ph/50Hz 380V/3Ph/50Hz
Current (A) 4.3 6.0 7.8 10.2 18 13 15.5
Noise (dB(A))
46 48
52
56 60
60 62
Drain Pipe(mm) 16 16 16 16 16 16 16
Dimension(mm) 890 x 266x 750 890 x 266x 750 1120x336x905 1120x336x905 1360 x 385 x 900 1360 x 385 x 900 1360 x 385 x 900
Weight(kg)
48 52 82 86 120 120 128
19
1.Customer should contact your specific service department or distributor for qualified installation and repair;
2.If any flexible cable is damaged,contact the specific service department or distributor to replace it with correct cable;
3.The mechanical and electrial diagrams or units are attached on the electric component.
Page 22
20
Crank Heater
3.
Most dehumidifiers will generate instantaneous large electric current at the start, which might bring the damage to the power supply system. The dehumidifier with soft-start function can decrease the instantaneous electric current by 30-50% and supply the maximum protection to the power supply system.
Most dehumidifiers usually start with difficultly when the ambient temperature is too low. The lubricant of the compressor can’t work smoothly due to the low temperature. The dehumidifier equipped with the crank heater can remove this potential risk. This useful design will effectively extend the dehumidifier life span.
Page 23
21
ATTACHMENT
Page 24
22
Proudly distributed by Ausclimate Pty Ltd
For all enquiries and contact details please visit our website:
Loading...