Aurora of America 330 User Manual

ATTENTION: SAFETY WARNINGS:
Read and understand all warnings before installation or servicing pump.
OPERATIONAL LIMITS: Maximum Operating Pressure: 175 psi at Temperatures
to 150
O
F (65.5°C)
Maximum Operating Temperature: 200°F (93°C)
ELECTRICAL SAFETY:
HIGH TEMPERATURE SAFETY:
HIGH PRESSURE SAFETY:
SERVICE
Your Aurora pump requires no maintenance other than periodic inspection, and occasional cleaning and lubrication of bearings. The intent of inspection is to prevent breakdown, thus obtaining optimum service life. The liquid end of the pump is lubricated by the fluid being pumped and therefore does not require periodic lubrication. The motor, however may require lubrication, in which case, the motor manufacturer’s recommendation should be followed.
REPAIRS
Before starting any work, insure the electrial power is locked out, the system pressure has been lowered to 0 psi and temperature of the unit is at a safe level.
Warning: Electrical Shock Hazard
All electrical connections are to be made by a qualified electrician in accordance with all codes and ordinances. Failure to follow these instructions could result in serious personal injury, death or property damage.
Warning: Electrical Overload Hazard
Insure all motors have properly sized overload protection. Failure to follow these instructions could result in serious personal injury, death or property damage.
Warning: Sudden Start-Up Hazard
Disconnect and lockout power source before servicing. Failure to follow these instructions could result in serious personal injury, death or property damage.
Warning: Hot Surface Hazard
If pumping hot water, insure guards or proper insulation is installed to protect against skin contact to hot piping or pump components. Failure to follow these instructions could result in serious personal injury, death or property damage.
Warning: Spraying Water Hazard
When servicing pump replace all gaskets and seals. Do not re-use old gaskets or seals. Failure to follow these instructions could result in serious personal injury, death or property damage.
Warning: High Pressure Hazard
The pump is rated at a maximum of 175 psi at 150°F. Do not exceed this pressure. Install properly sized pressure relief valves in system. Failure to follow these instructions could result in serious personal injury, death or property damage.
Warning: Expansion Hazard
Water expands when heated. Install properly sized thermal expansion tanks and relief valves. Failure to follow these instructions could result in serious personal injury, death or property damage.
Warning: Sudden Start-Up Hazard
Disconnect and lockout power source before servicing. Failure to follow these instructions could result in serious personal injury, death or property damage.
Warning: Spraying Water Hazard
When servicing pump replace all gaskets and seals. Do not re-use old gaskets or seals. Failure to follow these instructions could result in serious personal injury, death or property damage.
INSTRUCTION AND REPAIR MANUAL
MODEL 330
6
SECTION 6 ITEM 330 DATED FEBRUARY 2001
MODEL 330
2
Inspect removed parts at disassembly to determine if they can be reused. Cracked castings should never be reused. Scored or worn pump shafts should be replaced. Gaskets should be replaced at reassembly simply as a matter of economy. They are much less expensive to replace routinely than to replace individually as the need arises. While motors and motor controls are often returned to the manufacturer for repairs it is usually more practical and economical to repair the pump at the job site or the pump repair shop.
Cleaning of most parts can be accomplished with the use of clean rags.
DISASSEMBL
Y OF THE PUMP. READ AND UNDERSTAND ALL SAFETY WARNINGS AT THE BEGINNING OF THE MANUAL BEFORE BEGINNING INSTALLATION OR ANY REPAIR WORK. Disassemble only what is needed to make repairs or accomplish inspection.
PROCEDURE FOR REMOVING AND INSTALLING PUMP MOTOR.
DO NOT OPERATE THIS UNIT DRY
TO REMOVE MOTOR
1. Support motor on both sides. Remove four hex head cap screws (24) that hold motor to volute (9).
2. Carefully and slowly pull motor (25) until seal flange (19) and impeller (17) are completely out of the volute (9). Avoid resting entire unit on seal flange or impeller.
3. Remove Allen head lock screw (15) and washer (16) from center of impeller (17). Pull impeller from shaft. Do no lose square key (23).
4. Remove seal spring member (18) from shaft. Avoid cutting rubber parts or scratching carbon face.
5. Remove two hex head cap screws (21) from seal flange (19). Hold seal flange so that it doesn’t drop on motor shaft while removing screws. Remove seal flange.
6. Remove ceramic seal face member (18) from center of seal flange (19) and o-ring (20) from groove. Check for nicks and cuts. Replace as necessary.
7. Finally, remove water slinger (22) if replacing with new one or servicing motor.
TO INSTALL MOTOR
1. Slip water slinger (22) on motor shaft past shoulder.
2. Press ceramic seal face member (18) into center cavity of seal flange (19) with the smooth ceramic facing out. Clean and grease o-ring (20) and place in seal flange groove.
NOTE: MAKE SURE THAT CERAMIC FACE IS FREE FROM OIL OR GREASE.
3. Install seal flange on motor register and secure in place with two cap screws (21).
4. Press seal spring member (18) on motor shaft with carbon face towards ceramic seal member. Avoid cutting rubber parts on shaft.
5. Line up keyways and push impeller (17) on motor shaft up to shoulder. Insert square key (23) in place.
6. Secure impeller with washer (16), impeller gasket (16.5) and Allen head lock screw (15).
7. Position and carefully install assembled motor unit to the volute (9) and secure motor using cap screws (24).
MOTOR MUST BE WIRED AS INDICATED ON MOTOR JUNCTION BOX COVER AND NAME PLATE.
Remove motor shaft and cap. Momentarily, start and stop motor-while impeller is still turning, check end shaft rotation. Rotation must be in the direction indicated by the arrow on the outside of the volute (9). Fill strainer pot with water, install baseket, and secure cover. Pump is ready for operation. Press in motor shaft end cap.
ST
ARTING PUMP AFTER REASSEMBLY. Do not start pump until all air and vapor has been bled and there is liquid in the pump to provide the necessary lubrication. It is possible that the mechanical seal may drip during first few minutes of operation.
Warning: Use of Solvents
We do not recommend the use of solvents or petroleum cleaners for cleaning the parts because of the fire danger. Failure to follow these instructions could result in serious personal injury, death or property damage.
CAUTION
CAUTION
CAUTION
A LIST OF PARTS
MODEL 330 Gold Vane Pump
(See Figure 1)
Figure 1. Pump Exploded View
3. Hand Nut
4. Cover
5. O-ring
6. Pipe Plug
7. Strainer Pot
8. Basket
9. Volute
11. Gasket
12. Screw
13. Foot
14. Screw
15. Lock Screw
16. Impeller Washer
16.5 Impeller Gasket
17. Impeller
18. Mechanical Seal
19. Flange
20. O-ring
21. Capscrew
22. Water Slinger
23. Impeller Key
24. Capscrew
25. Motor
MODEL 330
3
PF-1
3
4
15
5
6
6
9
7
12
14
13
8
16
17
19
20
21
22
24
23
25
18
11
16.5